Evaluation of Effect of Decrease in Metallic Artifacts using the Synthetic MR Technique (Synthetic MR 기법을 이용한 금속 인공물 감소 효과 평가)

  • Soon-Yong, Kwon;Nam-Yong, Ahn;Jeong-Eun, Oh;Seong-Ho, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.835-842
    • /
    • 2022
  • This study is aimed to evaluate the effects of a synthetic MR technique in reducing metal artifacts. In the experiment, the in-plane and through-plane images were acquired by applying a synthetic MR technique and a high-speed spin echo technique to a phantom manufactured with screw for spinal surgery. The area of the metal artifact was compared. The metal artifacts were measured by dividing the signal-loss and the signal pile-up areas, and the area of the final artifact was calculated through the sum of the two. As a result, the metal artifacts were relatively reduced when the synthetic MR techniques were applied to both in-plane and through-plane. Comparing by sequence, the in-plane T1 images decreased by 23.45%, T2 images by 20.85%, PD images by 19.67%, and FLAIR images by 22.12%. Also, in the case of the through-plane, the T1 image decreased by 62.95%, the T2 image decreased by 73.93%, the PD image decreased by 74.68%, and the FLAIR image decreased by 66.43%. The cause of this result is that when the synthetic MR technique is applied, the distortion is due to the signal pile-up and does not occur and the size of the entire metal artifact is reduced. Therefore, synthetic MR technique can very effectively reduce metal artifacts, which can help to increase the diagnostic value of images.

A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor (견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구)

  • Park, Eui-Cheol;Bae, Seok-Hwan;Ryu, Yeun-Chul;Park, Young-Joon;Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.513-519
    • /
    • 2021
  • Metallic suture anchors are very useful and common fixation devices that are inserted into the target bone to sustain the tendon of a patient with musculus supraspinatus tendon ruptures. On the other hand, the presence of a metallic material prosthesis, such as a metal suture anchor, causes severe MR imaging artifacts, including field distortion, signal loss, and failure of fat suppression. The difference in magnetic susceptibility between metal and other organic materials causes magnetic field distortion surrounding the prosthesis. The resulting magnetic field inhomogeneity makes the images with a lower signal-to-noise ratio and distortion. For a patient with a suture anchor implanted, MR imaging is the golden standard for determining the postoperative prognosis, and a fat-saturation sequence is one of the imaging methods most affected by metal-induced artifacts. In this study, three fat-saturation sequences were compared. Artifact quantification and contrast comparison between the supraspinatus tendon and the surrounding muscle were presented. The images obtained using the STIR pulse sequence showed fewer susceptibility artifacts and better visibility in the supraspinatus tendon and the tissue area. Therefore, the STIR sequence is the most appropriate fat-saturation imaging method for patients with a metallic prosthesis.

Design of Zr-7Si-xSn Alloys for Biomedical Implant Materials (생체의료용 임플란트 소재를 위한 Zr-7Si-xSn 합금설계)

  • Kim, Minsuk;Kim, Chungseok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.1
    • /
    • pp.8-19
    • /
    • 2022
  • The metallic implant materials are widely used in biomedical industries due to their specific mechanical strenth, corrosion registance, and superior biocompatability. These metallic materials, however, suffer from the stress-shielding effect and the generation of artifacts in the magnetic resonance imaging exam. In the present study, we develope a Zr-based alloys for the biomedical implant materials with low elastic modulus and low magnetic susceptibility. The Zr-7Si-xSn alloys were fabricated by an arc melting process. The elastic modulus was 24~31 GPa of the zirconium-based alloy. The average magnetic susceptibility value of the Zr-7Si-xSn alloy was 1.25 × 10-8cm3g-1. The average Icorr value of the Zr-7Si-xSn alloy was 0.2 ㎂/cm2. The Sn added zirconium alloy, Zr-7Si-xSn, is very interested and attractive as a biomaterial that reduces the stress-shielding effect caused by the difference of elastic modulus between human bone and metallic implant.

