• Title/Summary/Keyword: Mercury Lamp

Search Result 149, Processing Time 0.029 seconds

Scanning Backlight Driver for Mercury Free Flat Fluorescent Lamp (무수은 면광원 램프용 Scanning Backlight 구동회로)

  • Oh, Eun-Tae;Jung, Yong-Min;Lee, Kyung-In;Yoo, Ho-Won;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.8-14
    • /
    • 2009
  • A lamp which is currently employed to LCD(Liquid Crystal Display) Backlight is almost CCFL(Cold Cathod Fluorescent Lamp) and EEFL(External Electrode Fluorescent Lamp). However, the use of these lamps is being restricted as RoHS(the Restriction of the use of certain Hazardous Substances in electrical and electronic equipment) regulation is gradually reinforced. According to this situation, the manufacturing of a lamp which doesn't use mercury is unescapable. Moreover, LCD TV has a defect which take place Motion Blur phenomenon due to response time of LC(Liquid Crystal), and Hold-type characteristic which only exists in LCD differently to CRT, PDP. In this paper, an inverter is proposed to drive a plane light source lamp which is not containing mercury. Driving circuit of proposed inverter is simple because the number of semiconductor device and magnetic device is reduced by using forward topology. Also, Motion Blur phenomenon is decreased by dividing the plane light source lamp to six block along vertical direction, and scanning. Finally, we proved usefulness of proposed inverter through experiment.

A Study of Field Survey on Working Environment for Mercury Treatment Establishments in Korea (전국 수은 취급사업장의 작업환경 실태 조사 연구)

  • 엄성인;백존배;이영섭
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.3
    • /
    • pp.30-34
    • /
    • 1992
  • This study is conducted to evaluate the airborne concentration of mercury, as well as installation and efficiency of local exhaust ventilation system for 57 factories manufactured fluorescence lamps, mercury lamps and thermometers for July and August 1990. Results and conclusion are as fellows : 1) Mercury treatment factories are 32 among 57 ones, which are 18 fluorescence lamp manufacturing ones and 6 mercury lamp ones and 3 thermometer ones and 5 other ones. 2) Mean airborne concentrations of mercury for factories manufactured mercury lamps are 0.01 mg/ ㎥ in injection process and 0.0155mg/㎥ in exhaust process, and mean airborne concentration of mercury for factories manufactured thermometer are 0.023mg/㎥ in injection process and 0.012mg/㎥ in selection process. All of these airborne concentrations of mercury are lower than PEL(Permissible Exposure Limit ), 0.05mg/㎥. 3) Mean airborne concentrations of mercury for factories manufactured fluorescence lamps are 0.094mg/㎥ in injection process and 0.087mg/㎥ in exhaust process, and 0.052mg/㎥ in sealing process and 0.085mg/㎥ in other process, respectively. All of these air borne concentrations of mercury are exceeded to PEL. More than 60% among 32 factories manufactured mercury are exceeded to PEL. 4) Nine factories among 18 factories manufactured fluorestence lamps are equipped with local exhaust ventilation system, and 7 factories among 9 factories are required for the improvement of suction capacity and structure. Five factories among 14 factories manufactured mercury lamps and the other ones are equipped with local exhaust ventilation system, and 2 factories are required for the improvement of suction capacity and structure.

  • PDF

A Study on the Effect of Improvement in Work Environment and of Segregation in a Fluorescent Lamp Manufacturing Factory (모 수은취급사업장의 작업환경 개선 및 근로자 작업전환 효과에 관한 연구)

  • Chang, Soung-Hoon;Kim, Kwang-Jong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.4 s.28
    • /
    • pp.474-479
    • /
    • 1989
  • This research was conducted to evaluate the effect of improvement in work environment and of segregation in a fluorescent lamp manufacturing factory. Among the total of 80 workers, 8 workers whose mercury concentration in urine reached a hazardous level ($200-299{\mu}g/l$) were moved to mercury free workplace. The follow-up examination for their mercury concentration in urine was done three times ; on May 3, 1988, September 1, 1988 and April 3, 1989. The results were as follows : 1. Mercury concentration in the air was reduced from 0.140 to 0.107 $mg/m^3$ in 4 months, and to $0.087mg/m^3$ in one year after environmental improvement in workplace. However the level still exceeded the Threshold Limit Value. 2. The geometric mean of urinary mercury concentration among 80 workers was $173.0{\mu}g/l\;(5.1{\sim}458.6{\mu}g/l$). The distribution of workers according to urinary mercury concentration showed that 9 workers (11.2%) were above the mercury poisoning level ($300{\mu}g/l$), 24 workers (30.0%) were $200-299{\mu}g/l$, 35 workers (43.8%) were $50-199{\mu}g/l$, and 12 workers (15.0%) were below 50 ${\mu}g/l$. 3. Among the 24 workers whose urinary mercury concentration was 200-299 $50-199{\mu}g/l$, 8 were able to be followed up. Their mean urinary mercury concentration before segregation was $244.9{\mu}g/l$, but decreased to $151.4{\mu}g/l$ in four months, $128.8{\mu}g/l$ in six months, and $46.8{\mu}g/l$ in one year after segregation.

  • PDF

Incoherent Triangular holography using Mercury Lamp (수은등을 이용한 인코히어런트 삼각 홀로그래피)

  • 김수길
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.144-148
    • /
    • 2000
  • We presented a modified triangular interferometer as an incoherent holography, which can eliminate bias and conjugate image problems of the conventional one. Also, to demonstrate the feasibility of incoherent holography, the formation of an incoherent hologram using a mercury lamp and its optical reconstruction were presented.

