The Broadband Auto Frequency Channel Selection of the Digital TV Tuner using Frequency Mapping Function (주파수 매핑 함수를 이용한 광대역 주파수 자동 채널 선택용 디지털 TV 튜너)

  • 정영준;김재영;최재익;박재홍
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4B
    • /
    • pp.613-623
    • /
    • 2000
  • Digital TV tuner for 8-VSB modulation was developed with satisfying the requirements of ATSC. The double frequency conversion and the active tracking filter in the front-end were used to reduce interference of the adjacent channels and multi-channels, which suppress If beat and image band. However, it was impossible to get frequency mapping between tracking filter and first VCO(Voltage Controlled Oscillator) in the double conversion digital TV tuner differing from conventional NTSC tuner. This paper, therefore, suggests the available structure and a new method for automatic frequency selection by obtaining the mapping of frequency characteristic over tracking voltage and the combined hardware which compose of Micro-controller, EEPROM, D/A(Digital-to-Analog Converter), OP amp and switch driver to solve above problems.

  • PDF

Feasibility of On-chip Detection of Endotoxin by LAL Test

  • Lee, Eun-Kyu;Suh, Chang-Woo;Hwang, Sang-Youn;Park, Hyo-Jin;Seong, Gi-Hoon;Ahn, Yoo-Min;Kim, Yang-Sun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.132-136
    • /
    • 2004
  • The LAL (Limulus amebocyte lysate) test for the detection and quantification of endotoxin is based on the gelation reaction between endotoxin and LAL from a blood extract of Limulus polyphemus. The test is labor intensive, requiring dedicated personnel, a relatively long reaction time (approximately 1 h), relatively large volumes of samples and reagents and the detection of the end-point is rather subjective. To solve these problems, a miniaturized LOC (lab-on-a-chip) prototype, 62mm (L) ${\times}$ 18 mm (W), was fabricated using PDMS (polydimethylsiloxane) bonded to glass. Using this prototype, in which 2mm (W) ${\times}$ 44.3mm (L) ${\times}$ 100 $\mu\textrm{m}$ (D) microfluidic channel was constructed, turbidometric and chromogenic assay detection methods were compared, and the chromogenic method was found the most suitable for a small volume assay. In this assay, the kinetic-point method was more accurate than the end-point method. The PDMS chip thickness was found to be minimized to around 2 mm to allow sufficient light transmittance, which necessitated the use of a glass slide bonding for chip rigidity. Due to this miniaturization, the test time was reduced from 1 h to less than 10 min, and the sample volume could be reduced from 100 to ca. 4.4 ${\mu}$L. In summation, this study suggested that the LOC using the LAL test principle could be an alternative as a semi-automated and reliable method for the detection of endotoxin.

Fabrication of Flexible Surface-enhanced Raman-Active Nanostructured Substrates Using Soft-Lithography

  • Park, Ji-Yun;Jang, Seok-Jin;Yeo, Jong-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.411-411
    • /
    • 2012
  • Over the recent years, surface enhanced Raman spectroscopy (SERS) has dramatically grown as a label-free detecting technique with the high level of selectivity and sensitivity. Conventional SERS-active nanostructured layers have been deposited or patterned on rigid substrates such as silicon wafers and glass slides. Such devices fabricated on a flexible platform may offer additional functionalities and potential applications. For example, flexible SERS-active substrates can be integrated into microfluidic diagnostic devices with round-shaped micro-channel, which has large surface area compared to the area of flat SERS-active substrates so that we may anticipate high sensitivity in a conformable device form. We demonstrate fabrication of flexible SERS-active nanostructured substrates based on soft-lithography for simple, low-cost processing. The SERS-active nanostructured substrates are fabricated using conventional Si fabrication process and inkjet printing methods. A Si mold is patterned by photolithography with an average height of 700 nm and an average pitch of 200 nm. Polydimethylsiloxane (PDMS), a mixture of Sylgard 184 elastomer and curing agnet (wt/wt = 10:1), is poured onto the mold that is coated with trichlorosilane for separating the PDMS easily from the mold. Then, the nano-pattern is transferred to the thin PDMS substrates. The soft lithographic methods enable the SERS-active nanostructured substrates to be repeatedly replicated. Silver layer is physically deposited on the PDMS. Then, gold nanoparticle (AuNP) inks are applied on the nanostructured PDMS using inkjet printer (Dimatix DMP 2831) to deposit AuNPs on the substrates. The characteristics of SERS-active substrates are measured; topology is provided by atomic force microscope (AFM, Park Systems XE-100) and Raman spectra are collected by Raman spectroscopy (Horiba LabRAM ARAMIS Spectrometer). We anticipate that the results may open up various possibilities of applying flexible platform to highly sensitive Raman detection.

