• Title/Summary/Keyword: Mesh Pattern

Search Result 218, Processing Time 0.026 seconds

Mathematical Algorithms for the Automatic Generation of Production Data of Free-Form Concrete Panels (비정형 콘크리트 패널의 생산데이터 자동생성을 위한 수학적 알고리즘)

  • Kim, Doyeong;Kim, Sunkuk;Son, Seunghyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.565-575
    • /
    • 2022
  • Thanks to the latest developments in digital architectural technologies, free-form designs that maximize the creativity of architects have rapidly increased. However, there are a lot of difficulties in forming various free-form curved surfaces. In panelizing to produce free forms, the methods of mesh, developable surface, tessellation and subdivision are applied. The process of applying such panelizing methods when producing free-form panels is complex, time-consuming and requires a vast amount of manpower when extracting production data. Therefore, algorithms are needed to quickly and systematically extract production data that are needed for panel production after a free-form building is designed. In this respect, the purpose of this study is to propose mathematical algorithms for the automatic generation of production data of free-form panels in consideration of the building model, performance of production equipment and pattern information. To accomplish this, mathematical algorithms were suggested upon panelizing, and production data for a CNC machine were extracted by mapping as free-form curved surfaces. The study's findings may contribute to improved productivity and reduced cost by realizing the automatic generation of data for production of free-form concrete panels.

Experimental and numerical study on the structural behavior of Multi-Cell Beams reinforced with metallic and non-metallic materials

  • Yousry B.I. Shaheen;Ghada M. Hekal;Ahmed K. Fadel;Ashraf M. Mahmoud
    • Structural Engineering and Mechanics
    • /
    • v.90 no.6
    • /
    • pp.611-633
    • /
    • 2024
  • This study intends to investigate the response of multi-cell (MC) beams to flexural loads in which the primary reinforcement is composed of both metallic and non-metallic materials. "Multi-cell" describes beam sections with multiple longitudinal voids separated by thin webs. Seven reinforced concrete MC beams measuring 300×200×1800 mm were tested under flexural loadings until failure. Two series of beams are formed, depending on the type of main reinforcement that is being used. A control RC beam with no openings and six MC beams are found in these two series. Series one and two are reinforced with metallic and non-metallic main reinforcement, respectively, in order to maintain a constant reinforcement ratio. The first crack, ultimate load, deflection, ductility index, energy absorption, strain characteristics, crack pattern, and failure mode were among the structural parameters of the beams under investigation that were documented. The primary variables that vary are the kind of reinforcing materials that are utilized, as well as the kind and quantity of mesh layers. The outcomes of this study that looked at the experimental and numerical performance of ferrocement reinforced concrete MC beams are presented in this article. Nonlinear finite element analysis (NLFEA) was performed with ANSYS-16.0 software to demonstrate the behavior of composite MC beams with holes. A parametric study is also carried out to investigate the factors, such as opening size, that can most strongly affect the mechanical behavior of the suggested model. The experimental and numerical results obtained demonstrate that the FE simulations generated an acceptable degree of experimental value estimation. It's also important to demonstrate that, when compared to the control beam, the MC beam reinforced with geogrid mesh (MCGB) decreases its strength capacity by a maximum of 73.33%. In contrast, the minimum strength reduction value of 16.71% is observed in the MC beams reinforced with carbon reinforcing bars (MCCR). The findings of the experiments on MC beams with openings demonstrate that the presence of openings has a significant impact on the behavior of the beams, as there is a decrease in both the ultimate load and maximum deflection.

The Aesthetic and Formative Characteristics of Egypt Retro Trends (이집트 복식의 재해석을 통한 미적 특성에 따른 조형적 특성에 관한 연구)

  • Kim, Eun-Sil
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.3
    • /
    • pp.383-395
    • /
    • 2009
  • The purpose of this study was to provide a formative charateristics by analyzing aesthetic charateristics of Egypt costume expressed in contemporary fashion. The result of this study obtained through this process were as follows. Aesthetic characteristics were expressed as a primative-retro characteristics, and a erotic-retro characteristics and a decorative-retro characteristics. Based on these trends, this study analyzed formative charateristics in an aspect of form, color, material, and decoration. In the modern fashion, unlike the H-line silhouette given by a natural fit in the primitive retro, the erotic retro was characterized in the shape by a tight H-line silhouette. For the color, peach, yellow green, gold, light blue, red, and black were used as the main color. For the material, see-through, gauze, mesh, organdy, and tight vinyl were utilized to emphasize an erotic image and expose a body secretly. For the decoration, the characteristic of erotic retro using the simple or same colors frequently was the use of similar accessories colors matched with material colors. The decorative retro was characterized in the shape by a H-line silhouette connected as a part of clothing which applied passium and a greatly modified silhouette from an Egyptian simple style which was well-matched with splendid accessories. For the color, the broadest range of color changes was found from light pastel such as white, yellow, light pink, burnt orange, blue, purple, silver, gold, and red to strong vivid tones. For the material, modern materials such as organdy, tulle, leather, and furs were often used. For the decoration, passium, an eagle pattern, scarab earrings, a crown, a sneak-shaped coronet, and pictograph printed on the fabric were frequently used.

