• 제목/요약/키워드: Meter Accuracy

검색결과 262건 처리시간 0.027초

습식방식의 초음파 유량계 시스템 개발에 관한 연구 (A Study on the Wet Type Ultrasonic Flow-meter System Development)

  • 이응석;권오훈;노명환;이형석
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1638-1644
    • /
    • 2005
  • This paper suggests fur the study on a fluid velocity measuring system using ultrasonic transducer. In general, the time difference method to measure the distance between transducers has been known. In this paper, the practical technology for manufacturing ultrasonic flow meter system is studied using the time difference method. The ultrasonic transducer was designed and manufactured. The transmission and receiving algorithm for ultrasonic signal was studied. The ultrasonic flow measuring system was experimented in laboratory using a water reservoir for verifying the distance measuring accuracy. Finally, it was tested in flow calibration laboratory for the velocity measuring performance. The system, designed in this study, showed 0.3 mm resolution in distance measurement. For precise flow measurement, a high speed triggering algorithm is required for ultrasonic signal receiving.

스크류유량계 개발에서의 역공학 및 성능평가에 관한 연구 (A Study on the Reverse Engineering and Performance Test in the Development of Screw Flowmeter)

  • 황종대;정종윤;이상렬;정윤교
    • 한국기계가공학회지
    • /
    • 제4권2호
    • /
    • pp.24-30
    • /
    • 2005
  • This research presents a modeling and a manufacturing method of screw flow meter. This paper introduces the efficient design and manufacturing method of screw type flow meter using reverse engineering and test technology. The methods introduced this paper utilize the reverse engineering that is increasing accuracy of modeling and manufacturing of reverse model. And then it can be used in performance test with hydraulic test equipment. Hence this can be used in the basic document for development of the quite accurate flowmeter.

  • PDF

터빈유량계의 난류유동에 대한 수치해석 (Numerical Analysis of Turbulent Flow Through Turbine Flow Meter)

  • 김진범;박경암;고성호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.573-578
    • /
    • 2000
  • Flow through turbine flow meter is simulated by solving the incompressible Navier-Stockes equations. The solution method is based on the pseudocompressibility approach and uses an implicit-upwind differencing scheme together with the Gauss-Seidel line relaxation method. The equations are solved steadily in rotating reference frames and the centrifugal force and tile Coriolis force are added to the equation of motion. The standard $k-{\varepsilon}$ model is employed to evaluate turbulent viscosity. At first the stability and accuracy of the program is verified with the flow through a square duct with a $90^{\circ}$ bend and on the flat plate.

  • PDF

진동 인가에 따른 평판 유리 절단면의 파괴거동 (Fracture Behavior of the Cut Surface of a Flat Panel Glass according to Vibration Input)

  • 최성대;정선환;김기만;권현규;전재목;노영진
    • 한국기계가공학회지
    • /
    • 제4권3호
    • /
    • pp.51-56
    • /
    • 2005
  • This research presents a modeling and a manufacturing method of screw flow meter. This paper introduces the efficient design and manufacturing method of screw type flow meter using reverse engineering and test technology. The methods introduced this paper utilize the reverse engineering that is increasing accuracy of modeling and manufacturing of reverse model. And then it can be used in performance test with hydraulic test equipment. Hence this can be used in the basic document for development of the quite accurate flowmeter.

  • PDF

자동검침 고객의 부하패턴을 이용한 일일 대표 부하패턴 생성 (Typical Daily Load Profile Generation using Load Profile of Automatic Meter Reading Customer)

  • 김영일;신진호;이봉재;양일권
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1516-1521
    • /
    • 2008
  • Recently, distribution load analysis using AMR (Automatic Meter Reading) data is researched in electric utilities. Load analysis method based on AMR system generates the typical load profile using load data of AMR customers, estimates the load profile of non-AMR customers, and analyzes the peak load and load profile of the distribution circuits and sectors per every 15 minutes/hour/day/week/month. Typical load profile is generated by the algorithm calculating the average amount of power consumption of each groups having similar load patterns. Traditional customer clustering mechanism uses only contract type code as a key. This mechanism has low accuracy because many customers having same contract code have different load patterns. In this research, We propose a customer clustring mechanism using k-means algorithm with contract type code and AMR data.

역공학 기술을 이용한 스크류 유량계 개발 및 성능평가에 관한 연구 (Study on the Development and Performance Test of Screw Flowmeter using Reverse Engineering)

  • 김형일;황종대;정윤교
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.601-606
    • /
    • 2005
  • This research presents a modeling and a manufacturing method of screw flow meter. This paper introduces the efficient design and manufacturing method of screw type flow meter using reverse engineering and test technology. The methods introduced this paper utilize the reverse engineering that is increasing accuracy of modeling and manufacturing of reverse model. And then it can be used in performance test with hydraulic test equipment. Hence this can be used in the basic document for development of the quite accurate flowmeter.

