• 제목/요약/키워드: Membrane electrode assembly (MEA)

검색결과 106건 처리시간 0.026초

직접메탄올 연료전지의 농도 및 온도변화에 따른 실험적 검증 (Experimental Validation of a Direct Methanol Fuel Cells(DMFCs) model with a Operating Temperatures and Methanol Feed Concentrations)

  • 강경문;고요한;이기용;주현철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.125.2-125.2
    • /
    • 2010
  • In this paper, both theoretical and experimental investigations have been performed to examine the effects of key operating parameters on the cell performance of a DMFCs (i.e., methanol feed concentration and operating temperature). For experiment, the membrane electrode assemblies (MEAs) were prepared using a conventional MEA fabrication method based on a catalyst coated electrode (CCE) and tested under various cell temperatures and methanol feed concentrations. The polarization curve measurements were conducted using in-house-made $25cm^2$ MEAs. The voltage-current density data were collected under three different cell temperatures ($50^{\circ}C$, $60^{\circ}C$, and $70^{\circ}C$) and four different methanol feed concentrations (1 M, 2 M, 3 M, and 4 M). The experimental data indicate that the measured I-V curves are significantly altered, depending on these conditions. On the other hand, previously developed one-dimensional, two-phase DMFC model is simulated under the same operating conditions used in the experiments. The model predictions compare well with the experimental data over a wide range of these operating conditions, which demonstrates the validity and accuracy of the present DMFC model. Furthermore, both simulation and experimental results exhibit the strong influences of methanol and water crossover rates through the membrane on DMFC performance and I-V curve characteristics.

  • PDF

직접메탄올 연료전지에서 전지 성능에 대한 확산층의 영향 (Effect of Diffusion Layer for Cell Performance in DMFC)

  • 권부길;박경원;최종호;성영은
    • 한국전기화학회:학술대회논문집
    • /
    • 한국전기화학회 2001년도 연료전지심포지움 2001논문집
    • /
    • pp.179-184
    • /
    • 2001
  • The diffusion layer within MEA(membrane electrode assembly) has been evaluated important factor for improvement of cell performance in DMFC. The diffusion layer in MEA structure leads to the reduction of catalyst loss in active catalysts layer as well as prevention of water-flooding in cathode. Cell performance is directly affected by interior properties of diffusion layer materials. Acetylene Black and $RuO_2$ with large pore size and low porosity compared to Vulcan XC-72R gave better performance caused by vigorous methanol diffusion and water removal. And $RuO_2$ as diffusion layer materials showed different behavior in anode and cathode compartment, that is, diffusion layers in anode and cathode side make methanol diffusion and water removal facilitate, respectively.

  • PDF

연료전지스택 바깥판의 위상최적설계 (Topology Optimization for End Plate of Fuel Cell Stack)

  • 최우석;오성진;김성종;홍병선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.456-461
    • /
    • 2003
  • A fuel cell is an electrochemical device in which the energy of a chemical reaction is converted directly into electricity. By combining hydrogen fuel with oxygen from air, electricity is formed, without combustion of any form. Water and heat are the only by-products when hydrogen is used as the fuel source. Fuel cell stack consists of multi-layered unit cells. A unit cell consists of MEA and bipolar plates. The end plate of fuel cell stack should give a uniform distributed pressure to multi unit cell layers so as to reduce the contact resistance and to prevent the leakage of reactant gases and the damage of multi layer components. The current end plate is redundantly large and heavy. It makes the power per unit volume reduced. Topology optimization of end plate is conducted for mass reduction and enhancement of bending rigidity. The evaluation of the current design and the recommendation for the future design is remarked.

  • PDF

시동/정지반복에 의한 공랭식 고분자연료전지 스택 내구성 평가 (Durability Evaluation of Air-Cooled Proton Exchange Membrane Fuel Cells Stacks by Repeated Start-Up/Shut-Down)