  • PDF

A development of outdoor jackets for active senior males (액티브 시니어 남성을 위한 아웃도어 재킷 개발)

  • Kim, Ji-Eun;Kim, Eun-Kyong
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.20 no.2
    • /
    • pp.31-46
    • /
    • 2018
  • This study was carried out to offer basic data that can be used for outdoor wear production for active senior males, emerging as a new consumer bracket in the era of rapid aging. To this end, this study modified and complemented the patterns of outdoor jackets for active senior males based on existing outdoor jackets that received the most excellent evaluation. On the basis of the research outdoor wear wearing assessment results, this study confirmed those areas to be modified and proposed areas to be considered in manufacturing outdoor wear for this demographic. As a result of existing outdoor wear's wearing assessment, the jacket of brand B was shown to be the most excellent one. This study actually designed research outdoor wear patterns by modifying the problematic parts through the addition and subtraction of spare length or circumference in the sections where fit satisfaction was low by referring to the selected brands' patterns. The research outdoor wear was designed by referring to the preferred outdoor types and colors that were highlighted in the previous survey result of consumer wearing reality, based on the designs of the outdoor wear receiving the most excellent assessment in wearing assessment. Fabric that specially glued two-layered mesh that bonded the thin membrane of synthetic resin with polyester fabric was used as the material in this study. Wearing assessment was conducted by comparing the manufactured research outdoor wear and the existing outdoor wear selected as excellently assessed outdoor wear. Consequently, this study verified that the wearing fit of the research outdoor wear was more excellent in most items. This study proposed final patterns for outdoor jackets suitable for active senior males through the modification of several items that required improvements as per the wearing assessment of the research outdoor wear.

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE PLATFORM SWITCHING

  • Kim Yang-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.727-735
    • /
    • 2005
  • Statement of problem. Platform switching in implant prosthesis has been used for esthetic and biological purpose. But there are few reports for this concept. Purpose. The purpose of this study is evaluation of platform switching in wide implant by three dimensional finite element analysis. Materials and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for Osstem implant system. Three-dimensional finite element models were developed for (1) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with wide cemented abutment, titanium alloy abutment screw, and prosthesis (2) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with regular cemented abutment, titanium alloy abutment screw and prosthesis(platform switching) was made for finite element analysis. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized to 650N, and round and flat type prostheses were loaded to 200 N. Four loading offset point (0, 2, 4, 6 mm from the center of the implants) were evaluated. Models were processed by the software programs HyperMesh and ANSA. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView were used for post processing. Results. The results from experiment were as follows; 1. von Mises stress value is increased in order of bone, abutment, implant and abutment screw. 2. von Mises stress of abutment screw is lower when platform switching. 3. von Mises stress of implant is lower when platform switching until loading offset 4 mm. 4. von Mises stress of abutment is similar between each other. 5. von Mises stress of bone is slightly higher when platform switching. Conclusion. The von Mises stress pattern of implant components is favor when platform switch ing but slightly higher in bone stress distribution than use of wide abutment. The research about stress distribution is essential for investigation of the cortical bone loss.

Computation of Meteorologically-Induced Circulation on the East China Sea using a Fine Grid Three-dimensional Numerical Model (세격자삼차원 수치 모형에 의한 동중국해의 기상학적으로 유발된 해류순환의 산정)

  • Park, Byung-Ho;Suh, Kyung-Suk
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.4 no.1
    • /
    • pp.45-58
    • /
    • 1992
  • A three-dimensional hydrodynamic numerical model is used to compute the annual and seasonal meteorologically-induced residual circulation on the Yellow Sea and the East China Sea continental shelf. The model is formulated having irregular coastal boundaires and non-uniform depth distribution representative of nature. The previous three-dimensional model of the East China Sea (Choi. 19U) has been further refined to resolve the flow over the continental shelf in more detail. The mesh resolution of the present finite difference grid system used is 4 minutes latitude by 5 minutes longitude over the entire shelf. The circulation pattern showing depth and spatial distribution of currents over the Yellow Sea and the East China Sea is presented. Meteorologically-induced currents are subsequently used to compute turn-over times for the three depths (surface. mid-depth. bottom) and the total water column of various regions of the Yellow Sea and the East China Sea.

