The non-vital bleaching technique has been used widely as a very effective treatment method on discolored non-vital teeth. But periodontal tissue deterioration and cervical external root resorption have been reported because of the high toxicity of hydrogen peroxide in bleaching agents. So in previous studies, placement of base over the root canal obturation prior to bleaching has been suggested in order to prevent microleakage of bleaching agents, however, the effectiveness of base is still controversial. The purpose of this study was to evaluate the effects of base and root canal sealer on prevention of leakage of bleaching agents in non-vital bleaching. Fifty-two extracted sound teeth with single root were used. For root canal obturation, Tubuli seal$^{(R)}$(Kerr Co., USA) was used in 39 teeth and in others, AH-26$^{(R)}$(De Trey Dentsply, Inc., Switzerland) was used as a root canal sealer. 26 teeth among the teeth obturated with Tubuli seal$^{(R)}$ were divided into two groups, and Dentin cement$^{(R)}$(GC corp., Japan) and JRM$^{(R)}$(De Trey Dentsply, Inc. Germany) were used in each group as a intracanal base. In all teeth, non-vital bleaching using bleaching agent mixed with methylene blue dye was performed and all specimens were stored in $37^{\circ}C$ water bath for 72 hours. After sectioning longitudinally, the depth of dye leakage was measured with digital vernier calipers under the stereobinocular microscope using ${\times}40$ magnification. It can be concluded as follows: 1. The microleakage of bleaching agent was observed ill all groups regardless of type of the base and the sealer. 2. The microleakage in the groups using AH-26$^{(R)}$ as a sealer was significantly reduced (p<0.05). 3. In the groups with intracanal base, micro leakage was observed through almost the whole depth of the base and there was no significant difference between Dentin cement$^{(R)}$ and IRM$^{(R)}$ group(p>0.05). In conclusion, all the basing materials and the sealers in this study did not prevent the microleakage of bleaching agent. Therefore further studies and attempts to seal off the pulp chamber will be necessary.
Proceedings of the Korean Society for Bioinformatics Conference
/
2006.02a
/
pp.46-55
/
2006
(주)지노믹트리는 DNA 마이크로어레이 기술을 기반으로 하는 분자진단회사로서, 다음의 세가지 사업에 전력하고 있다. 첫째는 독창적이며 특화된 바이오마커 발굴기술 (MAGIC system)을 바탕으로 각종 암진단을 위한 바이오마커 개발연구 두 번째는 당사의 원천 기술인 다중동시검출 시스템을 이용한 질병 진단 시스템 및 증폭시스템 세 번째는 마이크로어레이 기술을 이용한 유전자 발현 분석, Array CGH, DNA 메틸레이션 분석 그리고 miRNA 검출 등의 지노믹스시대의 연구를 위한 토탈솔루션을 제공하고 있다. 지난 5년간의 마이크로어레이 기반기술을 이용한 자체연구 활동을 수행하면서 축적된 마이크로어레이 관련기술 노-하우들을 국내 마이크로어레이 연구자들에게 공급하기 위하여 노력하고 있다. 특히 당사의 지노믹서비스 부문은 유전자 발현 분석 솔루션 제공을 위해서 자체적으로 제작하여 공급하고 있는 human cDNA(17K/25K) 및 rat cDNA (5.0K) 마이크로어레이, Human (22K) 및 mouse (10K) 올리고뉴클레오타이드 마이크로 어레이 그리고 미생물 연구를 위한 대장균 (6K) 및 폐렴균 (2.2K) 올리고뉴클레오타이드 마이크로어레이 제공 및 이를 이용한 유전자 발현 분석 서비스를 제공하고 있다. 체적으로 제작되는 마이크로어레이 서비스는 2001년 도입한 ISO9001 품질인증시스템의 기반하에서 제작부터 생산까지의 엄격한 품질관리 과정을 거쳐서 고품질의 마이크로어레이를 이용한 분석서비스를 제공 하고 있다. 