• 제목/요약/키워드: Meter in/out control system

검색결과 30건 처리시간 0.027초

비선형 공압시스템 특성해석 (A Study on Dynamic Behaviour of the Nonlinear Pneumatic System)

  • 김동수;김형의
    • 연구논문집
    • /
    • 통권27호
    • /
    • pp.153-166
    • /
    • 1997
  • In industry pneumatic control system has become a important means to obtain automation because of its simplicity, fast speed and low cost. However Due to of the compressibility of air and damping friction between moving parts, it is difficult to achieve high speed driving, accurate positioning and stopping without overshoot in one pneumatic control system. This paper describes the dynamic behaviors of pneumatic linear actuator. The results will be very useful in the prediction of actuated dynamics and for the manufacturers to improve the techniques in their redesign and get better performance. Also, the experimental data is very important for the dynamic simulation and theoretical analysis.

  • PDF

알칼리탈지공정 자동화관리에 의한 표면처리용 강판의 탈지능 향상 (Improvement of the Degreasing Performance of Surface Treating Steel Sheet by the Automatic Control of Alkaline Degreasing Process)

  • 박노범;박대수;박정렬;유민수
    • 한국표면공학회지
    • /
    • 제29권2호
    • /
    • pp.132-139
    • /
    • 1996
  • Experiments on the automatic control of NaOH concentration and on the spraying condition of NaOH solution in the alkaline degreasing process of a continuous hot-dip galvanizing line have been carried out in order to improve degreasing performance of a galvanizing sheet steel using laboratory degreasing and galvanizing simulators. The concentration of NaOH for the good degreasing has been determined to be 6.0% and more and this concentration has been able to be automatically well controlled within $\pm$0.1% by employing a solution electrical conductivity meter under a flow injection analysis condition rather than by employing a sodium ion selective electrode in the degreasing simulator. Frequent blocking of the spraying nozzles of the solution has been reduced considerably by the set-up and periodical operation of an automatic valve system in the nozzle system. By applying this automatic valve system and by automatic controlling the NaOH concentration and other ordinary variables in the degreasing process, the degreasing performance has been increased from the conventional 76% to the new 85%.

  • PDF

마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(II) -자동화 시스템의 종합제어기 개발- (Fundamental Studies for the Automatic Control System in the Greenhouse Using Microcomputer(II) -A Development of a Controller for an Automatic Control System-)

  • 김진현;김철수
    • Journal of Biosystems Engineering
    • /
    • 제20권1호
    • /
    • pp.73-86
    • /
    • 1995
  • The automatic control system in the greenhouse have to be developed to the direction of considering various factors the variables such as condition of the cultivation and greenhouse, the properties and types of products. Therefore, it is more important to set up variables appropriately than the problems of automatic control system itself, and the automatic control system which satisfy these problems should be simplified in the aspect of operation. In addition, even the individual automations are not perfect yet, so more studies are required for the development of comprehensive automatic system in korea. This study was carried out to automatize environment control systems for greenhouse, especially from most intensive labor requiring parts such as watering, irrigating liquefied fertilizer, spraying chemicals, mixing and ventilation system, etc. The results are summarized as follows. 1. Control type tensiometer was expected to be desirable in the automation of watering system, therefore, a new tensiometer was designed and developed through this study. 2. The chemical spraying system developed through this study was found to be excellent in the aspect of operation. 3. When pulse type water discharge meter was used in the mixing of liquefied fertilizer and chemical solution, the error of mixing were range $\pm$0.1~0.15%. 4. The water level switch of electrod type used for controlling water level was found to be affective in both control performance and operation cost. 5. The water and level control system can be omitted if each tank size are standardized in accordance with greenhouse size, therefore, the installation cost might be significantly reduced. 6. The developed general controller was excellent in hardware parts, but still remained to be improved in software parts.

