• Title/Summary/Keyword: Membrane module

Search Result 348, Processing Time 0.021 seconds

Design, fabrication, and performance analysis of a twisted hollow fibre membrane module configuration

  • Palmarin, Matthew J.;Young, Stephanie;Lee, Tsun Ho
    • Membrane and Water Treatment
    • /
    • v.6 no.1
    • /
    • pp.15-26
    • /
    • 2015
  • The compact structure and high-quality effluent of membrane bioreactors make them well-suited for decentralized greywater reclamation. However, the occurrence of membrane fouling continues to limit their effectiveness. To address this concern, a unique membrane module configuration was developed for use in a decentralized greywater treatment system. The module featured local aeration directly below a series of inclined membrane bundles, giving the overall module a twisted appearance compared to a module with vertically orientated fibres. The intent of this design was to increase the frequency and intensity of collisions between rising air bubbles and the membrane surface. Material related to the construction of custom-fit modules is rarely communicated. Therefore, detailed design and assembly procedures were provided in this paper. The twisted module was compared to two commercially available modules with diverse specifications in order to assess the relative performance and marketability of the twisted module with respect to existing products. Contaminant removal efficiencies were determined in terms of biochemical oxygen demand, chemical oxygen demand, ammonia, total nitrogen, total phosphorus, and turbidity for each module. Membrane fouling was monitored in terms of permeate flux, transmembrane pressure, and membrane resistance. Following 168 h of operation, the twisted module configuration demonstrated competitive performance, indicating good potential for further development and commercialization.

A Study on Flow Rate Properties and Optimal Selection of Nitrogen Membrane Module of Hollow Fiber Type (중공사형 질소 분리막 모듈의 최적 선정과 유량특성에 관한 연구)

  • Kim, Jong-Do;Lee, Sangu-Su;Kim, Jeon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.915-922
    • /
    • 2008
  • The gas separation technology using membrane is widely used to refine various gases in many industry fields and recently is being applying in $CO_2$ recovery technology. In the gas and chemical tanker. nitrogen generators for inerting, purging and padding are on board and most of them have membrane modules of hollow fiber type with long life and vibration resisting properties. Because a membrane module is a key component accounting for 50% of total manufacturing cost of nitrogen generator, adequate selection for it is an important problem. In this paper, the flow performance coefficient based on dimension and specification data of membrane module was relatively selected to compare nitrogen generating capacity of module and various performance tests about the selected PARKER ST6010 membrane module were conducted. As a result, the useful coefficient and basic data in selecting a membrane module were achieved.

Multi- effect air gap membrane distillation process for pesticide wastewater treatment

  • Pangarkar, Bhausaheb L.;Deshmukh, Samir K.;Thorat, Prashant V.
    • Membrane and Water Treatment
    • /
    • v.8 no.6
    • /
    • pp.529-541
    • /
    • 2017
  • A multi-effect air gap membrane distillation (ME-AGMD) module for pesticide wastewater treatment is studied with internal heat recovery, sensible heat of brine recovery, number of stages and the use of fresh feed as cooling water in a single module is implemented in this study. A flat sheet polytetrafluroethylene (PTFE) membrane was used in the 4-stage ME-AGMD module. The maximum value of permeate flux could reach $38.62L/m^2h$ at feed -coolant water temperature difference about $52^{\circ}C$. The performance parameter of the module like, specific energy consumption and gain output ratio (GOR) was investigated for the module with and without heat recovery. Also, the module performance was characterized with respect to the separation efficiency of several important water quality parameters. The removal efficiency of the module was found to be >98.8% irrespective water quality parameters. During the experiment the membrane fouling was caused due to the deposition of the salt/crystal on the membrane surface. The membrane fouling was controlled by membrane module washing cycle 9 h and also by acidification of the feed water (pH=4) using 0.1M HCl solution.

A Study of the Development of a Radial Pleat Module for Low Pressure Using an Ultrafiltration Membrane

  • Seo, Il-Gun;Shin, Se-Jong;Byoung-Ryul;Song, Hee-Yeol
    • Korean Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.7-11
    • /
    • 2002
  • A radial pleat module using a polysulfone membrane was developed. The permeation characteristics of the radial pleat module were compared with those of a flat plate module. The average module efficiency of the radial pleat module for the applied pressure range was 82% and was always greater than that of the spiral wound module. For the radial pleat module, in general, as the applied pressure increases, the flux increases and the rejection reduces. The concentration polarization causes the decrease of the flux for the long time operation. But it has been found that the radial pleat module is more efficient for the reduction of the concentration polarization because it has the more effective area per unit volume and can induce the turbulent flow in the module.

An Experimental Study on the Characteristic of Thermal Performance according to Feed Water Conditions to of Vacuum Membrane Distillation Module using PVDF Hollow Fiber (PVDF 중공사막을 이용한 진공 막 증류 모듈의 공급수 조건에 따른 열성능 특성에 관한 실험적 연구)

  • Joo, Hongjin;Kwak, Heeyoul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.339-346
    • /
    • 2017
  • In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of $400m^3/day$ and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of $2m^3/day$ was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of $75^{\circ}C$ and flow rate of $8m^3/h$. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.

Reverse Osmosis and Nanofiltration Using the Disc-tube-module in the Purification of Landfill Leachate

  • Peters, Thomas A.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.06a
    • /
    • pp.27-38
    • /
    • 1995
  • Based on innovative membrane module concepts reverse osmosis and nanofiltration are going to become important instruments in environmental engineering. One example is the Disc-Tube-module and its application for the purification of landfill leachate. Currently over 45 different landfills are using this ROCHEM DT-module, in some cases combined with the high pressure reverse osmosis versions of this module, operating at up to 120 bar and 200 bar. This state of the art membrane technology and the DTF-module for nanofiltration, developed by ROCHEM on the basis of the DT-module and RO-systems for the purification of landfill leachate, make possible in hybrid processes permeate recovery rates of more than 97 % with concentration factors up to 40.

