• 제목/요약/키워드: Metallic element

검색결과 277건 처리시간 0.027초

Influence of shape and finishing on the corrosion of palladium-based dental alloys

  • Milheiro, Ana;Muris, Joris;Kleverlaan, Cornelis J.;Feilzer, Albert J.
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.56-61
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the effects of the surface treatment and shape of the dental alloy on the composition of the prosthetic work and its metallic ion release in a corrosive medium after casting. MATERIALS AND METHODS. Orion Argos (Pd-Ag) and Orion Vesta (Pd-Cu) were used to cast two crowns and two disks. One of each was polished while the other was not. Two as-received alloys were also studied making a total of 5 specimens per alloy type. The specimens were submersed for 7 days in a lactic acid/sodium chloride solution (ISO standard 10271) and evaluated for surface structure characterization using SEM/EDAX. The solutions were quantitatively analysed for the presence of metal ions using ICP-MS and the results were statistically analysed with one-way ANOVA and a Tukey post-hoc test. RESULTS. Palladium is released from all specimens studied (range $0.06-7.08{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$), with the Pd-Cu alloy releasing the highest amounts. For both types of alloys, ion release of both disk and crown pairs were statistically different from the as-received alloy except for the Pd-Ag polished crown (P>.05). For both alloy type, disk-shaped pairs and unpolished specimens released the highest amounts of Pd ions (range $0.34-7.08{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$). Interestingly, in solutions submerged with cast alloys trace amounts of unexpected elements were measured. CONCLUSION. Shape and surface treatment influence ion release from dental alloys; polishing is a determinant factor. The release rate of cast and polished Pd alloys is between $0.06-0.69{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$, which is close to or exceeding the EU Nickel Directive 94/27/EC compensated for the molecular mass of Pd ($0.4{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$). The composition of the alloy does not represent the element release, therefore we recommend manufacturers to report element release after ISO standard corrosion tests beside the original composition.

Mark III 방열 판 구조물의 파손 강도 평가에 관한 연구 (Strength Analysis for the Plate System of the Mark III Cargo Containment)

  • 정한구;양영순
    • 한국전산구조공학회논문집
    • /
    • 제27권6호
    • /
    • pp.625-633
    • /
    • 2014
  • 본 논문에서는 액화천연가스 운송을 위해 사용되는 맴브레인형 Mark III 화물창 시스템의 주요 구조물인, 방열 판 구조물의 파손 강도 평가를 수행한 내용을 다루고 있다. Mark III 방열 판 구조물을 복합적층 구조물로 고려하였으며 상용화된 범용 유한요소 프로그램인 MSC사의 PATRAN과 MARC를 사용하여 Mark III 방열 판 구조물의 유한요소 모델을 개발하였다. 특히, 액화천연가스 화물의 특성으로 인해 Mark III 방열 판 구조물이 접하는 상온에서 극저온에 이르는 광범위한 온도 분포에 따른 재료 물성치 변화를 유한요소 모델에 포함하였다. 이 유한요소 모델을 기반으로 파손 강도 평가 절차가 확립되었으며, 이 때 Mark III 방열 판 구조물의 파손 발생 여부를 판단하기 위해 Hashin, Hill, Hoffman, maximum stress, 그리고 Tsai-Wu와 같은 이방성 파손 기준들을 사용하였다. Mark III 방열 판 구조물의 전반적인 구조적 거동을 이해하였으며 이후 초기 파손 영역에서 강도 평가를 수행하여 파손이 발생되었을 때의 위치와 하중 등을 알 수 있었다.

Effect of the restorative technique on load-bearing capacity, cusp deflection, and stress distribution of endodontically-treated premolars with MOD restoration

