• 제목/요약/키워드: Micro Defect

검색결과 220건 처리시간 0.029초

배향 성장시킨 은박막중의 결함생성 (Defect Formation in Epitaxially Grown Silver Films)

  • 이기선;김기수
    • Applied Microscopy
    • /
    • 제6권1호
    • /
    • pp.33-38
    • /
    • 1976
  • Formation of crystal defects which may occur during and after the vacuum deposition of silver films on rocksalt substrates were studied by electron microscopy. To obtain defect free films, various evaporation conditions, such as evaporation rate, substrate temperature, substrate treatments and annealing of films were examined. Stacking faults and micro-twins are dominant defects in silver films.

  • PDF

A Study on the Effects of Artifacts on Fatigue Limit of Ductile Cast Iron with Ferritic Structure

  • Kim, Jin-Hak;Kim, Min-Gun
    • Journal of Mechanical Science and Technology
    • /
    • 제14권10호
    • /
    • pp.1021-1027
    • /
    • 2000
  • In this study, fatigue tests were performed to examine the effects of micro drill hole on fatigue limit of as cast and austempered ductile cast iron (ADI) using the rotary bending fatigue tester. As results, micro drill holes ($diameter{\leq}0.4mm$) did not influence the fatigue limit of ADI, compared to annealed ductile cast iron; the critical defect size of crack initiation, in ADI was larger than as cast. If the ${\sqrt{area}}$ of micro drill hole and graphite nodule in ADI are comparable, crack initiates at the graphite nodule. When the ruggedness developes through austempering treatment process, microstructure on crack initiation at micro drill hole is tougher than that of as cast ductile cast iron.

  • PDF

미세 패턴 응용 도광판 제작에 관한 연구 (A study on fabrication of a micro patterned LGP)

  • 유영은;김태훈;김성곤;서영호;제태진;최두선
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.533-534
    • /
    • 2006
  • Micro pyramid pattern and its array are designed to enhance the brightness and its uniformity of LGP which is one of key parts in LCD. The designed micro pyramid patterns are fabricated on a Si-wafer first through MEMS process and then a Ni-stamper is electro-plated from the Si pattern master. Adopting the fabricated Ni-stamper, LGPs are injection molded at different mold temperatures and the fidelity of the pattern replication is estimated for each molding conditions and pattern locations. The replicated patterns are found to have some defect such as local short shot or micro weld line which are believed to have negative effect on the performance of the LGP.

  • PDF

초음파를 이용한 고체 추진제 추진기관의 결함 검출 기법 (Ultrasonic Inspection Technology of Defect Detection of Solid Propellant Rocket Motor)

  • 나성엽
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.239-245
    • /
    • 2006
  • 초음파를 이용한 추진기관의 비파괴검사는 X-ray 검사에 비하여 경제성이 우수하고, X-ray 검사시 취약한 dis-bond, damage 등의 결함 검출이 우수한 편이다. 그리고 전용시설의 필요없이 현장에서 실시간으로 검사가 가능하며 방사선 작업에 비하여 안전한 방법이다. 본 논문에서는 고체 추진제에 대한 초음파 특성을 분석하고, 추진제/라이너 미접착에 대한 내측과 외측 검사 방법 및 추진제 damage에 의한 미세 크랙검출에 대하여 실험 및 분석하였다. 실험 결과, 추진제에서의 초음파 감쇠는 $6\sim8db/cm$로 비교적 큰 감쇠를 보였으며 추진제/라이너 미접착에 대한 내 외측 검사에 있어서도 제한된 조건이지만 검출 가능성을 보였다. 그리고 damage에 의한 추진제 미세 크랙도 초음파의 감쇠특성을 이용하여 검출 가능함을 보였다.

  • PDF

Effect of Keratin-Based Biocomposite Hydrogels as a RhBMP-2 Carrier in Calvarial Bone Defects Mouse Model

  • Jongjin, Lee;Jinsu, Kang;Jaewon, Seol;Namsoo, Kim;Suyoung, Heo
    • 한국임상수의학회지
    • /
    • 제39권6호
    • /
    • pp.302-310
    • /
    • 2022
  • Recently, in human medicine and veterinary medicine, interest in synthetic bone graft is increasing. Among them, bone morphogenic protein (BMP) is currently being actively researched and applied to clinical trials. However, BMP has the disadvantage of being expensive and easily absorbed into surrounding tissues. Therefore, BMP requires the use of small amounts and rhBMP (recombinant human bone morphogenetic protein)-2 carriers that can be released slowly. Hydrogel has the property of swelling a large amount of water inside when it is aqueous solution, and when it is, it consists of more than 90 percent water. Using these properties, hydrogels are often used as rhBMP-2 carrier. The scaffold used in this study is a hydrogel made from which keratin is extracted using human hair and based on it. In this study, we wanted to see the effect of bone formation in the calvarial defect model by using keratin-based hydrogel made with human hair as a scaffold. The experiment was conducted by dividing 3 groups a total of 12 mice. Calvarial bone defect is set to all 4 mm diameters. Bone formation was evaluated by using gross evaluation, micro-computed tomography (micro-CT), immunohistochemistry. Groups using keratin-based hydrogel were significantly observed compared to Group 1s, and the most bone formations were found when rhBMP-2 and hydrogel were used. This represents the superiority of the functions of the rhBMP-2 carrier by a new material, keratin-based hydrogel. Through gross evaluation, micro-CT, and immunohistochemistry, we can confirm that keratin-based hydrogel is a useful rhBMP-2 carrier.

