• 제목/요약/키워드: Medium power system

Search Result 501, Processing Time 0.033 seconds

A Dependability Modeling of Software Under Memory Faults for Digital System in Nuclear Power Plants

  • Park, Jong-Gyun;Seong, Poong-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.433-443
    • /
    • 1997
  • In this work, an analytic approach to the dependability of software in the operational phase is suggested with special attention to the hardware fault effects on the software behavior : The hardware faults considered are memory faults and the dependability measure in question is the reliability. The model is based on the simple reliability theory and the graph theory which represents the software with graph composed of nodes and arcs. Through proper transformation, the graph can be reduced to a simple two-node graph and the software reliability is derived from this graph. Using this model, we predict the reliability of an application software in the digital system (ILS) in the nuclear power plant and show the sensitivity of the software reliability to the major physical parameters which affect the software failure in the normal operation phase. We also found that the effects of the hardware faults on the software failure should be considered for predicting the software dependability accurately in operation phase, especially for the software which is executed frequently. This modeling method is particularly attractive for the medium size programs such as the microprocessor-based nuclear safety logic program.

  • PDF

Reliability for SF6 gas load break switch of distribution system (배전선로용 가스절연부하개폐기의 신뢰성 향상책)

  • Park, Seung-Jae;Heo, Jong-Chul;Shin, Young-June;Kang, Young-Sik;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.452-454
    • /
    • 2003
  • $SF_6$ gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, most of power companies adopted the $SF_6$ gas-type load break switch for increasing the reliability of distribution network by its superior durability against external environmental condition, in substitution for air-type and oil-type switches. But, it is important to establish the general estimation process for the testing and estimation for long-term reliability. Accordingly, this paper presents the reliability testing method for $SF_6$ gas load break switch which is based on the analysis of the failure mode and the statistics.

  • PDF

Impacts of green technologies in distribution power network

  • Suwanapingkarl, Pasist;Singhasathein, Arnon;Phanthuna, Nattaphong;Boonthienthong, Manat;Srivallop, Kwanchanok;Ketken, Wannipa
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.1
    • /
    • pp.90-100
    • /
    • 2015
  • Green technologies such as renewable energy resources, Electric Vehicles and Plug-in Hybrid Electric Vehicles (EVs/PHEVs), electric locomotives, etc. are continually increasing at the existing power network especially distribution levels, which are Medium Voltage (MV) and Low Voltage (LV). It can be noted that the increasing level of green technologies is driven by the reduction emission policies of carbon dioxide ($CO_2$). The green technologies can affect the quality of power, and hence its impacts of are analysed. In practical, the environment such as wind, solar irradiation, temperature etc. are uncontrollable, and therefore the output power of renewable energy in that area can be varied. Moreover, the technology of the EVs/PHEVs is still developed in order to improve the performance of supply and driving systems. This means that these developed can cause harmonic distortion as the control system is mostly used power electronics. Therefore, this paper aims to analyse the voltage variation and harmonic distortion in distribution power network in urban area in Europe due to the combination between wind turbine, hydro turbine, photovoltaic (PV) system and EVs/PHEVs. More realistic penetration levels of SSDGs and EVs/PHEVs as forecasted for 2020 is used to analyse. The dynamic load demands are also taken into account. In order to ensure the accurate of simulation results, the practical parameters of distribution system are used and the international standards such as Institute of Electrical and Electronics Engineers (IEEE) standards are also complied. The suggestion solutions are also presented. The MATLAB/Simulink software is chosen as it can support complicate modelling and analysis.

Determination of Attenuation Collection Methods According to the Type of Radioactive Waste Drums (방사성폐기물드럼 종류별 감쇠보정방법의 결정)

  • Kwak, Sang-Soo;Choi, Byung-I1;Yoon, Suk-Jung;Lee, Ik-Whan;Kang, Duck-Won;Sung, Ki-Bang
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.309-317
    • /
    • 1997
  • The measured radioactivity of gamma-emitting radionuclides in each radioactive waste drum using the non-destructive waste assay method is underestimated than real radioactivity in radioactive waste drum because the gamma-rays are attenuated within the medium. Therefore, the measured radioactivity should be corrected for the attenuation of gamma-rays. For the correction of the attenuation of gamma-rays, the attenuation correction method should be applied differently by considering the distribution and density of medium in radioactive wastes drum generated from nuclear power plants. In this study, the model drums were fabricated for simulating five types of radioactive waste drums generated from nuclear power plant and the optimum methods of the attenuation correction were experimentally determined to analyze the activity of radionuclides in the waste drum accurately using the segmented gamma scanning system. With the determination of the attenuation correction methods from the experimental results the transmission method and the average density method for the miscellaneous waste drum, the transmission method and the differential peak absorption method for the shielded miscellaneous waste drum were used to measure the density of medium in waste drums. Also, the average density method and the differential peak absorption method for the spent resin drum, the paraffin solidified drum, and the spent filter drum were used.

  • PDF

An Energy-Efficient MAC Protocol for Wireless Wearable Computer Systems

  • Beh, Jounghoon;Hur, Kyeong;Kim, Wooil;Joo, Yang-Ick
    • Journal of information and communication convergence engineering
    • /
    • v.11 no.1
    • /
    • pp.7-11
    • /
    • 2013
  • Wearable computer systems use the wireless universal serial bus (WUSB), which refers to USB technology that is merged with WiMedia physical layer and medium access control layer (PHY/MAC) technical specifications. WUSB can be applied to wireless personal area network (WPAN) applications as well as wired USB applications such as PAN. WUSB specifications have defined high-speed connections between a WUSB host and WUSB devices for compatibility with USB 2.0 specifications. In this paper, we focus on an integrated system with a WUSB over an IEEE 802.15.6 wireless body area network (WBAN) for wireless wearable computer systems. Due to the portable and wearable nature of wearable computer systems, the WUSB over IEEE 802.15.6 hierarchical medium access control (MAC) protocol has to support power saving operations and integrate WUSB transactions with WBAN traffic efficiently. In this paper, we propose a low-power hibernation technique (LHT) for WUSB over IEEE 802.15.6 hierarchical MAC to improve its energy efficiency. Simulation results show that the LHT also integrates WUSB transactions and WBAN traffic efficiently while it achieves high energy efficiency.

