• Title/Summary/Keyword: Micro Chamber

Search Result 242, Processing Time 0.028 seconds

Dispersion Effect Based on Irradiation Dose and Position of QRD Microwave in Sealed Chamber (밀폐된 챔버의 QRD 마이크로파 조사용량과 위치에 따른 분산효과)

  • Kim, Jin Hyun;Han, Chung Su;Lee, Keun Woo;Lim, Kyoung Ho;Lee, Jae Hyun;Kim, Kyung Min;Ha, Yu Shin
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • This study analyzed the efficiency and uniformity by measuring the temperature change depending on the position in the chamber with the use of QRD (quadratic residue diffusor) microwave capable of inducing even sterilization by changing wavelength phase difference and enhancing the effect on low power. The results are summarized as follows: When irradiating 7 kW of QRD microwave, the highest efficiency was obtained at 35 cm height and in the center of the chamber. When irradiating 5 kW of QRD microwave, high efficiency was obtained on the sides of the chamber. When irradiating 3 kW of QRD microwave to Magnetrons 1, 2 and 3, the temperature uniformity according to the position of the bars was similar in the position of Bar 1 and 2. When irradiating 3 kW of QRD microwave to Magnetrons 3, 4 and 5, the temperature increased by approximately 10 to 20% in Bar 3. When irradiating 5, 7 and 9 kW of magnetron, the average temperature during the irradiation time increased in a similar form independently of the position of the bars. On the other hand, the efficiency of the chamber's proper internal volume was not necessarily proportional to the irradiation dose. When irradiating 3 kW of magnetron for 60 120 and 180 seconds, the temperature increased by approximately 5 to 10 at the edge of the chamber according to the irradiation position of magnetron. The temperature distribution for each position in the horizontal plane was relatively uniform, and the temperature had a tendency to slightly increase at the edge. When irradiating 5, 7 and 9 kW of magnetron, the temperature relatively evenly increased independently of the position of the bars. It was thought necessary to increase the irradiation dose by approximately 10 to 20% by considering the difference in temperature rise according to the position of magnetron.

Development of Xenon feed system for a 300 W Hall-effect Thruster (300 W급 홀 추력기를 위한 제논연료공급장치 개발)

  • Kim, Youn-Ho;Seon, Jong-Ho;Kang, Seong-Min;Wee, Jung-Hyun;Yoon, Ho-Sung;Choe, Won-Ho;Lee, Jong-Sub;Seo, Mi-Hui
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.4
    • /
    • pp.419-424
    • /
    • 2009
  • A Xenon feed system has been developed for a 300 W Hall-effect thruster intended for orbit maintenance of small satellite. The system can store about 2 kg of xenon gas at 150 bar and is capable of controlling the mass flow rate of the gas at 0.5 SCCM resolution. The performance of the system is verified with a laboratory experiment. It is confirmed that the operation of the feed system is successful at a pressure level of $1.0{\times}10^{-6}$ torr in the vacuum chamber.

The performance of Bio-aerosol Detection System (BDS) with 405 nm laser diode (405 nm 광원을 이용한 생물입자탐지기의 에어로졸 분석성능)

  • Jeong, Young-Su;Chong, Eugene;Lee, Jong-Min;Choi, Kibong
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • This paper offer the characteristics for the detection and classification of biological and non-biological aerosol particles in the air by using laser-induced-fluorescence (LIF) based Bio-aerosol Detection System (BDS). The BDS is mainly consist of an optical chamber, in-outlet nozzle system, 405 nm diode laser, an avalanche photo detector (APD) for scattering signal and photomultiplier tubes (PMT) for fluorescence signals in two different wavelength range ; F1, 510-600 nm and F2, 435-470 nm. The detection characteristics, especially ratio of fluorescence signal intensity were examined using well-known components : polystylene latex (PSL), fluorescence PSL, $2{\mu}m$ of SiO2 micro sphere, dried yeast, NADH, ovalbumin, fungicide powder and standard dust. The results indicated that the 405 nm diode laser-based LIF instrument can be a useful bio-aerosol detection system for unexpected biological threaten alter in real-time to apply for dual-use technology in military and civilian fields.

