• Title/Summary/Keyword: Metering Device

Search Result 79, Processing Time 0.028 seconds

The Device Allocation Method for Energy Efficiency in Advanced Metering Infrastructures (첨단 검침 인프라에서 에너지 효율을 위한 기기 할당 방안)

  • Jung, Sungmin
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.16 no.1
    • /
    • pp.33-39
    • /
    • 2020
  • A smart grid is a next-generation power grid that can improve energy efficiency by applying information and communication technology to the general power grid. The smart grid makes it possible to exchange information about electricity production and consumption between electricity providers and consumers in real-time. Advanced metering infrastructure (AMI) is the core technology of the smart grid. The AMI provides two-way communication by installing a modem in an existing digital meter and typically include smart meters, data collection units, and meter data management systems. Because the AMI requires data collection units to control multiple smart meters, it is essential to ensure network availability under heavy network loads. If the load on the work done by the data collection unit is high, it is necessary to allocation new data collection units to ensure availability and improve energy efficiency. In this paper, we discuss the allocation scheme of data collection units for the energy efficiency of the AMI.

Development of monitoring system and quantitative confirmation device technology to prevent counterfeiting and falsification of meters (주유기 유량 변조방지를 위한 주유기 엔코더 신호 펄스 파형 모니터링 및 정량확인 시스템 개발)

  • Park, Kyu-Bag;Lee, Jeong-Woo;Lim, Dong-Wook;Kim, Ji-hun;Park, Jung-Rae;Ha, Seok-Jae
    • Design & Manufacturing
    • /
    • v.16 no.1
    • /
    • pp.55-61
    • /
    • 2022
  • As meters become digital and smart, energy data such as electricity, gas, heat, and water can be accurately and efficiently measured with a smart meter, providing consumers with data on energy used, so that real-time demand response and energy management services can be utilized. Although it is developing from a simple metering system to a smart metering industry to create a high value-added industry fused with ICT, illegal counterfeiting of electronic meters is causing problems in intelligent crimes such as manipulation and hacking of SW. The meter not only allows forgery of the meter data through arbitrary manipulation of the SW, but also leaves a fatal error in the metering performance, so that the OIML requires the validation of the SW from the authorized institution. In order to solve this problem, a quantitative confirmation device was developed in order to eradicate the act of cheating the fuel oil quantity through encoder pulse operation and program modulation, etc. In order to prevent the act of deceiving the lubricator, a device capable of checking pulse forgery was developed, manufactured, and verified. In addition, the performance of the device was verified by conducting an experiment on the meter being used in the actual field. It is judged that the developed quantitative confirmation device can be applied to other flow meters other than lubricators, and in this case, accurate measurement can be induced.

The Methods to Improve the In-Line Eductor (포소화약제 혼합장치의 개량화 방안)

  • Joo, Seung-Ho;Lim, Mann-Taek;Kim, Hye-Won;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.275-282
    • /
    • 2011
  • A core device of foam system is the in-line eductor and it is the device to mix the foam liquid into liquid solution proper to the use density and the mixture ratio must be kept regularly regardless of changing fluid condition of the front and rear end of the in-line eductor. However, if the flux of the pressurized water changes, the mixture ratio is not kept regularly, and so it becomes a cause which a performance of fire-extinguishing deteriorates in discharging foam liquid. I devise a method to improve it that the metering orifice type in-line eductor is improved into the metering venturi type in-line eductor, the fluctuation of the mixture ratio to the flux change of the pressurized water is minimized and the performance of fire-extinguishing is kept regularly. As this method is simple in its structure and can be designed at a low cost, it helps for maintenance as well. In the future, it seems to need the research for the metering nozzle type in-line eductor in the future.

Implement of a Watt-Hour Meter Monitoring System using Powerline Communication (전력선 통신을 이용한 전력량계 모니터링 시스템 구현)

  • Park, Keun-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.8
    • /
    • pp.1143-1148
    • /
    • 2013
  • This paper deals a watt-hour meter monitor system with applying a Power Line Communication (PLC) modem and a Data Concentrator Unit (DCU). PLC modem uses the power line, so there is no need to install dedicated wiring. This system makes it possible to monitor the amount of electricity of previous current month metering data, so it can easily apply a PC-management for the electric charges and maintenance with gathering the metering data.

