디지털 방사선 투과영상의 식별도 평가 연구 (The Study on Image Sensitivity Evaluation For Digital Radiography Image)

  • 박상기;이영호
    • 동력기계공학회지
    • /
    • 제12권6호
    • /
    • pp.70-77
    • /
    • 2008
  • The purpose of this study is to compare the quality of digital radiography image with that of classical film images for welded structure in power plants. The CMOS(Complementary Metal Oxide Semiconductor) flat panel detecter and Agfa D5 film are used to image flaw specimens respectively. In the test, CMOS flat panel detector has been determined to have a better image than that of film image. In the IQI(Image Quality Indicator) transmission test, one or two more line can be seen in digital image than in film image. Digital Radiography Test enabled to successfully detect all defects on the weld specimens fabricated with real reheat stem pipe and boiler tube as well. In the specific comparison test, Digital radiography test detected micro flaws in the size of 0.5 mm in length by 0.5 mm in depth. However, film test has limited it to 1.0 mm in length by 1.0 mm in depth. As a result of this study, digital radiography technology is estimated well enough to perform the inspection in the industry with far more cost effective way, compared to the classical film test.

  • PDF

CMOS 직사각형 나선 인덕터의 기하학적 변화에 따른 전자기적 특성에 관한 연구 (Investigation on the Electromagnetic Characteristics of CMOS Rectangular Spiral Inductors according to the Geometrical Change)

  • 진경신;김영식
    • 대한전자공학회논문지TC
    • /
    • 제41권12호
    • /
    • pp.125-130
    • /
    • 2004
  • 본 논문에서는 EM field 시뮬레이션을 통한 CMOS 공정의 온-칩 직사각형 나선 구조의 인덕터 특성을 보여 주고있다. EM field 시뮬레이션을 위해서 ADS 모멘텀을 사용하였으며, 실제 검증은 하이닉스 0.35㎛ CMOS 공정을 이용하여 인덕터를 제작, 측정하였다. 이 연구에서는 일반 CMOS 공정에서의 전송선로의 넓이, 턴 횟수와 같은 기하학적인 변화에 따른 인덕터의 특성이 조사되었다. 실험과 시뮬레이션 결과는 거의 일치하였으며 5이하의 Q- factor를 가질 때 1nH에서 6nH의 인덕턴스 분포를 가지는 것을 확인할 수 있었다.

갈바어닐링온도변화가 합금화용융아연코팅의 합금상과 마찰특성에 미치는 영향 (Effects of Galvannealing Temperatures on Iron-Zn Intermetallic Compounds and Friction Characteristic of Galvannealed Coatings)

  • 이정민;김동환;이선봉;김동진;김병민
    • 대한기계학회논문집A
    • /
    • 제32권12호
    • /
    • pp.1107-1114
    • /
    • 2008
  • This paper is aimed to understand the effect of different galvannealing temperatures on the frictional properties and Fe-Zn intermetallic phases of the galvannealed (GA) coatings on steel sheets. Their galvannealing treatments were conducted at 465, 505, 515 and $540^{\circ}C$ for about 10s in the additional heating furnace of an industrial continuous hot-dip galvanizing line. The mechanical and the frictional properties of the coatings were estimated using nanoindentation, nanoscratch, micro vickers hardness tests and flat friction tests, which were performed at contact pressures of 4, 20 and 80MPa. Also, the correlation between the microstructure and the frictional properties of the GA coatings were investigated by SEM observation for the cross-section of the GA coating after and before flat friction tests. The results showed that the mechanical and the frictional properties of the coatings are strongly dependent on their phase distributions and microstructure. Especially, in low contact pressure of 4MPa the frictional properties of the coatings were dependent on the surface phases and morphology, while in high contact pressure of 80MPa it was influenced by their mechanical properties based on the dominant phase distributions.

Evaluation of Anticancer Activity of Curcumin Analogues Bearing a Heterocyclic Nucleus

  • Ahsan, Mohamed Jawed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권4호
    • /
    • pp.1739-1744
    • /
    • 2016
  • We report herein an in vitro anticancer evaluation of a series of seven curcumin analogues (3a-g). The National Cancer Institute (NCI US) Protocol was followed and all the compounds were evaluated for their anticancer activity on nine different panels (leukemia, non small cell lung cancer, colon cancer, CNS cancer, melanoma, ovarian cancer, renal cancer, prostate cancer and breast cancer) represented by 60 NCI human cancer cell lines. All the compounds showed significant anticancer activity in one dose assay (drug concentration $10{\mu}M$) and hence were evaluated further in five dose assays (0.01, 0.1, 1, 10 and $100{\mu}M$) and three dose related parameters $GI_{50}$, TGI and $LC_{50}$ were calculated for each (3a-g) in micro molar drug concentrations (${\mu}M$). The compound 3d (NSC 757927) showed maximum mean percent growth inhibition (PGI) of 112.2%, while compound 3g (NSC 763374) showed less mean PGI of 40.1% in the one dose assay. The maximum anticancer activity was observed with the SR (leukemia) cell line with a $GI_{50}$ of $0.03{\mu}M$. The calculated average sensitivity of all cell lines of a particular subpanel toward the test agent showed that all the curcumin analogues showed maximum activity on leukemia cell lines with $GI_{50}$ values between 0.23 and $2.67{\mu}M$.

