• Title/Summary/Keyword: Membrane filtration method

Search Result 116, Processing Time 0.024 seconds

Studies on the Analysis of Cations by Ion Chromatography (Ion Chromatography에 의한 혈액중에서 양ion의 분석에 관한 연구)

  • 박성우;김은호;유재훈;김을환
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.2
    • /
    • pp.113-119
    • /
    • 1990
  • Many studies on the analysis of cations in blood have been reported. However, no suitable method for the pretreatment of blood for the determination of cations by Ion Chromotography. As a result, pretreatment method that the membrane filtration of plasma a diluted 1 to 100 fold acidified pH 3.5 was found to be the most suitable. The recoveris of monovalent cations in blood were yield 101%(Na$^{+}$). 102%(NH$^{+}_{4}$) and 101%(K$^{+}$) Determinations of divalent cations(Mg and Ca ions) in blood by Ion chromatography were summarized as followed conditions Separator Column : CS$_{3}$. Suppressor Column : CMMS. Eluent conen : 25m M-HCl/2mM-Histidine. Regenerant conen: 40mM-Ba(OH)$_{2}$.

  • PDF

An Efficient Method for the Release of Recombinant Penicillin G Amidase from the Escherichia coli Periplasm (대장균의 periplasm으로부터 재조합 PGA 단백질의 효율적이고 간단한 방출 방법)

  • Lee, Sang-Mahn
    • Journal of Life Science
    • /
    • v.27 no.10
    • /
    • pp.1145-1151
    • /
    • 2017
  • In this study, we report on a simple, efficient method for obtaining penicillin G amidase (PGA) from recombinant Escherichia coli using a formulation mixed with detergent and lysozyme. Research was conducted on the extraction efficiency of PGA from the periplasmic space in cells in terms of the type of detergent, detergent concentration, pH, reaction time, and temperature of permeabilization. The extraction yield of PGA in the formulated surfactant/lysozyme treatment was increased by approximately (55-65 U/ml) in comparison with that in the single surfactant treatment. The released PGA solution was concentrated and exchanged with buffer using an ultrafiltration (U/F) system. The yields of diatomite filtration, membrane filtration (M/F), and U/F were 69.7%, 93.8%, and 77.3%, respectively. A total of 212 KU of PGA was recovered. At the 25-L culture scale, the overall yield of extraction using the mixed surfactant/lysozyme method was 49.2%. The specific activity of extracted PGA was 11 U/mg in protein. The concentrated PGA solution was immobilized on microporous silica beads without further purification of PGA. The total immobilization yield of PGA on the resin was 48.7%, while the enzyme activity was 101 U/g. The immobilized PGA was successfully used to produce 6-APA from penicillin G. Our results indicated that a simple extraction method from periplasmic space in E. coli may be used for the commercial scale production of ${\beta}-lactam$ antibiotics using immobilized PGA.

Evaluation of Membrane Damage Sensitivity by Defect Types for Improving Reliability of Membrane Integrity Monitoring (막 완결성 모니터링 신뢰성 향상을 위한 손상 유형별 막 손상 감도 평가)

  • Lee, Yong-Soo;Kang, Ha-Young;Kim, Hyung-Soo;Kim, Jong-Oh
    • Membrane Journal
    • /
    • v.27 no.3
    • /
    • pp.248-254
    • /
    • 2017
  • In order to secure the reliability of pathogenic microorganisms such as Cryptosporidium and Giaridia, which are chlorophilic protozoans, membrane filtration systems have been widely used in water purification process. hese integrity tests are classified into direct and indirect methods. Based on the bubble point theory, the pressure-based test in the direct method is presented in the USEPA Guidance Manual with sensitivity to detect a minimum size of pathogenic microorganisms of $3{\mu}m$ or more. Indirect methods are widely used in that they are capable of continuous operation in on-line state, but there is a very low sensitivity of damage detection compared to the direct method, and there is a limit that can not specify the damage area, so it is necessary to improve this sensitivity. In this study, we compared the LRVDIT and UCL values according to the type of membrane defect, number of fiber breaks, and initial set pressure value through the Integrity Test by Pressure Decay Test (PDT).