A study on Development of a Pneumatic Granular Applicator for Paddy Field (I) - Granular Discharge Rate, Diffuser and Optimal Application Conditions - (수도작용 송풍식 입제살포기 재발에 관한 연구 (I) - 입제 배출량, 분두 및 적정살포조건 -)

  • 정창주;정선옥;장영창;최영수;최중섭
    • Journal of Biosystems Engineering
    • /
    • v.22 no.2
    • /
    • pp.127-136
    • /
    • 1997
  • This study was accomplished to develop a pneumatic granular applicator that can be attached to the conventional ride-on rice transplanter. Operating conditions of a metering device for the applicator were determined so as to obtain the required discharge rate of granules for field application. The shape and size of diffuser was selected for the applicator and the spacing between diffusers on a boom and the boom height were determined as an optimal application condition for uniform distribution. The diffuser spacing of 1m for the fertilizer and the diffuser spacing of 0.8m for the pesticide at the boom height over 0.8m were acceptable.

  • PDF

Development of Automatic Nutrient-Solution Control System Using a Low -Cost and Precise Liquid Metering Device (액제 정밀계량장치를 이용한 액제 자동조제 시스템개발)

  • 류관희;홍순호;이규철;이정훈;황호준
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1997.06c
    • /
    • pp.89-98
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution control system for small-scale growers. The nutrient-solution control system consisted of a low-cost and precise metering device and a personal computer. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-soIution. The performance of the nutrient-solution control system was evaluated through the control of EC and pH while compared with those of commercial nutrient-solution control system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. An automatic nutrient-solution control system based on a low-cost and precise metering device was developed. 2. The developed system controlled EC and pH within $\pm$0.05 mS/cm and $\pm$0.2 pH full scale error respectively at $24^{/circ}C$. 3. When using the commercial system, the controlled values of EC and pH of the 500l of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at $22^{/circ}C$. 4. The developed nutrient-solution control system showed $\pm$0.05 mS/cm of deviation from the setting EC value over the experimental cultivation period. 5. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

Precise Control of Nutrient Solution and Analysis of Ionic Contribution to EC Reading (양액의 정밀 제어 및 이온의 EC 기여도 분석)

  • Son, Jung-Eek
    • Horticultural Science & Technology
    • /
    • v.16 no.3
    • /
    • pp.352-354
    • /
    • 1998
  • A soilless culture system with the precise control of nutrient solution was developed and the time changes of ionic contribution to EC reading was analyzed. The measuring device designed was able to wash electrodes cleanly and to measure the pH and EC of nutrient solution stably in the box. The nutrient supply system using metering device was also able to control the EC and pH within ${\pm}0.05mS/cm$ and ${\pm}0.05$, respectively. Under the EC control, activity coefficients of all ions decreased with time as ionic concentrations of $SO_4$, Mg and Ca increased due to the selective nutrient absorption by plants. Time changes of ionic contribution to EC reading could be calculated using equivalent ionic conductivities and activity coefficients obtained by numerical analysis.

  • PDF

A Study on the Development of the Seeder for Soybean and Corn (콩.옥수수 육묘용 파종기 개발에 관한 연구)

  • Kim, Dong-Eok;Kim, Hyun-Hwan;Kim, Jong-Goo;Lee, Gong-In;Kim, Sung-Ki;Chang, Yu-Seob
    • Journal of Biosystems Engineering
    • /
    • v.35 no.5
    • /
    • pp.330-335
    • /
    • 2010
  • Soybean (Glycine max Merr.) and corn (Zea mays L.) transplanting has increased because soybean and corn crops cultivated by the direct seeding method were often damaged by wild birds. The purpose of this study is to develop a seeder to sow soybean (Glycine max Merr.) and corn (Zea mays L.) in a plug tray. In order to find out design factors for a metering device of the seeder, metering characteristics on metering hole size and roller speed were experimentally investigated. Soybean (cv. 'Daewon') and corn (cv. 'Mibaekchal') were used as a materials for testing the seeder in this experiment. The metering hole size of roller suitable for Daewonkong and Mibaekchal was determined. Daewonkong was suitable for hole diameter of 10 mm and hole depth of 5.5 mm, and Mibaekcal was suitable for hole diameter of 9 mm and hole depth of 5.5 mm. At a brush length of 4 mm, one grain seeding rates of Daewonkong and Mibaekchal was 99% and 93% respectively. By inducing Mibaekchal to the hole by swing, one grain seeding rate of that increased from 91.9% to 97.7%. When roller speed is 4 m per minut, seeding efficiency of prototype was 110 sheets per hour.