  • da Rocha, Daniel Maranha;Tribst, Joao Paulo Mendes;Ausiello, Pietro;Dal Piva, Amanda Maria de Oliveira;Rocha, Milena Cerqueira da;Di Nicolo, Rebeca;Borges, Alexandre Luiz Souto
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.33.1-33.12
    • /
    • 2019
  • Objectives: To evaluate the influence of the restorative technique on the mechanical response of endodontically-treated upper premolars with mesio-occluso-distal (MOD) cavity. Materials and Methods: Forty-eight premolars received MOD preparation (4 groups, n = 12) with different restorative techniques: glass ionomer cement + composite resin (the GIC group), a metallic post + composite resin (the MP group), a fiberglass post + composite resin (the FGP group), or no endodontic treatment + restoration with composite resin (the CR group). Cusp strain and load-bearing capacity were evaluated. One-way analysis of variance and the Tukey test were used with ${\alpha}=5%$. Finite element analysis (FEA) was used to calculate displacement and tensile stress for the teeth and restorations. Results: MP showed the highest cusp (p = 0.027) deflection ($24.28{\pm}5.09{\mu}m/{\mu}m$), followed by FGP ($20.61{\pm}5.05{\mu}m/{\mu}m$), CR ($17.62{\pm}7.00{\mu}m/{\mu}m$), and GIC ($17.62{\pm}7.00{\mu}m/{\mu}m$). For load-bearing, CR ($38.89{\pm}3.24N$) showed the highest, followed by GIC ($37.51{\pm}6.69N$), FGP ($29.80{\pm}10.03N$), and MP ($18.41{\pm}4.15N$) (p = 0.001) value. FEA showed similar behavior in the restorations in all groups, while MP showed the highest stress concentration in the tooth and post. Conclusions: There is no mechanical advantage in using intraradicular posts for endodontically-treated premolars requiring MOD restoration. Filling the pulp chamber with GIC and restoring the tooth with only CR showed the most promising results for cusp deflection, failure load, and stress distribution.

리튬 이차전지 음극용 Cu3Si의 고온에서의 전기화학적 특성 (Electrochemical Characteristics of Cu3Si as Negative Electrode for Lithium Secondary Batteries at Elevated Temperatures)

  • 권지윤;류지헌;김준호;채오병;오승모
    • 전기화학회지
    • /
    • 제13권2호
    • /
    • pp.116-122
    • /
    • 2010
  • DC magnetron 스퍼터링을 이용해 구리(Cu) 호일 위에 실리콘(Si)을 증착한 후 $800^{\circ}C$에서 열처리하여 $Cu_3Si$를 얻고, 이의 리튬 이차전지용 음극으로서 특성을 조사하였다. $Cu_3Si$는 Si 성분을 포함하고 있으나 상온에서 리튬과 반응하지 않았다. 선형 주사 열-전류(linear sweep thermammetry, LSTA) 실험과 고온 충방전 실험을 통하여, 상온에서 비활성인 $Cu_3Si$$85^{\circ}C$ 이상에서는 활성화되어 Si 성분이 전환(conversion)반응에 의해 리튬과 반응함을 확인하였다. $Cu_3Si$에서 분리된 Si는 $120^{\circ}C$에서 Li-Si 합금 중에서 리튬의 함량이 가장 많은 $Li_{21}Si_5$ 상까지 리튬과 반응함을 유사 평형 조건(quasi-equilibrium)의 실험으로부터 알 수 있었다. 그러나 정전류 조건($100\;mA\;{g_{Si}}^{-1}$)에서는 리튬 합금반응이 $Li_{21}Si_5$까지 진행되지 못하였다. 또한 $120^{\circ}C$에서 전환반응에 의해 생성된 Li-Si 합금과 금속 상태의 Cu는 충전과정에서 다시 $Cu_3Si$로 돌아감, 즉 $Cu_3Si$와 리튬은 가역적으로 반응함을 확인하였다. $120^{\circ}C$에서 $Cu_3Si$ 전극은 비정질 실리콘 전극보다 더 우수한 사이클 특성을 보여 주었다. 이는 비활성인 구리가 실리콘의 부피변화를 완충하여 집전체에서 탈리되는 현상을 완화하고 결과적으로 전극이 퇴화하는 것을 억제하기 때문인 것으로 설명할 수 있다. 실제로 비정질 실리콘 전극은 충방전 후에 실리콘 층의 균열과 탈리가 관찰되었으나, $Cu_3Si$ 전극에서는 이러한 현상이 관찰되지 않았다.

