• Title/Summary/Keyword: Medicine Code

Search Result 313, Processing Time 0.03 seconds

Benchmark Results of a Monte Carlo Treatment Planning system (몬데카를로 기반 치료계획시스템의 성능평가)

  • Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.149-155
    • /
    • 2002
  • Recent advances in radiation transport algorithms, computer hardware performance, and parallel computing make the clinical use of Monte Carlo based dose calculations possible. To compare the speed and accuracies of dose calculations between different developed codes, a benchmark tests were proposed at the XIIth ICCR (International Conference on the use of Computers in Radiation Therapy, Heidelberg, Germany 2000). A Monte Carlo treatment planning comprised of 28 various Intel Pentium CPUs was implemented for routine clinical use. The purpose of this study was to evaluate the performance of our system using the above benchmark tests. The benchmark procedures are comprised of three parts. a) speed of photon beams dose calculation inside a given phantom of 30.5 cm$\times$39.5 cm $\times$ 30 cm deep and filled with 5 ㎣ voxels within 2% statistical uncertainty. b) speed of electron beams dose calculation inside the same phantom as that of the photon beams. c) accuracy of photon and electron beam calculation inside heterogeneous slab phantom compared with the reference results of EGS4/PRESTA calculation. As results of the speed benchmark tests, it took 5.5 minutes to achieve less than 2% statistical uncertainty for 18 MV photon beams. Though the net calculation for electron beams was an order of faster than the photon beam, the overall calculation time was similar to that of photon beam case due to the overhead time to maintain parallel processing. Since our Monte Carlo code is EGSnrc, which is an improved version of EGS4, the accuracy tests of our system showed, as expected, very good agreement with the reference data. In conclusion, our Monte Carlo treatment planning system shows clinically meaningful results. Though other more efficient codes are developed such like MCDOSE and VMC++, BEAMnrc based on EGSnrc code system may be used for routine clinical Monte Carlo treatment planning in conjunction with clustering technique.

  • PDF

Development of $^{166}Ho$-Stent for the Treatment of Esophageal Cancer (식도암 치료용 $^{166}Ho$-Stent 개발)

  • Park, Kyung-Bae;Kim, Young-Mi;Kim, Kyung-Hwa;Shin, Byung-Chul;Park, Woong-Woo;Han, Kwang-Hee;Chung, Young-Ju;Choi, Sang-Mu;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.62-73
    • /
    • 2000
  • Purpose: Esophageal cancer patients have a difficulty in the intake of meals through the blocked esophageal lumen, which is caused by an ingrowth of cancer cells and largely influences on the prognosis. It is reported that esophageal cancer has a very low survival rate due to the lack of nourishment and immunity as the result of this. In this study a new radioactive stent, which prevents tumor ingrowth and restenosis by additional radiation treatment, has been developed. Materials and Methods: Using ${\ulcorner}HANARO{\lrcorner}$ research reactor, the radioactive stent assembly ($^{166}Ho$-SA) was prepared by covering the metallic stent with a radioactive sleeve by means of a post-irradiation and pre-irradiation methods. Results: Scanning electron microscopy and autoradiography exhibited that the distribution of $^{165/166}Ho\;(NO_3)$ compounds in polyurethane matrix was homogeneous. A geometrical model of the esophagus considering its structural properties, was developed for the computer simulation of energy deposition to the esophageal wall. The dose distributions of $^{166}Ho$-stent were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly on the surface in the form of a cylinder with a diameter of 20 mm and length of 40 mm. As an animal experiment, when radioactive stent developed in this study was inserted into the esophagus of a Mongrel dog, tissue destruction and widening of the esophageal lumen were observed. Conclusion: We have developed a new radioactive stent comprising of a radioactive tubular sleeve covering the metallic stent, which emits homogeneous radiation. If it is inserted into the blocked or narrowed lumen, it can lead to local destruction of the tumor due to irradiation effect with dilatation resulting from self-expansion of the metallic property. Accordingly, it is expected that restenosis esophageal lumen by the continuous ingrowth and infiltration of cancer after insertion of our radioactive stent will be decreased remarkably.