  • PDF

Noise Control of Plate Structures with Optimal Design of Multiple Piezoelectric Actuators (복수 압전 가진기의 최적 설계를 통한 판구조물의 소음제어)

  • 김재환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.263-270
    • /
    • 1996
  • Noise control of a plate structure with multiple disk shaped piezoelectric actuators is studied. The plate is excited by an acoustic pressure field produced by a noise source located below the plate. Finite element modeling is used for the plate structure that supports a combination of three dimensional solid, flat shell and transition elements. The objective function, in the optimization procedure, is to minimize the sound energy radiated onto a hemispherical surface of given radius and the design parameters are the locations and sizes of the piezoelectric actuators as well as the amplitudes of the voltages applied to them. Automatic mesh generation is addressed as part of the modeling procedure. Numerical results for both resonance and off resonance frequencies show remarkable noise reduction and the optimal locations of the actuators are found to be close to the edges of the plate structure. The optimized result is robust such that when the acoustic pressure pattern is changed, reduction of radiated sound is still maintained. The robustness of an optimally designed structure is also tested by changing the frequency of the noise source using only the actuator voltages as design parameters.

  • PDF

Clinical Evaluation for System Performance of Image Intensifiers (상강화기의 임상평가)

  • Kim, Chang-Seon;Charles R. Wilson
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.143-154
    • /
    • 1998
  • The image intensifier is the key component which determines the imaging characteristics in a fluoroscopic imaging system. A system performance program for clinical evaluation of two image intensifiers, that is simple, non-invasive and time effective, was described. Tests were grouped into three headings: x-ray generator, image quality, and collimation. For the x-ray generator, the kVp accuracy and the automatic exposure control operation were compared. Low- and high-contrast resolution measurements, and mesh pattern study belong to the image quality tests and those tests were performed for the video monitor and photospot images. For the collimation, usable field diameter and image distortion of image intensifiers were measured and quantified. The procedures and the results are hoped to be used for the clinical evaluation of system performance and/or acceptance tests for image intensifiers.

  • PDF

Finite Element Analysis for Temperature Distribution Prediction of Steady Rolling Tires with Detailed Tread Pattern (패턴 형상을 고려한 회전하는 타이어의 온도 예측을 위한 유한 요소 해석)

  • Jeong, Kyoung Moon;Kang, Sung Ju;Park, Woo Cheol;Kim, Hyoung Seok;Kim, Kee Woon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.1
    • /
    • pp.117-125
    • /
    • 2014
  • The temperature distribution of steady state rolling tires with detailed tread blocks is numerically predicted using the three dimensional full patterned tire model. A three dimensional periodic patterned tire model is constructed by copying 1-sector mesh in the circumferential direction. Using the static tire contact analysis, the strain cycles during one revolution are approximated with the strains at Guassian points of the elements which are sector-wise repeated within the same circular ring of elements, by neglecting the tire rolling effect. Based upon the multi-axial fatigue theory, the maximum principal strain is used to represent the combined effect of six strain components on the hysteretic loss. In the following, the deformation due to the inflation and vertical load is calculated using ABAQUS. Then heat generation rate in each element is calculated using an in-house code. Lastly, temperature distribution is calculated using ABAQUS again. Through the numerical experiments, the validity of the proposed prediction method is examined by comparing with the experiment and the temperature distribution of a patterned tire model is compared with those of the main-grooved simple tire model.

Development and Evaluation of an Oral Controlled Release Delivery System for Melatonin

  • Lee, Beom-Jin;Parrott, Keith A.;Sack, Robert L.;Ayres, James W.
    • Journal of Pharmaceutical Investigation
    • /
    • v.23 no.3
    • /
    • pp.9-18
    • /
    • 1993
  • Sugar spheres loaded with melatonin (MT) were coated with $Aquacoat^{\circledR}$ to control the release rate of MT over 8 hours. A zero-order release pattern over 8 hours was obtained with 20% coating on 8-10 mesh beads in USP basket dissolution studies. MT in 20% coated beads was quite stable at room temperature with less than 5% MT degraded during 6 months' storage. Dissolution profiles were also unchanged after 6 months. An oral preparation containing MT-loaded uncoated beads for immediate release and 20% coated beads with $Aquacoat^{\circledR}$ for controlled release over 8 hours was evaluated in six human subjects. When total 0.5 mg MT as low dose (immediate release portion of MT, 0.1 mg) was administered to four subjects, average peak plasma MT concentration was reached at about 600 pg/ml and maintained at about 10 pg/ml over 8 hours. Plasma MT concentration-time profiles were similar in shape to computer-simulated profiles. However, maximal plasma MT concentrations were three times greater compared to computer simulated curve. These results suggest that MT dose, ratio of immediate and controlled release MT, and pharmacokinetic parameters selected are adjusted to mimic endogenous MT concentration-time curve. In another study, 0.2 mg MT having 10% of immediate release portion and 80% controlled release portion produced plasma MT concentration-time curve which is more similar to endogenous profiles. A low bioavailability (<20%) may result from extensive first pass metabolism and remaining amounts of MT from controlled beads. A good correlation between plasma MT concentration and urinary excretion rate of 6-sulphatoxymelatonin (6-STMT), a major metabolite of MT was observed. As plasma MT concentration increased, urinary excretion rate of 6-STMT increased concomitantly. The linear relation between plasma MT and urinary excretion rate of 6-STMT was statistically significant. This result suggests that urinary 6-STMT may be used as an index of circadian rhythms of MT in humans.

  • PDF