• Title/Summary/Keyword: Mesh Pattern

Search Result 218, Processing Time 0.031 seconds

연안 요각류의 성체와 휴면란의 계절별 개체수 변화를 통한 개체군 유지 전략 (The Strategy of Population Maintenance by Coastal Copepod Inferred from Seasonal Variations in Abundance of Adults and Resting Eggs)

  • 박채린;주세종;박원규;김현우;이수린;박정호
    • Ocean and Polar Research
    • /
    • 제40권4호
    • /
    • pp.213-222
    • /
    • 2018
  • We investigated seasonal variations in the abundance of the adults and the resting eggs of copepods to understand the role of copepod resting eggs for maintaining their population inhabiting the coastal area of Dadaepo, Korea. Adults and resting eggs of copepods were collected bi-monthly with a conical net (45 cm mouth diameter, $330{\mu}m$ mesh size) and van Veen grab ($0.1m^2$ area), respectively, from October 2016 to September 2017. The species of resting eggs were identified using mtCOI gene. The mean abundance of copepods was highest in October ($3686{\pm}1190inds{\cdot}m^{-3}$) and lowest in January ($176{\pm}60inds{\cdot}m^{-3}$) with the dominance of Paracalanus parvus s.l.. Among copepod producing resting eggs, Acartia omorii and Centropages abdominalis were dominant. The mean abundance of resting eggs was the highest in July ($9148{\pm}6787eggs{\cdot}m^{-2}$) and the lowest in October ($530{\pm}348eggs{\cdot}m^{-2}$). Most of the collected resting eggs were identified as A. omorii's. The mean abundances of A. omorii adults and resting eggs were highest in July, and both abundances fluctuated in a similar pattern except in September. In September, A. omorii adults were observed in a state of low abundance, while their resting eggs occurred in a state of high abundance. These results suggest that A. omorii maintain their population by producing a large quantity of resting eggs, particularly diapause eggs, before the seawater temperature rises. These eggs would hatch and be newly recruited to their population when the environmental condition becomes favorable.

MEG4(Mooring Equipment Guideline 4) 적용에 따른 대용량 무어링 피팅 개발 (Development of the Large-Capacity Mooring Fittings according to MEG4(Mooring Equipment Guideline 4))

  • 이명수;서광철;박주신
    • 해양환경안전학회지
    • /
    • 제29권7호
    • /
    • pp.950-957
    • /
    • 2023
  • 선박이 부두에 안전하게 계류 및 예인하기 위해서는 관련 국제규정에 부합하는 설계를 해야 한다. 그러나 현재까지도 일부 소형 조선소 및 설계 회사에서는 그 내용을 정확히 숙지하지 못하고 있는 경우가 많다. 따라서 본 논문에서는 예인 및 계류설비에 관한 국제규정을 살펴보고, 최신 발효된 MEG4(Mooring equipment guideline 4) 기준에 만족하는 대표적인 계류 의장품인 볼라드(Bollard)와 쵸크(Chock)를 개발하고자 한다. 볼라드는 계류 밧줄을 선체에 고박하기 위한 의장품이며, 일반적으로 2개의 기둥으로, 대부분은 8자 매듭 형태로 사용하고 있다. 쵸크는 선외에서 선내로 들어오는 계류 밧줄의 방향을 전환하고, 밧줄의 손상을 방지하기 위하여 곡률을 갖는 주물방식으로 제작한다. 이 두 가지 계류 의장품은 선박의 선수와 선미, 중앙부 측면에서 많이 사용되고 있다. 최근 컨테이너선 및 LNG 운반선의 크기 증가로 인하여, 계류 밧줄 하중이 증가하고 있으며, 계류 의장품도 안전사용하중(Safe working load)이 변경되어야 한다. 본 연구에서는 유한요소해석 모델링을 통한 허용응력 평가법 결과를 정리하고, 분석하였다. 추가적으로 비선형 붕괴 거동 평가를 통하여, 안전사용하중 결정에 대한 검증을 수행하였고, 탄성영역 내 설계가 되었음을 확인하였다. 연구에서 제안하는 평가법 및 기준, 그리고 해석절차는 향후 유사 의장품 개발 시 참조가 가능하다.