The evaluation of the correlation between histomorphometric analysis and micro-computed tomography analysis in AdBMP-2 induced bone regeneration in rat calvarial defects

  • Park, Shin-Young;Kim, Kyoung-Hwa;Koo, Ki-Tae;Lee, Kang-Woon;Lee, Yong-Moo;Chung, Chong-Pyoung;Seol, Yang-Jo
    • Journal of Periodontal and Implant Science
    • /
    • 제41권5호
    • /
    • pp.218-226
    • /
    • 2011
  • Purpose: Micro-computed tomography (micro-CT) has been widely used in the evaluation of regenerated bone tissue but the reliability of micro-CT has not yet been established. This study evaluated the correlation between histomorphometric analysis and micro-CT analysis in performing new bone formation measurement. Methods: Critical-size calvarial defects were created using a 8 mm trephine bur in a total of 24 Sprague-Dawley rats, and collagen gel mixed with autogenous rat bone marrow stromal cells (BMSCs) or autogenous rat BMSCs transduced by adenovirus containing bone morphogenic protein-2 (BMP-2) genes was loaded into the defect site. In the control group, collagen gel alone was loaded into the defect. After 2 and 4 weeks, the animals were euthanized and calvaria containing defects were harvested. Micro-CT analysis and histomorphometric analysis of each sample were accomplished and the statistical evaluation about the correlation between both analyses was performed. Results: New bone formation of the BMP-2 group was greater than that of the other groups at 2 and 4 weeks in both histomorphometric analysis and micro-CT analysis (P=0.026, P=0.034). Histomorphometric analysis of representative sections showed similar results to histomorphometric analysis with a mean value of 3 sections. Measurement of new bone formation was highly correlated between histomorphometric analysis and micro-CT analysis, especially at the low lower threshold level at 2 weeks (adjusted $r^2=0.907$, P<0.001). New bone formation of the BMP-2 group analyzed by micro-CT tended to decline sharply with an increasing lower threshold level, and it was statistically significant (P<0.001). Conclusions: Both histomorphometric analysis and micro-CT analysis were valid methods for measurement of the new bone in rat calvarial defects and the ability to detect the new bone in micro-CT analysis was highly influenced by the threshold level in the BMP-2 group at early stage.

Micro Mold 제작 및 RTP 공정에 의한 미세 패턴의 성형 (Micro Mold Fabrication and the Micro Patterning by RTP Process)

  • 김흥규;고영배;강정진;임성한;오수익
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 추계학술대회논문집
    • /
    • pp.294-297
    • /
    • 2004
  • RTP(Rapid Thermal Pressing) is to fabricate desired pattern on polymer substrate by pressing patterned mold against the substrate heated around glass transition temperature. For a successful RTP process, the whole process including heating, molding, cooling and demolding should be conducted 'rapidly' as possible. As the RTP process is effective in replicating patterns on flat large surface without causing shape distortion after cooling, it is being widely used for fabricating various micro/bio application components, especially with channel-type microstructures on surface. This investigation finally aims to develop a RTP process machine for mass-producing micro/bio application components. As a first step for that purpose, we intended to examine the technological difficulties for realizing mass production by RTP process. Therefore, in the current paper, 4 kinds of RTP machines were examined and then the RTP process was conducted experimentally for PMMA film by using one of the machines, HEX 03. The micro-patterned molds used for RTP experiment was fabricated from silicon wafer by semi-conduct process. The replicated micro patterns on PMMA films were examined using SEM and the causes of defect observed in the replicated patterns were discussed.

  • PDF

저탄소강 선재 압연의 주름성 결함 (Wrinkle Defect of Low Carbon Steel in Wire Rod Rolling)

  • 김학영;권혁철;변상민;박해두;임용택
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 제5회 압연심포지엄 신 시장 개척을 위한 압연기술
    • /
    • pp.307-316
    • /
    • 2004
  • This study examined the cause of the wrinkle defect which is frequently encountered in wire rod rolling of low carbon steel$(C0.08\~0.13wt.\%)$. Even a small defect on the surface of rolled bars can easily develop into fatal cracks during cold heading process of low carbon steel, and it is therefore necessary to minimize inherent defects on the surface of hot rolled bars. Hot rolling process of low carbon steel was analyzed to identify the cause of the wrinkle defect in conjunction with FE analysis. The integrated analysis revealed that the wrinkle defect initiated in the first stage of rolling, and it was at the billet edge where severe deformation and drastic temperature drop were present. To elucidate the micro-mechanical mechanism of the wrinkle defect, hot compression tests were carried out at various temperatures and strain rates using Gleeble-3800. The surface profile of the each other compressed specimens was compared, and rough surface lines were observed at relatively low temperatures. Those surface defects can develop into wrinkles during multi-pass rolling. To control the wrinkle defect in rolling, it is necessary to design an adequate caliber which can minimize the loss of ductility, and thereby prevent flow localization. To use the result of this study fur other steels, the quantitative measure of the wrinkle defect and flow localization parameter should be proposed.

  • PDF

Micro-titanium mesh를 이용한 안와저 골절의 외과적 처치에 대한 연구 (TREATMENT OF THE 'BLOW-OUT' FRACTURE USING MICRO-TITANIUM MESH)

  • 김성곤;전영두;윤경인
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제21권3호
    • /
    • pp.312-316
    • /
    • 1999
  • When the external force was applied to the orbit the most thin area might be displaced. These were usually orbital floor and/or medial wall of orbit. Among these cases some who showed the entrapment of the muscle between the fractured fragments needed the surgical treatment. We had operated 4 cases of the "blow-out" fracture via subciliary approach. The entrapped muscles were freed from fragments and the bony defect was restored with micro-titanium mesh. Mean follow-up periods was 15 months and there were no complication observed.

  • PDF