  • PDF

실내 온열환경 제어를 위한 PMV 센서의 개발 및 적용성 평가연구 (Development and Evaluation of a PMV Sensor for the Control of Indoor Thermal Environment)

  • 윤동원;강효석;안병욱
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.870-878
    • /
    • 2003
  • The maintenance of thermal equilibrium between the human body and its environment is one of the primary requirements for health, wellbeing and comfort. For the effective control of indoor thermal environment, thermostat or humidistat is used. But, it is not sufficient to control the indoor thermal environment using only one or two parameters as human response for the indoor comfortable environment. So an environmental thermal index is required for the control of indoor thermal environment effectively. In this study, a PMV sensor has been developed which has integrated from various kinds of individual sensors for temperature, humidity, air velocity, radiant temperature. After applying the PMV and PPD equation, it is possible to monitor the indoor thermal environment with the sensor system, which is adopted to the circuit for optimization according to the human response with the metabolic rate and activities. The measurement was carried out to verify the performance of the integrated sensor system in comparison with existing measurement system, the PMV meter. As a result, the possibility of applying the PMV sensor to control the indoor thermal environment simultaneously was examined.

사면 녹화용 외래초종과 재래 목·초본식물의 적정 파종량 및 혼파비에 관한 연구(II) (Optimal Amount and Mixture Ratio of Seeding of the Exotic and Native Plants for Slope Revegetation(II))

  • 전기성;우보명
    • 한국환경복원기술학회지
    • /
    • 제2권2호
    • /
    • pp.43-52
    • /
    • 1999
  • This study was carried out to verify results of the nursery seedbeds. From November of 1997 to September of 1998, the artificial banking slopes in the greenhouse of the College of Agriculture and Life Sciences, Seoul National University were seeded with the mixtures of those species. Most of exotic species showed relatively poor development of root as short as 30cm. Also the green weight of root biomass of the native species was more than two times than that of the exotic species. On the other hand, it was found that the exotic species have relatively well-developed fine roots. Thus, it was concluded that the seed-mixture of the native species with long and thick roots and the exotic species with fine roots be the most effective method for topsoil erosion control on banking-slopes. The artificial rainfall system treatment(30mm/hr, 60mm/hr, 100mm/hr) on $30^{\circ}$ banking-slopes did not cause any significant change in the amount of soil loss by erosion. The root system was best developed in the plot of 1,000 seedlings per square meter and it performed well for soil erosion control. Consequently, in the case of seeding of single herbaceous species without mixing any woody seeds, the expected seedlings were 1,000 to 2,000 per square meter.

  • PDF

소음계 교정 자동화 시스템 개발 및 성능평가 (Development and Performance of Automated Calibration System of Sound Level Meters)

  • 김용태;조문재;이용봉;서재갑
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.879-886
    • /
    • 1998
  • An automated calibration system of sound level meters was developed and tested. As a standard sound source, the speaker unit(Forstex FE208) cabineted by 440$\times$390$\times$490 $\textrm{mm}^3$(LHW) volume wood box was adopted. Including this source, the driving part was found out to have a good linearity of sound pressure output vs AC voltage input. The Hybrid-Bisect/Newton-Raphson method modified by the linearity was adopted as a searching algorithm. Uisng GPIB interface, the console PC make the control, measurements, and calculations and finally make the accumulation of useful data and results automatically by the instructon in the program coded by C languate. Several trials of automatic calibration using this developed system give the reliable results.

  • PDF

공기압 구동장치의 에너지효율 평가 (Evaluation of Energy Transfer Efficiency of Pneumatic Driving Apparatus)

  • 장지성;지상원
    • 동력기계공학회지
    • /
    • 제15권6호
    • /
    • pp.95-100
    • /
    • 2011
  • In this study, an evaluation equation of energy efficiency of pneumatic driving apparatus is proposed. The evaluation equation is derived from state equation and energy equation of air in a control volume, and, the equation of motion of a moving part of a pneumatic cylinder. As a result, distribution of consumption energy and energy efficiency of pneumatic driving apparatus can be analyzed quantitatively. The effectiveness of the proposed method is proved by a pneumatic cylinder driving apparatus using a meter-out driving method.

