• 제목/요약/키워드: Method of Measurement

검색결과 15,818건 처리시간 0.044초

Further Development of Vision-Based Strain Measurement Methods to Verify Finite Element Analyses

  • Kim, Hyung jong;Lee, Daeyong
    • 소성∙가공
    • /
    • 제5권4호
    • /
    • pp.343-352
    • /
    • 1996
  • One of the preferred methods that can be used to verify the results of finite element analysis is to measure surface strains of the deformed part for purpose of direct comparison with simulation results. Instead of using the usual manual method the vision-based measurement method is capable of determining surface geometry and strain from the deformed grid pattern automatically with the help of a computer. To obtain strain distribution over an area, the coordinates of such a surface grid are determined from the multiple video images by applying the photogrammetry principle. Methods to improve the overall accuracy of the vision-based strain measurement system are explored and the possible accuracies that can be attained by such a measurement method are discussed. A major emphasis is placed on the initial grid application method its accuracy and ease of subsequent image processing. Finite element analyses of limiting dome height(LDH) test are carried out and the results of them are compared with exsperimen-tal data.

  • PDF

한지의 산성도 측정을 위한 비파괴적 방법의 적용 (The application of a nondestructive method to measure the acidity of Korean papers)

  • 이혜윤;정용재;이규식;한성희
    • 보존과학연구
    • /
    • 통권20호
    • /
    • pp.21-47
    • /
    • 1999
  • According to damage of papers by the chemical cause, papers become to acidify. Among the 3 kinds of method measuring the acidity of paper, one was nondestructive method measuring the surface of the paper by flat type electrode and the others were destructive methods measuring directly by cold water extract method and hot water extract method. In case of the cellulolytic cultural properties, the latter methods were not applied because those methods must bedissociated papers. To measure the paper acidity nondestructively, we investigated the correlation of the nondestructive method and the destructive methods. The conclusions are as follows. 1) In the relationship of the cold water extract method and the hot water extract method, It was indicated that the pH measured by the hot water extract method was high quality printing paper 0.08, rough printing paper 0.13, and Korean paper 0.29 higher than that by the cold water extract method.2) In the relationship of the cold water extract method and the surface measurement method, It showed that the pH value measured by the cold water extract method was high quality printing paper 1.86, rough printing paper 0.80,and Korean paper 0.58 higher than value that by the surface measurement.3) In the relationship of the hot water extract method and the surface measurement method, It showed that the pH value measured by the hot ABSTRACT water extract method was high quality printing paper 1.78, rough printing paper 0.66, and Korean paper 0.29 higher than that by the surface measurement. From the above-mentioned results, the pH value measured by the surface measurement was need to high about 1.78∼1.86 in high quality printing paper, 0.66-0.80 in rough printing paper, and 0.29∼0.58 in Korean paper and the surface measurement with flat type electrode was very available to measure the acidity of Korean papers actually.

  • PDF

Planar near-field antenna measurement method based on symplectic relation and reaction concept

  • Cho, Yong-Heui
    • International Journal of Contents
    • /
    • 제6권2호
    • /
    • pp.6-9
    • /
    • 2010
  • Using symplectic relation and reaction concept, we propose a planar near-field antenna measurement method. A generalized probe compensation equation is deduced to obtain the probe correction formulation. To verify our approach, a reflector antenna with $1{\times}2$ horn array is fabricated and measured in the near-field measurement facility. The near-field measurement results are compared with the physical optics (PO) simulation. The results of measurement and simulation agree very well near to the mainbeam.

대규모 건물의 기밀성능 측정기준 수립에 관한 연구 (Study on the Establishment of Large Building Airtightness Measurement Standards)

  • 이동석;지경환;조재훈
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.117-124
    • /
    • 2014
  • Airtightness standards using fan pressurization method are normally used for measuring small buildings, detached houses, and apartment units. And, it is easy to conduct airtightness measurement through this fan pressurization method. However, it can be difficult to achieve accurate measurement results for the large buildings as the height and volume of the buildings have been increased. In this paper, we studied the principle of airtightness method by fan pressurization. And, we reviewed the measurement process described in ISO 9972, EN 13829, ASTM E779, ATTMA TS 1, CAN/CGSB 149.15, and JIS A 2201. Then, we categorized the methods' items according by air flow rate (Q) and pressure difference(${\Delta}P$). As a result, we made a comparison analysis on the measurement methods appeared in each standards. And, we achieved 5 test conditions about air flow rate and pressure difference to state requirements for large buildings airtightness measurement.

