• 제목/요약/키워드: Method of Compliance

검색결과 890건 처리시간 0.028초

고혈압 환자의 치료지시 이행에 영향을 미치는 예측요인 (Predictors of Compliance in Hypertensive Patients)

  • 민은실;허명행
    • 기본간호학회지
    • /
    • 제19권4호
    • /
    • pp.474-482
    • /
    • 2012
  • Purpose: The purposes of this study were to identify knowledge, health belief and compliance in patients with hypertension and to identify the most important predictors for compliance of hypertensive patient. Method: The participants in this study were 117 patients who were receiving treatment for hypertension at E. university hospital or one of three local clinics in D-city. Data were collected using a knowledge measurement instrument, health belief scale, and an instrument on compliance. Collected data were analyzed using $X^2$ test, ANOVA, multiple linear regression with PASW statistics 18.0 program. Results: There were statistically significantly positive correlations between knowledge of hypertension and health belief, health belief and compliance. But there was no correlation between knowledge of hypertension and compliance. In the multiple regression analysis, perceived barriers, perceived severity, perceived benefits were significant predictors to explain compliance and accounted for 54.1% of the variance in compliance. Conclusion: The results of the study indicate that health belief and compliance are significantly strongly correlated. Thus it is suggested that nursing interventions to improve compliance should include nursing care plans to increase health belief, perceived severity, perceived benefit and to decrease perceived barrier.

J적분을 이용한 원자력 압력용기강의 파괴인성치의 결정 (A method of Determination of Fracture Toughness of Reactor Pressure Vessel Steel by J Integral)

  • 오세욱;임만배;김진선
    • 한국해양공학회지
    • /
    • 제9권1호
    • /
    • pp.111-119
    • /
    • 1995
  • The elastic-plastic fracture toughness($J_{IC}$) and fracture resistance (J-R curve) of SA508-3 alloy steel used for nuclear reactor pressure vessel are investigated by using CT-type specimens. Fracture toughness tests are conducted by unloading compliance method and multiple specimen method at room temperature, -2$0^{\circ}C$ and 20$0^{\circ}C$. The apparent negative crack growth phenomenon which usually arises in partial unloading compliance test is well known. The negative crack growth phenomenon in determining J sub(IC) or J-R cure from partial unloading compliance experiments may be eliminated by the offset technique. In this study, the evaluation of $J_{IC}$ multiple specimen method recommended by the JSME gives the most reliable results by using half-size CT(similar-type) specimens.

  • PDF

유지치주치료 환자에서 재내원 협조도를 수량화 시키는 새로운 방법 (New Method to Quantify Re-call Compliance during Supportive Periodontal Therapy)

  • 정수현;조승기;장희영;유형근;피성희
    • 대한치과의사협회지
    • /
    • 제57권12호
    • /
    • pp.736-746
    • /
    • 2019
  • Supportive periodontal therapy(SPT) is essential for the long-term success of periodontal treatment. A patient's compliance with SPT is one of the most important factors affecting periodontal status. There are few studies quantifying compliance with SPT. The aim of this study is to quantify patient's compliance using new method and evaluate tooth loss depending on patient's supportive periodontal treatment compliance index(SPTCI) with SPT. This study included subjects diagnosed with generalized moderate to severe chronic periodontitis, who had completed active periodontal treatment and had SPT over 5 years in Wonkwang university dental hospital. Chart review and radiography analysis were performed. To quantify compliance, SPTCI representing average of gap between recommended schedules and actual visits has been used and evaluated with tooth loss. Mean period of SPT was 8.9 years and mean SPTCI was about 120. In statical analysis, patients who have higher SPTCI with SPT are more likely to have higher rate of tooth loss. Under SPTCI of 120, there were no significant co-relation between SPTCI and tooth loss. Patients diagnosed with moderate chronic periodontitis have significant co-relation between SPTCI and tooth loss, whereas patients diagnosed with severe chronic periodontitis have no co-relation. SPTCI, new method of quantifying compliance in this study, affected to tooth loss. This study suggests that using SPTCI could be helpful for prediction of tooth loss and be used to determine the interval of visit.

  • PDF

컴플라이언스 패턴 기반 유전자 알고리즘을 이용한 구조물 위상설계 (Structural Topology Design Using Compliance Pattern Based Genetic Algorithm)

  • 박영오;민승재
    • 대한기계학회논문집A
    • /
    • 제33권8호
    • /
    • pp.786-792
    • /
    • 2009
  • Topology optimization is to find the optimal material distribution of the specified design domain minimizing the objective function while satisfying the design constraints. Since the genetic algorithm (GA) has its advantage of locating global optimum with high probability, it has been applied to the topology optimization. To guarantee the structural connectivity, the concept of compliance pattern is proposed and to improve the convergence rate, small number of population size and variable probability in genetic operators are incorporated into GA. The rank sum weight method is applied to formulate the fitness function consisting of compliance, volume, connectivity and checkerboard pattern. To substantiate the proposed method design examples in the previous works are compared with respect to the number of function evaluation and objective function value. The comparative study shows that the compliance pattern based GA results in the reduction of computational cost to obtain the reasonable structural topology.

