• 제목/요약/키워드: Micro channel

검색결과 612건 처리시간 0.028초

극저온 환경의 인쇄기판형 열교환기 열적성능에 대한 실험적 연구 (Experimental Study on the Thermal Performance of a Printed Circuit Heat Exchanger in a Cryogenic Environment)

  • 김동호;나상준;김영;최준석;윤석호
    • 설비공학논문집
    • /
    • 제27권8호
    • /
    • pp.426-431
    • /
    • 2015
  • The advantages of a printed circuit heat exchanger (PCHE) are the compactness and efficiency derived from its heat-transfer characteristics; furthermore, a PCHE for which a diffusion bonding method was used during production can be applied to extreme environments such as a cryogenic condition. In this study, a micro-channel PCHE fabricated by diffusion bonding was investigated in a cryogenic environment regarding its thermal performance and the pressure drop. The test rig consists of an LN2 storage tank, vaporizers, heaters, and a cold box, whereby the vaporized cryogenic nitrogen flows in hot and cold streams. The overall heat-transfer coefficients were evaluated and compared with traditional correlations. Lastly, we suggested the modified heat-transfer correlations for a PCHE in a cryogenic condition.

경원소 적층 분석을 위한 탄성되튐-비행시간 측정시스템 (An ERD-TOF System for the Depth Profiling of Light Elements)

  • 김영석;우형주;김준곤;김덕경;최한우;홍완
    • 한국진공학회지
    • /
    • 제5권1호
    • /
    • pp.25-32
    • /
    • 1996
  • An ERD-TOF system is constructed for the nondestructive depth profiling of light elements in thin films in the range of several thousand angstroms. The particles, recoiled by 10 $MeV^{35}Cl$ projectiles, were detected by a Time-Of-Flight spectrometer composed of a MCP (Micro Channel Plate) and a SSB (Silicon Surface Barrier) detector. A two parameter data acquisition system composed of two PC's was constructed for registering simultaneous time and energy signals. A $Si_3N_4$/poly-Si/$SiO_2$/Si sample was anlayzed and the result is compared with RBS. The detection limit, maximum probable depth and depth resolution for light elements in silicon are about $4\times10^{14}atoms/\textrm{cm}^2$, 5, 000$\AA$ and 100$\AA$, respectively.

  • PDF

무선 ATM 망에서 이동교환기간 빠른 핸드오버를 위한 동적 경로 예약 기법 (Dynamic Path Reservation Scheme for Fast Inter-switch Handover in Wireless ATM Networks)

  • 이봉주;이남석;안계현;김영천
    • 한국통신학회논문지
    • /
    • 제28권1A호
    • /
    • pp.7-16
    • /
    • 2003
  • 무선 ATM 망은 광대역 멀티미디어 서비스 제공을 위해 셀의 크기가 작은 마이크로/피코 셀 구조를 채택하므로 단말의 이동성 지원을 위한 핸드오버 기능은 매우 중요하다. 본 논문에서는 무선 ATM 망에서 이동교환기간 핸드오버를 신속하게 처리하기 위한 동적 경로 예약 핸드오버 기법을 제안한다 제안한 기법은 이동교환기간 핸드오버를 위해 최대근접공통노드로부터 인접 이동교환기까지 가상 채널을 미리 설정하므로 실제 핸드오버 시에 연결의 재라우팅에 소요되는 시간을 단축할 수 있다 특히 일정 주기마다 예측 알고리즘을 수행하여 다음 주기에 발생할 핸드오버 호의 수를 예측하여 가상 채널을 예약함으로써 기존 DVCT 기법에 비하여 예약 채널 수, 예약 채널 이용률 및 시그널링 복잡성을 개선하였다.