Soft Tissue Measurement Method Using Radiopaque Material on Cone-beam Computed Tomography: An Ex Vivo Validation Study

  • Lee, Hae-Seok;Yun, Jeong-Ho;Lee, Dong-Won
    • 대한구강악안면임플란트학회지
    • /
    • 제22권4호
    • /
    • pp.210-218
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the validity and reproducibility of a method based on cone-beam computed tomography (CBCT) technology for the visualization and measurement of gingival soft-tissue dimensions. Material and Methods: A total of 66 selected points in soft-tissue of the ex vivo head of an adult pig were investigated in this study. For the measurement of radiographic thickness (RT), wet soft-tissue surfaces were lightly covered with barium sulfate powder using a powder spray. CBCT was taken and DICOM files were assessed for soft-tissue thickness measurement at reference points. A periodontal probe and a rubber stop were used for the measurement of trans-gingival probing thickness (TPT). After flap elevation, actual thickness of soft-tissue (actual thickness, AT) was measured. Correlation analysis and intraclass correlation coefficients analysis (ICC) were performed for AT, TPT, and RT. Results: All variables were distributed normally. Strong significant correlations of AT with RT and TPT values were found. The two ICC values between TPT vs. AT and RT vs. AT differed significantly. Conclusion: Our results indicated that correlation of RT was stronger than that of TPT with AT. We concluded that soft tissue measurement with CBCT could be a reliable method, compared to the trans-gingival probing measurement method.

Analysis, Modeling and Compensation of Dynamic Imbalance Error for a Magnetically Suspended Sensitive Gyroscope

  • Xin, Chaojun;Cai, Yuanwen;Ren, Yuan;Fan, Yahong;Xu, Guofeng;Lei, Xu
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.529-536
    • /
    • 2016
  • Magnetically suspended sensitive gyroscopes (MSSGs) provide an interesting alternative for achieving precious attitude angular measurement. To effectively reduce the measurement error caused by dynamic imbalance, this paper proposes a novel compensation method based on analysis and modeling of the error for a MSSG. Firstly, the angular velocity measurement principle of the MSSG is described. Then the analytical model of dynamic imbalance error has been established by solving the complex coefficient differential dynamic equations of the rotor. The generation mechanism and changing regularity of the dynamic imbalance error have been revealed. Next, a compensation method is designed to compensate the dynamic imbalance error and improve the measurement accuracy of the MSSG. The common issues caused by dynamic imbalance can be effectively resolved by the proposed method in gyroscopes with a levitating rotor. Comparative simulation results before and after compensation have verified the effectiveness and superiority of the proposed compensation method.

측정방식에 따른 Tabbing Cell에서의 전기적 특성 분석 (Analysis on Electrical Characteristics of Tabbing Cells According to Measurement Methods)

  • 최은지;김경수;강기환;유권종;안형근;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1304-1305
    • /
    • 2011
  • In this study, tabbing cell samples in the soft touch method are compared samples according to soldering voltage conditions. Series resistance and power loss is measured by two measurement method. As a result, probe measurement method was found optimized soldering voltage optimized according to voltage condition and clamp measurement method was not difference. The purpose of this paper is to analysis the principle of measurement method.

  • PDF

Stereoscopic micro-PTV기법의 개발 (Development of Stereoscopic Micro-PTV Method)

  • 유청환;김형범
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.109-113
    • /
    • 2007
  • Micro-PIV is a well-known method for measurement of two- dimensional, two-component velocity in the microfluidic devices. Lots of the micro fluidic devices generate three-dimensional flow and 3D measurement of velocity is helpful to understand the physics of micro flow phenomena. In this study, we developed new micro 3D measurement method by applying 2-frame PTV in stereoscopic micro system. In this study, we did the validation study of SMPTV by using the simulated flow model to verify the accuracy and the feasibility of measurement and compared with SMPIV method. The results showed that SMPTV provides better spatial resolution and measurement accuracy than SMPIV method.

  • PDF

비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석 (Analysis of Measurement Error for PM-2.5 Mass Concentration by Inter-Comparison Study)

  • 정창훈;박진희;황승만
    • 환경영향평가
    • /
    • 제19권4호
    • /
    • pp.431-441
    • /
    • 2010
  • In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5 measurement instruments can be obtained through the inter-comparison results based on filterb-ased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

새로운 접촉 및 보폭전압 측정법에 의한 접지전극 주위의 위험전압 분석기법 (Analysis Technique of Risk Voltage around Grounding Electrode by New Touch and Step Voltage Measurement Methods)

  • 길형준;김향곤
    • 조명전기설비학회논문지
    • /
    • 제26권6호
    • /
    • pp.81-86
    • /
    • 2012
  • This paper describes the analysis technique of risk voltage around grounding electrode by new touch and step voltage measurement methods. We have analyzed three techniques for risk voltage measurement, such as footprint-electrode method, test-probe method, and simulated-personnel method. We have selected test-probe method considering applicability of site. In order to reduce error related to the location of the auxiliary electrode, we propose a new approach to perform risk voltage measurement with minimum errors and short auxiliary electrode distances. Field tests were carried out at a grounding grid. It can be concluded that the proposed method will be satisfactory for risk voltage measurement.