• Title/Summary/Keyword: Metallic Plate

Search Result 212, Processing Time 0.029 seconds

STRESS ANALYSIS ON THE DIFFERENT CLASPS OF THE REMOVABLE PARTIAL DENTURE BY THREE-DIMENSIONAL FINITE ELEMENT METHOD (삼차원 유한 요소법에 의한 가철성 국소의치 클래스프의 응력 분석)

  • Park Hong-Ryul;Kim Seong-Kyun;Koak Jai-Young;Heo Seong-Joo;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.218-231
    • /
    • 2005
  • Statement of problem. In the partially edentulous patients, removable partial dentures have been working as a important treatment modality. Clasps, a kind of direct retainers, received some amount of stresses during the insertion and removal of partial denture on the abutment tooth. Purpose. The study is to investigate stresses of the different clasps. Material and methods. In order to investigate the degree of stresses, maxillary partial edentulism (Kennedy Class II modification I) was assumed and removable partial dentures were designed on it with three kinds of metallic materials; cobalt-chromium alloy, type IV gold alloy and commercially pure (c.p.) titanium. Aker's clasp was applied on the left second molar. RPA (mesial rest-proximal plate-Aker's) clasp was on the left first premolar and wrought wire clasp was on the right first premolar. Three dimensional, non-linear, dynamic finite element analysis method was run to solve this process. Results. 1. Cobalt-chromium alloy had the highest von Mises stress value and c.p. titanium had the lowest one irrespective of the types of clasps. 2. In the Aker's clasps, stress on the retentive tips was shown shortly after the appearance of stresses of the middle and minor connector areas. These time lag was much shorter in the RPA clasps than in the Aker's clasp. 3. In general. retentive tips of wrought wire clasps had much less amount of stress than other clasps. Conclusion. The amount of stress was the highest in the RPA clasp and the lowest in the wrought wire clasp, in general.

Report on the Conservation Treatment for the Artifacts Exhibited in the newly-opened Kimhae National Museum (국립김해박물관(國立金海博物館) 개관(開館) 전시유물 보존처리 보고(報告))

  • Kwon, Hyuk-nam;Ahn, Byong-chan
    • Conservation Science in Museum
    • /
    • v.1
    • /
    • pp.15-26
    • /
    • 1999
  • More than 200 objects selected for the newly-opened Kimhae National Museum were treated for conservation. The objects which represent ancient Kaya culture, were mainly composed of metallic such as gilt bronze, silver, copper alloy and iron. The corrosion products on gilt bronze and copper alloy objects were preserved or removed according to their stability. Minimum treatment was done for preserving the original state of the objects. For silver objects and iron objects with silver-plate decorations, silver surfaces were revealed after treatment of corrosion products and treatments to prevent corrosion of silver and iron were done emphatically. For iron objects, which were stabilized, the original shape of objects was restored and acrylic coating was applied to prevent further corrosion. For the objects which were being corroded, 2-step de-chloride treatments were undertaken. The first step was immersing the objects in a solution of 0.3M sodium hydroxide and the second was the pressure de-chloride treatment using borax-distilled water. The main purpose of those treatments was to get rid of the causes of corrosion. Besides, conservation treatments for potteries, making of special mounting board for exhibition and amendment of various modeling were done too.

Application of Silicon Sludge from Semiconductor Manufacturing Process as Pigments and Paints through Titanium Dioxide Coating (반도체 제조공정에서 발생하는 실리콘 슬러지의 이산화티타늄 코팅을 통한 안료 및 도료 소재로의 응용)

  • Yeon-Ryong Chu;Minki Sa;Jiwon Kim;Suk Jekal;Chan-Gyo Kim;Ha-Yeong Kim;Song Lee;Hyung Sub Sim;Chang-Min Yoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.3
    • /
    • pp.35-41
    • /
    • 2023
  • In this study, silicon sludge generated in semiconductor manufacturing process is recycled and applied as materials for pigments and paints. In detail, metallic impurities are removed from silicon sludge to obtain plate-like silicon sludge powder (SW-sludge), which is then coated with titanium dioxide via sol-gel method (TCS-sludge). SW-sludge and TCS-sludge are dispersed in hydrophilic transparent varnish and sprayed onto glass substrates to observe the possibility for the application as materials for pigments and paints. Notably, the applicability of TCS-sludge-based paint is improved compared to SW-sludge-based paint after the titanium dioxide coating. Moreover, the color of TCS-sludge-based paint turns into white. Accordingly, it is confirmed that the applicability and hydrophilicity are improved by the presence of outer titanium dioxide layer. In this regard, it is expected that the recycled TCS-sludge may be a future material for the application as pigments and paints.