고해상도 심전계의 개발 (Development of a High-Resolution Electrocardiography)

  • 이호성;우응제;박승훈;이종민;박광석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.179-183
    • /
    • 1996
  • Most of the conventional electrocardiogaphies fail to detect signals other than P-QRS-T due to the limited SNR and bandwidth. High-resolution electrocardiography (HRECG) provides better SNR and wider bandwidth for the detection of micro-potentials with higher frequency components such as ventricual late potentials(LP). In this paper, we developed a HRECG using uncorrected XYZ lead. The overall gain of the amplifier is 4000 and the bandwidth is $0.5{\sim}300Hz$ without using 60Hz notch filter. Three 16-bit AH converters sample X, Y, and Z signals simultaneously with a sampling frequency of 2000Hz. Sampled data are transmitted to PC via a DMA-controlled serial communication channel using RS-485 and HDLC protocol. The noise level of the developed HRECG is less than $5{\mu}V_{rms,\;RTI}$. In order to further reduce the noise level, signal averaging technique is implemented utilizing template matching method. The SNR of the developed HRECG is high enough for the detection of LP.

  • PDF

유전-전기영동 기반 입자 편향에 관한 3차원 시뮬레이션 및 실험 (3-D Simulation and Experiment on Particle Deflection by Dielectrophoresis)

  • 김민수;김민수;서영태;김종호;이윤식;임건규;이향범;박재형;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.146-147
    • /
    • 2007
  • We present full 3-D simulation of dielectrophoretic (DEP) deflection of particle trajectory in micro channel and compare the simulation results with experimental results. In simulation, the particle 3-D movements along x, y and z-axis are simulated precisely, and the streamlines of particles movements and the change of particle height are investigated experimentally. Therefore, the deflection performance is investigated on the designed and fabricated deflection microchip.

  • PDF

다층셀 구조를 갖는 이동통신환경에서의 핸드오버 성능분석 (Performance Analysis for the Handover in Mobile Communication Environment with Multilayered Cell Structure)

  • 임석구
    • 한국산학기술학회논문지
    • /
    • 제8권1호
    • /
    • pp.73-81
    • /
    • 2007
  • 본 논문에서는 마이크로 셀과 매크로 셀이 중첩된 구조를 갖는 이동통신 환경에서 핸드오버의 성능을 분석하였다. 제안한 모델에서는 고속으로 이동하는 가입자를 마이크로 셀로 핸드오버하지 않고 매크로 셀로 핸드오버하는 경우의 성능을 분석하였다. 분석의 용이함을 위해 마이크로 셀과 매크로 셀의 모양은 원형이라고 가정하였다. 마이크로 셀에는 저속의 핸드오버 호를 위하여 큐를 두는 방식과 매크로 셀에는 고속의 핸드오버 호를 위하여 예약채널 할당방식을 적용하였다 해석적인 분석결과, 제안한 방식에서 새로운 호의 블러킹 확률의 증가는 미비하면서 랜드오버 실패 확률은 중첩되지 않은 셀 구조를 갖는 시스템에 비해 상대적으로 낮음을 알 수 있었다.

  • PDF

Study on Bead-based Microbiochip and Analytical System for Protein Detection

  • Kim, Min-Soo;Chung, Woo-Jae;Cho, Su-Hyung;Park, Sung-Soo;Kim, Byung-Gee;Lee, Young-Sik;Kim, Yong-Kweon
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.60-63
    • /
    • 2002
  • This paper presents bead-based microbiocihps to detect and separate target proteins. Micro beads coated with capture proteins were introduced into a microchamber, and target proteins flowing across the chamber were bound and concentrated. The chip was connected with an external fluid system. Bead surfaces were double-coated with photo-cleavable linkers and capture proteins. The proteins bound on the beads were photo-separated under UV irradiation, and excited to be measured in fluorescence. $38{\sim}50{\mu}m$ sized polystyrene beads were used. SOGs(silicon-on-glass) were used to fabricate the microchip having glasses bonded on both sides. 100 ${\mu}m$ thick silicon channel was formed through silicon deep RIE process. The upper glass cover had holed through to have inlets and outlets fabricated by powder-blastings. In this study, biotin and streptavidin were used as capture proteins and detection proteins, respectively. The protein mixtures of streptavidin, HSA(human serum albumin) and ovalbumin were applied for selective detection test.