Effect of Natural Convection Instability on Reduction of Fouling and Increasing of Critical Flux in Constant-flow Ultrafiltration (정유량 한외여과에서 자연대류 불안정성의 막오염 감소 및 임계 플럭스 증가 효과)

  • Jang, A-Rum;Nam, Sang-Won;Youm, Kyung-Ho
    • Membrane Journal
    • /
    • v.22 no.5
    • /
    • pp.332-341
    • /
    • 2012
  • We studied the effects of induction of natural convection instability flow (NCIF) according to the gravitational orientation (inclined angle) of the membrane cell on the reduction of membrane fouling in the constant-flow ultrafiltration (UF) of colloidal silica solutions. Five colloidal silica solutions with different silica size (average size = 7, 12, 22, 50 nm and 78 nm) were used as UF test solutions. The silica particles in colloidal solutions form cakes on the membrane surface thereby causing severe membrane fouling. The constant-flow UF performance according to the gravitational orientation of the membrane cell (from $0^{\circ}$ to $180^{\circ}$ inclined angle), was examined in an unstirred dead-end cell. We evaluate the effects of NCIF on the suppression of fouling formation by measuring the variation of transmembrane pressure (TMP) and the increase of critical flux by using the flux-stepping method. In the constant-flow dead-end UF for the smaller size (7, 12 nm and 22 nm) silica colloidal solutions, changing the gravitational orientation (inclined angle) of the membrane cell above the $30^{\circ}$ angle induces NCIF in the membrane module. This induced NCIF enhances back transport of the deposited silica solutes away from the membrane surface, therefore gives for the reduction of TMP. But in the constant-flow UF for the more larger size (50 nm and 78 nm) silica colloidal solutions, NCIF effects are not appearing. The critical flux is increased as increasing the module angle and decreasing the silica size. Those results show that the intesity of NCIF occurrence in membrane module is more higher as increasing the module angle and decreasing the silica size.

Preparation and Anti-fouling Properties of PVDF Mixed Matrix Asymmetric Membranes Impregnated with 𝛽-cyclodextrin (𝛽-사이클로덱스트린을 함침시킨 PVDF 혼합기질 비대칭막의 제조와 내오염성 평가)

  • Shin, Sung Ju;Lee, Jong Sung;Lee, Jeong Gil;Youm, Kyung Ho
    • Membrane Journal
    • /
    • v.31 no.6
    • /
    • pp.434-442
    • /
    • 2021
  • Poly(vinylidene fluoride) (PVDF) membrane has a good membrane durability because of its high mechanical resistance, thermal and chemical stability. However, the strong hydrophobic property of PVDF membrane can induce a low water permeability and easy fouling by proteins and organic matters. In order to improve the anti-fouling properties of PVDF membrane, the PVDF mixed matrix asymmetric membranes impregnated with biofunctional material 𝛽-cyclodextrin (𝛽-CD) in the membrane structure were prepared by phase inversion method. The membrane filtration experiments of pure water and BSA solution were performed using the PVDF/𝛽-CD mixed matrix asymmetric membranes prepared according to the 𝛽-CD contents. The experiments showed that the introduction of 𝛽-CD into the PVDF polymer matrix contributed to increase in the hydrophilic property of the PVDF membranes, and this led to the reduction of contact angles and improvement of anti-fouling properties. The PVDF/𝛽-CD membrane which was prepared using the dope solution with a 2 wt% 𝛽-CD content represented 64 L/m2·h of pure water flux, 95% of BSA rejection and maximum 80% of flux enhancements compared to flux results of the pristine PVDF membrane.

Improving Physical Fouling Tolerance of PES Filtration Membranes by Using Double-layer Casting Methods (PES 여과막의 물리적 막오염 개선을 위한 기공 구조 개선 연구)

  • Chang-Hun Kim;Youngmin Yoo;In-Chul Kim;Seung-Eun Nam;Jung-Hyun Lee;Youngbin Baek;Young Hoon Cho
    • Membrane Journal
    • /
    • v.33 no.4
    • /
    • pp.191-200
    • /
    • 2023
  • Polyethersulfone (PES) is a widely employed membrane material for water and industrial purification applications owing to its hydrophilicity and ease of phase separation. However, PES membranes and filters prepared using the nonsolvent induced phase separation method often encounter significant flux decline due to pore clogging and cake layer formation on the dense membrane surfaces. Our investigation revealed that tight microfiltration or loose ultrafiltration membranes can be subject to physical fouling due to the formation of a dense skin layer on the bottom side caused by water intrusion to the gap between the shrank membrane and the substrate. To investigate the effect of the bottom surface porosity on membrane fouling, two membranes with the same selective layers but different sub-layer structures were prepared using single and double layer casting methods, respectively. The double layered PES membrane with highly porous bottom surface showed high flux and physical fouling tolerance compared to the pristine single layer membrane. This study highlights the importance of physical optimization of the membrane structure to prevent membrane fouling.