Clinical Results of Lateral-Posterior Internal Fixation for the Treatment of Scapular Body Fractures (견갑골 체부 골절에서 외측 후방 금속판 고정술의 치료 결과)

  • Lee, Yoon-Min;Yeo, Joo-Dong;Song, Seok-Whan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.46-53
    • /
    • 2020
  • Purpose: Scapular body fractures have generally been treated with non-surgical methods. This study reports the clinical and radiological outcomes after lateral-posterior internal fixation for treating displaced scapular body fractures. Materials and Methods: From March 2007 to May 2017, out of 40 patients who underwent internal fixation for scapular fractures, 13 cases of lateral plate fixation of a scapular body fracture were reviewed retrospectively. Preoperative and postoperative displacement, angulation and glenopolar angle (GPA) were measured. The range of shoulder motion, visual analogue scale (VAS), and disabilities of the arm, shoulder, and hand (DASH), and Constant score were assessed at the last follow-up. Results: The mean follow-up period was 17.7 months (range, 6-45 months). The mean preoperative GPA was 23.3°±3.96° (range, 17.8°-28.1°) and the postoperative GPA was 31.1°±4.75° (range, 22.5°-40.1°). Injury to the suprascapular nerve, nonunion, fracture redisplacement, metallic failure, or infection did not occur. At the last follow-up, the mean range of motion was 150.5°±19.3° in forward flexion, 146.6°±2.34° in lateral abduction, 66.6°±19.1° in external rotation, and 61.6°±18.9° in internal rotation. The VAS, DASH, and Constant scores were 1.7±1.3, 6.2±2.4, and 86±7.9 points, respectively. Conclusion: A scapular body fracture with severe displacement, angulation and marked decreased GPA can be stabilized by lateralposterior plate fixation using the appropriate surgical technique with good functional and radiological results.

A CLINICAL STUDY OF BIODEGRADABLE PLATES AND SCREWS IN ORAL AND MAXILLOFACIAL SURGERY (구강 악안면 영역의 생체 흡수성 고정판 사용에 관한 임상 연구)

  • Kim, Il-Kyu;Park, Seung-Hoon;Jang, Keum-Soo;Yang, Jung-Eun;Jang, Jae-Won;Sasikala, Balaraman
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.6
    • /
    • pp.451-458
    • /
    • 2009
  • Metallic bone plates and screws have been commonly used in oral and maxillofacial surgery for internal fixation. However, there are several disadvantages such as atrophy of cortical bone inherent to excessive rigid fixation systems, growth disturbance in growing individual, allergy reaction, interference with radiographic imaging, palpability, thermal sensitibity and the need for subsequent removal. To overcome these disadvantages and avoid additional surgery of removal of plates and screws, there have been many studies of biodegradable plates and screws. But, It also has complication such as foreign body reactions. We have undertaken a clinical and retrospective study on 140 patients in Dept. of Oral and Maxillofacial Surgery, Inha University Hospital from February 2006 to March 2009. The purpose of this study is to report the clinical cases and review of the literatures with biodegradable plates and screws. And we concluded following results. 1. 6 cases(3.4%) of the 177 operation sites(140 patients) experienced complications. 1 case(0.6%) was a failure of initial fixation, 1 case(0.6%) was a postoperative infection, 4 cases(2.3%) were inflammations or foreign body reaction. 2. Postoperative infections, inflammations and foreign body reactions were completely recovered with incision and drainage, supporative care with antibiotic coverage and removal of biodegradable plates. 3. Biodegradable plates and screws provide acceptable rigidity and stability clinically. But, long-term observation is required for the tissue reactions around the biodegradable plates and screws because of long resorption periods of the biodegradable materials.