고속 공기압 실린더 내장용 쿠션기구의 특성 비교 (Characteristic Comparison on Internal Cushion Devices at High-speed Pneumatic Cylinders)

  • 김도태;장중걸
    • 한국자동차공학회논문집
    • /
    • 제21권6호
    • /
    • pp.24-30
    • /
    • 2013
  • This paper studies the comparative analysis on two different internal cushion devices (the types of needle and relief valve) used to absorb the energy which is generated when the pneumatic cylinder moves with the load at meter-out speed control system. The effect at varying the piston velocity under same driving condition is mainly investigated. The simulation results on pressure in the cushion chamber and the dynamic behavior of the relief valve type cushion device are compared with the needle valve type. Design and performance are improved with the cushion configuration of better quality at high-speed pneumatic cylinder. Based on the relation between absorbed energy and impact energy at cushion process, cushion performance at pneumatic cylinder is evaluated.

공압 수직실린더의 쿠션특성에 관한 실험적 연구 (An Experimental Study on Cushion Characteristics of pneumatic Cylinder for Vertically-Mounted.)

  • 김동수;김형의;이상천
    • 연구논문집
    • /
    • 통권28호
    • /
    • pp.73-87
    • /
    • 1998
  • A pneumatic control system of compressed air as a working fluid has a variety of advantages such as low price, high respondence, non-explosion and good control performance and thus has many applications in the field of automobile, electronic and semiconductor industry. However, it has a difficulty in contolling a precise position due to quick response of system and compressibility of working fluid and. in particular, shock stress may occur due to an external load, resulting in fracture of a cylinder cap unless cushion device is equipped in the linear actuator. To avoid this, a cushion device should be installed for damping effect of the external load and the supply pressure as well as for decreasing shock stress and vibration caused by high speed rotation. Previous studies include dimensionless analyses and computer simulations of cushion capability and experiments of horizontally-mounted cylinder performances. A new attempt is experimentally made in this study using a vertically-mounted cylinder under an operation condition of 4, 5 and 6 (bar) as supply pressure and 40, 70 and 100 (kgf) as external load. It turns out that the cushion pressure is mainly a function of the external load rather than the supply pressure. The cushion characteristics was also revealed in the meter-in circuit.

  • PDF

효율적 품질관리를 위한 지능형 다짐 시스템 개발 (Development of Intelligent Compaction System for Efficient Quality Control)

  • 이수민;박상일;이리호;서종원
    • 대한토목학회논문집
    • /
    • 제38권5호
    • /
    • pp.751-760
    • /
    • 2018
  • 현재 다짐공사는 작업자가 정해진 다짐횟수, 두께, 속도, 진동여부 등을 자신의 경험에 의해 개별적으로 판단하고 감독자의 육안 검사에 의해 다짐공사의 품질측정이 이루어지고 있으며, 작업 후 대표성이 떨어지는 재래식 다짐강도 측정방법인 일점시험(Spot test)을 통하여 후속 단계의 작업을 진행하고 있는 실정이다. 따라서 다짐작업 결과에 대한 정량적 확인이 불가능하며, 시공부실로 인한 문제점이 제기될 가능성이 상존하고 있다. 본 연구에서는 여러 가지 시험조건에서 실제 현장규모로 다짐을 수행한 후 연속 다짐강도 측정 방법과 재래식 다짐강도 측정 방법과의 비교를 통해 연속 다짐강도 측정 방법의 사용 타당성을 입증하였다. 타당성 입증은 연속 다짐강도 측정방법인 GPS (Global Positioning System)와 가속도계로 구성된 IC (Intelligent Compaction) 롤러의 CMV (Compaction Meter Value)를 분석하는데 있으며, 입증된 결과를 토대로 일점시험을 배제한 현장 전 범위 품질확인이 가능하다. 품질 확인은 본 연구에서 개발한 다짐공사 관제프로그램에 시각화되며, 이를 통해 현장관리자는 다짐작업과 동시에 실시간 품질 모니터링이 가능하다.