SEM-EDX 분석법에 의한 부산 S공업단지의 PM10과 PM2.5의 화학적 조성 및 발생원 추정 (Source Apportionment Study and Chemical Composition of PM10 and PM2.5 in the Industrial Complex of Busan City, Korea)

  • 김용석;최금찬;서정민
    • 한국환경과학회지
    • /
    • 제26권11호
    • /
    • pp.1297-1306
    • /
    • 2017
  • This study identified physical characteristics and aerosol particle sources of $PM_{10}$ and $PM_{2.5}$ in the industrial complex of Busan Metropolitan City, Korea. Samples of $PM_{10}$, $PM_{2.5}$ and also soil, were collected in several areas during the year of 2012 to investigate elemental composition. A URG cyclone sampler was used for collection. The samples were collected according to each experimental condition, and the analysis method of SEM-EDX was used to determine the concentration of each metallic element. The comparative analysis indicated that their mass concentration ranged from 1% to 3%. The elements in the industrial region that were above 10% were Si, Al, Fe, and Ca. Those below 5% were Na, Mg, and S. The remaining elements (1% of total mass) consisted of elements such as Ni, Co, Br and Pb. Finally, a statistical tool was applied to the elemental results to identify each source for the industrial region. From a principal components analysis (SPSS, Ver 20.0) performed to analyze the possible sources of $PM_{10}$ in the industrial region, five main factors were determined. Factor 1 (Si, Al), which accounted for 15.8% of the total variance, was mostly affected by soil and dust from manufacturing facilities nearby, Factors 2 (Cu, Ni), 3 (Zn, Pb), and 4 (Mn, Fe), which also accounted for some of variance, were mainly related to iron, non-ferrous metals, and other industrial manufacturing sources. Also, five factors determined to access possible sources of $PM_{2.5}$, Factor 1 (Na, S), accounted for 13.5% of the total variance and was affected by sea-salt particles and fuel incineration sources, and Factors 2 (Ti, Mn), 3 (Pb, Cl), 4 (K, Al) also explained significant proportions of the variance. Theses factors mean that the $PM_{2.5}$ emission sources may be considered as sources of incineration, and metals, and non-ferrous manufacturing industries.

Si and Mg doped Hydroxyapatite Film Formation by Plasma Electrolytic Oxidation

  • Park, Seon-Yeong;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.195-195
    • /
    • 2016
  • Titanium and its alloys are widely used as implants in orthopedics, dentistry and cardiology due to their outstanding properties, such as high strength, high level of hemocompatibility and enhanced biocompatibility. Hence, recent works showed that the synthesis of new Ti-based alloys for implant application involves more biocompatible metallic alloying element, such as, Nb, Hf, Zr and Mo. In particular, Nb and Hf are one of the most effective Ti ${\beta}-stabilizer$ and reducing the elastic modulus. Plasma electrolyte oxidation (PEO) is known as excellent method in the biocompatibility of biomaterial due to quickly coating time and controlled coating condition. The anodized oxide layer and diameter modulation of Ti alloys can be obtained function of improvement of cell adhesion. Silicon (Si) and magnesium (Mg) has a beneficial effect on bone. Si in particular has been found to be essential for normal bone and cartilage growth and development. In vitro studies have shown that Mg plays very important roles in essential for normal growth and metabolism of skeletal tissue in vertebrates and can be detected as minor constituents in teeth and bone. The aim of this study is to research Si and Mg doped hydroxyapatite film formation by plasma electrolytic oxidation. Ti-29Nb-xHf (x= 0, 3, 7 and 15wt%, mass fraction) alloys were prepared Ti-29Nb-xHf alloys of containing Hf up from 0 wt% to 15 wt% were melted by using a vacuum furnace. Ti-29Nb-xHf alloys were homogenized for 2 hr at $1050^{\circ}C$. Each alloy was anodized in solution containing typically 0.15 M calcium acetate monohydrate + 0.02 M calcium glycerophosphate at room temperature. A direct current power source was used for the process of anodization. Anodized alloys was prepared using 270V~300V anodization voltage at room. A Si and Mg coating was produced by RF-magnetron sputtering system. RF power of 100W was applied to the target for 1h at room temperature. The microstructure, phase and composition of Si and Mg coated oxide surface of Ti-29Nb-xHf alloys were examined by FE-SEM, EDS, and XRD.