Fabrication of Methanol Sensors Using Conductive Polypyrrole Nanofibers with a Core-Shell Structure (코아-셀 구조를 가지는 전도성 폴리피롤 나노섬유를 이용한 메탄올 센서 제작)

  • Jun, Tae-Sun;Lee, Sungho;Kim, Yong Shin
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.383-387
    • /
    • 2014
  • Electrically conductive polypyrrole-polyvinylpyrrolidone (PPy-PVP) nanofiber mats with a core-shell structure have been successfully fabricated by a two-step process: the formation of FeCl3-containing PVP nanofiber mat by electrospinning, and the vapor-phase polymerization (VPP) of pyrrole monomer on the mat in a sealed chamber at room temperature. Surface morphology and chemical composition of the PPy-PVP mat were characterized by SEM, EDX and FTIR analyses. The as-prepared nonwoven mat was composed of PPy-PVP nanofibers with an average diameter of 300 nm. The sheet conductivity of the nanofiber mat was measured to be approximately 0.01 S/cm by a four-point probe. We have also investigated gas-sensing properties of PPy-PVP nanofiber mat upon exposure to methanol vapor. The PPy-PVP nanofiber sensors were observed to have excellent methanol-sensing performance. The nanofiber-based core-shell nanostructure could give an opportunity to fabricate a highly sensitive and fast response sensor due to its high surfaceto-volume ratio.

Electro-Fluid-Structural Interaction Simulation of a Valveless Micropump (시뮬레이션을 통한 무밸브 마이크로 펌프의 전기-유체-구조 상호작용에 대한 연구)

  • Li, Guang-Zhe;Goo, Nam-Seo;Han, Cheol-Heui
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.1
    • /
    • pp.7-13
    • /
    • 2008
  • In this paper, the pumping performance of a piezoelectric valveless micropump is simulated with a commercial finite element analysis software, COMSOL Multiphysics. The micropump developed in the previous work is composed of a 4-layer lightweight piezo-composite actuator (LIPCA), a polydimethylsiloxane (PDMS) pump chamber, and two diffusers. The piezoelectric domain, structural domain and fluid domain are coupled in the simulation. Water flow rates are numerically predicted for geometric parameters of the micropump. Based on this study, the micropump is optimally designed to obtain its highest pumping performance.

Properties of Ag Thin Films Deposited in Oxygen Atmosphere Using in- line Magnetron Sputter System (In-line 마그네트론 스퍼터 장치를 사용하여 산소 분위기에서 제작한 Ag 박막의 특성)

  • Ku, Dae-Young;Kim, Won-Mok;Cho, Sang-Moo;Hwang, Man-Soo;Lee, In-Kyu;Cheong, Byung-Ki;Lee, Taek-Sung;Lee, Kyeong-Seok;Cho, Sung-Hun
    • Korean Journal of Materials Research
    • /
    • v.12 no.8
    • /
    • pp.661-668
    • /
    • 2002
  • A study was made to examine the electrical, compositional, structural and morphological properties of Ag thin films deposited by DC magnetron sputtering in $O_2$ atmosphere with deposition temperature from room temperature to 15$0^{\circ}C$ using in-line sputter system. The Ag films deposited at temperature above $100^{\circ}C$ in oxygen atmosphere gave a similar specific resistivity to and even lower oxygen content than those deposited using pure Ar sputter gas The Ag films deposited with pure Ar gas was mainly composed of crystallites with [111] preferred orientation, while, for those deposited in oxygen atmosphere, more than 50% of the volume was composed of crystallites with [100] orientation. The difference in the micro structure did not cause any difference in the specific resistivity of Ag films. The results showed that the transparent conducting oxide films and the Ag films could be processed sequentially in the same deposition chamber with careful control of deposition temperature, which might result in a cost reduction for constructing the large scale in-line deposition system.

Ion beam induced surface modifications of sapphire and gold film deposition: studies on the adhesion enhancement and mechanisms (Ion Beam을 이용한 사파이어($Al_2O_3$) 표면개질 및 금(Au) 박막증착: 접합성 향상 및 접학기구에 대한 연구)