  • PDF

Antigenic localities in the tissued of Metagonimus yokogawai observed by immunogoldlabeling method (면역황금 표식법을 이용한 요꼬가와흡충의 조직내 항원성 부위에 관한 연구)

  • Ahn, Hyuk;Rim, Han-Jong;Kim, Soo-Jin
    • Parasites, Hosts and Diseases
    • /
    • v.29 no.3
    • /
    • pp.245-258
    • /
    • 1991
  • In order to determine the antigenic localization in the tissues of the adult Metagonimus yokegawai, immunogoldlabeling method was applied using serum immunoglobulins (IgG) of cats which were infected with isolated metacercariae from Plecoglossus altivelis. The sectioned worm tissue was embedded in Lowicryl HM 20 medium and stained with infected serum IgG and protein A gold complex (particle size: 12 nm) , It was observed by electron microscopy at each tissue of the worm. The gold particles were observed on the tegumental syncytium as well as cytoplasm of tegumental cells and epithelial lamella of the caecum. The gold particles were not observed on the basal lamina of the tegument, interstitial matrix of the parenchyma, the muscle tissue and mitochondria of the tegument. The gold particles were specifically labeled in the secretory granules in the vitelline cells. They were also labeled on the lumen of bladder and egg shell. The above findings showed that antigenic materials in the tissue of adult worms were specifically concentrated on the tegumental syncytium as well as cytoplasm of tegumental cells and epithelial lamella of the caecum.

  • PDF

Survey of Multi Residual Pesticides in Materials of Korean Traditional Herbal Tea (한방차 원료의 잔류농약 조사연구)

  • Kim, Nan-Young;Kim, Young-Sug;Kim, Myung-Gil;Jung, Hong-Rae;Kim, Yun-Sung;Kim, Han-Taek;Lee, Sun-Woo;Chae, Kyeng-Suk;Yoon, Mi-Hye
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.1
    • /
    • pp.28-34
    • /
    • 2012
  • We analysed 149 samples of Korean traditional herbal tea materials. The 156 pesticides were analyzed by GC/ECD and NPD, detected pesticides were confirmed by GC-TOF/MS. Sample preparation was performed bv multi-residue analysis method of multiclass pesticides of the Korea Food Code. The residual pesticides were detected in 22 samples(14.8%), the highest detection frequency samples are lycium and jujube. Detected pesticides in Korean traditional herbal tea materials were chlorpyrifos (5 samples), chlorothalonil (3 samples), cypermethrin (3 samples), hexaconazol (3 samples) and cyhalothrin(3 samples). The pesticide types detected in Korean traditional herbal tea materials were organophosphorus(29.2%), pyrethroids(16.7%), organochlorines (12.5%) and triazoles(12.5%). The 5 samples(lycium, jujube, chrysanthemum, balloon-flower, milk vetch root) were detected pesticides below MRLs, 2 samples(cornus fruit, cnidium) were detected pesticides unnotificated MRLs.

Ethical Argumants and Problems Analysis Related to Induced Abortion (인공임신중절과 관련된 윤리학적 논쟁과 문제 분석)

  • Um, Young-Rhan
    • Women's Health Nursing
    • /
    • v.2 no.2
    • /
    • pp.230-252
    • /
    • 1996
  • Over one million cases of the induced abortion have been conducted annually in Korea. Among those cases, most of all were illegally done, but this has not been addressed in the literature. While Korean Nurse Association Code of Ethics presents the respect for life as one of the basic ideology, it was not dealt enough in nursing education. The purposes of the study were to activate the debate on the issues related to an induced abortion ; to introduce the related ethical theories ; and to seek the solution of the ethical problems, which will eventually result in establishing the morality of nursing practice. The ethical theories of an induced abortion have traditionally addressed two extreme perspectives ; the conservatives who emphasize the sanctity of human life and the right of life that will never ethically allow the killing fetus ; and the liberalists who insist the right to choice for women to control their body. Since these extreme theories has not been helpful to solve the ethical problems, the recent trend is leading to the modified theories both from conservative and liberal perspectives. The examples of the theories are the potentiality of fetus(Singer, 1993), the obligation of women to serve their body to fetus(Held, 1987), the Replacement theory (Callahan, 1987), and the Principle of Caring (Gilligan, 1982). The study conducted the indepth interviews with 17 women who experienced the induced abortion and the 6 cases were selected to be analyzed. The cases were analyzed and interpreted by using an integrated case method which was combined of the New Casuisty(Jonsen & Toulmin, 1988 ; Jonsen, 1991) and the Specified Principlism (Richardson, 1990 ; Degrazia, 1992). The result of analysis revealed three types of ethical problems ; (1) the responsibility of taking care of the baby to be born (2) the fear for the condition of the fetus, and (3) the choice of induced abortion as the method of birth control. The findings also revealed the related ethical principles for various situations ; the principle of caring was used for choosing an induced abortion by the subjects ; the principles of the potentiality of fetus and the obligation of women to serve their body were for the consideration for the life of fetus ; and the principle of replacement was utilized for the right to choice for women. The ethical principles related to an induced abortion introduced in the study provided the way to solve the moral problems by applying to the clinical situations for nurses. The study also revealed the possibility of modifying the current ethical theories from the method of applying the principles to the various situation in the study. The modified theories would be more useful to guide the clinical practice with similar ethical problems.