또한 고객요구형 서비스를 위하여 국외 유수의 마이크로어레이 회사 (Agilent, Microarray Inc, TIGR, Eurogentec 등)의 whole genome 기반의 마이크로어레이 제품을 이용한 분석서비스를 제공하고 있으며 마이크로어레이 실험을 위해서 필수적으로 이용되고 있는 시약 (labeling kit), 마이크로어레이 hybridization을 위한 hardware (hybridization chamber, hnay centrifuge)등을 자체적으로 개발하여 공급하고 있다. DNA copy number 측정을 위한 Array CGH 분석을 위해서는 자체적으로 제작공구하고 있는 human cDNA 마이크로어레이 (17K/25K) 그기고 rat (5.0K) 마이크로어레이를 이용한 분석서비스 및 whole genome 기반의 Agilent 올리고뉴클레오타이드 CGH 어레이 (44K, 35Kb resolution)를 이용한 분석서비스를 제공하고 있다. Epigenetic study를 하는 연구자들을 위한 메틸레이션 마이크로어레이 분석 서비스를 제공하고 있다. 기존분석법인 Bisulfite 처리기반의 분석이 아닌 enzyme digestion후 PCR 증폭방법을 이용한 분석방법을 이용함으로써, bisulfite 처리에 의한 DNA 손실문제를 최소화 하였다. 현재 50개의 문헌을 통해 잘 보고된 메틸레이션 유전자들에 대한 분석서비스를 제공하고 있으며, 지속적으로 표적컨텐츠의 숫자를 증가시킬 예정이다. 최근 많은 연구자들의 관심을 끌고 있는 micro RNA 검출을 위한 DNA 마이크로어레이 서비스를 제공할 예정이다 (2006년 3월 출시). 현재 까지 알려진 약 320개의 모든 miRNA를 탑재하고 있는 소형 DNA 마이크로어레이를 이용한 분석서비스로서 1장의 마이크로어레이 실험을 통하여 알려진 모든 miRNA의 비교분석이 가능하다. 마이크로어레이 실험 뿐만 아니라 data 분석을 위한 software도 상당히 중요한 비중을 차지하고 있다 이를 위하여 (주)지노믹트리는 Agilent에서 개발한 GeneSpring GX (유전자 발현 분석), Signet (마이크로어레이 database) 및 GeneSpring GT (SNP 분석)를 공급하고 있다. 통계적인 기반 지식의 없은 일반 user들을 위한 간편하면서도 종합적인 기능을 포함하고 있는 우수한 프로그램으로 이미 국제적으로 많은 인정을 받고 있다. (주)지노믹트리는 국내외 많은 연구자들의 경제적, 시간적 연구여건을 고려한 마이크로어레이 토탈솔루션을 제공하고 있으며, 실험 분석에서 data 마이닝 그리고 마이크로어레이 실험 디자인에 이르는 토탈솔루션을 제공하고 있다.
In this work, micro-sized dextran particles, which have recently been focused as one of the candidate materials for the Drug Delivery System(DDS), were prepared by means of the Supercritical Antisolvent (SAS) process with $CO_2$. With dimethyl sulfoxide(DMSO) as the solvent, effects of the operating variables such as temperature (308.15~323.15 K), pressure(90~130 bar), solute concentration(10~20 mg/ml), and the molecular weight of the solute(Mw=37,500, 450,000) on the size and morphology of the resulting particles were thoroughly observed. The higher solute concentration led to the larger particles, however, the injection velocity of the solution and pressure did not show significant effects on the resulting particle size. With dextran of the lower molecular weight, the smallest particles were obtained at 313.15 K. On the other hand, the size of the particles from the high molecular weight dextran ranged between $0.1{\sim}0.5{\mu}m$ with an incremental effect of the temperature and pressure. For the solute concentration of 5 mg/ml, the lower molecular weight dextran did not form discrete particles while aggregation of the particles appeared when the solute concentration exceeded 15 mg/ml for the higher molecular weight dextran. It is believed that if the solute concentration is too low, the degree of the supersaturation in the recrystallization chamber would not be sufficient for initiation of the nucleation and growth mechanism. Instead, the spinodal decomposition mechanism leads to formation of the island-like phase separation which appears similar to aggregation of the discrete particles. This effect would be more pronounced for the smaller molecular weight polymer system due to the narrower phase-splitting region.
