• 제목/요약/키워드: Meniscus Guide

검색결과 8건 처리시간 0.021초

슬롯 다이 코팅을 이용한 유기 박막 코팅 폭 제어 및 연속 코팅 공정 개발 (Control of Coating Width and Development of Continuous Coating Process for Organic Thin Films Using Slot-die Coating )

  • 김기은;김영신;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제23권3호
    • /
    • pp.69-75
    • /
    • 2024
  • For potential applications in large-area organic light-emitting diode (OLED) displays, solar cells, sensors, and secondary batteries, we have developed a slot-die coating process that allows control of coating width and continuous coating. In a sheet-to-sheet (S2S) type coating system, coating width adjustment and continuous coating processing are highly demanded to improve productivity and automate the coating process. To control coating width, we have proposed a shim plate with a narrower outlet width and a dual plate slot-die head (DP-SDH) with a meniscus guide. For continuous coating process, we have attempted a lip dipping method and a motorized cleaning module method. Finally, using the DP-SDH and motorized cleaning module method, we have successfully fabricated a poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) film with a width of 150 mm, despite the head-lip width being 200 mm.

  • PDF

무릎 수술 후 재활 치료에서의 한양방협진 매뉴얼 제안 (Proposal of East-West Integrative Medicine Manual for Rehabilitation after Knee Surgery)

  • 송민영;조희근;설재욱;임정태
    • 한방재활의학과학회지
    • /
    • 제28권1호
    • /
    • pp.97-107
    • /
    • 2018
  • Objectives This is one of the manuals of East-West integrative medicine which was created by the committee on integrative medicine of Chung-Yeon Korean Medicine Hospital. The purpose of this manual is to support clinical decision-making and communication between Korean and western medical staff in a Korean medicine hospital during the rehabilitation of patients after knee surgery. Methods The draft was made by two rehabilitation specialists in Korean medicine. After a rehabilitation specialist in western medicine reviewed the draft and exchanged their ideas, a revised version that reflects the goal of consultation was made. Then the committee agreed to adopt the manuals through the process of review and feedback in addition to face-to-face discussions. Results This manual describes clinical decision-making for rehabilitation after arthroscopic partial meniscus resection, meniscus refixation, reconstruction of anterior and posterior cruciate ligaments. Therefore, it contains the schedule of rehabilitation treatment by the surgical technique, general goal of the rehabilitation by phase, guide for patients and postoperative infection management. Conclusions Despite some limitations, this manual has significance as the first example of a decision-making protocol suggestion for East-West integrative rehabilitation treatment after a knee surgery in one medical institution.

미세 스트라이프 코팅에 미치는 슬롯 다이 헤드 마이크로 팁 길이의 영향 (Effect of the Microtip Length in a Slot-die Head on Fine Stripe Coatings)

  • 이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제18권4호
    • /
    • pp.69-74
    • /
    • 2019
  • The aim of this work is to investigate the effect of the microtip length in a slot-die head on coating of a fine poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS) stripe. To this end, we have employed a meniscus guide with a 150-㎛-wide microtip and performed roll-to-roll slot-die coatings by varying its length between 500 ㎛ and 50 ㎛. When the microtip length is 150 ㎛ or shorter, we have observed three unexpected phenomena; 1) though the solution spreads much wider than the microtip width, yet the coated stripe width is almost the same as the microtip width, 2) the stripe width decreases, but the stripe thickness is rather increased with increasing coating speed at a fixed flow rate, 3) we obtain stripes much narrower than the microtip width at high coating speeds. It is due to the fact that 1) the meniscus is not well controlled by a short microtip, 2) the main stream of solution from the outlet is very close to the substrate and thus the distributed solution along the head lip merges with the main stream, and 3) the solution is not spread over the entire microtip end at high coating speeds, causing a tiny wobble in the meniscus. Using the 150-㎛-wide and 250-㎛-long microtip, we have fabricated 153-㎛-wide and 94-nm-thick PEDOT:PSS stripe at the maximum coating speed of 13 mm/s. To demonstrate its applicability in solution-processable organic light-emitting diodes (OLEDs), we have also fabricated an OLED device with the fine PEDOT:PSS stripe and obtained strong light emission from it.

