• Title/Summary/Keyword: Medical visualization

Search Result 323, Processing Time 0.028 seconds

Arthroscopic Removal of Loose Bodies from the Knee (관절경을 이용한 슬관절 유리체 제거술)

  • Ahn, Jin Hwan;Ha, Chul Won;Hwang, Tae Kyu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.2
    • /
    • pp.155-158
    • /
    • 1998
  • The purpose of this study is to evaluate the cause, size, number, nature and locaton of loose bodies in the knee joint and to describe the proper arthroscopic technique to remae the loose bodies according to the location of them. We retrospectively analysed thirty-three operations of arthroscopic removal of loose bodies from the knee. Eleven males and 22 females were included with average age of 38(range 7-71). Total number of removed loose bodies were more than sixty. The loose bodies were found most commonly at anterior intercondylar notch area. The most common associated pathology was degenerative arthritis. The most common size of loose bodies was in the range of 5mm to 10mm in diameter. The most common nature of loose bodies was osteochondral. The loose bodies located in suprapatellar pouch, medial gutter, lateral gutter. anterior intercondylar notch or posterior intercondylar notch were removed using standard portals such as anteromedial, anterolateral, superomedial and posteromedial portals. The removal of loose bodies located in upper portion of posteromedial or posterolateral compartment were greatly enhanced using posterior trans-septal portal. The proper portals for the visualization and removal of loose bodies were identified according to the location of loose bodies in the knee joint. More skill in the use of the arthroscope is required for the removal of loose bodies than for simple diagnostic arthroscopy.

  • PDF

Development of Prototype for Screening Anti-Inflammation Effects concerning p38 MAPK Signal Pathway (p38 MAPK을 이용한 항염증 효능 규명 프로토타입 개발)

  • Kim, Chul;Yae, Sang-Jun;Nam, Ky-Youb;Kim, Sang-Kyun;Jang, Hyun-Chul;Kim, Jin-Hyun;Kim, Young-Eun;Song, Mi-Young
    • Korean Journal of Oriental Medicine
    • /
    • v.17 no.3
    • /
    • pp.77-85
    • /
    • 2011
  • Objectives : The purpose of this study was to develop a simulator which can analyze the anti-inflammatory effects of medical herbs based on e-cell concerning p38 MAPK signal pathway. Methods : We collected data concerning medical herbs with anti-inflammatory effects and the active compounds to provide as a fundamental databse and to validate the newly developed algorithm. At this time, we used the target database as pubmed and gathered the data by data mining tool, pathway studio. Also we have developed the web-based search system for confirming database related to anti-inflammation. We researched the mechanism of actions of proteins in p38 MAPK signal pathway when active compound has been inserted into the network. We reduced total network into TAK-MKK3-p38 and made the two types of mathematical model about active compounds' interaction. Results & Conclusion : We constructed the database which have 69 cases of medical herbs, 71 cases of active compounds, about 8,000 cases of URL(Uniform Resource Locator) related to papers and reports. We designed the ordinary differential equations for response of TAK, MKK3, p38 in e-cell's cytosol and nucleus. We used this formular as measure whether an active compound of medicinal plants which is inputted by an user would have an anti-inflammation effects. We developed the visualization program which could show the change of concentration over time.

Realistic and Fast Depth-of-Field Rendering in Direct Volume Rendering (직접 볼륨 렌더링에서 사실적인 고속 피사계 심도 렌더링)

  • Kang, Jiseon;Lee, Jeongjin;Shin, Yeong-Gil;Kim, Bohyoung
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.15 no.5
    • /
    • pp.75-83
    • /
    • 2019
  • Direct volume rendering is a widely used method for visualizing three-dimensional volume data such as medical images. This paper proposes a method for applying depth-of-field effects to volume ray-casting to enable more realistic depth-of-filed rendering in direct volume rendering. The proposed method exploits a camera model based on the human perceptual model and can obtain realistic images with a limited number of rays using jittered lens sampling. It also enables interactive exploration of volume data by on-the-fly calculating depth-of-field in the GPU pipeline without preprocessing. In the experiment with various data including medical images, we demonstrated that depth-of-field images with better depth perception were generated 2.6 to 4 times faster than the conventional method.

