• Title/Summary/Keyword: Metal-framework

Search Result 258, Processing Time 0.022 seconds

A COMPARATIVE STUDY ON THE FRACTURE STRENGTH AND MARGINAL FITNESS OF FIBER-REINFORCED COMPOSITE BRIDGE (섬유강화형 복합레진브릿지의 파절강도 및 변연적합도에 관한 연구)

  • Choi Ho-Kuen;Shin Sang-Wan;Lim Ho-Nam;Suh Kuyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.526-546
    • /
    • 2001
  • Fiber-reinforced composite(FRC) was developed as a structural component for dental appliances such as prosthodontic framework. FRC provides the potential for fabrication of a metal-free, excellent esthetic prostheses. It has demonstrated success as a result of its simple fabrication, natural colour, and marginal integrity, and fracture resistance of veneering composite resin and the FRC material. Although it has lots of merits, clinical and objective data are insufficient. The purpose of this study was to evaluate the fracture strength and the marginal fitness of fiber reinforced composite bridge in the posterior region for clinical application. Sixteen bridges of each group. $Targis/Vectris^{(R)}$, $Sculpture-Fibrekor^{(R)}$, and In-Ceram, were fabricated. All specimens were cemented with Panavia 21 to the master dies. Strength evaluation was accomplished by a universal testing machine (Instron). The marginal fitness was measured by using the stereoscope (${\times}50$). The results were as follows. : 1. The fracture strength according to the materials was significantly decreased in order In-Ceram($238.81{\pm}82$), Targis Vectris($176.25{\pm}18.93$), Sculpture-Fibrekor($120.35{\pm}20.08$) bridges. 2. FRC resin bridges were not completely fractured, while In-Ceram bridges were completely fractured in the pontic joint. 3. The marginal accuracy was significantly decreased in order Targis/Vectris ($60.71{\mu}m$), Sculpture-Fibrekor($73.10{\mu}m$) In-ceram Bridge ($83.81{\mu}m$). 4. The fitness of occlusal sites had a lower value than the marginal sites(P<0.001), and the marginal gaps of inner site of the pontic were greater than that of outer sites of the pontic. Fiber reinforced composite bridges are new, esthetic prosthesis and can be clinically used in anterior regions and short span bridges. However, caution must be exercised when extrapolating laboratory data to the clinical situation because there are no long term clinical data regarding the overall success of the FRC.

  • PDF

Usable Capacity for CO2 capture and storage in MOFs (금속 유기 골격체를 활용한 사용 가능한(Usable capacity) 이산화탄소 포집 연구)

  • Park, Seoha;Oh, Hyunchul;Jang, Haenam
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.80-85
    • /
    • 2018
  • Usable capacity is one of the most important parameters for evaluating the performance of an adsorbent for $CO_2$ capture from flue gas streams. In the pressure swing adsorption (PSA) process, the usable capacity is calculated as the difference between the quantity adsorbed in flue gas at high pressure (ca. 20 bar) and the quantity adsorbed at lower purge pressure (ca. 2 bar). In this paper, two stereo-types of metal-organic framework (MOF) were evaluated as an promising adsorbent for $CO_2$ capture: flexible structured MOF (MIL-53) and MOF possessing strong binding sites (MOF-74). The results showed that a total $CO_2$ capture capacity is strongly related to the specific surface area and heat of adsorption, revealing high uptake in MOF-74. However, the usable capacity was more pronounced in MIL-53 due to a structural transition.

Full mouth rehabilitation of patient with severe dental caries with implant fixed prosthesis fabricated with milling and 3D printing method: A case report (밀링 및 3D 프린팅 방법으로 제작된 임플란트 보철물을 이용한 심한 우식 환자의 완전 구강 회복 증례)

  • Kim, Taeyoon;Lee, Jun-Suk;Hong, Seoung-Jin;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.288-295
    • /
    • 2019
  • Passive fit of prosthesis is an essential property of implant supported prosthesis for long term success and minimization of complications. And the property is determined mostly by fabrication procedure. There were limitations of extensive implant prosthesis because conventional casting method generate contraction error of long span prosthesis. However, Computer-aided design/Computer-aided manufacturing (CAD/CAM) technology of 3D printing and milling metal framework can overcome those limitations. This case is a full mouth rehabilitation using extensive implant fixed prosthesis. Removable interim prosthesis was made for esthetic, functional evaluation and a guide for implant insertion. After the insertion, implant fixed interim prosthesis was delivered. After additional evaluation and adjustment, final prosthesis was designed with CAD, the fabricated with CAM. Milling technique was used for anterior screw type implant superstructure and 3D printing technique was used for the anterior and posterior implant copings. Fit of the final restoration was favorable. The practitioner and patient were both esthetically and functionally satisfied with the final result.