  • PDF

Comparison of Three Methods Assessing the Ergonomic Risks of Manual Lifting Tasks at Ship Engine Manufacturing Facilities (선박용 엔진 제조업 들기작업의 인간공학적 위험 평가를 위한 세 가지 방법 비교)

  • Kim, Sun Ja;Shin, Yong Chul;Kim, Boo Wook;Kim, Hyun Dong;Woo, Ji Hoon;Kang, Dongmug;Lee, Hyun Seok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.104-113
    • /
    • 2005
  • A variety of ergonomic assessment methods of lifting tasks known as a major cause of work-related lower back pain have been used. But there is a limited information in choosing the most appropriate assessment method for a particular job and in finding out strengths and weakness of the methods. The purpose of this study was to assess and compare the ergonomic risks of lifting tasks in a marine diesel engine production industry by three lifting ergonomic assessment tools widely used: the National Institute for Occupational Safety and Health(NIOSH) Revised Lifting Equation(NLE), the Washington Administrative Code 296-62-0517(WAC), and the Snook Tables. Lifting index(weight of load/Recommended Weight Limit) of NLE($LI_{NLE}$) was above 1 at 34 tasks(75.6%) of a total number of 45 lifting tasks. LI of WAC($LI_{WAC}$) was above 1 at 11 tasks(24.4 %). LI of Snook Table($LI_{Snook}$) was above 1 at 29 tasks(64.4%). Thus, LI was high in orders of $LI_{NLE}$ > $LI_{Snook}$ > $LI_{WAC}$. There were significantly high correlations among three Lls(p<0.01). The correlation coefficients between $LI_{NLE}$and the other three Lls($LI_{WAC}$ and $LI_{Snook}$) were r=0.93 and r=0.88, respectively. The linear regression equations were y = 0.444x + 0.11(r=0.93) between $LI_{NLE}$ and $LI_{WAC}$, y = 0.93x + 0.008(r=0.88) between LI(NLE) and $LI_{Snook}$. The LI values by WAC was significantly lower than those by the other tools. The compared features, strength and limitation among these tools were described in this paper.

Conceptual Source Design and Dosimetric Feasibility Study for Intravascular Treatment: A Proposal for Intensity Modulated Brachytherapy (혈관내 방사선치료를 위한 이론적 선원 설계 및 선량적 관점에서의 적합성 연구: 출력변조를 이용한 근접치료에 대한 제안)

  • Kim Siyong;Han Eunyoung;Palta Jatinder R.;Ha Sung W.
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.158-166
    • /
    • 2003
  • Purpose: To propose a conceptual design of a novel source for intensity modulated brachytherapy. Materials and Methods: The source design incorporates both radioactive and shielding materials (stainless steel or tungsten), to provide an asymmetric dose intensity in the azimuthal direction. The intensity modulated intravascular brachytherapy was performed by combining a series of dwell positions and times, distributed along the azimuthal coordinates. Two simple designs for the beta-emitting sources, with similar physical dimensions to a $^{90}Sr/Y$ Novoste Beat-Cath source, were considered in the dosimetric feasibility study. In the first design, the radioactive and materials each occupy half of the cylinder and in the second, the radioactive material occupies only a quater of the cylinder. The radial and azimuthal dose distributions around each source were calculated using the MCNP Monte Carlo code. Results: The preliminary hypothetical simulation and optimization results demonstrated the 87$\%$ difference between the maximum and minimum doses to the lumen wall, due to off-centering of the radiation source, could be reduced to less than 7$\%$ by optimizing the azimuthal dwell positions and times of the partially shielded intravascular brachytherapy sources. Conclusion: The novel brachytherapy source design, and conceptual source delivery system, proposed in this study show promising dosimetric characteristics for the realization of intensity modulated brachytherapy in intravascular treatment. Further development of this concept will center on building a delivery system that can precisely control the angular motion of a radiation source in a small-diameter catheter.

A Survey of the Presence of Aflatoxins in Herb Medicines (한약재중의 아플라톡신 오염도 조사)

  • Park, Sung-Kyu;Jang, Jung-Im;Ha, Kwang-Tae;Kim, Sung-Dan;Kim, Ouk-Hee;Choi, Younh-Hee;Seung, Hyun-Jeung;Kim, Si-Jung;Lee, Kyeong-Ah;Jo, Han-Bin;Choi, Byung-Hyum;Kim, Min-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.2
    • /
    • pp.169-173
    • /
    • 2009
  • A survey of total aflatoxin levels was conducted on 145 samples(carthamiflos, thujae semen, giycyrrhizae radix et rhizoma) collected in Yakyeang markets in Seoul. Aflatoxin levels were quantified by the immunoaffinity column clean-up method followed by performance liguid chromatography(HPLC)-fluorescence detector(FLD). Aflatoxins were found in 10(6.9%)samples including 5 Arecae semen, 4 Thujae semen, 1 Zizyphi semen with a range of $0.45{\sim}79.15\;{\mu}g/kg$. Generally These results show that the contamination level of aflatoxins in Herb Medicines consumed in Korea is high compared with the standard in Korea Herb Medicine Code($10\;{\mu}g/kg$ as aflatoxin B1). It is considered that aflatoxin concentration was increased in herb medicines during a storage and drying in herb medicines examined

