• 제목/요약/키워드: Metal-porcelain

검색결과 266건 처리시간 0.02초

표면 변화에 따른 주조용 티타늄 합금과 도재와의 결합강도 변화에 관한 연구 (A Study of Porcelain Bond Strength to Cast Ti Alloy with respect to Change of Surface Characteristic)

  • 정인성;최성민
    • 대한치과기공학회지
    • /
    • 제30권1호
    • /
    • pp.65-71
    • /
    • 2008
  • The use of titanium in the field of dentistry has increased, due to their excellent biocompatibility, appropriate mechanical properties, corrosion-resistance and low price. However, many difficulties with the use of titanium for metal-ceramic crowns remain to be solved. The objective of this study was to evaluate the influence of surface modifications on the bonding characteristics of specific titanium porcelain bonded to cast titanium. The surfaces of Titanium were prepared with 4 test groups, i) sandblasted with particles of different size, ii) sandblasted after treated oxidization and oxidized after sandblast. We observed the bond strength and node aspect of titanium and ceramic, and respect to the methods of modifying surface of titanium by the test of mean roughness of surface, Scanning Electron Microscope, and 3-point flexural bend test. The results show that, 1. The specimens, which treated oxidization after process of sandblast with particles of 50um size, were the better for the bond strength in comparison with other specimen. 2. The specimen with process of sandblasting after oxidization treatment were the better for stability of the bond strength. 3. The wettability of titanium surface affect the bond strength.

  • PDF

Celay System을 이용한 In-Ceram Alumina 3 Unit Bridge제작법 (THE CONSTRUCTION METHOD OF IN-CERAM ALUMINA 3 UNIT BRIDGE USING CELAY SYSTEM)

  • 조병완
    • 대한심미치과학회지
    • /
    • 제5권1호
    • /
    • pp.34-43
    • /
    • 1996
  • In nowdays many dental CAD/CAM system were developed. Among those only Cerec and Celay were used globally as clinical application. Celay is a machinable ceramic system that is capable of milling inlays, onlays, and veneers from prefabricated industrial ceramic blocks(Vita Celay Blanks). The advatages of Celay are to simplify the manufactures and to save the processing time. For esthetics In-Ceram Alumina bridges were introduced into maxillary anterior restoration. They have a high strength, a high translucency and an excellent marginal adapation. But the laboratory processes are very difficult and complicated. So the construction of In-Ceram Alumina bridge combined with celay system was desgined. The patient is a 28 year old age male. The chief complain is missing of maxillary left central incisor. He wants to restore anterior bridge for esthetically. The Alumina bridge framework was constructed easily by celay system. Glass ilfiltration was occurred. After that, vitadura-${\alpha}$porcelain build up was occurred by conventional method. The translucency of In-Ceram Alumina 3 unit bridge revealed to be superior to that of porcelain fused to metal bridge. So we report it with clincal case and literature reviews.

  • PDF

상용 치과 법랑질 도재의 광학적 및 기계적 특성 (Optical and Mechanical Properties of Commercial Dental Enamel Porcelain)

  • 박형랑
    • 대한치과기공학회지
    • /
    • 제26권1호
    • /
    • pp.115-128
    • /
    • 2004
  • In this study, optical and mechanical properties were investigated with 4 kinds of commercial dental enamels. As a result of EDS analysis $SiO_2,\;Na_{2}O,\;Al_{2}O_3\;and\;K_{2}O$ were the main components of commercial dental enamels. In case of H specimen, content of $SiO_2\;and\;K_2O$ were more than that of another specimens. Starting powder and fired specimens were glass ceramics which were consist of amorphous phase and leucite (crystalline) phase. Crystallization did not occurred during firing process, since the XRD peak intensity was similar between starting powder and fired specimens. As a result of differential thermal analysis, $T_g$ and crystalline temperature was varied with composition in the range of $548\sim576^{\circ}C$ and $735\sim780^{\circ}C$ respectively. 0.5mm thickness dental enamel specimens showed sufficient translucent properties. However, transmittance and reflectance were lower than 5% result from scattering due to the refractive index difference between glass and crystalline phase. 3 point bending strength was in the range of 73.9$\sim$101.8MPa which was similar or slightly higher than enamel of natural teeth and Vickers hardness was higher than enamel of natural teeth more than 100.