Study on the Nonlinear Electromagnetic Acoustic Resonance Method for the Evaluation of Hidden Damage in a Metallic Material (금속 재료의 잠닉손상 평가를 위한 비선형 전자기음향공진 기법에 관한 연구)

  • Cho, Seung-Wan;Cho, Seung-Hyun;Park, Choon-Su;Seo, Dae-Cheol;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.277-282
    • /
    • 2014
  • Recently, much attention has been paid to nonlinear ultrasonic technology as a potential tool to assess hidden damages that cannot be detected by conventional ultrasonic testing. One nonlinear ultrasonic technique is measurement of the resonance frequency shift, which is based on the hysteresis of the material elasticity. Sophisticated measurement of resonance frequency is required, because the change in resonance frequency is usually quite small. In this investigation, the nonlinear electromagnetic acoustic resonance (NEMAR) method was employed. The NEMAR method uses noncontact electromagnetic acoustic transducers (EMATs) in order to minimize the effect of the transducer on the frequency response of the object. Aluminum plate specimens that underwent three point bending fatigue were tested with a shear wave EMAT. The hysteretic nonlinear parameter ${\alpha}$, a key indicator of damage, was calculated from the resonance frequency shift at several levels of input voltage. The hysteretic nonlinear parameter of a damaged sample was compared to that of an intact one, showing a difference in the values.

A STUDY FOR THE CHANGES OF THE MASTICATORY MUSCLES AND THE MANDIBULER MOVEMENT EFFECTED BY INTENTIONAL INCREASE OF ANTERIOR GUIDANCE ANGLE (전치 유도각의 인위적 증가에 의한 저작근과 하악 운동 양상의 변화에 대한 연구)

  • Lee, Yong-Sik;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.245-257
    • /
    • 1998
  • This study was performed to measure the changes of the mandibular movement and the masticatory muscular activities - anterior temporal and masseter muscle of both side - reflected by intentional increase of anterior guidance angie. For this study, 5 volunteers (3 males and 2 females with average age of 24.0) were selected. Each volunteer had Angle's classification I and did not have any missing tooth except third molar and any extensive restorations. Metallic guide plate was made at volunteer's working model fabricated by improved dental stone and cemented to the palatal surface of maxillary central incisor using resin cement(Panavia $21^{(R)}$) and then adjusted not to give any occlusal interferences at intercuspal position. The activity of masticatory muscles and the changes of mandibular movement were recorded by EMG and Sirognathograph in Biopak analysing system(Bioresearch Inc., Milwaukee, Wisconsin, USA). Measurement was done at before experiment, immediatley after placement, 1 week after placement, immediately after removal, and 1 week after removal. The results were as follows: 1. Moderate phonetic disturbance and mild headache were occured to 3 volunteers for 2 days after setting and 1 volunteer had positive reaction to percussion and slight midline diastema. But all of these clinical signs were diappeared 1 week after removal and the other volunteer did not have any special clinical sign. 2. In the EMG of the mandibular rest position, the mean value of anterior tempotal muscle was increased immediately after placement(p<0.01) and then decreased 1 week after placement(p<0.05) and increased 1 week after removal(p<0.05) but not recovered as before experiment. The mean value of masseter muscle was decreased during the experiment period. 3. In the EMG during mandibular protrusive movement, all muscular activity was decreased during the experiment period. Reduced activity was not recovered 1 week after removal(p<0.03). 4. During the habitual opening, anteroposterior movement of mandible was decreased immediately after placement(p<0.05) and then increased 1 week after placement but not statistically significant(p>0.1). Vertical movement was not shown significant difference during the experiment period(p>0.1). Lateral movement was decreased immediately after placement(p<0.05) and then increased 1 week after placement but not recovered as before experiment. The opening and closing velocity of mandible was shown minor changes but not statistically significant. 5. During the habitual opening, anteroposterior movement of mandible was decreased 1 week after placement(p<0.05) and then increased immediately after removal and recovered 1 week after removal as before experiment. Vertical movement was not shown significant changes. Lateral displacement of mandible was increased continuously and recovered 1 week after removal. Opening velocity was temporarily increased immediately after removal but recovered and closing velocity was not shown significant changes. 6. During the right side chewing, anteroposterior movement of mandible was increased immediately after removal but recovered and vertical movement was not shown statistically significant results. Lateral displacement and velocity of mandible were not shown significant results. 7. During the left side chewing, the changes of mandibular movement pattern were not shown statistically significant results.

