• Title/Summary/Keyword: Method R

Search Result 15,212, Processing Time 0.046 seconds

Verification of Two Least-Squares Methods for Estimating Center of Rotation Using Optical Marker Trajectory

  • Lee, Jung Keun
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.371-378
    • /
    • 2017
  • An accurate and robust estimation of center of rotation (CoR) using optical marker trajectory is crucial in human biomechanics. In this regard, the performances of the two prevailing least-squares methods, the Gamage and Lasenby (GL) method, and the Chang and Pollard (CP) method, are verified in this paper. While both methods are sphere-fitting approaches in closed form and require no tuning parameters, they have not been thoroughly verified by comparison of their estimation accuracies. Furthermore, while for both methods, results for stationary CoR locations are presented, cases for perturbed CoR locations have not been investigated for any of them. In this paper, the estimation performances of the GL method and CP method are investigated by varying the range of motion (RoM) and noise amount, for both stationary and perturbed CoR locations. The difference in the estimation performance according to the variation in the amount of noise and RoM was clearly shown for both methods. However, the CP method outperformed the GL method, as seen in results from both the simulated and the experimental data. Particularly, when the RoM is small, the GL method failed to estimate the appropriate CoR while the CP method reasonably maintained the accuracy. In addition, the CP method showed a considerably better predictability in CoR estimation for the perturbed CoR location data than the GL method. Accordingly, it may be concluded that the CP method is more suitable than the GL method for CoR estimation when RoM is limited and CoR location is perturbed.

Adaptive Finite Element Analysis of 2-D Plane Problems Using the R-P version (R-P법에 의한 이차원 평면문제의 적응 유한요소 해석)

  • Chung, Sang-Wook;Lim, Jang-Keun
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.345-350
    • /
    • 2000
  • Adaptive finite element analysis, which its solution error meets with the user defined allowable error, is recently used far improving reliability of finite element analysis results. This adaptive analysis is composed of two procedures; one is the error estimation of an analysis result and another is the reconstruction of finite elements. In the rp-method, an element size is controlled by relocating of nodal positions(r-method) and the order of an element shape function is determined by the hierarchical polynomial(p-method) corresponding to the element solution error. In order to show the effectiveness and accuracy of the suggested rp-method, various numerical examples were analyzed and these analysis results were examined by comparing with those obtained by the existed methods. As a result of this study, following conclusions are obtained. (1) rp-method is more accurate and effective than the r- and p-method. (2) The solution convergency of the rp-method is controlled by means of the iterative calculation numbers of the r- and p- method each other.

  • PDF

Procedures for Detecting Multiple Outliers in Linear Regression Using R

  • Kwon, Soon-Sun;Lee, Gwi-Hyun;Park, Sung-Hyun
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2005.11a
    • /
    • pp.13-17
    • /
    • 2005
  • In recent years, many people use R as a statistics system. R is frequently updated by many R project teams. We are interested in the method of multiple outlier detection and know that R is not supplied the method of multiple outlier detection. In this talk, we review these procedures for detecting multiple outliers and provide more efficient procedures combined with direct methods and indirect methods using R.

  • PDF

A Novel Nucleic Lateral Flow Assay for Screening phaR-Containing Bacillus spp.

  • Wint, Nay Yee;Han, Khine Kyi;Yamprayoonswat, Wariya;Ruangsuj, Pattarawan;Mangmool, Supachoke;Promptmas, Chamras;Yasawong, Montri
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.1
    • /
    • pp.123-129
    • /
    • 2021
  • Polyhydroxyalkanoate (PHA) synthase is a key enzyme for PHA production in microorganisms. The class IV PHA synthase is composed of two subunits: PhaC and PhaR. The PhaR subunit, which encodes the phaR gene, is only present in class IV PHA synthases. Therefore, the phaR gene is used as a biomarker for bacteria that contain a class IV PHA synthase, such as some Bacillus spp. The phaR gene was developed to screen phaR-containing Bacillus spp. The phaR screening method involved two steps: phaR gene amplification by PCR and phaR amplicon detection using a DNA lateral flow assay. The screening method has a high specificity for phaR-containing Bacillus spp. The lowest amount of genomic DNA of B. thuringiensis ATCC 10792 that the phaR screening method could detect was 10 pg. This novel screening method improves the specificity and sensitivity of phaR gene screening and reduces the time and cost of the screening process, which could enhance the opportunity to discover good candidate PHA producers. Nevertheless, the screening method can certainly be used as a tool to screen phaR-containing Bacillus spp. from environmental samples.

Research on R-C Distributed Circuits (R-C 분포회로에 관한 연구)

  • 박송배
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.3 no.2
    • /
    • pp.10-17
    • /
    • 1966
  • A method by which solutions of the differential equations of any other distributed circuits can be obtained is described when the solution of the differential equation of an R-C distributed amplifier is known. A graphical method of transforming any R-C ditributed circuit into an equivalent circuit which has a constant R(x)$cdot$C(x) was also obtained. The theoretical verification of this method is possible. For simplicity, any R-C distributed circuit can be transformed into an equivalent circuit which is a distributed circuit of either constant R(x) or C(x). Using this equivalent circuit and considering a lumped circuit, an approximate analysis and synthesis can be made simply.