Proceedings of the Korean Vacuum Society Conference
/
2000.02a
/
pp.195-195
/
2000
TFT-LCD의 제조공정은 박막층의 식각 공정에 대해 기존의 습식 공정을 대치하는 건식식각이 선호되고 있다. 건식 식각 공정은 반도체 공저에 응용되면서 소자의 최소 선폰(CD)이 감소함에 따라 유도결합셩 프라즈마를 비롯한 고밀도 플라즈마 이용한 플라즈마 장비 사용이 증가하는 추세이다. 여기에 평판디스플레이의 공정을 위해서는 대면적과 사각형 기판에 대한 균일도를 보장할 수 있는 고밀도의 균일한 플라즈마 유지가 중요하다. 본 실험에서는 자장강화된 유도결합형 플라즈마의 플라즈마 밀도 및 균일도를 살펴보고 TFT-LCD에 gate 전극으로 사용되는 Al-Nd 박막의 식각을 통하여 식각균일도와 식각속도 및 식각 선택도 등의 건식 식각 특성을 보고자 한다. 영구자석 및 전자석의 설치는 사각형의 유도결합형 플라즈마는 소형 영구자석을 배열하여 부착하였으며, 외부에는 chamber와 같이 사각형태의 전자석을 500mm$\times$500mm의 크기를 갖는 z축 방향의 Helmholtz형으로 제작하였다. 더. 영구자석 배열에 대해서는 자석간의 거리와 세기 변화를 조합하여 magnetic cusping의 변화를 주었으며 전자석의 세기는 전류값을 기준으로 변화시켜 보았다. 실험을 통하여 플라즈마 균일도를 5% 이하로 개선하고 이러한 균일도를 유지하며 플라즈마 밀도를 높일 수 있는 조건을 찾을 수 있었다. 이러한 적합화된 조건에서 저장강화된 유도결합형 프라즈마를 Al-Nd 박막 식각에 응용한 결과, Al-Nd의 식각속도 및 식각 선택도는 유도결합형 프라즈마에 비해 크게 증가하였으며, 식각균일도가 개선되는 것을 관찰하였다. 또한 electrostatic probe(Hiden, Analytical)를 이용하여 Al-Nd 식각에 사용된 반응성 식각가스에 대한 저장강화된 유도결합형 플라즈마의 특성 분석을 수행하였다.c recoil detection, Rutherford backscattering spectroscopy, X-ray diffraction, secondary electron microscopy, atomic force microscoy, $\alpha$-step, Raman scattering spectroscopu, Fourier transform infrared spectroscopy 및 micro hardness tester를 이용하여 기판 bias 전압이 DLC 박막의 특성에 미치는 영향을 조사하였다. 분석결과 본 연구에서 제작된 DLC 박막은 탄소와 수소만으로 구성되어 있으며, 비정질 상태임을 알 수 있었다. 기판 bias 전압의 증가에 따라 박막의 두께가 감소됨을 알 수 있었고, -150V에서는 박막이 거의 만들어지지 않았으며, -200V에서는 기판 표면이 식각되었다. 이것은 기판 bias 전압과 ECR 플라즈마에 의한 이온충돌 효과 때문으로 판단되며, 150V 이하에서는 증착되는 양보다 re-sputtering 되는 양이 더 많을 것으로 생각된다. 기판 bias 전압을 증가시킬수록 플라즈마에 의한 이온충돌 현상이 두드러져 탄소와 결합하고 있던 수소원자들이 떨어져 나가는 탈수소화 (dehydrogenation) 현상을 확인할 수 있었으며, 이것은 C-H 결합에너지가 C-C 결합이나 C=C 결합보다 약하여 수소 원자가 비교적 해리가 잘되므로 이러한 현상이 일어난다고 판단된다. 결합이 끊어진 탄소 원자들은 다른 탄소원자들과 결합하여 3차원적 cross-link를 형성시켜 나가면서 내부 압축응력을 증가시키는 것으로 알려져 있으며, hardness 시험 결과로 이것을 확인할 수 있었다. 그리고 표면거칠기는 기판 bias 전압을 증가시킬수록 더 smooth 해짐을 확인하였다.인하였다.을 알 수 있
The purpose of this study is to develop the optimization method for adjusting the film isocenter shift and to suggest the quantitative acceptable criteria for film dosimetry after optimization In the dynamic conformal arc radiation therapy (DCAR). The DCAR planning was peformed In 7 patients with brain metastasis. Both absolute dosimetry with ion chamber and relative film dosimetry were peformed throughout the DCAR using BrainLab's micro-multileaf collimator. An optimization method for obtaining the global minimum was used to adjust for the error in the film isocenter shift, which is the largest pan of systemic errors. The mean of point dose difference between measured value using ion chamber and calculated value acquired from planning system was $0.51{\pm}0.43\%$ and maximum was $1.14\%$ with absolute dosimetry These results were within the AAPM criteria of below $5\%$. The translation values of film isocenter shift with optimization were within ${\pm}$1 mm in all patients. The mean of average dose difference before and after optimization was $1.70{\pm}0.35\%$ and $1.34{\pm}0.20\%$, respectively, and the mean ratios over $5\%$ dose difference was $4.54{\pm}3.94\%$ and $0.11{\pm}0.12\%$, respectively. After optimization, the dose differences decreased dramatically and a ratio over $5\%$ dose difference and average dose difference was less than $2\%$. This optimization method is effective in adjusting the error of the film isocenter shift, which Is the largest part of systemic errors, and the results of this research suggested the quantitative acceptable criteria could be accurate and useful in clinical application of dosimetric verification using film dosimetry as follows; film isocenter shift with optimization should be within ${\pm}$1 mm, and a ratio over $5\%$ dose difference and average dose difference were less than $2\%$.