  • 유동근;김현석;오소형;박권필
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.315-323
    • /
    • 2021
  • The air-cooled proton exchange membrane fuel cells (PEMFC) stacks, which is widely used in small-sized PEMFC, have a problem in that durability is weaker than that of the water-cooled type. Because the cathode is open to the atmosphere and the structural problem of the air-cooled stack, which is difficult to maintain airtightness, is highly likely to form a hydrogen/air boundary during start-up/shut-down (SU/SD). Through the accelerated durability evaluation of the 20 W air-cooled PEMFC stack, the purpose of this study was to find out the cause of the degradation of the stack and to contribute to the improvement of the durability of the air-cooled PEMFC stack. In this study, it was possible to evaluate durability in a relatively short time by reducing 20-30% of initial performance by repeating SU/SD 1,000 to 1,200 times on an air-cooled PEMFC stack. After disassembling the stack, each cell was divided into two and the performance analysis showed that the electrode degradation was more severe in the anode outlet membrane electrode assembly (MEA), which facilitates air inflow as a whole, than in the inlet MEA. It was shown that the cathode Pt was dissolved/precipitated to deteriorate the polymer ionomer inside the membrane.

고온 고분자 막 전해질 연료전지 캐소드의 가스 확산층 및 바인더 함량에 따른 완화 시간 분포(DRT) 저항 분석 (Resistance Analysis by Distribution of Relaxation Time According to Gas Diffusion Layers and Binder Amounts for Cathode of High-temperature Polymer Electrolyte Membrane Fuel Cell)

  • 김동희;정현승;박찬호
    • 한국수소및신에너지학회논문집
    • /
    • 제34권3호
    • /
    • pp.283-291
    • /
    • 2023
  • The physical properties were analyzed for four gas diffusion layers, and gas diffusion electrodes (GDEs) for the cathode of high-temperature polymer electrolyte membrane fuel cell were fabricated through bar coating with three binder to carbon (B/C) ratios. Among them, The GDE from JNT30-A6P showed a significant change in secondary pore volume at a B/C ratio of 0.31, which had the largest pore volume among all GDEs. In the polarization curve, JNT30-A6P GDE showed the best membrane electrode assembly (MEA) performance with a peak power density of 384 mW/cm2 at a a B/C ratio of 0.31. From the distribution of relaxation time analysis, the peak 1 corresponding to mass transfer resistance of oxygen reduction reaction (ORR) was significantly reduced in the JNT30-A6P GDE. This is the result that when the binder content decreased, the volume of the secondary pore increased, and the mass transfer resistance of ORR decreased, which played an essential role in the MEA performance.

Electrospun Poly(Ether Sulfone) Membranes Impregnated with Nafion for High-Temperature Polymer Electrolyte Membrane Fuel Cells

  • Lee, Hong Yeon;Hwang, Hyung Kwon;Lee, Jin Goo;Jeon, Yukwon;Park, Dae-Hwan;Kim, Jong Hak;Shul, Yong-Gun
    • 전기화학회지
    • /
    • 제19권1호
    • /
    • pp.9-13
    • /
    • 2016
  • Electrospun poly(ether sulfone) (PES) membrane impregnated with Nafion (PES-N) have been developed for high-temperature polymer-electrolyte membrane fuel cell (HT-PEMFC). The PES-N obtains highly thermal stability up to $430^{\circ}C$, which is higher than that of the commercial Nafion 212. The PES-N membrane shows a good proton conductivity of about $10^{-2}S\;cm^{-1}$ in a temperature range from $75^{\circ}C$ to $120^{\circ}C$. The membrane-electrode assembly (MEA) with the PES-N membrane exhibits a current density of $1.697A\;cm^{-2}$ at $75^{\circ}C$, and $0.813A\;cm^{-2}$ at $110^{\circ}C$ when the applied voltage is 0.6 V, whereas the MEA with the Nafion 212 membrane shows the current density of $0.647Acm^{-2}$ at $110^{\circ}C$. The results suggest that the PES-N can be a good candidate for a polymer electrolyte membrane of the HT-PEMFC.