  • 박재원;이광원;이재형;최병호
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4B
    • /
    • pp.514-518
    • /
    • 1999
  • Gold (Au) is not supposed to react with sapphire(single crystalline ) under thermodynamic equillibrium, therefore, a strong adhesion between these two dissimilar materials is not expected. However, pull test showed that the gold film sputter-deposited onto annealed and pre-sputtered sapphire exhibited very strong adhesion even without post-deposition annealing. Strongly and weakly adhered samples as a result of the pull testing were selected to investigate the adhesion mechanisms with Auger electron spectroscopy. The Au/ interfaces were analyzed using a new technique that probes the interface on the film using Auger electron escape depth. It revealed that one or two monolayers of Au-Al-O compound formed at the Au/Sapphire interface when AES in the UHV chamber. It showed that metallic aluminum was detected on the surface of sapphire substrates after irradiating for 3 min. with 7keV Ar+ -ions. These results agree with TRIM calculations that yield preferential ion-beam etching. It is concluded that the formation of Au-Al-O compound, which is responsible for the strong metal-ceramic bonding, is due to ion-induced cleaning and reduction of the sapphire surface, and the kinetic energy of depositing gold atoms, molecules, and micro-particles as a driving force for the inter-facial reaction.

  • PDF

Development of Multi Sample Array System Based on Pneumatic Valve (공압식 미세밸브를 이용한 다중유체 배열장치 개발)

  • Kim, Chul Min;Park, Seo Jung;Kim, Gyu Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.1
    • /
    • pp.59-63
    • /
    • 2017
  • We present a multi-sample array device based on a pneumatic system. Solenoid valves were used to control a micro valve in a pneumatic system. The use of a compressor together with a vacuum pump ensured that one outlet could supply both compression and vacuum pressure. The multi-sample array device was fabricated using conventional photolithography and PDMS casting. The device was composed of a multiplexer, sample array, and rinsing. The multiplexer could control four sample solutions injecting into the sample array chamber. Sample solution not arrayed was removed by DI-water from the rinsing inlet. To prevent trapping of microbubbles in the channel during injection of sample solution into the device, surfactant was added in PDMS solution to serve as a hydrophilic surface treatment. As a result, the device could be used as a sample array for 64 cases, using four samples and three columns of three chambers.

Vacuum Packaging and Operating Properties of Micro-Tunneling Sensors

  • Park, H.W.;Lee, D.J.;Son, Y. B.;Park, J.H.;Oh, M. H.;Ju, B. K.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2000.04a
    • /
    • pp.110-110
    • /
    • 2000
  • Cantilever-shaped lateral field emitters were fabricated and their electrical characteristics were tested. As shown in Fig.1, poly-silicon cantilevers were fabricated by the surface micromachining and they were used to the vacuum magnetic field sensors. The tunneling devices were vacuum sealed with the tubeless packaging method, as shown in Fig.2 and Fig.3. The soda-lime glasses were used for better encapsulation, so the sputtered silicon and the glass layers on the soda-lime glasses were bonded together at 1x10$^{-6}$ Torr. The getter was activated after the vacuum sealing fur the stable emissions. The devices were tested outside of the vacuum chamber. Through vacuum packaging, the tunneling sensors can be utilized. Fig.4 shows that the sensor operates with the switching of the magnetic field. When the magnetic field was applied to the device, the anode currents were varied by the Lorentz force. The difference of anode currents can be varied with the strength of the applied magnetic field.

  • PDF

Influence of Ultra-high Injection Pressure and Nozzle Hole Diameter on Diesel Flow and Spray Characteristics under Evaporating Condition (증발 조건에서 초고압 분사와 노즐 홀 직경이 디젤 유량 및 분무 특성에 미치는 영향에 대한 연구)

  • Cho, Wonkyu;Park, Youngsoo;Bae, Choongsik;Yu, Jun;Kim, Youngho
    • Journal of ILASS-Korea
    • /
    • v.20 no.1
    • /
    • pp.43-52
    • /
    • 2015
  • Experimental study was conducted to investigate the effects of ultra-high injection pressure and nozzle hole diameter on diesel flow and spray characteristics. Electronically controlled ultra-high pressure fuel injection system was made to supply the fuel of ultra-high pressure consistently. Three injection pressures, 80, 160, and 250MPa were applied. Four type of injectors with identical eight nozzle holes were used. The four injectors have nozzle hole diameters of 115, 105, 95, and $85{\mu}m$ respectively. Injection quantity and rate were measured to investigate flow characteristics according to injection pressures and nozzle hole diameters. Mie-scattering and shadowgraph were performed to visualize liquid and vapor phases of diesel spray in a constant volume combustion chamber (CVCC). Ambient conditions of high pressure and high temperature in a diesel engine were simulated by using CVCC.