• 제목/요약/키워드: Membrane permeability

검색결과 930건 처리시간 0.023초

랫트의 신장 근위곡세뇨관 현탁액을 이용한 Cephaloridine의 신장독성 평가 (Nephrotoxicity Assessment of Cephaloridine using Rat Renal Proximal Tubule Suspension)

  • 홍충만;장동덕;신동환;최진영;조재천;이문한
    • Toxicological Research
    • /
    • 제11권1호
    • /
    • pp.103-108
    • /
    • 1995
  • Rat renal proximal tubule suspension was prepared from adult male Sprague Dawley rat (250-300g) by mechanical (non-enzymatical) method and evaluated as a pontential model for mechanistic studies and early screening of nephrotoxicity, using anionic antibiotics (cephaloridine). Cephaloridine (CPL) produced an increase in LDH release into media. This release results from decrease a proximal tubule cell viability and subsequently increase the permeability of cell viability and subsequently increase the permeability of cell membrane. Since loss of intracellular potassium and ATP into media is the sign of disruption of cell membrane, especially basolateral membrane (BLM), CPL induced proximal tubule cell compromise also appear be associated with BLM, maybe $Na^+-K^+$ ATPase. Also seen was significant depression in brush border membrane (BBM) ALP activity and no significantly increase in BBM GGT activities. The inhibition of typical anion, PAH accumulation (especially, CPL 5 mM) and cation, TEA (especially, 4hours incubation) were seen dose dependently. This is because of CPL accumulation in renal proximal tubule and increase of cytotoxicity.

  • PDF

Kanendomycin이 토끼 적혈구막의 포타슘 투과에 미치는 영향 (The Effects of Kanendomycin on the Potassium Permeability of the Rabbit Erythrocyte Membrane)

  • 김정한
    • The Korean Journal of Physiology
    • /
    • 제8권1호
    • /
    • pp.45-53
    • /
    • 1974
  • The effects of kanendomycin on the potassium permeability in the rabbit erythrocyte membrane are investigated and the results are summarized as follows. 1. Kanendomycin causes the efflux of $K^+\;and\;influx\;of\;Na^+$ across the rabbit erythrocyte membrane. 2. Osmotic resistance of kanendomycin treated erythrocytes is diminished. This diminution of osmotic resistance is more pronounced by increasing concentration of kanendomycin and longer incubation time. But osmotic resistance is rather increased in the presence of lower concentration of kanendomycin. 3. Cysteine and glutathione have little influence on $K^+$ efflux induced by kanendomycin. 4. EDTA has no effect on the increase in $K^+$ outflux by kanendomycin while PCMB augments slightly on $K^+$ outflux. 5. Kanendomycin inhibits $Ca^{++}$ binding competitively to rabbit erythrocyte membrane fragments.

  • PDF

Polydimethylsiloxane 가공 Polypropylene막에서의 기체투과 및 혈액적합성 (Gas Permeability and Blood Compatibility in Polydimethylsiloxane Polypropylene Combined Membrane)

  • 김기범;이삼철;정경락
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.233-234
    • /
    • 1998
  • The purpose of this paper is the evaluation of a permeability and blood compatibility for silicone/polypropylene combined membrane. Despite the overall good performances of polypropylene membrane, its long-lasting usage for artificial lung has been limited by serum leakage. In order to overcome this problem, we have newly fabricated polydimethylsiloxane(silicone)/polypropylene combined membrane(SPCM). SPCM has been proved to be serum leakage free in hours experimental. It has shown good long-lasting gas transfer and durability features.

  • PDF

DME 생산공정에서 복합막을 이용한 이산화탄소 제거공정 전산모사 (A Study on Carbon Dioxide Removal Process Using Composite Membrane in DME Production Process)

  • 노상균
    • 한국산학기술학회논문지
    • /
    • 제15권7호
    • /
    • pp.4698-4706
    • /
    • 2014
  • 본 연구에서는 디메틸에테르(dimethyl ether) 생산 공정에 포함된 이산화탄소 제거공정에서 이산화탄소 제거 방법으로 복합막(composite membrane)을 사용하는 공정에 대해 공정구성과 모사를 수행하였다. 복합막은 (주)에어레인에서 제조한 PEI-PDMS(polyetherimide-polydimethyl siloxane) 복합막을 대상으로 하였으며 복합막 공정을 모델링하기 위해서 상용성 화학공정 모사기인 Invensys 사의 PRO/II with PROVISION 9.2를 사용하였다. 그리고 복합막 공정을 모사하기 위해 필요한 각 순수성분들의 투과도 상수는 (주)에어레인에서 수행한 실험 데이터를 회귀분석 하여 새롭게 결정 하였다. 결국 실험을 통해 얻은 투과도 상수와 상용성 화학공정 모사기를 활용하여 이산화탄소를 제거하기 위한 복합막 공정을 구성하고 제거에 필요한 분리막 면적과 Utility 비용을 도출하였다.

Fundamental parameters of nanoporous filtration membranes

  • Wei Li;Xiaoxu Huang;Yongbin Zhang
    • Membrane and Water Treatment
    • /
    • 제14권3호
    • /
    • pp.115-120
    • /
    • 2023
  • The design theory for nanoporous filtration membranes needs to be established. The present study shows that the performance and technical advancement of nanoporous filtration membranes are determined by the fundamental parameter I (in the unit Watt1/2) which is formulated as a function of the shear strength of the liquid-pore wall interface, the radius of the filtration pore, the membrane thickness, and the bulk dynamic viscosity of the flowing liquid. This parameter determines the critical power loss on a single filtration pore for initiating the wall slippage, which is important for the flux of the membrane. It also relates the membrane permeability to the power cost by the filtration pore. It is shown that for biological cellular membranes its values are on the scale 1.0E-8Watt1/2, for mono-layer graphene membranes its values are on the scale 1.0E-9Watt1/2, and for nanoporous membranes made of silica, silicon nitride or silicon carbonized its values are on the scale 1.0E-5Watt1/2. The scale of the value of this parameter directly measures the level of the performance of a nanoporous filtration membrane. The carbon nanotube membrane has the similar performance with biological cellular membranes, as it also has the value of I on the scale 1.0E-8Watt1/2.

