• Title/Summary/Keyword: Method of stationary phase

Search Result 183, Processing Time 0.031 seconds

A Study on the Off-Line Parameter Estimation for Sensorless 3-Phase Induction Motor using the D-Axis Model in Stationary Frame (정지좌표계 d축 모델을 이용한 위치센서 없는 3상 유도전동기의 오프라인 제정수 추정에 관한 연구)

  • Mun, Tae-Yang;In, Chi-Gak;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.1
    • /
    • pp.13-20
    • /
    • 2020
  • Accurate parameters based on equivalent circuit are required for high-performance field-oriented control in a three-phase induction motor. In a normal case, stator resistance can be accurately measured using a measuring equipment. Except for stator resistance, all machine parameters on the equivalent circuit should be estimated with particular algorithms. In the viewpoint of traditional regions, the parameters of an induction motor can be identified through the no-load and standstill test. This study proposes an identification method that uses the d-axis model of the induction motor in a stationary frame with the predefined information on stator resistance. Mutual inductance is estimated on the rotational dq coordination similar to that in the traditional no-load experiment test. The leakage inductance and rotor resistance can be estimated simply by applying different voltages and frequencies in the d-axis model of the induction motor. The proposed method is verified through simulation and experimental results.

Algorithm for Switch Open Fault Detection of Asymmetric 6-phase PMSM Based on Stationary Reference Frame dq-axis Currents (비대칭 6상 영구자석 동기 전동기의 정지 좌표계 DQ축 전류를 이용한 스위치 개방 고장 검출 기법)

  • Lee, Won-Seok;Kim, Han-Eol;Hwang, Seon-Hwan;Lee, Ki-Chang;Park, Jong-Won
    • Journal of IKEEE
    • /
    • v.26 no.2
    • /
    • pp.265-270
    • /
    • 2022
  • This paper proposes the detection algorithm for switch open fault of asymmetric 6-phase PMSM based on stationary reference frame dq-axis currents. In this paper, target motor has an asymmetric structure in which two upper three windings have an electrical phase difference of 30° and a neutral point is separated. As a result, dual 3-phase PWM inverters and the detection techniques due to open failures of switch are definitely required. In this paper, the dual dq-axis current control method is used for driving the asymmetric 6-phase PMSM and the open fault switch should be detected by using variable all pass filter and low pass filter in order to detect the current amplitude. The effectiveness and usefulness of the proposed method is verified by several experiments.

Interaction Proteome Analysis of Major Intracellular Serine Protease 1 in Bacillus subtilis

  • Park Sun-Young;Park Byoung-Chul;Lee Ah-Young;Kho Chang-Won;Cho Say-Eon;Lee Do-Hee;Lee Baek-Rak;Myung Pyung-Keun;Park Sung-Goo
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.5
    • /
    • pp.804-807
    • /
    • 2006
  • Bacterial serine proteases, especially those from Bacillus, have been extensively studied. Intracellular serine protease 1 (Isp1) is responsible for most of the proteolytic activity in B. subtilis. To identify Isp1 substrates and study its physiological functions, a mutant of Isp1, which has lost the enzymatic activity, was constructed. Through a GST affinity chromatographic method, several Bacillus proteins that specifically interacted with S246A mutant Isp1 protein were isolated and then identified by MALDI-TOF analysis. ClpC and elongation factor Tu (EF-Tu) were among those proteins specifically bound to mutant Isp1. In addition, several proteins involved in stationary phase adaptive response (such as RNA polymerase sigma factor, spoIIIE) were also identified. These findings led us to suggest that the major function of this serine protease, whose expression is greatly increased during the stationary phase, is to mediate transition of the cell into the stationary phase in a proper and timely manner.

Numerical Study on Frequency Up-conversion in USPR using MATLAB

  • Roh, Young-Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.497-502
    • /
    • 2010
  • In this paper, the O-mode ultrashort-pulse reflectometry (USPR) millimeter-wave signals that propagate into the plasma and cover a frequency bandwidth of 33-158 GHz are examined numerically using MATLAB. Two important processes are involved in the computation: the propagation of the USPR impulse signal through a waveguide and the frequency up-conversion using millimeter-wave mixers. These mixers are limited to intermediate frequency signals that are less than 500 mV; thus, it is necessary to disperse the impulse signal into a chirped waveform using the waveguide. The stationary phase method is utilized to derive a closed-form formula for a chirped waveform under the assumption that the USPR impulse is Gaussian. In the process of frequency up-conversion, the chirped waveform is mixed with the mixer LO signal, and the lower frequency components of the RF signal are removed using high pass filters.

Theoretical Studies on the Gas-phase Reaction of Methyl Formate with Anions$^\dag$

  • Lee, Ik-Choon;Chung, Dong-Soo;Lee, Bon-Su
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.3
    • /
    • pp.273-278
    • /
    • 1989
  • The gas-phase reactions of methyl formate with anions, $-NH_2,\;-OH,\;-CH_2CN$, are studied theoretically using the AM1 method. Stationary points are located by the reaction coordinate method, refined by the gradient norm minimization and characterized by the determination of Hessian matrix. Potential energy profiles and the stationary point structures are presented for all conceivable processes. Four reaction paths are found to be possible: formyl proton and methyl proton abstractions, carbonyl addition, and $S_N2$ process. For the most basic anion $-NH_2$ the proton abstraction path is favored, while in other case, $OH\;and\;-CH_2CN$, the carbonyl addition paths are favored. In all cases the $S_N2$ process is the most exothermic, but due to the relatively high activation barrier the process can be ruled out.