We studied plasma etching of polycarbonate in $O_2/SF_6$, $O_2/N_2$ and $O_2/CH_4$. A capacitively coupled plasma system was employed for the research. For patterning, we used a photolithography method with UV exposure after coating a photoresist on the polycarbonate. Main variables in the experiment were the mixing ratio of $O_2$ and other gases, and RF chuck power. Especially, we used only a mechanical pump for in order to operate the system. The chamber pressure was fixed at 100 mTorr. All of surface profilometry, atomic force microscopy and scanning electron microscopy were used for characterization of the etched polycarbonate samples. According to the results, $O_2/SF_6$ plasmas gave the higher etch rate of the polycarbonate than pure $O_2$ and $SF_6$ plasmas. For example, with maintaining 100W RF chuck power and 100 mTorr chamber pressure, 20 sccm $O_2$ plasma provided about $0.4{\mu}m$/min of polycarbonate etch rate and 20 sccm $SF_6$ produced only $0.2{\mu}m$/min. However, the mixed plasma of 60 % $O_2$ and 40 % $SF_6$ gas flow rate generated about $0.56{\mu}m$ with even low -DC bias induced compared to that of $O_2$. More addition of $SF_6$ to the mixture reduced etch of polycarbonate. The surface roughness of etched polycarbonate was roughed about 3 times worse measured by atomic force microscopy. However examination with scanning electron microscopy indicated that the surface was comparable to that of photoresist. Increase of RF chuck power raised -DC bias on the chuck and etch rate of polycarbonate almost linearly. The etch selectivity of polycarbonate to photoresist was about 1:1. The meaning of these results was that the simple capacitively coupled plasma system can be used to make a microstructure on polymer with $O_2/SF_6$ plasmas. This result can be applied to plasma processing of other polymers.
Kim, Deok-Joong;Song, Yong-Beom;Park, Sang-Hee;Kim, Hyoung-Sun;Lee, Hye-Yoon;Yu, Mi-Kyung;Lee, Kwang-Won
Journal of Dental Rehabilitation and Applied Science
/
v.29
no.1
/
pp.37-44
/
2013
Sodium hypochlorite and ethylene diamine tetra acetic acid are substances usually used during endodontic treatment. Several studies found that the bonding was negated with certain irrigants and some of the used irrigants have demineralizing and chealating effects, so it was advocated to omit the etching step in etch and rinse adhesive systems. The purpose of this in vitro study was to evaluate the influence of NaOCl & EDTA on the bonding strength of ethanol wet bonding. Thirty human molars were selected and mesiodistally sectioned into halves, thus providing sixty specimens. The specimens were randomly assigned to 4 groups(n=15) according to the irrigant regimen used : (1) irrigated with distilled water for 10min (control); (2) irrigated with 5.25% NaOCl(10min), flushed with 5.25% NaOCl(1min) (3) irrigated with 5.25% NaOCl, flushed with 17% EDTA (4) irrigated with 5.25% NaOCl, flushed with 17% EDTA. Each group was acid-etched with 37% phosphoric acid(except group 4) and had their dentin surfaces dehydrated with ethanol solutions : 50%, 70%, 80%, 95%, 3x100%, 30s for each application. After dehydration, a primer( 50% all bond 3 resin + 50% ethanol) was used, followed by the adhesive(ALL-BOND 3 RESIN) application. Resin composite build-ups were then prepared using an incremental technique. Specimens were sectioned into beams and submitted to a tensile load using a Micro Tensile Tester(Bisco Inc.). The data were statistically analyzed using one-way ANOVA and Tukey HSD at p<0.5 level. There was no significant difference on G1(control) and G2(irrigated with NaOCl only ). (p>0.05). G3(flushed with EDTA) showed significantly high tensile bonding strength compared to the G2 (p<0.05). G4( treated with EDTA but no acid-etching) was significantly lower value than G3. (p<0.05) Although there was no significant difference, 5.25% NaOCl seemed to have an adverse effect on the bonding strength of ethanol wet bonding. The flushing with EDTA after NaOCl irrigation prevents the decrease of bonding strength. The use of 17% EDTA as a final flush can enhance the bonding strength but EDTA flushing can't substitute for a acid-etching.