  • PDF

도재소부용 Ni-Cr합금의 적합성과 세포독성에 관한 연구 (A Study on the Adaptability and Cytotoxicity of Porcelain Bonded Ni-Cr Alloy)

  • 최부병;신명철
    • 대한치과보철학회지
    • /
    • 제20권1호
    • /
    • pp.7-17
    • /
    • 1982
  • In order to investigate the internal adaptability and cytotoxicity for porcelain fused to metal Ni-Cr alloy, two commercial alloys (Generic Gold-R alloy, Aalba Dent- Valloy)were employed and compared with new developed beryllium free Ni-Cr alloy (KIST-K alloy). After cementation of each crown to abutment die before and after ceramic bonding respectively, dies were mounted to epoxy resin and the internal space was measured between crown and die of each point on sagittal section. The results were as follows: 1) The results show that the space between the crown and the die was largest at the incisal edge, followed by the shoulder or the bevel and chamfer. The least was to be in the axial surface. 2) There were no significant difference in the adaptability of the compared alloys. 3) On day 2 of the experiment the cell multiplication was slightly inhibited by R and K alloys. However, observations taken at day 4 and 7 showed normal cell multiplication process compared to control group. 4) Alloy V exhibited the most severe cell toxicity among the alloys tested on day 2. By day 4 and 7 it showed a decrease level in toxicity, however it did not exhibit normal cell growth as compared to control group.

  • PDF

Fracture resistance and marginal fit of the zirconia crowns with varied occlusal thickness

  • Tekin, Yadel Hazir;Hayran, Yeliz
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.283-290
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the clinical applicability of monolithic zirconia (MZ) crowns of different thickness via determination of fracture resistance and marginal fit. MATERIALS AND METHODS. MZ crowns with 0.5, 0.8, 1.0, and 1.5 mm thickness and porcelain fused to metal (PFM) crowns were prepared, ten crowns in each group. Marginal gaps of the crowns were measured. All crowns were aged with thermal cycling (5 - 55℃/10000 cycle) and chewing simulator (50 N/1 Hz/lateral movement: 2 mm, mouth opening: 2 mm/240000 cycles). After aging, fracture resistance of crowns was determined. Statistical analysis was performed with one-way ANOVA and Tukey's HDS post hoc test. RESULTS. Fracture loads were higher in the PFM and 1 mm MZ crowns compared to 0.5 mm and 0.8 mm crowns. 1.5 mm MZ crowns were not broken even with the highest force applied (10 kN). All marginal gap values were below 86 ㎛ even in the PFM crowns, and PFM crowns had a higher marginal gap than the MZ crowns. CONCLUSION. The monolithic zirconia exhibited high fracture resistance and good marginal fit even with the 0.5 mm thickness, which might be used with reduced occlusal thickness and be beneficial in challengingly narrow interocclusal space.

배전선로용 폴리머 피뢰기의 모듈 설계/제조 및 성능 (Relief Performance of Fault Current and Design/Manufacturing of Polymer Arresters for Power Distribution)

  • 조한구;윤한수;장태봉;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.175-179
    • /
    • 2005
  • The main objective of this paper is to module design and pressure relief test a new type of polymer gapless surge arrester for power distribution line. Metal oxide surge arrester for most electric power system applications, power distribution line and electric train are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of gapless elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion.

  • PDF

도재용착주조관용 비귀금속 합금의 사전 열처리가 도재-금속의 결합 강도에 미치는 효과 (The Effect of Oxidation Heat Treatment on Porcelain to Metal Bond Strength)

  • 김치영;남상용
    • 대한치과기공학회지
    • /
    • 제19권1호
    • /
    • pp.37-42
    • /
    • 1997
  • The interfacial bond strengh and microstructural analysis of pre-heat treated porcelain-fusedmetal(PFM) were investigated using a mechanical three-point bending tester and scanning electron microscope(SEM). Four kinds of heat treated samples were prepared as follows ; A: Heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating ${\to}1850^{\circ}F$, hold 3min under vacuum, B: heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating${\to}1850^{\circ}F$ under vacuum conditon, C: heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating${\to}1850^{\circ}F$, holding 3min in the air, repeat same heat treatment process under vacuum condition, D: heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating${\to}1850^{\circ}F$, holding 1min in the air. The three-point bening test result shows that the interfacial bond strength of specimen B and C were higher than that of A and D. The SEM study indicate that Specimen C shows the highest surface density.

  • PDF

도재용 Ni-Cr 합금표면의 열처리후 원소성분 변화 (Surface Elemental change of dental Ni-Cr Alloy for Porcelain after Heat Treatment)

  • 남상용
    • 대한치과기공학회지
    • /
    • 제17권1호
    • /
    • pp.5-9
    • /
    • 1995
  • This study was carried out by obsorving to the conditions of an oxide on the surface of alloy according to the conditions of its heat treatment and analysing the change in composition on its surface. The result of this study is summarized as fellows. 1. It was shown that the higher the more the generated metal oxide while the higher the temperature of heat treatment. 2. The metal oxide was manily composed of Ni and Cr oxides. 3. The Ni composition indicated reduction while the higher the heat treatment in vaccum condition. 4. The Cr composition indicated increase while the higher the heat treatment in vaccum condition.

