• 제목/요약/키워드: Membrane Oxygenator

검색결과 49건 처리시간 0.022초

국산 막형 산화기 (OXYREX)의 체외순환 임상 성적 - 개심수술 40례 적용 - (Clinical Application of OXYREX Hollow Fiber Membrane Oxygenator)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • 제23권6호
    • /
    • pp.1049-1056
    • /
    • 1990
  • The OXYREX hollow fiber membrane oxygenator developed by joint work of KIST and Green Cross Medical company has been evaluated by experimental investigation and clinical application, In this oxygenator gas exchanges occur through small pores of 0.1pm size which are distributed on 70% of surface of polypropylene hollow fiber. The Oxyrex membrane oxygenator consists of 36 thousand hollow fibers and it has 3.3m2 of gas exchange surface. The Oxyrex membrane oxygenator has unique blood flow path: blood enters the oxygenator passes between the hollow fibers and exits through outlet ports, that provides low transmembrane pressure drop. In the animal experiment and in vitro investigations of Oxyrex oxygenator, it showed low transmembrane pressure difference, effective heat exchanger performance, stable gas transfer function and less blood trauma. The Oxyrex oxygenator been used from March, 1990, to October, 1990, in 40 patients undergoing open heart operations. In the clinical applications of Oxyrex, adequate oxygenation[PaO2, 283$\pm$70mmHg] and carbon dioxide removal[PaCO2, 27\ulcorner6mmHg]were maintained under the condition of FiO2: below 0.6, Hct; 25%, perfusion flow; 2.4 L/min, gas flow: 2.1 L/min. During maximum 365 minutes of cardiopulmonary bypass[CPB] time period, the Oxyrex oxygenator maintained stable condition of PaO2, PaCO2 respectively and it also kept low plasma hemoglobin level. The complement proteins C3 and CH50 were not significantly changed pre to post CPB. There were no complications related to the oxygenator during and after the CPB.

  • PDF

개심술시 체외순환이 혈소판에 미치는 영향 (Effect of Cardiopulmonary Bypass on Platelet)

  • 최대융
    • Journal of Chest Surgery
    • /
    • 제25권5호
    • /
    • pp.526-532
    • /
    • 1992
  • The effect of cardiopulmonary bypass on platelet count and function was studied in 20 patients who underwent cardiac operation from April 1991 to August 1991 at the Department of thoracic and Cardiovascular Surgery, School of Medicine, Keimyung University. Ten patients were perfused with a bubble oxygenator, 10 with a membrane oxygenator. During and after bypass, platelet counts decreased in both groups and significantly reduced in those perfused with a bubble oxygenator. All 20 patients studied for platelet functions had an abnormal postoperative aggregation response to collagen and epinephrine, but no significant difference in both groups. One hour after bypass, bleeding times increased in both groups but did not differ significantly between groups. Postoperative 24 hour blood losses were significantly higher in patients perfused with a membrane oxygenator. Platelet damage and postoperative blood loss are less severe after cardiopulmonary bypass performed with a membrane oxygenator than with a bubble oxygenator.

  • PDF

CFD 해석을 이용한 Balloon형 인공심폐기 설계를 위한 구조적 해석 (Structural Analysis for Constructing a Balloon Type Extracoporeal Membrane Oxygenator using CFD Analysis)

  • 박영란;심정연;김기범;김상진;강형섭;김진상;김민호;홍철운;김성종
    • Korean Chemical Engineering Research
    • /
    • 제49권2호
    • /
    • pp.238-243
    • /
    • 2011
  • 본 연구는 기존의 인공심폐기의 단점을 보완하기 위하여 혈액펌프를 사용하지 않고 혈류의 흐름을 유도할 수 있는 기구(balloon)형 인공심폐기 설계를 위한 구조적 해석을 시도하였다. 가상의 모형 인공심폐기 내에서의 혈류의 흐름패턴을 분석하기 위하여 CFD 모델링 방법을 사용하였다. 이 시스템의 작동원리는 막 산화기 주위를 기구를 사용하여 압력하중을 인가하여 주기적으로 수축.이완되도록 하였으며, 시간에 따라 변화하는 시간 함수 값은 sine 반주기와 sine 주기를 계산하여 적용하였다. 이와 같은 방법으로 기구형 인공심폐기를 설계할 경우 한 방향에 대한 혈류의 움직임을 유도할 수 있다는 가정 하에 구조적 해석을 하였다. 실험결과 CFD 시뮬레이션을 통하여 인공심폐기의 입구와 출구에 서의 혈류의 속도와 압력을 측정하여 분석한 결과 한 방향에 대한 혈류의 유동이 발생하는 것을 확인하였다. 이와 같은 CFD 시뮬레이션은 혈류의 흐름특성을 미리 예측할 수 있어 인공심폐기 설계에 있어서 최적화된 디자인을 제공할 수 있을 것이라 판단된다.