스마트 액추에이터를 위한 폴리이미드 및 액정 엘라스토머 이중층의 미세패터닝 (Micropatterning of Polyimide and Liquid Crystal Elastomer Bilayer for Smart Actuator)

  • 성예린;최현승;송원성;바네사;김유리;류연해;김영진;임재민;김대석;최현호
    • 접착 및 계면
    • /
    • 제25권1호
    • /
    • pp.169-274
    • /
    • 2024
  • 최근 외부 자극에 따라 팽창과 수축을 가역적으로 반복하며 형태가 변하는 소재가 주목받고 있다. 이러한 소재는 소프트 로봇, 센서, 인공근육 등 다양한 분야로의 응용가능성을 가지고 있다. 본 연구에서는 고온 물질에 감응하여 이를 보호하거나 감쌀 수 있는 새로운 소재를 제안하였다. 이를 위해, 네마틱-등방성 전이 성질을 지닌 액정 엘라스토머(liquid crystal elastomer, LCE)와 높은 기계적 강도와 고온 수치 안정성을 지닌 폴리이미드(polyimide, PI)를 이용하였다. 용액공정으로 합성된 도프 용액을 마이크로 프린팅 기법에 도입하여 mm 미만의 마이크론 선폭을 지닌 LCE/PI 이중층 구조 2차원 패턴을 개발하였다. 벌집구조로 패턴된 LCE/PI 이중층 메쉬는 PI의 기계적 강도와 LCE 고온 수축 거동의 장점을 동시에 가지고 있었고, LCE 선택적 프린팅을 통해 고온에서 원하는 방향으로의 변형을 유도할 수 있었다. 그 결과, 특정 고온 물질을 가역 반복적으로 감쌀 수 있는 기능을 구현하였다. 본 연구는 LCE 분자 변화에 따라 다양한 온도 구간에서 전기에너지 인가없이 기능을 구현할 수 있는 다양한 액추에이터 분야의 응용 가능성을 시사한다.

유한요소모델에서 레버암을 이용한 상악 6전치 설측 견인 시 초기 이동 양상 (The Pattern of Initial Displacement in Lingual Lever Arm Traction of 6 Maxillary Anterior Teeth According to Different Material Properties: 3-D FEA)

  • 최인호;차경석;정동화
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.213-230
    • /
    • 2008
  • 최근 치료기간의 단축과 심미성을 동시에 충족시키는 6전치를 설측에서 견인하는 레버암을 이용한 견인방법이 사용되고 있다. 본 연구에서는 상악골의 고전적인 2가지 물성으로 구성된 유한 요소 모델 (단순모델)과 새로이 개발된 24가지 물성으로 구성된 모델 (복합모델)을 생성하여 상악 6전치를 후방 견인 시, 각 치아와 치주인대에 나타나는 초기 이동량과 응력분포를 분석하였다. 23세 성인 남자의 CT 촬영으로 얻은 DICOM 영상정보를 3차원 리버스 엔지니어링 컴퓨터영상프로그램 Mimics를 이용하여 상악골 및 상악 전치부의 3차원 입체영상모델로 재구성하여 finite element analysis (FEA) 모델을 완성하였다. 모델은 상악골, 상악 전치부 각 치아의 치주인대, lingual traction arm의 부분으로 구성되었다. 상악 6전치의 저항중심 부위를 지나도록 교합면에 대하여 평행하게 200g의 후방견인력을 적용한 후 나타나는 초기 이동량 및 응력 분포를 3차원 유한 요소법을 이용한 해석을 통해 비교하였다. 실험 결과 24가지 물성으로 구성된 복합모델이 2가지 물성으로 구성된 단순 모델에 비해 상악 중절치에서 보다 후방 이동되는 양상이 크게 나타났으며 수직적인 회전 양상 역시 크게 나타났다. 두 모델 모두 중절치와 측절치는 조절성 경사이동의 형태로 후방이동양이 견치보다 크게 나타났으나 견치는 이동량이 적은 대신 치근의 이동이 더 크게 나타났다. 수직적 이동양상에 있어 두 모델 모두 측절치와 견치의 접촉점을 중심으로 절치는 하방으로 견치는 상방으로 움직이는 회전양상을 나타났다. 응력의 비교에서는 단순 모델과 복합 모델에서 유사한 결과를 보였다. 비록 각기 다른 물성으로 인해 후방 이동량에서는 차이가 나타났으나 기본적인 치아의 이동양상은 두 모델에서 모두 같게 나타났다.