  • PDF

Analysis of Effect on Freshwater Production of Vacuum Membrane Distillation Module according to Housing Leak (중공사막 진공 막증류 모듈의 하우징 누수가 담수 생산에 미치는 영향 분석)

  • Joo, Hongjin;Kwak, Heeyoul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.313-319
    • /
    • 2016
  • In this study, the performance experiment was conducted to compare the permeate flux of hollow fiber Vacuum Membrane Distillation module according to leak problem between module housing and membrane bundle. For the permeate flux performance experiment of the two Vacuum Membrane Distillation modules, the Lab-scale experimental equipment was built in the capacity of $1m^3/day$. The performance test of the two Vacuum Membrane Distillation modules were analyzed according to the feed water conditions. As a result, it was analyzed that the leak VMD module decreased about 14% of permeate flux than normal VMD module.

Treatment and Reuse of Acrylic Wastewater using Membrane Separation System

  • Lee, Kwanghyun
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.117-120
    • /
    • 2004
  • The separation characteristics were investigated with the variations of pressure and temperature using ultrafiltration and reverse osmosis membrane module sets composed of different membrane types and materials. TDS, T-N and COD removal efficiencies were not affected and low with the change of temperature and pressure in case of using UF modules contained in module set 1, 2, 3. TDS, T-N and COD removal efficiencies were very high in RO modules. The final water quality of acrylic wastewater was satisfied within the discharge limit value of plant wastewater. It was known that membrane module sets could be used for the reuse of wastewater.

  • PDF

Characteristics of Protein Chromatography by Affinity Membrane Mudule (친화성 막모듈에 의한 단백질 크로마토그래픽 특성)

  • 이광진;염경호
    • KSBB Journal
    • /
    • v.13 no.2
    • /
    • pp.125-132
    • /
    • 1998
  • Protein affinity membrane was prepared via the coating of chitosan gel on the porous flat polysulfone membrane surface, followed by the immobilization f the reactive dye (Cibacron Blue 3GA) to the chitonsan gel. The maximum protein binding capacity of affinity membrane was about 70${\mu}g/cm^2$ determined by the batch adsorption experiments of human serum albumin (HSA). Using module of this membrane, the characteristics of protein chromatography were investigated through the experiments of elution and frontal chromatography of HSA. This membrane module promises as a chromatography column, since it represented a lower pressure drop and a greater reproducibility. The protein separation ratio was significantly influenced by the flow rate of mobile phase and the injection quantity of HSA. The dynamic protein binding capacity of module decreased from the equilibrium binding capacity with increasing flow rate and approached the value of 15 - 20 ${\mu}g/cm^2$ for flow rates above 6 mL/min.

  • PDF

Membrane Module for Greenhouse CO2 Supply Removal Effect of Harmful Pathogen (Phoma sp.) (온실 CO2 공급용 Membrane Module의 유해병원균(Phoma sp.)의 제거효과)

  • Kim, Seong-Sik;Kim, Hee-Tae;Jo, Jae-Min;Cho, Won-Jun;Kim, Hyeon-Tae
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.33-33
    • /
    • 2017
  • 본 연구는 온실 $CO_2$ 공급용 Membrane Module이 대기 중 $CO_2$를 포집하는 과정에서 유해병원균을 제거할 수 있는지 알아보기 위해 실험을 진행하였다. 본 실험은 Membrane Module과 유해병원균의 유무로 총 4개의 실험구, 포집하는 시간에 따라 1 min, 3 min, 5 min, 각각 3회씩, 총 36회의 실험을 진행하였다. 실험은 경상대학교 내 온실($W{\times}D{\times}H$, $3000{\times}4000{\times}2500mm$)에서 진행하였고, 유해병원균은 잎점무늬병을 일으키는 병원균(Phoma sp.)을 사용하였다. 온실에 Membrane System을 설치하고 Membrane Module을 통해 외부공기 또는 유해병원균이 포함된 공기를 분리하여 온실 내로 공급하고, 공급한 $CO_2$ 내에 유해병원균의 유무는 에어샘플러를 이용하여 온실 내의 공기를 포집 후 배지에 배양하여 확인하였다. 유해병원균은 PDA배지를 이용하여 포집한 뒤 항온항습기(HB-105SG-O, HANBAEK SCIENTIFIC CO., Korea)에 $25^{\circ}C$, 50%로 48시간 배양하였다. PDA배지 내에 배양된 미생물은 Colony Counter(HYC-560, CORETECH, Korea)로 측정하였다. 결과 값을 분석하기 위해서 IBM SPSS Statistics의 이원분산분석(two-way ANOVA)을 이용하여 통계분석 하였다. 결과 값은 유해병원균을 공급하고 Membrane Module을 사용하지 않았을 때, CFU(Colony-Forming Unit)가 가장 높았고, 유해병원균을 공급하고 Membrane Module을 사용했을 때 CFU가 가장 낮았다. 통계분석을 실시한 결과, Membrane Module을 사용하지 않은 실험구에는 유의한 차이가 나타났고, Membrane Module을 사용한 실험구에는 유의한 차이가 나타나지 않았다. 따라서 Membrane Module이 대기 중 $CO_2$를 분리하여 온실에 공급하는 과정에서 공기 중에 포함된 유해병원균을 제거 할 수 있다고 판단된다.

  • PDF