  • PDF

소형공작기계를 이용한 광커넥터용 V 홈 가공에 관한 연구 (A Study on Machining of A V-groove on the Optical Fiber Connector Using a Miniaturized Machine Tool)

  • 이재하;박성령;양승한;이영문
    • 한국정밀공학회지
    • /
    • 제21권5호
    • /
    • pp.38-45
    • /
    • 2004
  • As optical communication is being substituted for telecommunication, the demand of a large variety of fiber optic components is increasing. V-groove substrates, one of the module components, are used to connect optical fibers to optical planar circuits and to arrange fibers. Their applications are multi-channel optical connectors and optical waveguide fiber coupling, etc. Because these substrates are a critical part of the splitter in a multiplexer and a multi fiber connector, precise and reliable fabrication process is required. For precisely aligning core pitch between fibers, machined core pitch tolerance should be within sub-microns. Therefore, these are generally produced by state-of-the-art micro-fabrication like MEMS. However, most of the process equipment is very expensive. It is also difficult to change the process line for custom designs to meet specific requirements using various materials. For various design specifications such as different values of the V angle and low-priced process, the fabrication method should be flexible and low cost. To achieve this goal, we have suggested a miniaturized machine tool with high accuracy positioning system. Through this study, it is shown that this cutting process can be applied to produce V-groove subtracts. We also show the possibility of using a miniaturized machining system for producing small parts.

Modified droop control scheme for load sharing amongst inverters in a micro grid

  • Patel, Urvi N.;Gondalia, Dipakkumar;Patel, Hiren H.
    • Advances in Energy Research
    • /
    • 제3권2호
    • /
    • pp.81-95
    • /
    • 2015
  • Microgrid, which can be considered as an integration of various dispersed resources (DRs), is characterized by number of DRs interfaced through the power electronics converters. The microgrid comprising these DRs is often operated in an islanded mode. To minimize the cost, reduce complexity and increase reliability, it is preferred to avoid any communication channel between them. Consequently, the droop control method is traditionally adopted to distribute active and reactive power among the DRs operating in parallel. However, the accuracy of distribution of active and reactive power among the DRs controlled by the conventional droop control approach is highly dependent on the value of line impedance, R/X i.e., resistance to reactance ratio of the line, voltage setting of inverters etc. The limitations of the conventional droop control approach are demonstrated and a modified droop control approach to reduce the effect of impedance mis-match and improve the time response is proposed. The error in reactive power sharing is minimized by inserting virtual impedance in line with the inverters to remove the mis-match in impedance. The improved time response is achieved by modifying the real-power frequency droop using arctan function. Simulations results are presented to validate the effectiveness of the control approach.

스마트 폰 기반 3D 프린팅 칩을 이용한 적혈구 변형성 측정 (Measurement of RBC (red blood cell) deformability using 3D Printed Chip combined with Smartphone)

  • 이수환;홍현지;염은섭;송재민
    • 한국가시화정보학회지
    • /
    • 제18권3호
    • /
    • pp.103-108
    • /
    • 2020
  • RBC (red blood cell) deformability is one of factors inducing blood shear thinning effect. Reduction of RBC deformability increases blood viscosity in high shear region. In this study, 3D printed chip with proper distribution of wall shear rate (WSR) was proposed to measure RBC deformability of blood samples. To fabricate 3D printed chip, the design of 3D printed chip determined through numerical simulation was modified based on the resolution of the 3D printer. For the estimation of pressure drop in the 3D printed chip, two bypass outlets with low and high WSR are exposed to atmospheric pressure through the needles. By positioning the outlet of needles in the gravity direction, the formation of droplets at bypass outlets can be captured by smartphone. Through image processing and fast Fourier transform (FFT) analysis, the frequency of droplet formation was analyzed. Since the frequency of droplet formation is related with the pressure at bypass, high pressure drop caused by reduction of RBC deformability can be estimated by monitoring the formation of blood droplets using the smartphone.