Evaluation of Real-time Target Positioning Accuracy in Spinal Radiosurgery (척추방사선수술시 실시간 추적검사에 의한 병소목표점 위치변이 평가)

  • Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.290-294
    • /
    • 2013
  • Stereotactic Radiosurgery require high accuracy and precision of patient positioning and target localization. We evaluate the real time positioning accuracy of isocenter using optic guided patient positioning system, ExacTrac (BrainLab, Germany), during spinal radiosurgery procedure. The system is based on real time detect multiple body markers attached on the selected patient skin landmarks. And a custom designed patient positioning verification tool (PPVT) was used to check the patient alignment and correct the patient repositioning before radiosurgery. In this study, We investigate the selected 8 metastatic spinal tumor cases. All type of tumors commonly closed to thoracic spinal code. To evaluate the isocenter positioning, real time patient alignment and positioning monitoring was carried out for comparing the current 3-dimensional position of markers with those of an initial reference positions. For a selected patient case, we have check the isocenter positioning per every 20 millisecond for 45 seconds during spinal radiosurgery. In this study, real time average isocenter positioning translation were $0.07{\pm}0.17$ mm, $0.11{\pm}0.18$ mm, $0.13{\pm}0.26$ mm, and $0.20{\pm}0.37$ mm in the x (lateral), y (longitudinal), z (vertical) directions and mean spatial error, respectively. And body rotations were $0.14{\pm}0.07^{\circ}$, $0.11{\pm}0.07^{\circ}$, $0.03{\pm}0.04^{\circ}$ in longitudinal, lateral, table directions and mean body rotation $0.20{\pm}0.11^{\circ}$, respectively. In this study, the maximum mean deviation of real time isocenter positioning translation during spinal radiosurgery was acceptable accuracy clinically.

Software development for the visualization of brain fiber tract by using 24-bit color coding in diffusion tensor image

  • Oh, Jung-Su;Song, In-Chan;Ik hwan Cho;Kim, Jong-Hyo;Chang, Kee-Hyun;Park, Kwang-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.133-133
    • /
    • 2002
  • Purpose: The purpose of paper is to implement software to visualize brain fiber tract using a 24-bit color coding scheme and to test its feasibility. Materials and Methods: MR imaging was performed on GE 1.5 T Signa scanner. For diffusion tensor image, we used a single shot spin-echo EPI sequence with 7 non-colinear pulsed-field gradient directions: (x, y, z):(1,1,0),(-1,1,0),(1,0,1),(-1,0,1),(0,1,1),(0,1,-1) and without diffusion gradient. B-factor was 500 sec/$\textrm{mm}^2$. Acquisition parameters are as follows: TUTE=10000ms/99ms, FOV=240mm, matrix=128${\times}$128, slice thickness/gap=6mm/0mm, total slice number=30. Subjects consisted of 10 normal young volunteers (age:21∼26 yrs, 5 men, 5 women). All DTI images were smoothed with Gaussian kernel with the FWHM of 2 pixels. Color coding schemes for visualization of directional information was as follows. HSV(Hue, Saturation, Value) color system is appropriate for assigning RGB(Red, Green, and Blue) value for every different directions because of its volumetric directional expression. Each of HSV are assigned due to (r,$\theta$,${\Phi}$) in spherical coordinate. HSV calculated by this way can be transformed into RGB color system by general HSV to RGB conversion formula. Symmetry schemes: It is natural to code the antipodal direction to be same color(antipodal symmetry). So even with no symmetry scheme, the antipodal symmetry must be included. With no symmetry scheme, we can assign every different colors for every different orientation.(H =${\Phi}$, S=2$\theta$/$\pi$, V=λw, where λw is anisotropy). But that may assign very discontinuous color even between adjacent yokels. On the other hand, Full symmetry or absolute value scheme includes symmetry for 180$^{\circ}$ rotation about xy-plane of color coordinate (rotational symmetry) and for both hemisphere (mirror symmetry). In absolute value scheme, each of RGB value can be expressed as follows. R=λw|Vx|, G=λw|Vy|, B=λw|Vz|, where (Vx, Vy, Vz) is eigenvector corresponding to the largest eigenvalue of diffusion tensor. With applying full symmetry or absolute value scheme, we can get more continuous color coding at the expense of coding same color for symmetric direction. For better visualization of fiber tract directions, Gamma and brightness correction had done. All of these implementations were done on the IDL 5.4 platform.

  • PDF