수종의 흡수성 차단막의 생체 분해도와 조직학적 반응 (Resorbability and histological reaction of bioabsorbable membranes)

  • 석헌주;권석훈;김창성;최성호;전동원;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제32권4호
    • /
    • pp.781-800
    • /
    • 2002
  • The major goals of periodontal therapy are the functional regeneration of periodontal supporting structures already destructed by periodontal disease. There have been many efforts to develop materials and therapeutic methods to promote periodontal wound healing. With the development of non-resorbable membrane, GTR has proved to be the representive technique of periodontal regeneration. However, due to various clinical problems of non-resorbable membrane, resorbable membrane was developed and it showed to be clinically effective. The newly developed Para-Dioxanone membrane has a characteristic of non-woven fabric structures which is different from the generally used membranes with structure of mesh form. In addition, Chitosan membrane has been developed to apply its adventage maximally in GTR. Although a number of different types of membranes had been clinically used, researches on absorption rate of membranes were inadequate and limited to subjective opinions. However, since long term period of resorption and space maintenance are required in implant or ridge augmentation, accurate verification of resorption rate is clinically important. In this study, we had implanted Resolut(R), Biomesh(R), Para-Dioxanone membrane and Chitosan membrane (Size : 4mm ${\times}$ 4mm) on dorsal side of Sprague Dawley rat, and sacrified them after 4 weeks, 8 weeks, 12 weeks respectively. Histologic observation was carried out, and the following results were obtained by calculating the objective resorption rate. 1. In case of Resolut(R), external resorption took place initially, followed by internal resorption. Surface area are 5.76${\pm}$2.37$mm^2$, 4.90${\pm}$l.06$mm^2$, 4.90${\pm}$0.98$mm^2$ at 4 weeks, 8 weeks, 12 weeks respectively, and invasion rate of connective tissue to membrane are 31.6${\pm}$4.5%, 52.8${\pm}$9.4%, 56.4${\pm}$5.1% respectively. 2. Biomesh(R) showed a pattern of folding, relatively slow resorption rate with small size of membrane. Surface area are 3.62${\pm}$0.82$mm^2$, 3.63${\pm}$0.76$mm^2$, 4.07${\pm}$1.14$mm^2$ at 4 weeks, 8 weeks, 12 weeks respectively, and invasion rate of connective tissue to membrane are 26.1${\pm}$5.8%, 30.9${\pm}$3.4%, 29.2${\pm}$3.6%, respectively. 3. Para-Dioxanone membrane was surrounded by fibrous conncetive tissue externally, and resorption took place internally and externally. Surface area are 5.96${\pm}$1.05$mm^2$, 4.77${\pm}$10.76$mm^2$, 3.86${\pm}$0.84$mm^2$ at 4 weeks, 8 weeks, 12 weeks respectively, and invasion rate of connective tissue to membrane are 30.7${\pm}$5.1%, 53.3${\pm}$4.4%, 69.5${\pm}$3.1%, respectively. 4. Each fiber of Chitosan membrane was surrounded by connective tissue and showed external resorption pattern. It showed little invasion of inflammatory cells and excellent biocompatability. The resorption rate was relatively slow. Surface area are 6.01${\pm}$2.01$mm^2$, 5.49${\pm}$1.3$mm^2$, 5.06${\pm}$1.38$mm^2$ at 4 weeks, 8 weeks, 12 weeks respectively, and invasion rate of connective tissue to membrane are 31.3${\pm}$3.6%, 38.4${\pm}$3.80%, 39.7${\pm}$5.6%, respectively. Consequently, Para-Dioxanone membrane and Chitosan membrane are found to be clinically effective for their excellent tissue reaction and biocompatibility. Futhermore, the advantage of bone regenerating ability as well as the relatively long resorption period of Chitosan membrane, it might be widely used in implant or ridge augmentation.