Synthesis and Characterization of Zeolite Using Water Treatment Sludge (정수슬러지를 이용한 제올라이트의 합성 및 특성연구)

  • Ko, Hyun Jin;Ko, Yong Sig
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.263-269
    • /
    • 2020
  • Zeolite was synthesized hydrothermally using the water-treatment sludge, and the effects of various synthesis parameters like reaction temperature, reaction time, and Na2O/SiO2 molar ratio on the crystallization of zeolite were investigated. Crystal structure, physical property, and thermal stability of zeolite crystals were characterized by X-ray powder diffraction, FTIR spectroscopy, BET nitrogen adsorption, and TGA measurements. The removal efficiencies of nitrogen in ammonia, heavy metal ions, and TOC were calculated to evaluate zeolite's adsorption capacity. The primary chemical composition of water-treatment sludge was 28.79% Al2O3 and 27.06% SiO2. The zeolites were synthesized by merely employing the water-treatment sludge as silica and alumina sources without additional chemicals. Zeolite crystals synthesized through the water-treatment sludge were confirmed as an A-type zeolite structure. Zeolite A had the highest crystallinity obtained from a gel with the molar composition 2.1Na2O-Al2O3-1.6SiO2-65H2O after 5 h at a temperature of 90 ℃. The specific surface area of zeolite obtained was 55 ㎡ g-1, which was higher than commercial zeolite A. The removal efficiency of nitrogen in ammonia was 68% after 3 h of reaction time, while the removal efficiencies of Pb2+ and Cd2+ ions were 99.1% and 99.3%, respectively. These results indicate active ion exchange between Pb2+ or Cd2+ ion and Na+ ion in the zeolite framework. The adsorption experiments on the different zeolite addition conditions were performed for 3 h with 300 ppm humic acid. Based on the results, TOC's highest efficiency was 83% when 5 g of zeolite was added.

Three-dimensional finite element analysis for the effect of retentive groove design on joint strength of casting connection (유지구 설계가 주조연결강도에 미치는 영향에 관한 삼차원 유한요소법적 연구)

  • Kim, Jung-Woo;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.29-38
    • /
    • 2009
  • Statement of problem: A casting connection technique is widely used for repair, correction and addition to base metal framework. However, a casting connection technique may increase the risk of failure in clinical situations when high stresses exist. Purpose: The purpose of this study was to investigate the mechanical retentive groove design comparatively to increase the joint strength by using the three-dimensional finite element analysis model of a 3-unit fixed partial denture. Material and methods: Ten finite element models were constructed. (Model A: One retentive groove, Model B: Two retentive grooves, Model C: Three retentive grooves, Model D: Four retentive grooves, Model E: One horizontal groove and two vertical grooves, Model F: Two horizontal grooves and one vertical groove, Model G: One groove with the enlarged dimension, Model H: Two grooves with the enlarged dimension, Model I: One groove with the increased height, Model J: One groove with the increased width of base). The vertical force was applied to the mesial and the distal fossa to the casting connection of mandibular first molar. Results: The main factors, affecting joint strength of casting connection were both the retention between the primary cast and the secondary cast and the thickness of the primary cast remaining after preparing retentive groove. The increase of retentive force, according to the numbers and the dimension of retentive groove had an effect on distributing stress. However, in some cases, the increase of retentive force resulted in the increase of stress by reducing thickness of the primary cast in the connection area. Conclusion: The design of retentive groove that limits number of retentive groove for metal thickness and increases the depth of retentive groove for retention is highly recommended.