Since ${\beta}-aminoethylphosphonic$ acid was discovered in the living organism, the biosynthesis and biological function of aminophosphonic acids have been extensively studied. The purpose of this project consists in the two parts: 1)the preparation of DL-1-amino-2-phenylethylphosphonic acid (Phenylalanine aminophosphonic acid) and DL-1-amino-3-methylbutyl-phosphonic acid (Isoleucine aminophosphonic acid) by the method of Chamber and Isbell. 2) the study of metabolism and biological functions of those synthetic materials by the animal experiment (white rats) The importance of this project proved to be the first experience fed by animals for the elucidation of biochemical and metabolic functions in the animal body. The following organic synthesis of DL-1-amino-3-methylbutylphosphonic acid and DL-1-amino-2-phenylethylphosphonic acid are studied. 1)Synthesis of DL-1-amino-3-methylbutylphosphonic acid a) Synthesis of Iso-butylbromide b) Synthesis of Ethyl iso-butylmalonate c) Synthesis of Iso-caproic acid d) Synthesis of $Ethyl-{\alpha}-bromo$ iso-caproate e) Synthesis of $Triethyl-{\alpha}-phosphono$ iso-caproate f) Synthesis of DL-1-amino-3-methylbutylphosphonic acid 2)Synthesis of DL-1-amino-2-phenylethylphosphonic acid a) Synthesis of Diethyl phosphite b) Synthesis of Ethylchloro acetate c) Synthesis of Triethyl phospho acetate d) Synthesis of Triethyl benzyl phospho acetate e) Synthesis of DL-1-amino-2-phenylethylphosphonic acid The synthetic compounds; DL-1-amino-3-methylbutylphosphonic acid and DL-1-amino-2-phenyl ethylphosphonic acid which are essential amino acid (isoleucine, phenylalanine)analogue are supplemented to the animal diet at the level of 0.2% and 0.4% for isoleucine analogue and 0.35% and 0.7% for phenylalanine analogue. The plain isoleucine and phenylalanine at the same level in the diet are fercilitated as comparable groups in this study. Two sets of experience including 100 male rats were carried out for seven weeks each total 14 weeks. During this period, urine samples, and each big organs were collected for the analysis of total nitrogen, phosphorus, and glycogen contents in the individual samples by Micro Kjeldahl Fisk & Subbarow and Nelson Somogye, method. 1) The result of the project a) The yield of DL-1-amino-3-methylbutylphosphonic acid and DL-1-amino-2-phenylethylphosphonic acid showed low tendency at the level of 12.5% and 20% Melting point of those two compounds were very high and the ${\alpha}-amino$ group in the synthetic compounds showed positive reaction with ninhydrin in the violet color. b) Ail the experimental groups included in this study revealed statistically no significant difference in the organ weight, total body nitrogen retention and urinary phosphorus excretion This means isoleucine aminophosphonic acid and Phenylalanine aminophosphonic acid were utilized in the body as much as the plain amino acids, isoleucine and phenylalanine did. c) The glycogen contents in the liver of the phenylalaine aminophosphonic acid gruop showed higher statistically significant(p<0.05) in the comparision with the group of the Phenylalanine and the Standard-2. It was noteworthy that the higher glycogen content in the liver might indicate the significance in the incorporation of phenylalanine aminophosphonic acid into the intermediate of tricarboxylic acid cycle as activated state.