머리-목 그리고 어깨의 방사선 치료 시 피부곡면과 고정장치로 인한 피부손상연구 (Skin Damage Sustained During Head-and-Neck and Shoulder Radiotherapy Due to the Curvature of Skin and the Use of Immobilization Mask)

  • 김수길;정태식;임상욱;박영목;박달
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.86-92
    • /
    • 2010
  • 곡면 형태의 피부표면의 방사선량을 방사선크롬 필름과 열형광 선량계를 이용하여 측정하고자 한다. 또한 고정 장치의 사용으로 인한 고에너지 방사선의 피부보존효과의 감쇠를 정량적으로 측정하여 Monte-Carlo 프로그램으로 계산한 값과 비교하고자 한다. 머리-목 그리고 어깨의 곡면 형태를 모의하여 만든 11 cm 직경의 원통 팬텀에 $40{\times}40\;cm^2$의 조사야, SAD 100 cm, 6 MV의 방사선을 쪼였다. 또한 관련된 치료 상황과 유사한 조건으로 만들기 위해 그물망 형태의 고정 마스크를 원통형 팬텀에 씌워서 실험하였다. 원통 팬텀의 원둘레 주위를 따라 $0^{\circ}$에서 $360^{\circ}$까지의 피부선량곡선을 구하였다. 방사선크롬 필름을 이용하여 구한, 정면 입사위치($0^{\circ}$)에서의 피부선량은 최대값 깊이($D_{max}$) 방사선량의 47%, 접선 각도인 $90^{\circ}$에서는 61%로 측정되었다. 1.5 mm의 고정마스크를 씌운 경우 $0^{\circ}$ 입사지점에서는 59%, $80^{\circ}$에서는 78%였다. TLD를 통한 결과는 고정마스크를 씌운 경우 $0^{\circ}$ 입사지점에서는 66%, $80^{\circ}$에서는 80%였고 필름의 경우와 유사한 형태를 보였다. 고정 마스크를 머리-목 그리고 어깨 부위에 부착시켜서 치료를 하는 경우에 접선 부근 각도에서의 피부선량이 치료선량과 거의 같은 값을 보였다. 곡면 부위의 피부에는 고정성을 잃지 않는 범위 안에서 보다 더 얇고 더 구멍이 많이 뚫린 고정마스크를 사용해야 과도한 피부선량을 줄일 수 있을 것으로 사료된다.

Imipramine이 배뇨근 세포의 수축성에 미치는 직접작용 (Effect of Imipramine on the Contractility of Single Cells Isolated from Canine Detrusor)