  • PDF

국내 웹 사이트 패스워드 미터 분석 (An Analysis of Password Meters for Domestic Web Sites)

  • 김경훈;권태경
    • 정보보호학회논문지
    • /
    • 제26권3호
    • /
    • pp.757-767
    • /
    • 2016
  • 패스워드 인증은 가장 대표적인 사용자 인증 기법이며 그 중에서 특히 문자 기반 패스워드가 가장 많이 사용되고 있다. 그러나 사용자들이 선택하는 패스워드가 갖는 취약성으로 인하여 사용자로 하여금 강한 패스워드 생성을 유도하기 위해 많은 웹사이트에서는 패스워드 강도를 측정하는 패스워드 미터를 제공하고 있다. 하지만 여기에는 패스워드 미터결과가 일관되지 않고, 정확하지 않은 강도로 피드백하는 문제가 있다. 이에 본 논문에서는 패스워드 미터의 문제점에 대해 알아보며 패스워드 미터의 개선 방향을 제시하고자 한다.

Open-channel discharges evaluation by the application of smart sensors

  • Khatatbeh, Arwa;Kim, Young-Oh
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.138-138
    • /
    • 2022
  • Understanding a stream's or river's discharge is essential for a variety of hydrological and geomorphological applications at various sizes. However, depending on the stream environment and flow conditions, it is crucial to use the appropriate techniques and instruments. This will ensure that discharge estimations are as reliable as possible. This study presents developed smart system for continuous measurement of open channel discharge and evaluate streamflow measurement over various techniques. This includes developed smart flow meter as flow point measurements, smart water level sensor (installed on Hydraulic Structure ? Weir) and current meters. Advantages and disadvantages of each equipment are presented to ensure that the most appropriate method can be selected. we found that smart water level sensor is more prominent once used during flood event as compared to smart flow meter and current meters, while current meters seems to show better accuracy once applied for open channel.

  • PDF

천식 및 만성폐쇄성폐질환 환자에서 Mini-Wright Peak Flowmeter로 측정한 최대호기유속의 정확도 (An Evaluation of the Accuracy of Mini-Wright Peak Flowmeters in Patients with Asthma and Chronic Obstructive Pulmonary Disease)

  • 최원일;한승범;전영준
    • Tuberculosis and Respiratory Diseases
    • /
    • 제50권3호
    • /
    • pp.310-319
    • /
    • 2001
  • 연구배경 : 천식의 치료에 널리 사용되고 있는 호기유속측정기는 외래환자와 응급실에서뿐만 아니라 입원 천식환자들의 치료 및 경과 관찰에 매우 유용하다. 호기유속측정기에 대한 정확도 및 재현성에 대한 많은 연구가 있어왔으나 기류폐색을 가지는 환자를 대상으로 측정했을때의 정확도에 관한 연구는 드물다. 따라서 만성폐쇄성폐질환 또는 천식을 가지는 환자를 대상으로 잘 보정된 mass flow sensor의 최대호기유속 측정치와 mini-Wright peak flowmeter의 측정치를 비교하여 정확도를 관찰하고자 본 연구를 계획하였다. 방 법 : 천식 및 만성페쇄성폐질환으로 진단된 환자 108명을 대상으로 흡입용 기관지확장제 사용 전 후의 최대호기유속을 측정하였으며 잘 보정된 mass flow sensor로 측정한 후 mini-Wright peak flowmeter를 사용해서 최대호기유속을 측정하였다. 결 과 : 천식 및 만성폐쇄성폐질환 환자에서 mini-Wright peak flowmeter로 측정한 최대호기유속 값은 기관지 확장제 사용 유무에 관계없이 mass flow sensor의 측정치보다 평균 37-39 l/min 높게 관찰되었고 300 l/min 이하의 범위에서 오차는 25% 이상이었고 301 l/min 이싱에서는 17% 이하로 관찰되었다. 두 기기로 측정한 값의 일치도를 평가할 수 있는 편의(bias)는 전체를 대상으로 했을 때와 유속의 정도에 따라서도 모두 일치범위를 벗어나고 통계적으로도 유의하게 차이가 있었다. 결 론 : 천식 및 만성폐쇄성폐절환 환자에서 mini-Wright peak flow meter로 측정한 최대호기유속은 mass flow senor의 측정치보다 높게 관찰되었으며 300 l/mm이하의 유속에서 오차가 심했다. 두 기계로 측정한 최대호기유속 사이의 일치범위는 95% 신뢰구간에서 통계적으로 유의한 차이가 있었으므로 mass flow sensor 와 mini-Wright peak flow meter로 측정 한 결과를 상호교환적으로 사용할 수 없다고 판단된다.

  • PDF

차량의 변속기 오일레벨 측정을 위한 FPGA 기반 초음파 레벨 측정기 개발 (A FPGA-based Development of Ultrasonic Level Meter for Measuring Oil Levels of Vehicle Transmissions)

  • 강문호;박윤창
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5427-5433
    • /
    • 2012
  • 본 논문에서는 자동차 변속기 오일레벨을 정확하고 손쉽게 측정할 수 있는 초음파 오일레벨 측정기를 개발하고 실험을 통하여 유용성을 보였다. 초음파 프로브 구동 펄스 생성과 오일레벨 연산을 비롯한 모든 디지털 신호 처리가 하나의 FPGA에 의해서 이루어지도록 하여 측정기의 단순화와 고성능화를 이루었고, 모든 프로그램을 FPGA 프로젝트 IDE상에서 제작하여 측정기 개발 시간을 줄일 수 있었다. 또한, 저-레벨의 초음파 에코 신호를 처리하기 위한 송수신 스위치회로, 다단 능동 필터회로 및 포락선 검출회로 등을 설계하였고, 실험을 통하여 설계된 측정기가 약 1mm 이내의 측정 정확도를 가짐을 확인하였다.