The samples composed of a GST thin film and the protective layers of $ZnS-SiO_2$ or $Al_2O_3$ coated on c-Si substrate were prepared by using the magnetron sputtering method. Samples of three different structures were prepared, that is, i) the GST single film on c-Si substrate, ii) the GST film sandwiched by the protective $ZnS-SiO_2$ layers on c-Si substrate, and iii) the GST film sandwiched by $Al_2O_3$ protective layers on c-Si substrate. The ellipsometric constants in the temperature range from room temperature to $700^{\circ}C$ were obtained by using the in-situ ellipsometer equipped with a conventional heating chamber. The measured ellipsometric constants show strong variations versus temperature. The variation of ellipsometric constants at the temperature region higher than $300^{\circ}C$ shows different behaviors as the ambient medium is changed from in air to in vacuum or the protective layers are changed from $ZnS-SiO_2$ to $Al_2O_3$. Since the long heating time of 1-2 hours is believed to be the origin of the high temperature variation of ellipsometric constants upon the heating environment and the protective layers, a PRAM (Phase-Change Random Access Memory) recorder is introduced to reduce the heating time drastically. By using the PRAM recorder, the GST samples are heated up to $700^{\circ}C$ decomposed preventing its partial evaporation or chemical reactions with adjacent protective layers. The surface image obtained by SEM and the surface micro-roughness verified by AFM also confirmed that samples prepared by the PRAM recorder have smoother surface than the samples prepared by using the conventional heater.
Ahn Yong Chan;Cho Byung Chul;Choi Dong Rock;Kim Dae Yong;Huh Seung Jae;Oh Do Hoon;Bae Hoonsik;Yeo In Hwan;Ko Young Eun
Radiation Oncology Journal
/
v.18
no.2
/
pp.150-156
/
2000
Purpose : Stereotactic radiation therapy (SRT) can deliver highly focused radiation to a small and spherical target lesion with very high degree of mechanical accuracy. For non-spherical and large lesions, however, inclusion of the neighboring normal structures within the high dose radiation volume is inevitable in SRT This is to report the beam shaping using the partial closure of the independent jaw in SRT and the verification of dose calculation and the dose display using a home-made soft ware. Materials and Methods : Authors adopted the idea to partially close one or more independent collimator jaw(5) in addition to the circular collimator cones to shield the neighboring normal structures while keeping the target lesion within the radiation beam field at all angles along the arc trajectory. The output factors (OF's) and the tissue-maximum ratios (TMR's) were measured using the micro ion chamber in the water phantom dosimetry system, and were compared with the theoretical calculations. A film dosimetry procedure was peformed to obtain the depth dose profiles at 5 cm, and they were also compared with the theoretical calculations, where the radiation dose would depend on the actual area of irradiation. Authors incorporated this algorithm into the home-made SRT software for the isodose calculation and display, and was tried on an example case with single brain metastasis. The dose-volume histograms (DVH's) of the planning target volume (PTV) and the normal brain derived by the control plan were reciprocally compared with those derived by the plan using the same arc arrangement plus the independent collimator jaw closure. Results : When using 5.0 cm diameter collimator, the measurements of the OF's and the TMR's with one independent jaw set at 30 mm (unblocked), 15.5 mm, 8.6 mm, and 0 mm from th central beam axis showed good correlation to the theoretical calculation within 0.5% and 0.3% error range. The dose profiles at 5 cm depth obtained by the film dosimetry also showed very good correlation to the theoretical calculations. The isodose profiles obtained on the home-made software demonstrated a slightly more conformal dose distribution around the target lesion by using the independent jaw closure, where the DVH's of the PTV were almost equivalent on the two plans, while the DVH's for the normal brain showed that less volume of the normal brain receiving high radiation dose by using this modification than the control plan employing the circular collimator cone only. Conclusions : With the beam shaping modification using the independent jaw closure, authors have realized wider clinical application of SRT with more conformal dose planning. Authors believe that SRT, with beam shaping ideas and efforts, should no longer be limited to the small spherical lesions, but be more widely applied to rather irregularly shaped tumors in the intracranial and the head and neck regions.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.