내측 반월상 연골 후각의 후방 경골 부착부위의 절단 파열 - 임상 양상 및 새로운 봉합 수기(pullout suture) - (Transection of the posterior horn of the medial meniscus at the posterior tibial attachment - Clinical features and A new repair technique (Pullout suture) -)

  • 안진환;하철원;김호;김성민
    • 대한관절경학회지
    • /
    • 제3권2호
    • /
    • pp.109-114
    • /
    • 1999
  • 목 적 : 내측 반월상 연골후각의 후방 경골 부착부위의 절단 파열은 흔하지 않고 기존의 수기로는 봉합이 어렵다. 이에 저자들은 내측 반월상 연골의 후방 경골 부착부위의 절단 파열의 임상 양상 및 pullout suture를 통한 새로운 봉합술을 소개하고자 한다. 대상 및 방법 : 년 9월부터 1999년 7월까지 9명의 환자에서 후방 경골 부착부위의 절단 파열을 경험 하였다. 평균 나이는 59.3세로 38세에서 70세까지의 분포였다. 전예에서 자기공명영상과 임상양상으로 진단하였고, 슬관절경을 통해서 확진과 치료를 하였다. 1예에서 2차적 관절경을 시행하여 봉합 된 반월상 연골의 치유여부를 확인하였다. 임상 양상 : 대개 중년이후의 나이에서 호발하며, 특별한 외상의 과거력이 없다. 슬관절 후면의 통증을 호소하였으나, 그 위치가 불명확한 특징이 있었다. 경도내지 중등도의 슬관절의 종창을 호소하였으며, 특징적으로 슬관절을 굴곡 시킬수록 심해지는 술관절 후면의 통증으로 완전한 굴곡의 장애가 있었다. 단순 방사선 사진에서 퇴행성 변화는 없거나, 나이에 비해서 미미한 양상이었다. 술 전 자기 공명영상이 진단에 있어서 매우 중요한 역할을 하며, 특히 관상면에서 반월상 연골의 후각이 후방 경골 부착부위에서 분리되어 있는 형태를 보인다. 수술 수기 : 4개의 표준 portal 로 도달하여 후각부의 절단파열을 확인하고, 변연절제술로 시야를 확보하고 후각의 후방 부착부위의 연골하골을 노출 시킨다. 전내측 또는 후내측 도달법으로 절단단율 PDS 로 봉합한다. PDS 봉합사를 전내측 도달법으로 밖으로 꺼내 놓는다. 경골 내측 근위부에 종절개를 가한 후에 ACL tibla guide를 이용하여 경골 내측 근위부에서 후각의 후방 경골부착부위까지 골 터널을 만든다. 강선 루프를 경골 터널을 통하여 삽입하여서 전내측 도달법으로 빼내고, PDS 봉합사를 사이에 끼워서 다시 경골 터널을 통해 아래쪽으로 당겨서 끌어낸다. PDS 봉합사를 경골 내측 근위부에 post-tie 방법으로 고정한다. 결 론 : 내측 반월상연골 후각의 후방 경골부착부위의 절단피열은 임상적으로 흔하지 않고 보고도 드물다. 임상 양상과 자기공명영상이 진단에 있어서 중요한 역할을 한다. 관절경적 pullout 봉합이 이런 형태의 파열에 대한 치료로서 유용할 수 있을 것으로 사료된다.

  • PDF

정상견 무릎의 관절경 검사소견 (Arthroscopic Findings of the Canine Stifle Joint)

  • 정순욱;정월순
    • 한국임상수의학회지
    • /
    • 제16권2호
    • /
    • pp.300-308
    • /
    • 1999
  • Arthroscopy is a valuable diagnostic and operative tool in equine and human orthopedics. The arthroscope is a difficult instrument to use and requires patience, practice, and persistence in order to obtain good results. This technique was found to be less traumatic than arthrotomy, invasiveness, rapid recovery and the feasibility of surgically correcting many arthropathies. The use of the arthroscope in the dog provides a new dimension in the study and diagnosis of joint derangements. The purpose of this report is to introduce the use of the arthroscope in the dog-more specifically, in the stifle of the dog. A diameter 2.7 mm fore-oblique viewing arthroscope, cold light source, video and video printer are used. With the fore-oblique viewing type it is possible to view directly as well as slightly to the side and the range of viewing can be increased by rotating the arthroscope around the object The scope is connected with a cold light source by means of a fiber-optic light guide. The stifle joint was flexed to 20~30$^{\circ}$. The joint were lavaged with lactated Ringer's solution during arthroscopic examination. Arthroscopy of the stifle was performed prior to arthrotomy in 1 dead dog and 4 healthy dogs, and other 3 dogs was performed only arthroscopic examination. In this study only the conventional approaches were used and in most cases it was possible to view all the intra-articular structures via the lateral infrapatellar approach. In the stifle joint, endoscopic observation was performed to find lateral femoral condyle, patella, medial femoral condyle, trochlear groove, tibia, fat, cranial cruciate ligament, caudal cruciate ligament lateral meniscus, tendon of long digital extensor muscle, medial meniscus, and medial collateral ligament Post-arthroscopic examination, the lameness had disappeared within 12~24 hours. Pain and swelling in the stifle joint had disappeared within 24~36 hours. Post-arthroscopic secondary infection was never encountered in the dogs. In conclusion, arthroscopic insertion technique in canine stifle joint using a diameter 2.7 mm 30$^{\circ}$ arthroscope was established and arthroscopical views of all anatomical structures in the normal stilfe joint were obtained through lateral infrapatellar portal.