Evaluation of O-MAR XD Technique for Reduction of Magnetic Susceptibility Artifact of Knee Implant (인공 무릎관절에서 자화율 인공물의 감소를 위한 O-MAR XD 기법의 평가)

  • Lee, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.413-419
    • /
    • 2018
  • Magnetic Resonance Imaging for patients with metallic implant has poor image quality, and signal loss and artifacts including distortion can occur. The purpose of this study is to carry out a comparative evaluation on high receive bandwidth(hiBW), O-MAR, O-MAR XD to reduce artifacts in knee implant. To take MRI, 3.0T scanner and dual-source radiofrequency transmission were used. O-MAR XD technique's strong option showed a significant difference (p<0.001) with O-MAR XD technique's weak option, O-MAR and hiBW excluding the medium option. O-MAR XD's medium option had a significant difference (p<0.01) with O-MAR XD's weak, O-MAR and hiBW. O-MAR XD technique's weak option had a significant difference (p<0.01) with O-MAR XD's strong and medium options, O-MAR and hiBW. O-MAR technique had a significant difference (p<0.001) with strong, medium, weak options of O-MAR XD technique except for hiBW. HiBW had a significant difference (p<0.001) with strong, medium and weak options of O-MAR XD technique except for O-MAR. The results showed that O-MAR XD technique was more useful for MRI scan for patients with knee replacement surgery than traditional techniques such as hiBW or O-MAR, and susceptibility artifacts decreased more when O-MAR XD technique's strong or medium option was applied. Based on the results above, it is considered that it will be possible to acquire images whose susceptibility artifacts were highly decreased by using O-MAR XD technique's strong or medium option when conducting MRI for artificial knee joint and it will be helpful for checking and monitoring patients with knee joint replacement.

Influence of CBCT parameters on image quality and the diagnosis of vertical root fractures in teeth with metallic posts: an ex vivo study

  • Larissa Pereira Lagos de Melo;Polyane Mazucatto Queiroz;Larissa Moreira-Souza;Mariana Rocha Nadaes;Gustavo Machado Santaella;Matheus Lima Oliveira;Deborah Queiroz Freitas
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.2
    • /
    • pp.16.1-16.11
    • /
    • 2023
  • Objectives: The aim of this study was to evaluate the influence of peak kilovoltage (kVp) and a metal artifact reduction (MAR) tool on image quality and the diagnosis of vertical root fracture (VRF) in cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human teeth filled with an intracanal metal post were divided into 2 groups: control (n = 10) and VRF (n = 10). Each tooth was placed into the socket of a dry mandible, and CBCT scans were acquired using a Picasso Trio varying the kVp (70, 80, 90, or 99), and the use of MAR (with or without). The examinations were assessed by 5 examiners for the diagnosis of VRF using a 5-point scale. A subjective evaluation of the expression of artifacts was done by comparing random axial images of the studied protocols. The results of the diagnoses were analyzed using 2-way analysis of variance and the Tukey post hoc test, the subjective evaluations were compared using the Friedman test, and intra-examiner reproducibility was evaluated using the weighted kappa test (α = 5%). Results: The kVp and MAR did not influence the diagnosis of VRF (p > 0.05). According to the subjective classification, the 99 kVp protocol with MAR demonstrated the least expression of artifacts, while the 70 kVp protocol without MAR led to the most artifacts. Conclusions: Protocols with higher kVp combined with MAR improved the image quality of CBCT examinations. However, those factors did not lead to an improvement in the diagnosis of VRF.

Influence of CBCT metal artifact reduction on vertical radicular fracture detection

  • Oliveira, Mariana Rodrigues;Sousa, Thiago Oliveira;Caetano, Aline Ferreira;de Paiva, Rogerio Ribeiro;Valladares-Neto, Jose;Yamamoto-Silva, Fernanda Paula;Silva, Maria Alves Garcia
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.55-62
    • /
    • 2021
  • Purpose: This study evaluated the influence of a metal artifact reduction (MAR) tool in a cone-beam computed tomography (CBCT) device on the diagnosis of vertical root fractures (VRFs) in teeth with different root filling materials. Materials and Methods: Forty-five extracted human premolars were classified into three subgroups; 1) no filling; 2) gutta-percha; and 3) metallic post. CBCT images were acquired using an Orthopantomograph 300 unit with and without a MAR tool. Subsequently, the same teeth were fractured, and new CBCT scans were obtained with and without MAR. Two oral radiologists evaluated the images regarding the presence or absence of VRF. Receiver operating characteristic (ROC) curves and diagnostic tests were performed. Results: The overall area under the curve values were 0.695 for CBCT with MAR and 0.789 for CBCT without MAR. The MAR tool negatively influenced the overall diagnosis of VRFs in all tested subgroups, with lower accuracy (0.45-0.72), sensitivity (0.6-0.67), and specificity (0.23-0.8) than were found for the images without MAR. In the latter group, the accuracy, sensitivity, and specificity values were 0.68-0.77, 0.67-083, and 0.53-087, respectively. However, no significant difference was found between images with and without MAR for the no filling and gutta-percha subgroups (P>0.05). In the metallic post subgroup, CBCT showed a significant difference according to MAR use (P<0.05). Conclusion: The OP 300 MAR tool negatively influenced the detection of VRFs in teeth with no root canal filling, gutta-percha, or metallic posts. Teeth with metallic posts suffered the most from the negative impact of MAR.

