• Title/Summary/Keyword: Messurement

Search Result 6, Processing Time 0.02 seconds

The Lateral Earth Pressure on Braced Cut Walls Considering Subsoil Condition in Korea (국내 지반조건을 고려한 흙막이 백제에 작용하는 토압)

  • Chae, Young-Su;Moon, Il
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.09a
    • /
    • pp.129-138
    • /
    • 1994
  • It is well recognized that accurate analysis of lateral earth pressure is very signficant factor which determines the design amount of braced cut walls and braced systems. Many researchers, Peck, Terzaghi-Peck and so on, make a study about lateral earth pressure to act on the flexible walls. But these studies trouble accurate to multy layered systems like inland areas in Korea. This study is compared with the field messurement data to estimate the earth pressure distributions in multy layered areas and the empirical earth pressure distributions. The conclusions are as follows : At final excavation depth, the lateral earth pressure which messured by field instrument is smaller than the empirical earth pressure. (About 1.85~5.32 times). In the case of considering the soft rock layer to the final excavation depth, the messured earth pressure is safe to be compared with empirical earth pressure. The messured earth pressure distributions are like that the upper soil layer is small the middle soil layer is large, the rock mass layer is very small.

  • PDF

Electrical Characterization of Organo Sulfur Compound-Polyphenylenediamine Positive Electrode in Lithium Battery (유기황화합물-Polyphenylenediamine리튬전지용 정극의 전기적특성)

  • 박수길;박종은;손원근;김상욱;임기조;이주성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.261-264
    • /
    • 1997
  • Polyphenylenediamine(PPD)film was prepared with organo sulfur compond (2-aminothiophenol, 1,2-ethanedithiol, and 2-aminoethaneethiol etc.) adding lithium salt to increase the electrical conductivity of the polymer surface. The molecular structure of conductive polymer synthesized were examined and discussed by using SEM, FT-IR, NMR etc. The elecrical conductivity messurement were carried out with four-probe method at dry box of He and $N_2$atmosphere. The typical value of successful electrical conductivity was 1.2$\times$10$^1$S/cm at room temperature.

  • PDF

ACCURACY OF CONE-BEAM COMPUTED TOMOGRAPHY IN PREDICTING THE DIAMETER OF UNERUPTED TEETH (Cone-beam computed tomography를 이용한 미맹출 영구치의 계측)

  • Kim, Seong-Hee;Kim, Young-Jong;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.139-144
    • /
    • 2012
  • The purpose of this study was to evaluate the accuracy and reproducibility of measuring the size of unerupted permanent tooth via cone beam computed tomography(CBCT). Ten children were scanned with dental CBCT, and 3-dimensional reconstruction of the dentitions were generated CBCT. Mesio-distal dimension and buccolingual dimension of the teeth were made directly on the model with a high-precision digitalcaliper and on the CBCT by using three-dimensional dental imaging software. Reliability and accuracy were assessed by using intraclass correlation and paired $t$-tests. ($p$ <0.05) The results were as follows : 1. Intraclass correlations were above 0.9 for Both the CBCT and the model measurements, showinghigh reliability. 2. Although there were high correlation values(r=0.91) between CBCT and model messurement methods, comparisons between the CBCT and model messurement methods showed a statistically significant difference($p$ <0.05). 3. The CBCT measurements tended to slightly underestimate by 0.2 mm. But, the systematic difference of CBCT measurements were clinically acceptable Therefore, CBCT measurement method can be used to measure the size of unerupted teeth in a sufficiently accurate way.

Geotechnical Approach in Design and Construction of Underground Structures A Systematic Parameter Estimation (지하 공간 설계와 시공의 지반공학적 접근과 실무적용 -지반계수의 합리적 추정)

  • Lee, In-Mo;Kim, Dong-Hyeon
    • Geotechnical Engineering
    • /
    • v.12 no.2
    • /
    • pp.43-58
    • /
    • 1996
  • In spite of drastic development of underground technology too many uncertainties still exist in design and construction of underground structures. Estimation of ground parameters might be one of those uncertainties in design of underground structures. It is not an easy task to estimate the parameters reasonably well in advance in the design stage. The main purpose of this paper is the best parameter estimation in the underground structures. In order to estimate unknown model parameters from the in-eitu measurements as well as prior estimates, the Extended Bayesian Method(EBM) is utilized and implemented with Finite Element Program. The parameter estimation model utilized in this study is applied to two underground structures : the one Pusan subway tunnel: and the other Darlington intake tunnel in Canada, and the effectiveness of the proposed model is illustrated.

  • PDF

Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant (난연성 폴리 올레핀 케이블 절연재료의 내화특성)

  • Yoon, Hun-Ju;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analyzed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC 600[V] wire. Messurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflaming pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of $2.5{\pm}0.04[w/cm^{2}]$ for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomplete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

Ecological Studies on Several Forest Communities in Kwangnung. A Study of the Site Index and the ground vegetation of Larch (광릉삼림의 생태학적 연구 낙엽송의 Site Index와 임상식생에 관하여)

  • 차종환
    • Journal of Plant Biology
    • /
    • v.9 no.1_2
    • /
    • pp.7-16
    • /
    • 1966
  • In order to determine the factors related to site quality, 13 areas of Larch growing in the Kwangung and its vicinity forest as sample plots, were examined. Sample plots included various site classes as well as age classes. Three were divided into two groups (major and minor trees). Average height of dominant trees was determined through messurement of 5 to 6 dominant tree in each sample plots. Average height of dominant 30 year-old trees was the basis for site index. A Standard Yield Table for the larch produced in Kwangnung forest was made by various data, which included age class 5, ranging from 10 to 45 years. The relationship of the height of the trees, the site conditions, and ground vegetation are investigated in this paper. The site indexes of 40 forest class age in 28-B and 28-G forest classes of the larch associations for ground vegetation had comparatively rarge differences due to the sampled areas. The relation of the direction of forest communities to the height and the diameter of the tree shwoed that its communiteis of northest and northwest parts appeared higher valueof the height and the diameter. The diameter and the height of trees were closely realted to each other. The samller the occupied area per tree and the smaller the average distance among trees, the more density was increased. The larger the density was the lower height of the trees. In the ground vegetation of the larch communities, there seems to be a definite correlation between the height of trees and the occupied area per tree or the average distance among the trees. The height of trees and site index of two larch communities were as follow: 28-B forest class site index 20.8, height 24.0m, 28-G forest class site index 18.4, height 20.9m. The ground layer was analyzed by the method of Quadrat(20/20sq. cm) with an interval of 1M. It set up 40 Quadrats of the larch communiteis. The community structure of the ground vegetation of two larch was analyzed, and important value was calculated and then evaluated. The ground vegetation under the larch had developed Burmannii Beauv stratal society below the 28-B and 28-G the forest class. Accordingly, the first important value of Burmannii Beauv was found in two ground vegetation below the larch. Therefore, this species could be quantitatively considered as the forest indicator species. Common species of each community appeared 18 species out of 34 species in the ground vegetation under two larch communities. The ground vegetation of the 28-B forest class showed more than that of the 28-G forest class. the similarity of the ground vegetation was measrued by the Frequency Index Community Coefficient. The differences between the associations were lcearly manifested by the ground vegetation tested by Gleason's Frequency Index of Community Coefficient for the analysis of each stratal society of all associations. According to F.I.C.C. the ground vegetation under two larch(28-B and 28-G) forest classes showed higher value. An investigation into the relationship of physical and chemical properties of soil and site was considered the next step to be taken in the study of the larch site classification.

  • PDF