• 제목/요약/키워드: Method of Measurement

검색결과 15,818건 처리시간 0.044초

페이저 측정 시스템의 측정기 최적배치 (Meter Optimal Placement in Measurement System with Phasor Measurement Unit)

  • 김재훈;조기선;김회철;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1195-1198
    • /
    • 1999
  • This paper presents optimal placement of minimal set of phasor measurement units(PMU's) and observability of measurement system with PMU. By using the incidence matrix symbolic method which directly assigns measurement and pseudo-measurement to incidence matrix, it is much simpler and easier to analyze observability. The optimal PMU set is found through the simulated-annealing(SA) and the direct combinational method. The cooling schedule parameter which is suitable to the property of problem to solve is specified and optimal placement is proven by presented direct combinational method. Search spaces are limited within reasonable feasible solution region to reduce a unnecessary one in the SA implementation based on global search. The proposed method presents to save CPU time and estimate state vectors based on optimal PMU set.

  • PDF

Real-Time Compensation of Errors Caused by the Flux Density Non-uniformity for a Magnetically Suspended Sensitive Gyroscope

  • Chaojun, Xin;Yuanwen, Cai;Yuan, Ren;Yahong, Fan;Yongzhi, Su
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.315-325
    • /
    • 2017
  • Magnetically suspended sensitive gyroscopes (MSSGs) provide an interesting alternative for achieving precious attitude angular measurement. To effectively reduce the measurement error caused by the non-uniformity of the air-gap flux density in a MSSG, this paper proposes a novel compensation method based on measuring and modeling of the air-gap flux density. The angular velocity measurement principle and the structure of the MSSG are described, and then the characteristic of the air-gap flux density has been analyzed in detail. Next, to compensate the flux density distribution error and improve the measurement accuracy of the MSSG, a real-time compensation method based on the online measurement with hall probes is designed. The common issues caused by the non-uniformity of the air-gap flux density can be effectively resolved by the proposed method in high-precision magnetically suspended configurations. Comparative simulation results before and after compensation have verified the effectiveness and superiority of the proposed compensation method.

신장계에 의한 소성변형비 자동측정법의 평가에 관한 연구 (A Study on the Evaluation of the Automatic Measurement Method of Plastic Strain Ratio by Two Extensometers)

  • 김인수
    • 소성∙가공
    • /
    • 제12권5호
    • /
    • pp.504-512
    • /
    • 2003
  • The plastic strain ratios(R-values) of low carbon steel sheets were determined by the automatic strain measurement method using two extensometers, the indirect photo method for the same tensile specimen during tensile test and the indirect method for the specimen after tensile test. The experimental results showed that the measured plastic strain ratios from the automatic strain measurement method using two extensometers coincided with those from the indirect photo method and the indirect method for all tensile specimens. In addition, the strain dependence of plastic strain ratios could be continuously recorded and the anisotropy of the strength coefficient, K, and strain hardening exponent, n, could be automatically calculated in three directions by computer through the use of two extensometers. The experimental results showed that the strain dependence of R-value was related to the anisotropy of strain hardening exponent in low carbon steel sheets.

영상처리를 이용한 정적·동적 변위 계측과 속도·가속도 추산방식 연구 (Measurement of Static and Dynamic Displacement by Image Processing and Study for Prediction Method of Velocity and Acceleration)

  • 허석;이호범;장일영
    • 한국소음진동공학회논문집
    • /
    • 제21권2호
    • /
    • pp.112-119
    • /
    • 2011
  • This paper is concerned with the measurement of static and dynamic displacement by image processing(IP) and study for prediction method of velocity and acceleration. To measure the displacement visually, the measurement system consists of a telephoto zoom camera, CCD(charge coupled device) image device and a computer. The specific target on the white board is used to calculate the displacement of the structure. The captured image is then converted into a pixel-based data and then analyzed numerically. The limitation of the system depends on the image capturing speed and the pixel-size of image. In this paper, we developed for the displacement measurement using the image processing method. The proposed method enables us to measure the vibration displacement, velocity and acceleration directly without any contact. The current resolution for the displacement measurement can be seen from the results.

다수의 마이크를 이용한 관내 음향 변수의 직접 측정법 (Multiple Microphone Technique for a Direct Measurement of In-duct Acoustical Parameters)

  • 장승호;이정권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1661-1666
    • /
    • 2000
  • Nowadays, the two microphone method is accepted as the standard as specified in ASTM E1050-90 for measuring in-duct acoustic properties. However, research results on using the least square method with multiple measurement points and broadband excitation have been reported for enhancing the frequency response of the two microphone method. In this paper, the effects of varying the relative measurement positions on errors in the estimation of the acoustic quantities is studied for the multiple microphone method. Both of the theoretical and experimental results show that, among every possible sensor positioning configurations, the equidistant positioning of sensors yields the smallest error within the effective measurement frequency range. In addition, it is noted that the measurement accuracy can be increased and the effective frequency range can be widened by increasing the number of equidistant sensors. Measurement examples are shown and the results support the findings.