Lifetime Prediction of Acrylic Resin for Metal Artifacts Reinforcement (금속유물 강화용 아크릴수지 수명예측)

  • Gwak, Hongin;Kim, Jinkuk
    • Conservation Science in Museum
    • /
    • v.10
    • /
    • pp.75-88
    • /
    • 2009
  • The purpose of this study is to determine the lifetime of acrylic resin ParaloidTM B-72(EMA copolymer), which is widely used as a coating for metallic artifacts to prevent corrosion. Lifetime factor with temperature, selected chromaticity as the test parameter for lifetime prediction. The found result is that the temperature is the most crucial factor influencing the prediction of the lifetime of the EMA copolymer coated iron surface against corrosion. The simulation results, based on Arrhenius Equation, showed that the lifetime prediction of the EMA coated iron surface was 24.5 years at 16℃, 17.1 years at 20℃, and 12.0 years at 24℃, respectively.

Dosimetric Impact of Ti Mesh on Proton Beam Therapy

  • Cho, Shinhaeng;Goh, Youngmoon;Kim, Chankyu;Kim, Haksoo;Jeong, Jong Hwi;Lim, Young Kyung;Lee, Se Byeong;Shin, Dongho
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.144-148
    • /
    • 2017
  • When a high density metallic implant is placed in the path of the proton beam, spatial heterogeneity can be caused due to artifacts in three dimensional (3D) computed tomography (CT) scans. These artifacts result in range uncertainty in dose calculation in treatment planning system (TPS). And this uncertainty may cause significant underdosing to the target volume or overdosing to normal tissue beyond the target. In clinical cases, metal implants must be placed in the beam path in order to preserve organ at risk (OARs) and increase target coverage for tumors. So we should introduce Ti-mesh. In this paper, we measured the lateral dose profile for proton beam using an EBT3 film to confirm dosimetric impact of Ti-mesh when the Ti-mesh plate was placed in the proton beam pathway. The effect of Ti-mesh on the proton beam was investigated by comparing the lateral dose profile calculated from TPS with the film-measured value under the same conditions.

A Study on the Ornamental Metal Used in the Roof of Ancient Architecture in Korea (고대 건축의 지붕부에 사용된 금속장식에 관한 연구)

  • Youn, Lily
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.2
    • /
    • pp.63-70
    • /
    • 2020
  • In the ancient Buddhist temple area, various metal artifacts are still excavated. Therefore, the aim of this study is to approach the characteristics of ancient architecture through ancient metal artifacts. First, metal decoration of ancient architecture appears for the purpose of structure, decoration, arson. Then, as the method of wood structure is developed, the application is separated into structural, functional and decorative purposes. In ancient times, metal decoration has reduced the role of structure, but its decorative role has expanded. Second, various metallic ornaments were used on the roof of ancient architecture. As the wooden technology developed, the metal decoration was gradually omitted while applying the curve to the roof. Third, the metal ornaments used on the roof of ancient architectures include the ridge central decoration, roof top decoration, a nine-ring decoration, gable board Ornamental Metal, corner flower decoration, eaves nail, wind bell. And subsequent research requires a terminology that can link the results of archeology and Buddhist art through excavation as a result of architecture.

Non-Destructive Scientific Analysis of the Gold Fabric Excavated of Cheongsong Shim's Grave (청송심씨 묘에서 출토된 금직물의 비파괴 과학적 분석)

  • Lee, Hwang-Jo;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.38 no.3
    • /
    • pp.243-253
    • /
    • 2022
  • Using non-destructive analytical methods, we identified the material characteristics of two gold fabric artifacts excavated from the Cheongsong Sim clan (Bugeum Wonsam, Jikgeum Chima), including the artifact condition, fiber type, surface contamination, and metallic threads. We found that the artifacts were buried and had turned brown; thus, we were unable to determine their original color. The fiber type was determined to be silk from cocoons, based on scanning electron microscopy, Fourier transform infrared (FT-IR) analyses of Amide I, II, III, and IV peaks, and color reactions Further, the FT-IR and X-ray fluorescence (XRF) analyses identified the white and black stains as natural resin hydrolyzed substances, such as lipids and proteins, that occurred as microbial decomposition due to body decay. Finally, the XRF analyses identified the thin gold layer of the metallic yarn as gold (Au). According to the FT-IR data and the color reaction to the metallic yarn medium, the adhesive component of the medium was a product of-Amides I, II, III, and 3000 cm-1 within Amides A and B (an animal type), respectively. Thus, the medium was identified as Hanji (Korean paper), which is made from domestically produced Broussonetia kazinoki fibers.