Fisetin-Mediated Perturbations of Membrane Permeability and Intracellular pH in Candida albicans

  • Younhee Kim
    • Journal of Microbiology and Biotechnology
    • /
    • 제34권4호
    • /
    • pp.783-794
    • /
    • 2024
  • The antifungal activity of fisetin against Candida albicans is explored, elucidating a mechanism centered on membrane permeabilization and ensuing disruption of pH homeostasis. The Minimum Inhibitory Concentration (MIC) of fisetin, indicative of its interaction with the fungal membrane, increases in the presence of ergosterol. Hoechst 33342 and propidium-iodide staining reveal substantial propidium-iodide accumulation in fisetin-treated C. albicans cells at their MIC, with crystal violet uptake assays confirming fisetin-induced membrane permeabilization. Leakage analysis demonstrates a significant release of DNA and proteins in fisetin-treated cells compared to controls, underscoring the antifungal effect through membrane disruption. Green fluorescence, evident in both the cytoplasm and vacuoles of fisetin-treated cells under BCECF, AM staining, stands in contrast to controls where only acidic vacuoles exhibit staining. Ratiometric pH measurements using BCECF, AM reveal a noteworthy reduction in intracellular pH in fisetin-treated cells, emphasizing its impact on pH homeostasis. DiBAC4(3) uptake assays demonstrate membrane hyperpolarization in fisetintreated cells, suggesting potential disruptions in ion flux and cellular homeostasis. These results provide comprehensive insights into the antifungal mechanisms of fisetin, positioning it as a promising therapeutic agent against Candida infections.

PEMFC 고분자 막의 전기화학적 열화과정에서 OCV 감소 및 회복 거동을 통한 비가역적 열화 연구 (A Study on Irreversible Degradation through OCV Reduction and Recovery Behavior in the Electrochemical Degradation Process of PEMFC Polymer Membrane)

  • 유동근;박권필
    • Korean Chemical Engineering Research
    • /
    • 제60권2호
    • /
    • pp.217-222
    • /
    • 2022
  • 고분자 전해질 연료전지(PEMFC) 고분자 막의 전기화학적 내구성을 가속적으로 평가하는 개회로 전위 유지(OCV holding) 과정에서 OCV 변화 거동을 해석하는 것은 매우 중요하다. 본 연구에서는 내구성이 각기 다른 세 종류의 MEA(membrane electrode assembly)의 실험데이터를 이용한 실험식을 만들어 비교 및 검토하였다. 막 내부에 라디칼 제거제가 없는 강화막 MEA의 내구 평가시간은 383 h, 막 내부에 라디칼 제거제가 있는 강화막 MEA의 내구 평가시간은 각각 1,000, 1,650 h이었다. 고분자 막의 열화는 활성화에 의해 회복이 가능한 가역적 열화와 회복이 되지 않은 비가역적 열화로 구분했다. 고분자 막의 비가역적 열화는 수소투과도 증가로 나타나는데 수소투과도 변화가 세 MEA 모두 비가역적 열화 상수 c와 유사한 형태를 보였다. 회복이 되지 않은 비가역적 열화가 시작되는 것은 수소투과도 증가로 나타나고, 수소투과도 증가로 인해 OCV가 회복되지 않아서 OCV 회복선의 기울기가 감소하고 이를 실험식의 상수 c 값의 증가로 확인할 수 있었다.

CO2/N2 분리를 위한 Pebax 혼합막에서 Zeolitic Imidazolate Framework-7의 영향 (Effect of Zeolitic Imidazolate Framework-7 in Pebax Mixed Matrix Membrane for CO2/N2 Separation)

  • 윤숭석;홍세령
    • 공업화학
    • /
    • 제32권4호
    • /
    • pp.393-402
    • /
    • 2021
  • 본 연구는 대표적 poly(ether-b-amide)인 Pebax-1657과 Pebax-2533에 합성된 zeolitic imidazolate framework-7 (ZIF-7)을 넣어 혼합막을 제조하고, 단일기체 N2, CO2에 대한 투과 성질을 조사하였다. 기체투과 결과에서, N2의 경우 Pebax-1657/ZIF-7 혼합막과 Pebax-2533/ZIF-7 혼합막 모두 ZIF-7 혼입에 따라 투과도가 감소하는 비슷한 현상을 보였지만, CO2 투과도의 경우는 고분자에 종류에 따라 조금 다른 경향을 보였다. Pebax-1657/ZIF-7 혼합막의 경우는 ZIF-7의 0~3 wt% 함량 범위에서 CO2 투과도가 감소하다가 그 이후 함량에서 투과도가 증가하였고, Pebax-2533/ZIF-7 혼합막의 경우는 ZIF-7의 0~5 wt% 함량 범위에서 CO2 투과도 증가 없이 감소하였다. CO2/N2 선택도의 경우 두 혼합막 모두 ZIF-7의 함량이 많아짐에 따라 증가하는 경향을 보였으며, 특히 Pebax-2533/ZIF-7 5 wt%은 다른 혼합막들에 비해 가장 좋은 투과 성능을 보였다. 이는 ZIF-7이 Pebax-1657보다 Pebax-2533에 더 좋은 호환성을 보이며 CO2에 대한 선택적인 특성이 잘 나타났기 때문으로 생각된다.