  • PDF

박판 변형률 측정 오차의 보정에 관한 연구 (Study on the Compensation of Strain Measurement Error in Sheet Metals)

  • 차지혜;금영탁
    • 소성∙가공
    • /
    • 제13권7호
    • /
    • pp.594-599
    • /
    • 2004
  • In the sheet metal forming operations, the strain measurement of sheet panel is an essential work which provides the formability information needed in die design, process design, and product inspection. To measure efficiently complex geometry strains, the 3-dimensional automative strain measurement system, which theoretically has a high accuracy but practically has about 3~5% strain error, is often used. For eliminating the strain error resulted in measuring the strains of formed panels using an automated strain measurement system, the position error calibration method is suggested, which computes accurate strains using the grids with accurate nodal coordinates. The accurate nodal coordinates are calculated by adding the nodal coordinates measured by the measurement system and the position error found using the multiple regression method as a function of the main error parameters obtained from the analysis of strain error in a standard cube. For the verification, the strain distributions of square and dome cups obtained from the position error calibration method are compared with those provided by the finite element analysis and ASAME.

다점 피토관을 이용한 기체 유량 측정의 불확도 평가 (Uncertainty Assessment of Gas Flow Measurement Using Multi-Point Pitot Tubes)

  • 양인영;이보화
    • 한국유체기계학회 논문집
    • /
    • 제19권2호
    • /
    • pp.5-10
    • /
    • 2016
  • Gas flow measurement in a closed duct was performed using multi-point Pitot tubes. Measurement uncertainty was assessed for this measurement method. The method was applied for the measurement of air flow into a gas turbine engine in an altitude engine test facility. 46 Pitot tubes, 15 total temperature Kiel probes and 9 static pressure tabs were installed in the engine inlet duct of inner diameter of 264 mm. Five tests were done in an airflow range of 2~10 kg/s. The flow was compressible and the Reynolds numbers were between 450,000 and 2,220,000. The measurement uncertainty was the highest as 6.1% for the lowest flow rate, and lowest as 0.8% for the highest flow rate. This is because the difference between the total and static pressures, which is also related to the flow velocity, becomes almost zero for low flow rate cases. It was found that this measurement method can be used only when the flow velocity is relatively high, e.g., 50 m/s. Static pressure was the most influencing parameter on the flow rate measurement uncertainty. Temperature measurement uncertainty was not very important. Measurement of boundary layer was found to be important for this type of flow rate measurement method. But measurement of flow non-uniformity was not very important provided that the non-uniformity has random behavior in the duct.

경락노선상 임피던스 측정기(MIR-2)의 측정신뢰도 개선방안 연구 (Improvement of the repeatability and reproducibility of the meridian impedance measurement system MIR-2)

  • 인창식;이혜정;김종열;이우철
    • Korean Journal of Acupuncture
    • /
    • 제24권4호
    • /
    • pp.55-67
    • /
    • 2007
  • Objectives : The repeatability and reproducibility of MIR-2, a newly developed impedance measurement device (four electrode method) on skin are of the meridian system, is evaluated and a method to improve the reliability is discussed. Methods : Multiple gage R&R studies were conducted for the impedance measurements over bilateral KI3 acupoint in ten participants by three assessors using MIR-2 device. Gage R&R studies were repeated after controlling the acupoint locating method or one value correction by replacing one assessor's outlying value with an average of the other assessors' values to explore any feasibility of improvement of measurement reliability. Results : Controlling acupoint locating method and replacing one value with an average of other assessors' value led to improved variation metrics in a gage R&R study. Conclusions : Measurement reliability can be improved by controlling measurement procedures or by using repeated measurement method, which will facilitate development of clinically applicable measurement device with reliability.

  • PDF

측정 불확도 산정 및 표현 (Expression of Uncertainty in Measurement)

  • 최성운
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2005년도 추계학술대회
    • /
    • pp.401-404
    • /
    • 2005
  • The ISO 'Guide to the Expression of Uncertainty in Measurement (GUH) establishes a unified method for evaluating uncertainty in measurement worldwide. This paper discusses the concepts and procedures of uncertainty evaluation.

  • PDF

레이저 간섭계를 이용한 곡률반경 측정에 관한 연구 (A Study on Curvature Radius Measurement Using Laser Interferometer)

  • 이지용;김민주;이승수;전언찬
    • 한국공작기계학회논문집
    • /
    • 제13권6호
    • /
    • pp.34-40
    • /
    • 2004
  • This paper presents studies on curvature radius measurement using the laser interferometer. It is a general practice to measure to $10^{-10}$m in length with the recent improvement and innovations in measurement technology and the processor used. The measurement methods can generally be categorized as these two: the contactual method and non-contactual method; and in this study, we will find ways to lower the cost for a CMM, or a coordinate measurement machine, and try to find an alternative. Furthermore, we will discuss some of the ways to improve the non-contactual measurement methods-optical interferometer method and the optical triangulation method. We will measure an object using a laser distance measuring device and Set the Point-contact result with the ball-bearing type and line-contact result with the bearing type, to decide on which probe type will be used.