A Highly Efficient Multi-Mode Balanced Power Amplifier for W-CDMA Handset Applications (W-CDMA 단말기용 고효율 다중 모드 Balanced 전력증폭기)

  • Kim, Un-Ha;Park, Sung-Hwan;Park, Hong-Jong;Kwon, Young-Woo;Kim, Jung-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.5
    • /
    • pp.606-612
    • /
    • 2012
  • A highly efficient multi-mode balanced power amplifier(PA) structure is proposed for W-CDMA handset applications. The proposed PA has 2-stage amplifier configuration and the stage-bypass and load impedance switching techniques were applied to enhance power efficiency at medium power level as well as low output power level. Using the two techniques, four highly efficient power modes were realized. To demonstrate the usefulness of the proposed structure, a GaAs HBT balanced PA module was designed, fabricated, and measured.

The Product Standard Costs System Constructionby Group and Application of Small and Medium Business (중소기업의 제품그룹별 표준원가시스템 구축 및 활용)

  • Kim, Pan-Soo
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.3
    • /
    • pp.153-168
    • /
    • 2011
  • In medium and small firm, the management system which is simple and where there is a practicality is required Ill)re than the management system which is complicated and minute of the centered around large company so that the introduction of the standard costs can be activated and it can be usefully used as a tool of management decisions. A difference between the standard costs introduction plan proposed in this paper and the preexistance study literature are as follows. In this paper, by breaking from the whole cost accounting aiming at all item, that is the traditional introduction method, and presenting the product cost accounting method by group the standards setting object was minimized and simplified. In this way, if the standards setting object is simplified, it is quick at the perimeter environment change as the little man power and flexibly it corresponds to and the cost information calculation which is exact with the setting up and maintenance of the efficient cost standard becomes available. As a result of applying for real through S corp., the usability of the method that the standard costs introduction method proposed in this paper produced the standard costs relatively short within period, it manages was verified. And the standard costs introduction method proposed in this paper went by the various cost information for each products, the management class did the management will decision which was objective and reasonable in the putting first.

Preliminary Experiments for the Remediation of Trichloroethene-Contaminated Groundwater Using Direct-Current and Zero-Valent Iron (0가 철과 직류전원을 이용한 TCE 오염 지하수의 정화기법 예비조사)

  • Moon, Ji-Won;Moon, Hi-Soo;Roh, Yul;Lee, Suk-Young;Song, Yun-Goo
    • Economic and Environmental Geology
    • /
    • v.34 no.3
    • /
    • pp.307-313
    • /
    • 2001
  • Reactive medium including zero-valent metals such as zero-valent iron ($Fe^0$) degrades chlorinated solvents as a contaminant plume flows through the treatment medium. Although the Feo based reactive barrier has been demonstnlted to be a cost effective for trichloroethenc (TCE)-contaminaled plume remediation, current approach is limited by low process eftlciency and uncertain, effective life of the medium. The objective of this study is to develop an enhanced treatment method of TeE-contaminated groundwater using Feo and direct current. The bench-scale test using flow-through $Fe^0$ reactor column confirmed that the application of direct current with $Fe^0$ is highly effective in enhancing the rate of TeE dechlorination. The dechlorination mechanism appears to be reductive, with the electrons supplied by the iron oxidation and external power supply serving as the additional source of electrons.

  • PDF

Development of Power Supply for Induction Heating System (유도가열용 전원장치 개발)

  • Yoo, D.W.;Oh, S.C.;Kim, Y.H.;Kye, M.H.;Ha, S.U.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.531-536
    • /
    • 1991
  • This paper describes a POWER MOSFET inverter suitable for medium frequency induction heating applications. A series scheme is employed, which is operated at zero phase of the resonant load by PLL control. This ensures maximum power transfer, good efficiency, low EMI noise and reliable operation. Circuit configuration and performance are discussed and design criteria are given. Implementation of a prototype rated at 5KW, $100{\sim}300KHz$ is discribed and experimental results are given.

  • PDF

The Fabrication of Micro-heaters with Low Consumption Power Using SOI and Trench Structures and Its Characteristics (SOI와 트랜치 구조를 이용한 초저소비전력형 미세발열체의 제작과 그 특성)

  • 정귀상;홍석우;이원재;송재성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.3
    • /
    • pp.228-233
    • /
    • 2001
  • This paper presents the optimized design, fabrication and thermal characteristics of micro-heaters for thermal MEMS (micro elelctro mechanical system) applications usign SOI (Si-on-insulator) and trench structures. The micro-heater is based on a thermal measurement principle and contains for thermal isolation regions a 10㎛ thick Si membrane with oxide-filled trenches in the SOI membrane rim. The micro-heater was fabricated with Pt-RTD (resistance thermometer device) on the same substrate by suing MgO as medium layer. The thermal characteristics of the micro-heater wit the SOI membrane is 280$\^{C}$ at input power 0.9W; for the SOI membrane with 10 trenches, it is 580$\^{C}$ due to reduction of the external thermal loss. Therefore, the micro-heater with trenches in SOI membrane rim provides a powerful and versatile alternative technology for improving the performance of micro-thermal sensors and actuators.

  • PDF