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

Two Crystal Structures of the Vacuum-Dehydrated Fully $Ag^+$-Exchanged Zeolite X ($Ag^+$ 이온으로 완전히 치환되고 탈수된 두개의 제올라이트 X의 결정구조)

  • Jang, Se Bok;Park, Sang Yun;Song, Seong Hwan;Jeong, Mi Suk;Kim, Yang
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.7
    • /
    • pp.474-482
    • /
    • 1996
  • Two crystal structures of the vacuum dehydrated $Ag^+$-exchanged zeolite X have been determined by single-crystal X-ray diffraction techniques in the cubic space group Fd3 at 21(1)$^{\circ}C$ (a=24.922(1)${\AA}$ and a=24.901(1)${\AA}$, respectively). Each crystal was ion exchanged in flowing streams of aqueous $AgNO_3$ for three days. The first crystal was dehydrated at 300$^{\circ}C$ and $2{\times}10^{-6$torr for two days. The second crystal was similarly dehydrated at 350$^{\circ}C$. Their structures were refined to the final error indices, $R_1=0.095\;and\;R_2=0.092$ with 227 reflections, and $R_1=0.096\;and\;R_2=0.087$ with 334 reflections, respectively, for which I > 3${\sigma}$(I). In the first crystal, Ag species are found at five different crystallographic sites: sixteen $Ag^+$ ions fill the site I, the center of the double 6-ring, thirty-two Ag0 atoms fill the I' site in the sodalite cavities opposite double six-rings, seventeen $Ag^+$ ions lie at the 32-fold site II' inside the sodalite cavity at the single six-oxygen ring in the supercage, fifteen Ag+ ions lie at the 32-fold site II, in the supercage, and the remaining twelve $Ag^+$ ions lie at site III' in the supercage at a little off two-fold axes. In the second crystal, all Ag species are located similarly as crystal 1; 16 at site I, 28 at site I', 16 at site II, 16 at site II', 6 at site III and 6 at site III'. Total 88 silver species were found per unit cell. The remaining four Ag atoms were migrated out of the zeolite framework to form small silver crystallites on the surface of the zeolite single crystal. In the first structure, the numbers of Ag atoms per unit cell are approximately 32.0 and these may form tetrahedral $Ag_4$ clusters at the centers of the sodalite cavities. The probable four-atom cluster is stabilized by coordination to two $Ag^+$ ions. The Ag-Ag distance in the cluster, ca. 3.05 ${\AA}$, is a little longer than 2.89 ${\AA}$, Ag-Ag distance in silver metal. At least two six-ring $Ag^+$ ions on sodalite cavity (site II') must necessarily approach this cluster and this cluster may be viewed as a distorted octahedral silver cluster, (Ag6)2+.

  • PDF

Comparative Compressional Behavior of Zeolite-W in Different Pressure-transmitting Media (제올라이트-W의 압력전달매개체에 따른 체적탄성률 비교 연구)

  • Seoung, Donghoon;Kim, Hyeonsu;Kim, Pyosang;Lee, Yongmoon
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.3
    • /
    • pp.169-176
    • /
    • 2021
  • This study aimed to fundamentally understand structural changes of zeolite under pressure and in the presence of different pressure-transmitting media (PTM) for application studies such as immobilization of heavy metal cation or CO2 storage using pressure. High-pressure X-ray powder diffraction study was conducted on the zeolite-W (K6.4Al6.5Si25.8O64× 15.3H2O, K-MER) to understand linear compressibility and the bulk moduli in different PTM conditions. Zeolite-w is a synthetic material having the same framework as natural zeolite merlinoite ((K, Ca0.5, Ba0.5, Na)10 Al10Si22O64× 22H2O). The space group of the sample was identified as I4/mmm belonging to the tetragonal crystal system. Water, carbon dioxide, and silicone-oil were used as pressure-transmitting media. The mixture of sample and each PTM was mounted in a diamond anvil cell (DAC) and then pressurized up to 3 GPa with an increment of ca. 0.5 GPa. Pressure-induced changes of powder diffraction patterns were measured using a synchrotron X-ray light source. Lattice constants, and bulk moduli were calculated using the Le-Bail method and the Birch-Murnaghan equation. In all PTM conditions, linear compressibility of c-axis (𝛽c) was 0.006(1) GPa-1 or 0.007(1) GPa-1. On the other hand, the linear compressibility of a(b)-axis (𝛽a) was 0.013(1) GPa-1 in silicone-oil run, which is twice more compressible than the a(b)-axis in water and carbon dioxide runs, 𝛽a = 0.006(1) GPa-1. The bulk moduli were measured as 50(3) GPa, 52(3) GPa, and 29(2) GPa in water, carbon dioxide, and silicone-oil run, respectively. The orthorhombicities of ac-plane in the water, and carbon dioxide runs were comparatively constant, near 0.350~0.353, whereas the value decreased abruptly in the silicone-oil run following formula, y = -0.005(1)x + 0.351(1) by non-penetrating pressure fluid condition.