  • PDF

Simultaneous and Multi-frequency Driving System of Ultrasonic Sensor Array for Object Recognition

  • Park, S.C.;Choi, B.J.;Lee, Y.J.;Lee, S.R.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.582-587
    • /
    • 2004
  • Ultrasonic sensors are widely used in mobile robot applications to recognize external environments, because they are cheap, easy to use, and robust under varying lighting conditions. However, the recognition of objects using a ultrasonic sensor is not so easy due to its characteristics such as narrow beam width and no reflected signal from a inclined object. As one of the alternatives to resolve these problems, use of multiple sensors has been studied. A sequential driving system needs a long measurement time and does not take advantage of multiple sensors. Simultaneous and pulse coding driving system of ultrasonic sensor array cannot measure short distance as the length of the code becomes long. This problem can be resolved by multi-frequency driving of ultrasonic sensors, which allows multi-sensors to be fired simultaneously and adjacent objects to be distinguished. Accordingly, this paper presents a simultaneous and multi-frequency driving system for an ultrasonic sensor array for object recognition. The proposed system is designed and implemented using a DSP and FPGA. A micro-controller board is made using a DSP, Polaroid 6500 ranging modules are modified for firing the multi-frequency signals, and a 5-channel frequency modulated signal generating board is made using a FPGA. To verify the proposed method, experiments were conducted in an environment with overlapping signals, and the flight distances for each sensor were obtained from filtering of the received overlapping signals and calculation of the time-of-flights.

  • PDF

In vivo Imaging Flow Cytometer (세포 이미징 기능을 겸비한 생체 유세포 분석기)

  • Lee, Ho
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.1
    • /
    • pp.9-11
    • /
    • 2007
  • We introduce an in vivo imaging flow cytometer, which provides fluorescence images simultaneously with quantitative information on the cell population of interest in a live animal. As fluorescent cells pass through the slit of light focused across a blood vessel, the excited fluorescence is confocally detected. This cell signal triggers a strobe beam and a high sensitivity CCD camera that captures a snap-shot image of the cell as it moves down-stream from the slit. We demonstrate that the majority of signal peaks detected in the in vivo flow cytometer arise from individual cells. The instrument's capability to image circulating T cells and measure their speed in the blood vessel in real time in vivo is demonstrated. The cell signal irradiance variation, clustering percentage, and potential applications in biology and medicine are discussed.

Basic Physiological Research on the Wing Flapping of the Sweet Potato Hawkmoth Using Multimedia

  • Nakajima, Isao;Yagi, Yukako
    • Journal of Multimedia Information System
    • /
    • v.7 no.2
    • /
    • pp.189-196
    • /
    • 2020
  • We have developed a device for recording biological data by inserting three electrodes and a needle with an angular velocity sensor into the moth for the purpose of measuring the electromyogram of the flapping and the corresponding lift force. With this measurement, it is possible to evaluate the moth-physiological function of moths, and the amount of pesticides that insects are exposed to (currently LD50-based standards), especially the amount of chronic low-concentration exposure, can be reduced the dose. We measured and recorded 2-channel electromyography (EMG) and angular velocity corresponding to pitch angle (pitch-like angle) associated with wing flapping for 100 sweet potato hawkmoths (50 females and 50 males) with the animals suspended and constrained in air. Overall, the angular velocity and amplitude of EMG signals demonstrated high correlation, with a correlation coefficient of R = 0.792. In contrast, the results of analysis performed on the peak-to-peak (PP) EMG intervals, which correspond to the RR intervals of ECG signals, indicated a correlation between ΔF fluctuation and angular velocity of R = 0.379. Thus, the accuracy of the regression curve was relatively poor. Using a DC amplification circuit without capacitive coupling as the EMG amplification circuit, we confirmed that the baseline changes at the gear change point of wing flapping. The following formula gives the lift provided by the wing: angular velocity × thoracic weight - air resistance - (eddy resistance due to turbulence). In future studies, we plan to attach a micro radio transmitter to the moths to gather data on potential energy, kinetic energy, and displacement during free flight for analysis. Such physiological functional evaluations of moths may alleviate damage to insect health due to repeated exposure to multiple agrochemicals and may lead to significant changes in the toxicity standards, which are currently based on LD50 values.

Planar fuel cell design integrated with methanol reformer by using a high temperature membrane (고온형 멤브레인을 사용한 메탄올 개질 연료전지의 개질기 일체형 평판 설계)

  • Kim, Sung-Han;Jang, Jae-Hyuk;Gil, Jae-Hyoung;Lee, Hong-Ryul;Cha, Hye-Yeon;Ku, Bo-Sung;Jung, Chang-Ryul;Kundu, Arunaha;Miesse, Craig;Oh, Yong-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.467-470
    • /
    • 2006
  • For a mobile application such as cellular phone, micro fuel cells should be extremely compact and thin. RHFC can be an alternative solution because RHFC gives higher power density than DMFC and does not need ahydrogen storage vessel In this paper, RHFC using methanol fuel is made as a novel planar design without a PROX. Both reformer and cell are made closely in a same plate to share the heater of reformer with the cell. The PBI membrane is used in the cell. The reason is that high temperature of reformer can cause a performance drop when perfluorosulfonic acid membrane such as Nafion is used such a high temperature operation also guarantees the higher CO tolerance to MEA catalyst. The cell is designed as an air-breathing type which the cathode of the cell is opened to the air. The commercial Cu/ZnO/Al2O3 steam reformer catalyst is packed in reformer channel. The active area of MEA is $11.9cm^2$ and the peak power density was $27.5mW/cm^2$.