  • PDF

Quantification of R-ratio effect on J-integral under large-amplitude cyclic loading condition (큰 진폭의 반복하중 조건에서 R-ratio에 따른 J-적분 정량화)

  • Nam, Hyun Suk;Kim, Yun Jae;Kim, Jin Weon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.2
    • /
    • pp.34-39
    • /
    • 2016
  • This paper presents a method to quantify R-ratio effect on J-integral under large-amplitude cyclic loading condition. Generally, monotonic tearing resistance curves are used to assess stability of cracked nuclear piping under seismic loading. However, it is well known that fracture toughness decrease at cyclic loading condition, according to R-ratio. For this reason, it is important to quantify the J-R curves under cyclic loading condition. To quantify the R-ratio effect, correction method which was proposed by Tranchand is considered. This method considers crack opening area in order to calculate modified J-integral. This method leads to an increase of fracture toughness. At R=-0.5 case, this method is good agreement with monotonic J-R curves. However, results show that this method has a limit to apply a large R-ratio case.

Comparison of shaping ability between various hybrid instrumentation methods with ProTaper (ProTaper를 사용한 다양한 hybrid instrumentation methods의 근관성형 효율 비교)

  • Hong, Eun-Sook;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.11-19
    • /
    • 2006
  • The purpose of this study was to compare and evaluate the shaping abilities of various hybrid instrumentation method using constant tapered file systems with $ProTaper\^{(R)}$ S1 and the difference between experts and inexperienced clinicians in use of NiTi file. Three hybrid methods used in this study were composed of $ProTaper\^{(R)}\;S1\;and\;K-Flexofile\^{(R)}\;(group S),\;ProTaper\^{(R)}\;S1\;and\;HeroShaper\^{(R)}\;(group\;H),\;and\;ProTaper\^{(R)}\;S1\;and\;ProFile\^{(R)}\;(group\;P)$respectively. The $ProTaper\^{(R)}$-alone method (group C) was introduced as a control group. After canal preparation, the lapse of time was recorded. The images of pre- and post-operative canal were scanned and superimposed. Amounts of instrumented canal widths and centering ratio were measured at apical 1, 2 and 3 mm levels and statistical analysis was performed In this study. both of the group C and S took more time to prepare canals than other groups, Inexperienced operators required more time for the entire preparation with the groups C and H than the experienced (p<0.05). And the centering ratio of group P were preferable to $ProTaper\^{(R)}$-alone method or the hybrid technique using stainless steel files. As such, within experienced operators, group H also showed better results in addition to the group P. Under these condition, the hybrid methods of each the $ProFile^{(R)}$ system and $HeroShaper^{(R)}$ with ProTaper are recommendable comparative to $ProTaper\^{(R)}$-alone method. According to the results, the hybrid instrumentation method is a more appropriate method of canal preparation than single file system for narrow or curved canals.

The Evaluation Method for Viewing Angle Image Control (VIC) Technology

  • Kwon, Jung-Bum;Park, Seung-Chul;Le, Don-Gyou;Lee, Lim-Soo;Ahn, Byung-Chul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.700-702
    • /
    • 2008
  • A new evaluation method which named 'Security Viewing Angle Factor (SVAF)' was suggested for VIC (Viewing-angle Image Control) technology to quantify a visual hiding performance of LCD. Currently, Contrast Ration (CR) is the general method to evaluate VIC technology. However, CR shows a significant difference when compared with the result of human visual system. Furthermore, a perceptional evaluation method and its conditions were established.

  • PDF

Improvement Method for Efficiency Analysis in National R&D Programs (국가R&D사업 효율성 분석의 개선 방법)

  • Kang, Ji-Hye;Baek, Dong-Hyun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.3
    • /
    • pp.82-88
    • /
    • 2014
  • The government expands its investment on R&D programs for economic growth, thus there is growing attention on the result of R&D Programs. This study proposes more improved measuring method for efficiency when the number of R&D programs is not enough to be for measuring efficiency analysis. It provides more various application method of factors on efficiency analysis. This study analyzes the influence of each input factor on efficiency by using partial efficiency concept. And it also determines input factors in similar influence throughout Spearman correlation coefficient. Finally, it suggests new method to improve discriminatory power of efficiency analysis by determining representative factors. Also, the proposed method can be practiced not only for national R&D programs, but also for other fields of research.

An R-wave Detection method in ECG Signal Using Refractory Period (ECG 신호에서 불응기를 이용한 R-파 검출 방법)

  • Kim, Jin-Sub;Kim, Jea-Soo;Kim, Jeong-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.1
    • /
    • pp.93-101
    • /
    • 2013
  • The accurate detection of R-wave is important for other feature extraction in ECG, and R-wave has a lot of medical information about heart. Numerous R-wave detection algorithms have been studied on the ECG signal shape analysis, but it was difficult to find accurate R-wave when the shape of R-wave is similar to the shape of P-wave. This paper presents an R-wave detection method based on the refractory period that is the period of depolarization and repolarization of the cell membrane after excitation. And we also use the shape of kurtosis in the refractory period. The proposed method is validated using the ECG records of the MIT-BIH arrhythmia database. Experimental results show that the proposed method significantly outperforms other method in case of 105 and 108 record that have R-wave similar to P-wave, as well as other records.