  • PDF

두 종류의 CAD/CAM 지르코니아 전부도재관의 도재 축성 전후의 변연적합도 비교 (Comparison of marginal fit before and after porcelain build-up of two kinds of CAD/CAM zirconia all-ceramic restorations)

  • 신호식;김석규
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.528-534
    • /
    • 2008
  • 연구목적: 변연적합도는 보철수복물의 성공을 좌우하는 중요한 요소 중의 하나이다. McLean과 von Fraunhofer등에 의하면 120 ${\mu}m$ 이하를 임상적으로 허용할 수 있다고 했는데, 이를 넘는 정확하지 않은 변연은 지각과민을 일으키거나 이차 우식을 일으키고, 치태 축적을 용이하게 하여 보철물의 수명을 단축시키게 된다. 이에 최근에 우리나라에 소개되어 임상적으로 사용되고 있는 CAD-CAM 전부도재 수복물 중 $LAVA^{(R)}$ 시스템 (3M ESPE, St. Paul, MN)과 $EVEREST^{(R)}$ 시스템 (KaVo Dental GmbH, Biberach, Germany)으로 제작한 지르코니아 전부 도재관들이 도재전장 금속주조 수복물과 비교해 보아 코핑 상태일 때와 도재축성 후 각각 변연적합도의 차이가 있는지를 살펴보고자 하였다. 재료와 방법: 상악 제1소구치 덴티폼 치아를 high speed diamond bur 로 교합면 2.0 mm, 순설면 1.0 mm, 그리고 변연은 chamfer margin을 6도 측면 경사 절삭 기계로 균일하게 제작해서 이를 인상 채득하여 금속 지대치를 제작하였다. 이를 덴티폼 모형상에 장착한 후 전악인상을 채득하여 $LAVA^{(R)}$ 수복물 코핑, $EVEREST^{(R)}$ 수복물 코핑, 그리고 도재전장 금속주조 수복물 코핑을 각각 8개씩 제작하였다. 이들 코핑을 염색제를 섞은 Fit-checker $II^{(R)}$ (GC Cor., Tokyo, Japan)를 이용하여 금속 지대치에 접합시킨 뒤, $Microhiscope^{(R)}$ system (HIROX KH-1000 ING Plus, Seoul, Korea)을 이용하여 300배율로 관찰하면서 변연 간격을 ${\mu}m$단위로 측정하였다. 도재축성 후에도 마찬가지 방법으로 모든 수복물의 변연간격을 측정하여 통계 처리를 하였다. 결과: 코핑 상태에서의 평균 변연간격 값은 $EVEREST^{(R)}$ 에서 $52.00{\pm}11.94\;{\mu}m$, $LAVA^{(R)}$$ 56.97{\pm}10.00\;{\mu}m$, 그리고 도재 전장 금속 주조 수복물은 $97.38{\pm}18.54\;{\mu}m$를 보였고, 도재축성 후에 평균 변연 간격값은 $EVEREST^{(R)}$$61.69{\pm}19.33\;{\mu}m$, $LAVA^{(R)}$$70.81{\pm}12.99\;{\mu}m$, 그리고 도재 전장 금속 주조 수복물은 $115.25{\pm}23.86\;{\mu}m$를 보였다. 결론: 1. $LAVA^{(R)}$$EVEREST^{(R)}$ 수복물은 도재 전장 금속 주조 수복물과 비교하여 각각 코핑상태일 때와 도재 축성 후 모두 유의성 있는 (P < .05) 차이를 보이는 우수한 변연 적합도를 나타내었다. 2. $LAVA^{(R)}$$EVEREST^{(R)}$ 수복물 간의 평균 변연 간격 비교에서 코핑 상태일 때와 도재 축성 후에 모두 유의성 있는 차이는 없었다 (P > .05). 3. $LAVA^{(R)}$$EVEREST^{(R)}$ 그리고 PFM 은 각각 코어 상태일 때와 비교하여 도재 축성 후 변연 간격에서 약간 증가되었으나 유의성 있는 차이를 보이지는 않았다 (P > .05).