  • 허찬욱;이광윤;김원준
    • Journal of Yeungnam Medical Science
    • /
    • 제11권2호
    • /
    • pp.293-302
    • /
    • 1994
  • 유뇨증의 치료제로서 널리 사용되고 있는 imipramine의 작용기전에 관한 학설이 여러가지가 있으나 그 중 콜린성수용체 봉쇄작용을 관찰하기 위한 방법으로 평활근 세포를 분리배양하여 단일세포에 대한 acetylcholine의 수축작용과 이에 대한 imipramine의 길항작용을 atropine의 그것과 비교해 보기로 하였다. 개의 방광을 적출하여 $0{\sim}4^{\circ}C$의 K-H 용액내에서 $2{\times}2mm$크기의 평활근 절편을 얻어 $36^{\circ}C$의 collagenase 용액에 넣고 95%/5% $O_2/CO_2$, 혼합산소 공급하에서 17~20분동안 배양하여 분리된 부유세포군을 5 ml test tubes에 나누어 담고 acetylcholine을 $10^{-14}M{\sim}10^{-9}M$의 농도로 첨가하였다. Acrolein 1%를 가하여 수축한 세포를 고정시킨 후, 위상차 현미경에 장착한 CCTV camera로 채취한 영상을 microscaler로 전송하고 monitor상에서 세포의 길이를 측정하였다. 분리된 세포들은 acetylcholine에 의해 5초 이내에 최대 수축을 보였으며 이후 120초까지 수축상태를 지속하였다. Atropine은 acetylcholine 유발 수축을 atropine $10^{-7}M$ 에서부터 농도의존적으로 억제하였으며, imipramine도 acetylcholine 유발수축을 atropine과 같은 경향으로 농도의존적으로 억제하였는데, imipramine $10^{-9}M$의 저농도에서도 유의한 억제를 보였다. 이상의 결과를 종합하면 본 실험에 사용된 조건하에서의 collagense를 이용한 세포 분리법은 단일세포를 대상으로 하는 실험을 위하여 가용한 방법이며, imipramine은 개의 방광평활근 단일세포에서 atropine보다 더 강력한 콜린성 수용체 봉쇄작용을 나타낸다고 생각되었다.

  • PDF

임플란트 나사산 디자인이 변연골 응력에 미치는 영향 (Effect of thread design on the marginal bone stresses around dental implant)

  • 이상현;조광헌;이규복
    • 대한치과보철학회지
    • /
    • 제49권4호
    • /
    • pp.316-323
    • /
    • 2011
  • 연구 목적: 본 연구의 목적은 치과용 임플란트 나사산 디자인이 변연골 응력에 미치는 영향에 정량적인 분석을 하고자 한다. 연구 재료 및 방법: 외경 4.1 mm (경부직경 3.5 mm), 매식부 길이 10 m인 표준형 ITI 임플란트 시스템(ITI Dental Implant System; Straumann AG, Waldenburg, Switzerland)을 기본모델(대조모델)로 채택하고, 그 몸체의 나사산은 다른 임플란트 시스템에 채택되고 있는 삼각형, 사각형, buttres형 디자인을 가지는 가상의 해석모델을 4종 만들었다. 해석모델은 나사산 형태와 크기에 따라 (1) 모델 A (작은 삼각형 나사산), (2) 모델 B (큰 삼각형 나사산), (3) 모델 C (buttres형 나사산), 및 (4) 모델 D (사각형 나사산)로 구분하였다. 유한요소 모델링과 해석에는 NISA II/DISPLAY III (Engineering Mechanics Research Corporation, Troy, MI, USA) 프로그램을 사용하였다. Mesh 구성에는 NKTP type 34형 solid 요소(4각형 축대칭 요소, 요소당 절점수 8개)를 사용하여 임플란트 장축과 평행한 축대칭 하중은 물론 장축과 경사각을 갖는 비축대칭 하중조건을 모두 해석할 수 있도록 하였다. 임플란트의 표면으로부터 각각 0.2, 0.4, 0.6, 0.8, 1.0 mm 떨어진 위치에 5개의 응력관찰점(stress monitoring point)을 설정 하여 기록된 응력 값으로부터 회귀분석을 통하여 변연골 응력 최대값(peak stress)을 정량화하였다. 해석에 사용한 하중 조건은 2가지로, 임플란트 축에 평행한 수직하중 100 N과 임플란트 축과 $30^{\circ}$를 이루는 경사력 100 N 조건이었다. 결과: 임플란트 경부와 접하고 있는 인접 변연골에 응력집중현상이 보이고 있었으며, 그 양상은 임플란트 나사산 디자인과 무관하게 거의 유사하게 관찰되었다. 수직력 100 N 조건에서 산출된 변연골 최대응력값은 대조모델과 실험모델 A, B, C, D에서 7.84, 6.45, 5.96, 6.85, 5.39 MPa이었고, 경사력 조건에서는 각각 29.18, 26.45, 25.12, 27.37, 23.58 MPa이었다. 결론: 임플란트 나사산의 디자인은 변연골의 응력에 영향을 미치는 중요한 요소이다.