이동형 심폐보조시스템의 개발 (Development of Portable Cardiopulmonary Support System)

  • 이혁수;민병구
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.94-99
    • /
    • 2007
  • 협심증과 급성 심근 경색증 등 관상동맥 질환이 급증함에 따라 병원 밖이나 응급실 중환자실 심도자 검사실 등에서 급성 심장 쇼크에 빠지거나 심장마비가 발생하는 경우가 많이 발생하고 있다. 이러한 심혈관 질환에는 정류성 체외생명보조장치가 널리 사용되고 있으나 이러한 장치는 그 무게와 크기로 인해 응급상황에 대처할 수 있는 능력이 작고, 막형 산화기의 전단에 인가되는 압력이 크며, 시스템 구성상 혈액이 공기에 노출된다. 박동성 혈류를 공급하기 위하여 단일 구동펌프를 이용한 시도가 있었으나 회로내의 순간 압력 상승 등으로 인한 여러 가지 단점들이 발생한다. 이러한 기존의 체외생명보조장치의 단점을 극복하고자 한국형 인공심장의 원리를 이용한 이중 박동식 혈액펌프를 개발하였다. 이 시스템의 구동원리는 막형산화기를 중심으로 전.후에 혈액펌프를 위치하여 혈액펌프를 Actuator가 한번씩 짜주는 것이다. 이런 방법으로 구동할 경우 막형산화기 후단에 있는 펌프가 음압을 동시에 일으킴으로, 막형산화기에 인가되는 큰 양압을 줄인다는 가정 하에 시스템을 개발한 것이다. 생체외 실험을 통하여 각 부분의 압력을 측정하고, 총 12건의 동물실험을 통하여 그 장점을 검증하였다

체외순환이 보체활성화화 백혈구의 폐내 정체에 미치는 영향에 관한 연구 (A Study on Effect to Complement Activation and Pulmonary Leukostasis During Cardiopulmonary bypass: Comparison of Bubble Oxygenator and Membrane Oxygenator)

  • 김양원;최석철;조광현
    • Journal of Chest Surgery
    • /
    • 제28권7호
    • /
    • pp.649-657
    • /
    • 1995
  • From December 1993 to April 1994, to investigate complement activation and pulmonary leukostasis, thirty adult patients were studied during cardiopulmonary bypass[CPB for cardiac surgery in Department of Cardiovascular & Thoracic Surgery, Pusan Paik Hospital, Inje University. Total patients were divided into group I and II according to the purpose of study ; Group I was 15 patients undergoing CPB with bubble oxygenator, Group II was 15 patients undergoing CPB with membrane oxygenator. The results of study were summarized as follows.1. The decrease of C3 and C4 levels were observed within few minutes of beginning of CPB in all patients[P<0.05 , and this decrease was proved to be due to complement activation, not by the influence of hemodilution.2. In the correlation between the change of C3 and C4, group I showed linear correlation each other suggesting complement activation occurred through the classical pathway, group II showed a correlation at only partial sampling times suggesting complement activation via both classical and alternative pathway, however there was no significant statistical difference at the change of C3 and C4 concentrations in two groups[P>0.05 .3. After switching to partial CPB, a few difference between right atrial and left atrial WBC count was observed, but statistically not significant and median cell count difference between group I and II was not significant, too [P>0.05 . With the above result, we concluded that CPB itself contributes to the activation of complement system, but bubble oxygenator does not activate always complement system more than membrane oxygenator.

  • PDF

Experiences of Tracheal Procedure Assisted by Extracorporeal Membrane Oxygenator

  • Kim, Ji Eon;Jung, Sung-Ho;Ma, Dae Sung
    • Journal of Chest Surgery
    • /
    • 제46권1호
    • /
    • pp.80-83
    • /
    • 2013
  • We report on the application of a venovenous type extracorporeal membrane oxygenator (ECMO) in high-risk tracheal procedures in six cases consisting of five patients with tracheal stenosis. An ECMO should be helpful for preventing respiratory emergency during a tracheal procedure.

체외순환이 혈소판에 미치는 영향 (Effect of Cardiopulmonary Bypass on Platelet)

  • 최준영;서경필
    • Journal of Chest Surgery
    • /
    • 제21권1호
    • /
    • pp.26-35
    • /
    • 1988
  • The effect of cardiopulmonary bypass on platelet count, platelet function, and bleeding time was studied in 60 patients. Platelet count was significantly reduced during and after cardiopulmonary bypass. Platelet function also had a reduced aggregation response to adenosine diphosphate. Bleeding time was prolonged to over 30 minutes during cardiopulmonary bypass and not returned to normal level until postbypass 1 hour. The amount of postoperative bleeding was proportional to the degree of decrease in platelet count and function, degree of decrease in platelet count and function. There was no significant correlation between duration of cardiopulmonary bypass and platelet count, platelet function, bleeding time, or amount of postoperative bleeding. Patients with cyanotic congenital heart disease showed a larger amount of postoperative bleeding than patients with acyanotic congenital heart disease [P<0.01], and this difference was due to the fact that platelet function was more significantly affected by cardiopulmonary bypass in cyanotic group. Patients using membrane oxygenator showed a less amount of postoperative bleeding than patients using bubble oxygenator [p<0.005] reflecting better preservation of platelet count and function by membrane oxygenator.

  • PDF

체외순환후 혈청내 Immunoglobulin 과 보체의 변화에 관한 연구 - 막형 인공산화기와 기포형 인공산화기의 비교 - (Changes of Plasma Immunoglobulins and Complements after Extracorporeal Circulation)

  • 이철주
    • Journal of Chest Surgery
    • /
    • 제21권4호
    • /
    • pp.613-618
    • /
    • 1988
  • The exposure of blood to foreign materials can cause the denaturation of plasma protein components such as immunoglobulins and complements. And those phenomena increase the morbidity and mortality after intracardiac operations through the cardiopulmonary bypass. From April, 1987 to September, 1987, we had observed the serial changes of plasma total protein IgG, IgA, IgM, complements[C3, C4] in bubble oxygenator group[n=5] and membrane oxygenator group[n=5]. Statistically significant difference between two groups were present in total protein and C3. We conclude that using membrane oxygenator in long extracorporeal circulation can reduce the activation of alternative pathway of complement system, and which can reduce post-perfusion complications of the lung though we can`t prove it in mass populations.

  • PDF