A Microfluidic Chip-Based Creatinine Filtration Device (마이크로 플루이딕 칩을 기반으로 한 크레아티닌 여과장치)

  • Lee, Sack;Shin, Dong-Gyu;Nguyen, Thanh Qua;Park, Woo-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.12
    • /
    • pp.921-925
    • /
    • 2015
  • The number of people suffering from renal disease increases every year. One of the most common treatments (clinical care options) for renal diseases is hemodialysis. However it takes a long time and has a high cost. Therefore, the importance of artificial kidney research has risen. Filtering creatinine from blood is one of the prime renal functions. Thus, we designed a novel two channel microfluidic chip focused on that function. In order to bond the individual polydimethylsiloxane layers, we have developed a housing system using acrylic plastic frame. This method has significant advantages in changing filter membranes. We use anodic aluminum oxide for the filter membrane. We analyzed the difference in the absorbance values for various creatinine concentrations using the Jaffe reaction. For the purpose of acquiring a standard equation to quantify the creatinine concentration, we interpolated the measured data and confirmed the concentration of the filtered solution. Through this experiment, we determined how the filtration efficiency depended on the flow rate and creatinine concentration.

Development of point-of-use filter evaluation method using chemical mechanical planarization slurry (Chemical mechanical planarization 슬러리에 사용되는 point-of-use 필터의 평가 방법 개발)

  • Jang, Sunjae;Kulkarni, Atul;Kim, Hyeong-U;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.145-150
    • /
    • 2016
  • During the chemical mechanical planarization (CMP) process, slurry that comprises abrasive particles can directly affect the CMP performance and quality. Mainly, the large particles in the slurry can generate the defects on the wafer. Thus, many kinds of filters have been used in the CMP process to remove unwanted over-sized particles. Among these filters, the point-of-use (POU) filter is used just before the slurry is supplied onto the CMP pad. In the CMP research field, analysis of the POU filter has been relatively exceptional, and previous studies have not focused on the standardized filtration efficiency (FE) or filter performance. Furthermore, conventional evaluation methods of filter performance are not appropriate for POU filters, as the POU filter is not a membrane type, but is instead a depth type roll filter. In order to accurately evaluate the POU filter, slurry FE according to particle size was measured in this study. Additionally, a CMP experiment was conducted with filtered slurry to demonstrate the effects of filtered slurry on CMP performance. Depending on the flow rate and the filter retention size, the FE according to particle size was different. When the small and large particles have different FEs, the total filtration efficiency (TFE) can still have a similar value. For this reason, there is a need to measure the FE with respect to the particle size to verify the effects of the POU filter on the CMP process.

A study on possibility of using CST as a fouling evaluation index at MBR (MBR에서 fouling 평가지표로서 CST의 활용 가능성에 대한 연구)

  • Kim, Yun-Ji;Choi, Yun-Jeong;Sim, Tae-Suk;Hwang, Sun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.379-387
    • /
    • 2021
  • In general, trans-membrane pressure (TMP), flux, filtration resistance are used as indicators to evaluate the degree of fouling in MBR. However, they have limitations in determining the level of EPS generation, which is known as an important factor of fouling. Therefore, a new evaluation method is required to monitor the amount of EPS generation. In this study, the applicability of capillary suction time (CST), which is used to measure the dewaterability of sludge, was evaluated as an indirect fouling evaluation index. Statistical analysis was performed to evaluate the effect of EPS on CST, and to determine whether EPS has high similarity with representative fouling evaluation indicators and CST, and quantitatively compared them. As a result, the correlation coefficient between CST and bEPS was 0.7988, which was higher than the correlation coefficient between filtration resistance and bEPS. Since bEPS is a major factor inducing fouling by affecting the formation of the cake layer, it was evaluated that CST, which has a high correlation with bEPS, is suitable to represent EPS. In addition, it was evaluated that the correlation coefficient between filtration resistance and CST was high as 0.7187, which could be used as a fouling evaluation index.

An early fouling alarm method for a ceramic microfiltration pilot plant using machine learning (머신러닝을 활용한 세라믹 정밀여과 파일럿 플랜트의 파울링 조기 경보 방법)

  • Dohyun Tak;Dongkeon Kim;Jongmin Jeon;Suhan Kim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.5
    • /
    • pp.271-279
    • /
    • 2023
  • Fouling is an inevitable problem in membrane water treatment plant. It can be measured by trans-membrane pressure (TMP) in the constant flux operation, and chemical cleaning is carried out when TMP reaches a critical value. An early fouilng alarm is defined as warning the critical TMP value appearance in advance. The alarming method was developed using one of machine learning algorithms, decision tree, and applied to a ceramic microfiltration (MF) pilot plant. First, the decision tree model that classifies the normal/abnormal state of the filtration cycle of the ceramic MF pilot plant was developed and it was then used to make the early fouling alarm method. The accuracy of the classification model was up to 96.2% and the time for the early warning was when abnormal cycles occurred three times in a row. The early fouling alram can expect reaching a limit TMP in advance (e.g., 15-174 hours). By adopting TMP increasing rate and backwash efficiency as machine learning variables, the model accuracy and the reliability of the early fouling alarm method were increased, respectively.