Chromatographic chiral resolution of several racemic drugs containing primary amino moiety on a chiral stationary phase

  • Lee, Won-Jae;Baek, Chae-Sun;Jin, Jing-Yu
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.278.3-279
    • /
    • 2003
  • A chiral stationary phase (CSP) prepared by bonding (18-crown-6)-2,3,11,12-tetracarboxylic acid (18-C-6-TA) to aminopropyl silica gel by HPLC was used in resolving several racemic drugs containing primary amino moiety. Most compounds used in this study were resolved on the CSP using 80% methanol in water (V/V) containing 10mM sulfuric acid as a mobile phase. These results on the CSP were compared to those on the similar CSP derived from 18-C-6-TA of the same chiral selector by different connecting method.

  • PDF

Beam Analysis of Underwater Conformal Array by Using Cylindrical Acoustic Holography (원통면 음향 홀로그래피를 이용한 수중음향 곡면배열센서의 빔 해석)

  • Kwon, Hyu-Sang;Park, Seong-Chol;Seo, Hee-Seon;Shin, Gu-Kyun;Joh, Ghee-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.10
    • /
    • pp.987-995
    • /
    • 2009
  • As an experimental technique to analyze the far-field characteristics of underwater cylindrical array sensors, cylindrical acoustic holography is studied. Inside an laboratory water tank, far-field directivity patterns as well as near-field source images are reconstructed from the measured hologram by hydrophone array. Approximate equation for far-field directivity estimation is derived based on stationary phase method. The simulation and experiment show well usefulness of the proposed method in application of underwater array sensors.

Beam analysis of underwater conformal array by using cylindrical acoustic holography (원통면 음향 홀로그래피를 이용한 수중음향 곡면배열센서의 빔 해석)

  • Kwon, Hyu-Sang;Park, Seong-Chol;Seo, Hee-Seon;Shin, Gu-Kyun;Joh, Ghee-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.111-116
    • /
    • 2009
  • As an experimental technique to analyze the far-field characteristics of underwater cylindrical array sensors, cylindrical acoustic holography is studied. Inside an laboratory water tank, far-field directivity patterns as well as near-field source images are reconstructed from the measured hologram by hydrophone array. Approximate equation for far-field directivity estimation is derived based on stationary phase method. The simulation and experiment show well usefulness of the proposed method in application of underwater array sensors.

  • PDF

Liquid Chromatographic Enantiomer Separation of α-Amino Acid Esters as Nitrobenzoxadiazole Derivatives Using Polysaccharide-Derived Chiral Stationary Phases

  • Islam, Md. Fokhrul;Lee, Wonjae
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.111-116
    • /
    • 2015
  • Liquid chromatographic enantiomer separation of ${\alpha}$-amino acid esters as nitrobenzoxadiazole (NBD) derivatives was performed using several chiral stationary phases (CSPs) based on polysaccharide derivatives under fluorescence detection. For enantiomer separation by normal HPLC, the non-aqueous derivatization method of ${\alpha}$-amino acid esters for NBD analytes was introduced. Among the six CSPs used in this study, the performance of Chiralpak IA was superior for enantiomer resolution of NBD derivatives of several ${\alpha}$-amino acid methyl esters. Also the convenient analytical method using polysaccharide-derived CSPs developed in this study was applied to determine the optical purity of ${\alpha}$-amino acids esters. It was investigated that the enantiomeric impurity levels of 0.02-1.73% were found after determination of enantiomeric purities of several commercially available L-amino acid methyl esters. It is expected to be quite useful for enantiomer separation of other ${\alpha}$-amino acid esters as NBD derivatives by normal HPLC.

Efficient Immobilization of Polysaccharide Derivatives as Chiral Stationary Phases via Copolymerization with Vinyl Monomers

  • Chen, Xiaoming;Okamoto, Yoshio;Yamamoto, Chiyo
    • Macromolecular Research
    • /
    • v.15 no.2
    • /
    • pp.134-141
    • /
    • 2007
  • The direct chromatographic separation of enantiomers by chiral stationary phases (CSPs) has been extensively developed over the past two decades, and has now become the most popular method for the analytical and preparative separations of enantiomers. Polysaccharide derivatives coated onto silica gel, as CSPs, playa significantly important role in the enantioseparations of a wide range of chiral compounds using high-performance liquid chromatography (HPLC). Unfortunately, the strict solvent limitation of the mobile phases is the main defect in the method developments of these types of coated CSPs. Therefore, the immobilization of polysaccharide derivatives onto silica gel, via chemical bonding, to obtain a new generation of CSPs compatible with the universal solvents used in HPLC is increasingly important. In this article, our recent studies on the immobilization of polysaccharide derivatives onto the silica gel, as CSPs, through radical copolymerization with various vinyl monomers are reported. Polysaccharide derivatives, with low vinyl content, can be efficiently fixed onto silica gel with high chiral recognition.