  • PDF

Development of Advanced Manufacturing Process of Light Interference Pearl Pigment (광 간섭 펄 안료의 신규 제조 공정 개발)

  • Son, Hong Ha;Yu, Jae Won;Kim, Kyung Seob
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • In general, the pearlescent pigment is a pigment which was used for optical characteristics like pearl, rainbow and metallic luster. Titanium dioxide coated mica plate developed by DuPont in 1965 is currently being used as a main part of pearlescent pigment for cosmetics. Although the smooth and clear surface substrate laminated with 2 ~ 3 ingredients is thicker than a previous monolayer coated substrate, it has been applied for cosmetics as the optical interference powder to realize stronger shine and brighter interference color than monolayer one. In this study, we developed a new optical interference powder with thinner and higher chroma than a current pearlescent pigment for the strong luster and bright interference color. It was prepared from the manufacturing process, in which the coated titanium dioxide precursor was changed and crystallized by coating and heat treatment process with a half of dividing the coated amount of titanium dioxide. We confirmed the dense coating of titanium dioxide grain with Scanning Electron Microscope and measured superior crystallization degree compared with a monolayer coated pearlescent pigment by X-ray Diffraction. It is concluded that our new pearlescent pigment had higher reflectivity of light and stronger interference color than previous products.

Variation of Hydrogen Residue on Metallic Samples by Thermal Soaking in an Inert Gas Environment (불활성 가스하 열건조에 따른 금속시험편의 수소잔류물 거동 분석)

  • Lee, Yunhee;Park, Jongseo;Baek, Unbong;Nahm, Seunghoon
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.1
    • /
    • pp.44-49
    • /
    • 2013
  • Hydrogen penetration into a metal leads to damages and mechanical degradations and its content measurement is of importance. For a precise measurement, a sample preparation procedure must be optimized through a series of studies on sample washing and drying. In this study, two-step washing with organic solvents and thermal soaking in inert gas were tried with a rod-shaped, API X65 steel sample. The samples were machined from a steel plate and then washed in acetone and etyl-alcohol for 5 minute each and dried with compressed air. After then, the samples were thermally soaked in a home-made nitrogen gas chamber during 10 minute at different heat gun temperatures from 100 to $400^{\circ}C$ and corresponding temperature range in the soaking chamber was from 77 to $266^{\circ}C$ according to the temperature calibration. Hydrogen residue in the samples was measured with a hot extraction system after each soaking step; hydrogen residue of $0.70{\pm}0.12$ wppm after the thermal soaking at $77^{\circ}C$ decayed with increase of the soaking temperature. By adopting the heat transfer model, decay behavior of the hydrogen residue was fitted into an exponential decay function of the soaking temperature. Saturated value or lower bound of the hydrogen residue was 0.36 wppm and chamber temperature required to lower the hydrogen residue about 95% of the lower bound was $360^{\circ}C$. Furthermore, a thermal desorption spectroscopy was done for the fully soaked samples at $360^{\circ}C$. Weak hydrogen peak was observed for whole temperature range and it means that hydrogen-related contaminants of the sample surface are steadily removed by heating. In addition, a broad peak found around $400^{\circ}C$ means that parts of the hydrogen residue are irreversibly trapped in the steel microstructure.

Hypervelocity Impact Simulations Considering Space Objects With Various Shapes and Impact Angles (다양한 형상의 우주 물체와 충돌 각도를 고려한 우주 구조물의 초고속 충돌 시뮬레이션 연구)

  • Shin, Hyun-Cheol;Park, Jae-Sang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.12
    • /
    • pp.829-838
    • /
    • 2022
  • This study conducts Hypervelocity Impact(HVI) simulations considering space objects with various shapes and different impact angles. A commercial nonlinear structural dynamics analysis code, LS-DYNA, is used for the present simulation study. The Smoothed Particle Hydrodynamic(SPH) method is applied to represent the impact phenomena with hypervelocity. Mie-Grüneisen Equation of State and Johnson-Cook material model are used to consider nonlinear structural behaviors of metallic materials. The space objects with various shapes are modeled as a sphere, cube, cylinder, and cone, respectively. The space structure is modeled as a thin plate(200 mm×200 mm×2 mm). HVI simulations are conducted when space objects with various shapes with 4.119 km/s collide with the space structures, and the impact phenomena such as a debris cloud are analyzed considering the space objects with various shapes having the same mass at the different impact angles of 0°, 30° and 45° between the space object and space structure. Although space objects have the same kinetic energy, different debris clouds are generated due to different shapes. In addition, it is investigated that the size of the debris cloud is decreased by impact angles.