  • PDF

Fabrication of Micron-sized Organic Field Effect Transistors (마이크로미터 크기의 유기 전계 효과 트랜지스터 제작)

  • Park, Sung-Chan;Huh, Jung-Hwan;Kim, Gyu-Tae;Ha, Jeong-Sook
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.1
    • /
    • pp.63-69
    • /
    • 2011
  • In this study, we report on the novel lithographic patterning method to fabricate organic thin film field effect transistors (OTFTs) based on photo and e-beam lithography with well-known silicon technology. The method is applied to fabricate pentacene-based organic field effect transistors. Owing to their solubility, sub-micron sized patterning of P3HT and PEDOT has been well established via micromolding in capillaries and inkjet printing techniques. Since the thermally deposited pentacene cannot be dissolved in solvents, other approach was done to fabricate pentacene FETs with a very short channel length (~30 nm), or in-plane orientation of pentacene molecules by using nanometer-scale periodic groove patterns as an alignment layer for high-performance pentacene devices. Here, we introduce $Al_2O_3$ film grown via atomic layer deposition method onto pentacene as a passivation layer. $Al_2O_3$ passivation layer on OTFTs has some advantages in preventing the penetration of water and oxygen and obtaining the long-term stability of electrical properties. AZ5214 and ma N-2402 were used as a photo and e-beam resist, respectively. A few micrometer sized lithography patterns were transferred by wet and dry etching processes. Finally, we fabricated micron sized pentacene FETs and measured their electrical characteristics.

Time-Multiplexed RF Transmission to Improve $B_1$ Homogeneity in High Field MRI

  • Han, Byung-Hee;Seo, Jeung-Hun;Heo, Hye-Young;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.99-106
    • /
    • 2008
  • To improve $B_1$ homogeneity in high field MRI, the RF power is applied to the transmit array coil elements sequentially in the time-multiplexed way. Since only a single coil element is activated in a time-multiplexing slot, the global standing wave formation in the human body is greatly suppressed. The time-multiplexing slot width is on the order of micro seconds, hence, high-order-harmonic slices can be placed far from the transmit coil and simultaneous multiple slice selection can be avoided. The $B_1$ homogeneities of a birdcage coil and an eight-channel transmit array coil have been compared through finite difference time domain simulations. The simulation results indicate that the proposed technique can reduce the peak-to-peak $B_1$ inhomogeneity down to one fourth of the transmission with a birdcage coil on the central plane of the human head model at 3 T. The mimicking experiments at 3 T, eight separate experiments with a single coil element activated and image reconstruction by combining the eight images, also show promising results. It is expected that the proposed technique has some advantages over other $B_1$ improving methods in real practice since simple RF switching circuitries are only necessary and electromagnetic coupling between the coil elements is out of concern in its realization.

과학위성 1호 원자외선 분광기 비행 모형 발사 및 초기 운용

  • Yoo, Kwang-Sun;Lee, Dae-Hui;Oh, Seung-Han;Lee, Jin-Geun;Shin, Jong-Ho;Min, Kyung-Uk;Sun, Kwang-Il;Yuk, In-Su;Jin, Ho;Park, Jang-Hyun;Nam, Uk-Won;Han, Won-Yong;Edelstein, Jerry;Korpela, Eric
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.52-52
    • /
    • 2003
  • 1996년 미국 버클리 대학의 Space Science Laboratory와 공동으로 고온 성간 물질의 관측에 대한 Conceptual Study로부터 시작되어 1998년 과학위성 1호의 주 탑재체로 선정되면서 본격적인 개발에 들어간 원자외선 분광기(FIMS: Far-ultraviolet IMaging Spectrograph)는 Engineering Model 개발, Qualification Model 개발, Flight Model의 개발 및 보정, 그리고 최종적으로 과학기술위성 1호 본체와의 조립 시험 및 환경시험을 거쳐 2003년 9월 26일 러시아의 플레세츠크에서 COSMOS-3M 발사체에 의해 발사된다. FIMS를 포함한 과학위성 1호는 현재 발사를 위해 러시아 현지에 이송되어 최종 시험을 진행 중이며, 발사 후 약 20일 가량은 위성의 운용 시험을 하게 되며, 이후 FIMS의 운용에 영향을 줄 수 있는 Out-gassing이 충분히 이루어진 후 FIMS의 Test 및 초기 운용이 이루어 진다. FIMS의 Detector로 사용되는 MCP(Micro Channel Plate)의 정상적 동작이 확인되면, 1년여에 걸쳐 FIMS의 주 임무인 원자외선 영역(900∼1750')의 은하계 전천 탐사를 수행하게 된다. 전천 탐사가 마무리 되면, 전천탐사의 결과를 바탕으로 개별 천체의 영상 및 분광 자료를 획득하게 되며, 동시에 원자외선 영역의 오로라 및 지구 대기광 측정을 수행한다.