부산지역(釜山地域) 개업치과(開業齒科)의 치과보철물(齒科補綴物)에 관(關)한 만족도(滿足度) 조사(調査)(I) - 일부정식 치과 보철물에 관하여 - (A Study on Satisfaction of Practicing Dentists about Prosthesis in Pusan Part I : About Fixed Prosthetic appliances)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제10권1호
    • /
    • pp.159-169
    • /
    • 1988
  • Fixed prosthetic appliance is the restorations of damaged teeth with cast metal or porcelain, and of replacing missing teeth with fixed, or cemented prosthesis. Successfully treating a patient by means of fixed prosthodontics requires the thoughtful combination of dentist and dental laboratory technician. In order to know the satisfaction of dentisits about fixed prosthetic appliances-porcelain, precious and non precious metal-, this study was conducted for 69 practicing dentisis in Pusan during Fed. to Mar. 1988 using a questionnaire method and was analyzed by the use of percentage, $X^2$-test The results are obtained as follow: 1. General characteristics of the respondents, The rate of age distribution of practcing dentists responded was as follow : 31$\sim$35 age group is 29.0%, 51$\sim$55age group 18.8%, 41$\sim$45 age group and 46$\sim$50 group each 11.6%, 36$\sim$40 age group and 56$\sim$60 age group 8.7%, over 60 age group 7.3%, below 30 age group 4.3% respectively. The tate of term of practice experience distribution of dentists responded was as follow : 6$\sim$10 year group 26.1%, 25$\sim$25year group 18.8%, 11$\sim$15 years group and 16~20 years group each 13.0%, below 5 years group and over 30 years group each 10.2%, 26$\sim$30 years group 8.7% in order. The rate of respondents’ degree was follow : bachelor group 81.2%, doctor group 13.0%, master group 5.8% in order. The rate of respondents’completed medical specialist course was as follow : non-complete group 75.4%, complete group 24.6%. The rate of having own laboratory in respondents’clinic was as follow : no having own laboratory group 58.0%, having own labiratory group 42.0% The rate of being lab. technician in respondent;s clinic was as follow: non-being lab. technician group 91.3%, being lab. technician group 8.7%. The rate of transactional commercial dental lab. numbers was as follow : I dental lab. group 40.6%, 2 dental lab. group 30.4%, 3 dental lab. group 20.3%, production at own lab. group 8.7% 2. Cognitions about the respondent's job, About cognition of patient numvers, there were neither many nor few group 62.3%, few group 17.4%, many group 15.9%, too many group 4.4% in order.(P<.01) As compared with the ratio of dentists to patient prothetic treatment, there were moderate level group 46.4%, high level group 33.6%, low level group 18.8% in order.(P<.01) By job satisfaction of respondents, the highest percentage group was satisfied group 44.9%, neither astisfied nor disstified group 33.3%, dissatisfied group 14.5%, much satisfied group 7.3%(P<.01). As compared with the level of prosthetics price, the were moderate level group 71.0%, low level group 23.2%, high level group 5.8%(P<.01) 3. Satisfaction and assessment of dissatisfied factor of the fixed prosthetic appliance, As compared with the satisfaction of al prosthetic appliance, there were neither satisfied nor dissatisfied group 59.4%, satisfied group 20.3% dissatisfied group 18.8%, much satisfied group 1.5% in order.(P<.01). About precious and non precious metal crown and bridge, there were neither satisfied nor dissatisfied group 60.9%, satisfied group 24.6%, dissatisfied group 11.6%, much satisfied group 2.9% in order.(P<.01) The reat of respondent;s satisfaction about porcelain crown and bridge was as follow : neither satisfied nor dissatisfied group 43.5%, dissatisfied group 33.3%, satisfied group 21.7%, much satisfied group 1.5%(P<.01). The rate of respondent's dissatisfied factor item of precious and non precious metal crown and bridge was as follow : inadequate margin fit item 39.1% respondent, inadequate occlusion item 24.6%, inadequate adaptation item 23.2%, poor anat omic form item 15.9%, inadequate contact item 31.9%, improper polishing item 4.4%, the rest item 11.6% respectively. The rate of respondent's dissatisfied factor item of porcelain crown and bridge was as follow : inadequate margin fit item 52.2%, inadequate occlusion item 2.9%, inadequate adaptation item 10.1%, poor anatomic form item 11.6%, improper polishing item 1.5%, shade mismatching item 71%, the rest item 7.2% respectively. The rate of cognition of respondents’ about cause of dissatisfied factor on fixed prosthetic appliance by item was as follow : deficiency of sincerity item 55.1%, deficiency of knowledge about work item 47.8%, deficiency of experience item 15.9%, poor quality of using material item 5.8%, the rest item 2.9% respectively.

  • PDF