  • PDF

슬롯 다이 코팅과 Thermal Reflow방법을 이용한 Cylindrical 마이크로렌즈 제조 (Fabrication of Cylindrical Microlens Using Slot-die Coating and Thermal Reflow Method)

  • 이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제19권3호
    • /
    • pp.30-35
    • /
    • 2020
  • A microlens has been fabricated by various methods such as a thermal reflow, hot embossing, diamond milling, etc. However, these methods require a relatively complex process to control the microlens shape. In this work, we report on a simple and cost-effective method to fabricate a cylindrical microlens (CML), which can diffuse light widely. We have employed a slot-die head with the dual plate (a meniscus guide with a protruded μ-tip and a shim with a slit channel) for coating of a narrow stripe using poly(methyl methacrylate) (PMMA). We have shown that the higher the coating gap, the lower the maximum coating speed, which causes an increase in the stripe width and thickness. The coated PMMA stripe has the concave shape. To make it in the shape of a convex microlens, we have applied the thermal reflow method. When the stripe thickness is small, however, its effect is negligible. To increase the stripe thickness, we have increased the number of repeated coating. With this scheme, we have fabricated the CML with the width of 223 ㎛ and the thickness of 7.3 ㎛. Finally, we have demonstrated experimentally that the CML can diffuse light widely, a feature demanded for light extraction efficiency of organic light-emitting diodes (OLEDs) and suppression of moiré patterns in displays.

소수성 마이크로 패턴을 갖는 Stripe 코팅용 슬롯 다이 헤드 구조 최적화 (Structure Optimization of a Slot-Die Head with a Hydrophobic Micro-Patterns for Stripe Coatings)

  • 유수호;이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제18권2호
    • /
    • pp.6-10
    • /
    • 2019
  • In the presence of $\mu-tip$ for narrow stripe coating, there appears lateral capillary flow along the hydrophilic head lip because the $\mu-tip$ has some resistance to flow. It was known to be suppressed by increasing the contact angle of the head lip. In this paper, we have demonstrated by computational fluid dynamics(CFD) simulations that it can also be suppressed by the formation of micro-patterns on the shim and meniscus guide embedded into the slot-die head. To optimize the micro-patterned structure, we have performed simulations by varying the groove width, depth, and clearance. In the absence of micro-patterns, it is shown by experiment and simulation that the solution spreads to a distance of $1,300{\mu}m$ from the ${\mu}-tip$. In the presence of micro-patterns with the groove width and clearance of $50{\mu}m$, the distance the solution spreads is reduced to $260{\mu}m$. However, no further suppression in the capillary flow is observed with micro-patterns with the groove width of $40{\mu}m$ or less. It is also observed that the capillary flow is not affected by the groove depth if it is larger than $10{\mu}m$. We have shown that the distance the solution spreads can be reduced further to $204{\mu}m$ by coating a hydrophobic material (contact angle of $104^{\circ}$) on the surface of micro-patterns having the groove width and clearance of $50{\mu}m$.

Stripe 코팅용 슬롯 다이 헤드 모세관 유동 전산모사 (Simulation of Capillary Flow Along a Slot-die Head for Stripe Coatings)

  • 유수호;이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제18권1호
    • /
    • pp.92-96
    • /
    • 2019
  • In the presence of ${\mu}-tip$ embedded in a slot-die head for stripe coatings, there arises the capillary flow that limits an increase of the stripe density, which is required for the potential applications in organic light-emitting diode displays. With an attempt to suppress it, we have employed a computational fluid dynamics software and performed simulations by varying the ${\mu}-tip$ length and the contact angles of the head lip and ${\mu}-tip$. We have first demonstrated that such a capillary flow phenomenon (a spread of solution along the head lip) observed experimentally can be reproduced by the computational fluid dynamics software. Through simulations, we have found that stronger capillary flow is observed in the hydrophilic head lip with a smaller contact angle and it is suppressed effectively as the contact angle increases. When the contact angle of the head lip increases from $16^{\circ}$ to $130^{\circ}$, the distance a solution can reach decreases sharply from $256{\mu}m$ to $44{\mu}m$. With increasing contact angle of the ${\mu}-tip$, however, the solution flow along the ${\mu}-tip$ is disturbed and thus the capillary flow phenomenon becomes more severe. If the ${\mu}-tip$ is long, the capillary flow also appears strong due to an increase of flow resistance (electronic-hydraulic analogy). It can be suppressed by reducing the ${\mu}-tip$ length, but not as effectively as reducing the contact angle of the head lip.