Simulation of the Blood Pressure Estimation Using the Artery Compliance Model and Pulsation Waveform Model

  • Jeon, Ahyoung;Ro, Junghoon;Kim, Jaehyung;Baik, Seongwan;Jeon, Gyerok
    • 센서학회지
    • /
    • 제22권1호
    • /
    • pp.38-43
    • /
    • 2013
  • In this study, the artery's compliance model and the pulsation waveform model was proposed to estimate blood pressure without applying HPF (High Pass Filter) on signal measured by the oscillometric method. The method proposed in the study considered two ways of estimating blood pressure. The first method of estimating blood pressure is by comparing and analyzing changes in pulsation waveform's dicrotic notch region during each cardiac period. The second method is by comparing and analyzing morphological changes in the pulsation waveform during each cardiac period, which occur in response to the change in pressure applied on the cuff. To implement these methods, we proposed the compliance model and the pulsation waveform model of the artery based on hemodynamic theory, and then conducted various simulations. The artery model presented in this study only took artery's compliance into account. Then, a pulsation waveform model was suggested, which uses characteristic changes in the pulsation waveform to estimate blood pressure. In addition, characteristic changes were observed in arterial volume by applying artery's pulsation waveform to the compliance model. The pulsation waveform model was suggested to estimate blood pressure using characteristic changes of the pulsation waveform in the arteries. This model was composed of the sum of sine waves and a Fourier's series in combination form up to 10th harmonics components of the sinusoidal waveform. Then characteristic of arterial volume change was observed by inputting pulsation waveform into the compliance model. The characteristic changes were also observed in the pulsation waveform by mapping the arterial volume change in accordance with applied cuff's pressure change to the pulsation waveform's change according to applied pressure changes by cuff. The systolic and diastolic blood pressures were estimated by applying positional change of pulsation waveform's dicrotic notch region.

이족 보행 로봇의 관절부위 유연특성 시뮬레이션에 관한 연구 (A Study on Computer Simulation of Joint Compliance for a Biped Robot)

  • 이기주;박중경;임시형;임홍재
    • 한국소음진동공학회논문집
    • /
    • 제17권10호
    • /
    • pp.907-911
    • /
    • 2007
  • Compliance of joints must be considered when we analyze dynamics of a multi-body system. If the virtual model for CAE(computer aided engineering) analysis does not consider compliance, the result of CAE analysis can be very different from the actual experimental result. Especially in a biped walking robot, the robot may lose walking stability due to the compliance in joints of a walking robot. This paper proposed a method applying a compliance of joints in the biped walking robot to a virtual model. Also, through the 3-D displacement measurement using a laser tracker, it was demonstrated that the virtual model considering the joint compliance could effectively simulate the nonlinear motion of the real model.

만성 관절염 환자의 가족지지, 자기효능감 및 치료지시 이행과의 관계 (A Study on the Relationships between Family Support, Self-efficacy, and Compliance in Chronic Arthritis)

  • 오진환;임난영
    • 근관절건강학회지
    • /
    • 제12권1호
    • /
    • pp.28-38
    • /
    • 2005
  • Purpose: This study was to understand the level of family support, self-efficacy and compliance and to examine the relationships of the above three variables in chronic arthritis. Method: The subjects of this study were 116 patients sampled among the limited population of outpatients and inpatients at Rheumatism Center of the H university hospital in S city. The research instruments used in this study were family support, self efficacy and compliance scale. In data analysis, SPSS 8.0 program was used. Result: 1. Family support and self-efficacy level were above the medium. 2. Compliance level was medificant. Conclusion: Rheumatism patients will be able to live satisfactorily if they gium. 3. The relation among the family support, self efficacy and compliance was signot a good education about efficient training program aimed at compliance.

  • PDF

이족 보행 로봇의 관절부위 유연특성 예측에 관한 연구 (A Study on Joint Compliance for a Biped Robot)

  • 이기주;임홍재;강윤석;박중경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.559-562
    • /
    • 2005
  • When we analyze dynamics of a multi body system, a compliance of joints must be considered. If the virtual model for CAE(computer adied engineering) analysis is not considered compliance, the result of CAE analysis will be very different from the actual result. Especially in a biped walking robot, a compliance can be caused in joints of a walking robot, and the robot may lose walking stability. This paper proposes a compliance modeling method and the effectiveness of the compliance model is verified through experiments.

  • PDF

소형 비행기 연료 계통 적합성 입증을 위한 비행시험에 관한 고찰 (Flight Test Method to Show Compliance to Fuel System Airworthiness Requirements of Small Aircraf)

  • 김성겸
    • 항공우주시스템공학회지
    • /
    • 제6권3호
    • /
    • pp.34-39
    • /
    • 2012
  • In this paper, analysis of airworthiness requirements which require flight test to show compliance and flight test method as means of compliance to those requirements are provided. For unusable fuel test, sufficient discussion between certification authority and applicant is required to select test conditions. For hot weather fuel system operation test, preservation and heating of test fuel should be done carefully not to adversely affect to test result.

Load-ratio 법에 의한 SA508C-3와 알루미늄 합금의 탄소성 파괴저항 곡선평가 (Evaluation on elastic-plastic fracture resistance curve of SA508C-3 and aluminum alloy steels by load-ratio method)

  • ;윤한기;차귀준
    • 한국해양공학회지
    • /
    • 제10권2호
    • /
    • pp.98-105
    • /
    • 1996
  • A method is proposed to evaluate the elastic-plastic fracture resistance curve only with load displacement records without the crack length measurement in CT specimen. This method is based on the idea that the effect of plastic deformation and the crack growth can be measured only by using a load-displacement record. If we know the reference-load curve representing the hardening of specimen, then the crack extension can be calculated by the elastic compliance determined from the load ratio. The results of this proposed method were compared to those of the elastic-plastic fracture resistance curve for the ASTM standard unloading compliance method. The experimental results for two kinds of ductile materials showed that the proposed method well simulates the material J-R curves. This method is currently applied for CT specimens. but it can be extended to the other specimen geometries.

  • PDF