  • PDF

Morphology of RF-sputtered Mn-Coatings for Ti-29Nb-xHf Alloys after Micro-Pore Form by PEO

  • Park, Min-Gyu;Park, Seon-Yeong;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.197-197
    • /
    • 2016
  • Commercially pure titanium (CP Ti) and Ti-6Al-4V alloys have been widely used for biomedical applications. However, the use of the Ti-6Al-4V alloy in biomaterial is then a subject of controversy because aluminum ions and vanadium oxide have potential detrimental influence on the human body due to vanadium and aluminum. Hence, recent works showed that the synthesis of new Ti-based alloys for implant application involves more biocompatible metallic alloying element, such as, Nb, Hf, Zr and Mo. In particular, Nb and Hf are one of the most effective Ti ${\beta}-stabilizer$ and reducing the elastic modulus. Plasma electrolyte oxidation (PEO) is known as excellent method in the biocompatibility of biomaterial due to quickly coating time and controlled coating condition. The anodized oxide layer and diameter modulation of Ti alloys can be obtained function of improvement of cell adhesion. Manganese(Mn) plays very important roles in essential for normal growth and metabolism of skeletal tissue in vertebrates and can be detected as minor constituents in teeth and bone. Radio frequency(RF) magnetron sputtering in the various PVD methods has high deposition rates, high-purity films, extremely high adhesion of films, and excellent uniform layers for depositing a wide range of materials, including metals, alloys and ceramics like a hydroxyapatite. The aim of this study is to research the Mn coatings on the micro-pore formed Ti-29Nb-xHf alloys by RF-magnetron sputtering for dental applications. Ti-29Nb-xHf (x= 0, 3, 7 and 15wt%, mass fraction) alloys were prepared Ti-29Nb-xHf alloys of containing Hf up from 0 wt% to 15 wt% were melted by using a vacuum furnace. Ti-29Nb-xHf alloys were homogenized for 2 hr at $1050^{\circ}C$. Each alloy was anodized in solution containing typically 0.15 M calcium acetate monohydrate + 0.02 M calcium glycerophosphate at room temperature. A direct current power source was used for the process of anodization. Anodized alloys was prepared using 270V~300V anodization voltage at room. Mn coatings was produced by RF-magnetron sputtering system. RF power of 100W was applied to the target for 1h at room temperature. The microstructure, phase and composition of Mn coated oxide surface of Ti-29Nb-xHf alloys were examined by FE-SEM, EDS, and XRD.

  • PDF

폴리페닐카보실란을 이용한 SiOC가 코팅된 스테인리스스틸 제조 및 이의 내부식성 특징 (SiOC Coating on Stainless Steel Using Polyphenylcarbosilane, and Its Anti-corrosion Properties)

  • 김종일;이윤주;김수룡;김영희;김정일;우창현;최두진
    • 한국재료학회지
    • /
    • 제21권1호
    • /
    • pp.8-14
    • /
    • 2011
  • To improve the chemical stability of metal, the ceramic coatings on metallic materials have attracted interest from many researchers due to the chemical inertness of ceramic materials. To endure strong acids, SiOC coating on metal substrate was carried out by dip coating method using 20wt% polyphenylcarbosilane solution; SiC powder was added to the solution at 10wt% and 15wt% to improve the mechanical properties and to prevent cracks of the film. Thermal oxidation as a curing step was carried out at $200^{\circ}C$ for crosslinking of the polyphenylcarbosilane, and the coating samples were pyrolysized at $800^{\circ}C$ under argon to convert the polyphenylcarbosilane to SiOC film. The thicknesses of the SiOC coating films were $2.36{\mu}m$ and $3.16{\mu}m$. The quantities of each element were measured as $SiO_{1.07}C_{6.33}$ by EPMA, and it can be confirmed that the SiOC film from polyphenylcarbosilane was formed in a manner that was carbon rich. The hardness of the SiOC film was found to be 3.2Gpa through nanoindentor measurement. No defect including cracks appeared in the SiOC film. The weight loss of the SiOC coated stainless steel was within 2% after soaking in 10% HCl solution at $80^{\circ}C$ for one week. From these results, SiOC coating shows good potential for application to protect against severe chemical corrosion of stainless steel.