VISUALIZATION OF THE INTERNAL WATER DISTRIBUTION AT PEMFC USING NEUTRON IMAGING TECHNOLOGY: FEASIBILITY TEST AT HANARO

  • Kim Tae-Joo;Jung Yong-Mi;Kim Moo-Hwan;Sim Cheul-Muu;Lee Seung-Wook;Jeon Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • 제38권5호
    • /
    • pp.449-454
    • /
    • 2006
  • Neutron imaging technique was used to investigate the water distribution and movement in Polymer Electrolyte Membrane Fuel Cell (PEMFC) at HANARO, KAERI. The Feasibility tests were performed in the first and second exposure rooms at the neutron radiography facility (NRF) at HANARO in order to check the ability of each exposure room, respectively. The feasibility test apparatus was composed of water and pressurized air before making up the actual test apparatus. Due to the low neutron intensity in the second exposure room, the exposure time was too long to investigate the transient phenomena of PEMFC. Although the exposure time was improved to 0.1 sec in the first exposure room, it was difficult to discriminate detail water movement at the channel due to the high noise level. Therefore, the experimental setup must be optimized according to the test conditions. Water discharge characteristics were investigated under different flow field geometries by using feasibility test apparatus and the neutron imaging technique. The water discharge characteristics of a 3-parallel serpentine are superior to those of a 1-parallel serpentine, but water at Membrane Electrode Assembly (MEA) was not removed, regardless of the flow field type.

자동차용 고분자전해질형연료전지 스택에서의 막-전극접합체 설계인자가 저온시동에 미치는 영향성 연구 (Analyzing the Effects of MEA Designs on Cold Start Behaviors of Automotive Polymer Electrolyte Fuel Cell Stacks)

  • 곽건희;고요한;주현철
    • 한국수소및신에너지학회논문집
    • /
    • 제23권1호
    • /
    • pp.8-18
    • /
    • 2012
  • This paper presents a three-dimensional, transient cold-start polymer electrolyte fuel cell (PEFC) model to numerically evaluate the effects of membrane electrode assembly (MEA) design and cell location in a PEFC stack on PEFC cold start behaviors. The cold-start simulations show that the end cell experiences significant heat loss to the sub-freezing ambient and thus finally cold-start failure due to considerable ice filling in the cathode catalyst layer. On the other hand, the middle cells in the stack successfully start from $-30^{\circ}C$ sub-freezing temperature due to rapid cell temperature rise owing to the efficient use of waste heat generated during the cold-start. In addition, the simulation results clearly indicate that the cathode catalyst layer (CL) composition and thickness have an substantial influence on PEFC cold-start behaviors while membrane thickness has limited effect mainly due to inefficient water absorption and transport capability at subzero temperatures.

5kW급 고분자 연료전지 시스템의 개발과 운전 (Development and Operation of 5kW-Class Polymer Electrolyte Membrane Fuel Cell System)

  • 전영갑;백동현;전광선;김창수;신동렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1876-1878
    • /
    • 1999
  • Developed was a 5kW-class polymer electrolyte membrane fuel cell(PEMFC) system comprised of fuel cell stack, fuel processing, thermal and water management subsystems and ancillary equipments. Several large single cells have been fabricated with different gas flow field patterns and paths, and the gas flow field pattern for the stack has been determined based on the single cell performance of thin film membrane electrode assembly (MEA). The PEMFC stack was consisted of 100 cells with an electrode area of $300cm^2$, having serpentine flow pattern. Fuel processing was developed including an autothermal methanol reformer and two preferential CO oxidation reactors. The fuel processing was combined to PEMFC operation system consisted of air compressor and thermal and water management subsystems. The PEMFC stack showed performance of 5kW under the supply of $H_2$ and air, but its performance was lowered to 3.5kW under the supply of reformed gas.

  • PDF

sPEEK 막으로 제조한 고분자전해질 연료전지(PEMFC) 막전극합체(MEA)의 특성 (Characteristics of Proton Exchange Membrane Fuel Cells(PEMFC) Membrane and Electrode Assembly(MEA) Using Sulfonated Poly(ether ether ketone) Membrane)

  • 이혜리;이세훈;황병찬;나일채;이정훈;오성준;박권필
    • Korean Chemical Engineering Research
    • /
    • 제54권2호
    • /
    • pp.181-186
    • /
    • 2016
  • 최근에 저가의 고분자 전해질 연료전지(Proton Exchange Membrane Fuel Cells, PEMFC)용 비불소계 전해질 막 연구개발이 활발히 진행되고 있다. 본 연구에서는 sulfonated Poly(ether ether ketone)(sPEEK)막의 특성을 술폰화도, 상대습도, 단위 전지 온도에 따라 PEMFC 운전 조건에서 비교하였다. I-V 분극곡선, 수소투과도, 전기화학적 표면적, 막 저항 및 부하 전달 저항 등을 측정 분석했다. 술폰화도와 온도, 상대습도가 높을수록 성능이 높았으며, 특히 낮은 슬폰화도와 낮은 상대습도에서 이온 전도도 감소 때문에 성능이 큰 폭으로 감소함을 확인하였다.