  • PDF

Plasma Diagnosis of Ne:Xe, Ne:Ar Mixed Gases by Single Langmuir Probe in Inductively Coupled Plasma Light Source System (ICP 광원 시스템의 Ne:Xe, Ne:Ar 혼합가스의 단일탐침법을 이용한 플라즈마 진단)

  • Choi, Yong-Sung;Lee, Woo-Ki;Moon, Jong-Dae;Lee, Kyung-Sup;Lee, Sang-Heon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.91-95
    • /
    • 2006
  • In whole world consciousness of environment maintenance have increased very quickly for the end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mechanism is the worst environmental problem. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe mixing gas lamp improvements firing voltage of Xe gas lamp. Purpose and subject of this study are understand, efficiency, ideal of Ne:Xe plasma which mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by Langmuir probe data. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe.

  • PDF

Discharge Characteristics of Xe Plasma Flat Lamp for LCD Backlight According to Operating Voltage Pulse (LCD 백라이트용 Xe계 플라즈마 평판 램프의 구동 전압 Pulse의 조건에 따른 방전 특성 연구)

  • Kwon, Eun-Mi;Kim, Hyuk-Hwan;Lee, Won-Jong
    • Korean Journal of Materials Research
    • /
    • v.13 no.4
    • /
    • pp.271-278
    • /
    • 2003
  • Conventional backlight for liquid crystal display (LCD) uses mercury which leads to environmental pollution. In this study, characteristics of AC coplanar type mercury-free plasma flat lamp have been studied. Pollution-free Xe-He is adopted as a discharge gas system. Since the Xe gas has a lower efficiency in generating vacuum ultraviolet (VUV) than mercury, the improvement of luminance and luminous efficiency in the Xe gas system is very important. The electrode, dielectric, and phosphor layers constituting lamp are formed on the bottom glass by the screen printing method. The effects of pulse shape, on-time, and pulse frequency on the luminance and luminous efficiency have been examined. For Xe(5%)-He gas, the lamp exhibits higher efficiency with sharper pulse shape, higher peak voltage, and shorter pulse on-time (up to 2 $\mu\textrm{s}$). Higher efficiency and lower consumption of power were obtained at 30 kHz than at 60 kHz. The collision of ion to bottom electrodes is a dominant factor to raise the lamp temperature. Therefore the high voltage and low current discharge system is necessary for reduction of the lamp temperature as well as for enhancement of the luminous efficiency.

On the Photoelectric Effects of the Various Kinds of Light Source influencing to the Starting Characteristics of the Cold Cathode Type Discharge Tube (냉음극방전관의 기동특성에 미치는 각종광원에 의한 광전효과)

  • Chee, Chol Kon;Won, Chong Soo
    • 전기의세계
    • /
    • v.13 no.4
    • /
    • pp.10-15
    • /
    • 1964
  • It is well known that the starting characteristics of the cold cathode type discharge tube have photoelectric effects by the incident light from outside. After making the cold cathode type discharge tubes to be avaiable for popularizing, the present paper was devoted primaliry to a study of relations between the starting characterstics and photoelectric effects of discharge tube under the oight circumstances of day light, incandescent lamp, flouresent lamp, and mercury lamp we used frequently. The result of this investigation show that the photoelectric effects by flourescent lamp emitting short wave length having close ralation to the photoelectric effects is greater than incandescent lamp or day light, and also mercury lamp emitting shorter wave length than flourescent lamp indicates the greatest photoelectric effects.

  • PDF

A study on the temperature distribution measurement of the high pressure mercury lamp (고압 수은등의 온도분포 측정에 대한 연구)

  • 손승현;김상용;김창섭;지철근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.35-40
    • /
    • 1990
  • Temperature distribution of high pressure mercury lamp has been mesured as a function of time using spectroscopic method. Sampling signal which is synchronized by lamp voltage was used to mesure temporal line intensity at each radius. To obtain radial temprature distribution, the mesured intensity was transformed into radial line intensity by Abel's formula. Absolute temperature profile was calculater from relative intensities of spectral lines as a function of line and tube radius. The temperature profile is very similar to the electrical tube current profile.

  • PDF

Dependence of Round Type Electrodeless Lamp according to Ferrite Core and Cold Spot Temperature (둥근형 무전극 램프의 페라이트 코어와 냉점의 온도 의존성)

  • Jang, Hyeok-Jin;Yang, Jong-Kyung;Kim, Nam-Goon;Jung, Young-Il;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1078-1083
    • /
    • 2009
  • Generally Lighting system consists of lamp and luminaire. When a fluorescent lamp is installed in luminaire, power and light output is changed by ambient temperature. Particularly electrodeless lamp depends on the changes that are mercury pressure with amalgam temperature and magnetic properties with ferrite temperature. It has finally influence on optical efficiency. In this study, the temperature change of ferrite and cold spot, vessel are measured at transitional state and then same characteristics are measured with increase of ambient temperature. At transitional state, luminous flux is related to temperature change of cold spot that compare with behavior of mercury pressure and light output. At increase of ambient temperature, we analyzed change that efficiency and electrical, optical characteristics of elecrodeless lamp are related to ferrite core and cold spot temperature.

The Electron Temperature and Density Properties of Mixed Gases in ICP Lighting System : (Ne:Xe, Ne:Ar) (ICP 광원 시스템의 Ne:Xe 및 Ne:Ar 혼합가스의 전자온도 및 전자밀도 특성)

  • Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee;Choi, Gi-Seung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.3
    • /
    • pp.156-160
    • /
    • 2006
  • In whole world consciousness of environment maintenance have increased very quickly for the end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem and root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe and Ne:Ar mixed gas lamp improve firing voltage of Xe gas lamp. Purpose of this study is to understand ideal mixing-ratio of Ne:Xe and Ne:Ar gas by electron temperature and electron density for mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by single-Langmuir probe. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe and Ne:Ar.