마이크로 채널 내 유도-전하 전기삼투에 의한 혼합 (Mixing in a Microchannel by using Induced-charge Electro-osmosis)

  • 전영훈;허영근;정원혁;수레수 알라파티;서용권
    • 한국가시화정보학회지
    • /
    • 제8권4호
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents an experimental study on the performance of a micro-mixer using AC electro-osmotic flow. The microchannel is made of PDMS for the side and top walls and glass patterned with ITO for the bottom wall. We first investigated the effect of the applied potential as well as the frequency on the slip velocity. We have found that the slip velocity is roughly proportional to the applied voltage in line with the Helmholtz-Smoluchowski equation and there is an optimum frequency at which the slip velocity becomes maximized. To find the optimum parameters for mixing device we tested our device for various design parameters. It turned out that the best mixing effect is obtained approximately when the electrode angle is $30^{\circ}$, electrode width $200\;{\mu}m$, and the frequency of power supply 700 Hz.

도트 패턴을 이용한 회절 격자 금형 제작 (Fabrication of Diffraction Grating Mold Using Dot Pattern)

  • 노지환;이제훈;손현기;서정;신동식;정용운
    • 한국레이저가공학회지
    • /
    • 제9권3호
    • /
    • pp.1-5
    • /
    • 2006
  • Diffraction grating is the optical device which has periodic pattern. Decorative logotypes is the one of application of diffraction grating. In this paper diffraction grating for decorative logotype is fabricated by dot pattern in stead of line pattern. A metallic mold for diffraction gratings is fabricated with a mode-locked 12 ps Nd:YVO4 laser. Laser pulses with a wavelength of 355nm are irradiated on the surface of NOK 80, a mold material, to generate dot patterns. In order to minimize the dot diameter, laser power is set just above the ablation threshold of NOK 80. Results show that the spectrum from the fabricated mold is good enough for some industrial application

  • PDF

레이저에 의해 패터닝 된 바늘과 탄성중합체와의 마찰 효과 (Investigation of friction effects between needles patterned using laser and elastomer)

  • 김재구;노승국;박종권;조성학;황경현
    • 한국레이저가공학회지
    • /
    • 제15권3호
    • /
    • pp.1-6
    • /
    • 2012
  • The friction force of patterned needle in elastomer have been investigated to verify the application for bio and plastic industry. The micro pattern on the needle surface were prepared by 266 nm, 20 ns laser and 800 nm, 220 fs laser, which were able to generate the different surface roughness. The friction force was measured by the load cell of 10 N capacity. As the results, the friction force of no patterned needle is almost constant during the needle penetrates the silicone rubber sample. However, the needle having asperities shows the variation of the friction force. The higher the surface roughness is, the smaller the friction force is until the surface roughness is very high. In our experiment conditions, the reduction of the friction force by 20 % compared to no pattern needle was achieved with straight and $50{\mu}m$ discrete line generated by 266 nm, 20 ns laser.

  • PDF

공초점 레이저 주사 현미경을 이용한 혈구 유동가시화 및 세포공핍층 측정에 관한 연구 (Flow Visualization of Blood Cell and Detection of Cell Depleted Layer Using a Confocal Laser Scanning Microscope)

  • 임수희;김위한;이호;이춘영;박철우
    • 한국가시화정보학회지
    • /
    • 제8권1호
    • /
    • pp.46-52
    • /
    • 2010
  • In the present study, we employed the confocal laser scanning microscopy (CLSM) system to visualize the blood flow field with $1{\times}1{\mu}m^2$ spatial resolution. Based on the confocal microscopic image of red blood cells (RBCs), we performed the velocity vector field measurement and evaluated characteristics of cell migration from the cell depleted layer thickness calculation. The rat and mouse's blood were supplied into a micro glass tubes in vitro. The line scanning rate of confocal microscopy was 15 kHz for a $500{\times}500$ pixels image. As a result, the red blood cell itself can be used as a tracer directly without any kind of invasive tracer particle to get the velocity vector field of blood flow by performing particle image velocimetry (PIV) technique.

치석 진단용 소형 프로브 기반 광간섭단층촬영 시스템 (A Handheld Probe Based Optical Coherence Tomography System for Diagnosis of Dental Calculus)

  • 이창호;우채경;정웅규;강현욱;오정환;김지현
    • 센서학회지
    • /
    • 제21권3호
    • /
    • pp.217-222
    • /
    • 2012
  • Optical coherence tomography(OCT) is a noninvasive optical imaging tool for biomedical applications. OCT can provide depth resolved two/three dimensional morphological images on biological samples. In this paper, we integrated an OCT system that was composed of an SLED(Superluminescent Light Emitting Diode, ${\lambda}_0$=1305 nm bandwith= 141 nm), a reference arm adopting a rapid scanning optical delay line(RSOD) to get high speed imaging, and a sample arm that used a micro electro mechanical systems(MEMS) scanning mirror. The sample arm contained a compact probe for imaging dental structures. The performance of the system was evaluated by imaging in-vivo human teeth with dental calculus, and the results indicated distinct appearance of dental calculus from enamel, gum or decayed teeth. The developed probe and system could successfully confirm the presence of dental calculus with a very high spatial resolution($6{\mu}m$).

노치가 있는 콘크리트 보에서 균열검출을 위한 음향방출기법의 적용 (Application of Acoustic Emission Technique for Detection of Crack in Notched Concrete Beams)

  • 진치섭;이래철;신동익;권성진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권4호
    • /
    • pp.215-220
    • /
    • 1999
  • Concrete micro-cracks that are grown while the structures are under construction or in service, propagate gradually or rapidly by external forces and environmental effects. As described above, almost concrete structures generally have cracks, so for the safety and durability of structures, studies to detect cracks using nondestructive tests have been treated in great deal. The purpose of this study is to evaluate characteristics of AE signals detected from notched concrete beams bending test with different loading using one of nondestructive test, Acoustic Emission (AE) method. Furthermore this study predicts the location of initial crack and measures direction of crack propagation for on-line monitoring before the crack really grows in structures by using two-dimensional AE source location based on rectangular method with three-point bending test. This will allow efficient maintenance of concrete structures through monitoring of internal cracking based on acoustic emission method.

  • PDF