섬유금속적층판의 모드 I 접합 거동 예측을 위한 Levenberg-Marquardt 기법 기반의 역해석 기법에 관한 수치적 연구 (Numerical Study on Inverse Analysis Based on Levenberg-Marquardt Method to Predict Mode-I Adhesive Behavior of Fiber Metal Laminate)

  • 박으뜸;이영헌;김정;강범수;송우진
    • Composites Research
    • /
    • 제31권5호
    • /
    • pp.177-185
    • /
    • 2018
  • 섬유금속적층판은 금속과 섬유 강화 복합소재를 함께 적층한 하이브리드 재료 중 하나다. 섬유금속적층판은 계면의 접착층이 파괴되는 층간분리 현상이 발생할 수 있기 때문에 계면의 접착층에 대한 한계응력과 에너지 해방률을 실험적으로 도출해야만 한다. 하지만, 온도에 따른 에너지 해방률을 실험적으로 도출하는 과정에서 측정 장비의 사용 온도에 대한 제약을 받는다. 따라서, 본 연구에서는 Levenberg-Marquardt 기법을 기반한 역해석 기법을 사용하여 접착층에 대한 모드 I 한계응력과 에너지 해방률에 대한 예측 가능성을 확인하는 것이 목표다. 먼저, 한계응력은 접착층의 인장강도와 같다고 가정하였으며, 에너지 해방률은 DCB 시험(double cantilever beam test)을 수행하여 정의하였다. 또한, 유한요소법 기반 모델을 적용하여 한계응력과 에너지 해방률을 수치해석적으로 예측할 수 있는 지 확인하였다. 그 후, Levenberg-Marquardt 기법을 유한요소법 기반 모델에 적용하여 모드 I 한계응력과 에너지 해방률을 수치해석적으로 예측하였다. 아울러, 본 연구에서 사용한 역해석 기법의 수렴성을 확보하기 위하여 두 가지 경우의 초기 매개변수에 대한 역해석을 추가적으로 수행하였다. 결과적으로, 본 연구에서 사용한 역해석 기법은 모드 I 한계응력과 에너지 해방률을 효과적으로 예측할 수 있음을 보였다.

Aluminum toxicity-induced alterations of root proteome in wheat seedlings

  • Oh, Myeong Won;Roy, Swapan Kumar;Cho, Kun;Cho, Seong-Woo;Park, Chul-Soo;Chung, Keun-Yook;Choi, Jong-Soon;Woo, Sun-Hee
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.127-127
    • /
    • 2017
  • Aluminum is the most abundant metallic element in the Earth's crust and considered as the most limiting factor for plant productivity in acidic soils. The inhibition of root growth is recognized as the primary effect of Al toxicity. Seeds of wheat cv. Keumkang (Korean cultivar) were germinated on petridish for 5 days and then transferred hydroponic apparatus which was treated with $0{\mu}M$ $AlCl_3$ (control), $100{\mu}M$ $AlCl_3$ and $150{\mu}M$ $AlCl_3$ for 5 days. The length of roots, shoots and fresh weight of wheat seedlings were decreased under aluminum stress. The concentrations of $K^+$, $Mg^{2+}$ and $Ac^{2+}$ were decreased whereas $Al^{3+}$ and $P_2O_5{^-}$ concentration was increased under aluminum stress. Using confocal microscopy, the fluorescence intensity of aluminum was increased with morin staining. In this study, a proteome analysis was performed to identify proteins, which is responsible to aluminum stress in wheat roots. In 10-day-old seedlings, proteins were extracted from roots and separated by 2-DE, stained by CBB. Using image analysis, a total of 47 differentially expressed protein spots were selected, whereas 19 protein spots were significantly up-regulated such as s-adenosylmethionine, oxalate oxidase, malate dehydrogenase, cysteine synthase, ascorbate peroxidase and 28 protein spots were significantly down-regulated such as heat shock protein 70, o-methytransferase 4, enolase, amylogenin by aluminum stress following protein spots analyzed by LTQ-FTICR mass spectrometry. The results provide the global picture of Al toxicity-induced alterations of protein profiles in wheat roots, and identify the Al toxicity-responsive proteins related to various biological processes that may provide some novel clues about plant Al tolerance.

  • PDF