Relationship between emotions and emoticons in adolescents in digital communication environment (디지털 커뮤니케이션 환경에서 청소년들의 감정과 이모티콘의 관계)

  • Kim, Yoon-Ji;Kang, Dongmug;Kim, Ju-Young;Kim, Jong-Eun
    • Health Communication
    • /
    • v.12 no.1
    • /
    • pp.51-72
    • /
    • 2017
  • Purpose: Adolescents use emoticons to express their emotions in an online environment. Hence, medical experts can understand the emotions of adolescents by emoticons. The goal of this study was to investigate the relationship between various emotions and emoticons among the Korean adolescents. Methods: The questionnaire survey was conducted between September 1 and 30, 2014, involving 3,272 students in elementary schools, middle schools, and high schools affiliated in the Department of Education of the metropolitan city of Busan. A total of 1,717 students responded to the survey. The participants consisted of 806 males (46.9%), and 911 females (53.1%). Among these, there were 557 elementary school students (32.4%), 617 middle school students (35.9%), and 543 high school students (31.6%). A social networking analysis was conducted using NodeXL. Results: The frequency of emoticon use among adolescents runs in the order of joy, sadness, fear, surprise, anger, disgust, and then depression. Elementary school females mainly use emoticons to express joy; middle school females use emoticons to express sadness, surprise, anger, disgust, and depression; and high school females use emoticons to express fear. Age- and gender-specific emoticon networks were visualized by using the Haren-Korel fast multiscale algorithm. Commonly used emoticons by age and gender were expressed in the networks. Results of age- and gender-specific emoticon networks visualization show similar results of centrality of seven emoticons. Conclusion: In the digital communication environment, emoticons could be used to catch the emotions of adolescents in Korea.

Integrated Power Optimization with Battery Friendly Algorithm in Wireless Capsule Endoscopy

  • Mehmood, Tariq;Naeem, Nadeem;Parveen, Sajida
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.11
    • /
    • pp.338-344
    • /
    • 2021
  • The recently continuous enhancement and development in the biomedical side for the betterment of human life. The Wireless Body Area Networks is a significant tool for the current researcher to design and transfer data with greater data rates among the sensors and sensor nodes for biomedical applications. The core area for research in WBANs is power efficiency, battery-driven devices for health and medical, the Charging limitation is a major and serious problem for the WBANs.this research work is proposed to find out the optimal solution for battery-friendly technology. In this research we have addressed the solution to increasing the battery lifetime with variable data transmission rates from medical equipment as Wireless Endoscopy Capsules, this device will analyze a patient's inner body gastrointestinal tract by capturing images and visualization at the workstation. The second major issue is that the Wireless Endoscopy Capsule based systems are currently not used for clinical applications due to their low data rate as well as low resolution and limited battery lifetime, in case of these devices are more enhanced in these cases it will be the best solution for the medical applications. The main objective of this research is to power optimization by reducing the power consumption of the battery in the Wireless Endoscopy Capsule to make it battery-friendly. To overcome the problem we have proposed the algorithm for "Battery Friendly Algorithm" and we have compared the different frame rates of buffer sizes for Transmissions. The proposed Battery Friendly Algorithm is to send the images on average frame rate instead of transmitting the images on maximum or minimum frame rates. The proposed algorithm extends the battery lifetime in comparison with the previous baseline proposed algorithm as well as increased the battery lifetime of the capsule.

Affordance Elements According to the Usability of the Interface of Immersive Virtual Reality Clinical Skill Content (몰입형 가상현실 의료 술기 콘텐츠의 인터페이스 사용성에 따른 어포던스 하위 평가 요소에 관한 연구)

  • Hwang, Hyo-Hyon;Choi, Yoo-Mi
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.6
    • /
    • pp.307-318
    • /
    • 2022
  • Virtual reality is actively used in the medical field as a learning effectiveness that induces immersion, but research on the factors that induce learning immersion is insufficient. Therefore, this study extracted the usability and cognitive affordance evaluation elements of the interface through literature research and selected four types of virtual reality medical contents to conduct a Useability-Test for experts. Based on this, an interface design method according to virtual reality medical technology content was proposed. In summary, it can be seen that the information-providing interface affects immersion due to visibility, distance from the experience's gaze, color harmony, uniform visualization, feedback, reaction speed, and expected changes resulting from manipulation, and does not impair immersion. This study has limitations in generalization using limited content, so it is expected that continuous research will discuss the development of standardized guides in interface design and the precision of interface design research from a user perspective.

Rapid Detection of Streptococcus mutans Using an Integrated Microfluidic System with Loop-Mediated Isothermal Amplification

  • Jingfu Wang;Jingyi Wang;Xin Chang;Jin Shang;Yuehui Wang;Qin Ma;Liangliang Shen
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.8
    • /
    • pp.1101-1110
    • /
    • 2023
  • Streptococcus mutans is the primary causative agent of caries, which is one of the most common human diseases. Thus, rapid and early detection of cariogenic bacteria is critical for its prevention. This study investigated the combination of loop-mediated isothermal amplification (LAMP) and microfluid technology to quantitatively detect S. mutans. A low-cost, rapid microfluidic chip using LAMP technology was developed to amplify and detect bacteria at 2.2-2.2 × 106 colony-forming units (CFU)/ml and its detection limits were compared to those of standard polymerase chain reaction. A visualization system was established to quantitatively determine the experimental results, and a functional relationship between the bacterial concentration and quantitative results was established. The detection limit of S. mutans using this microfluidic chip was 2.2 CFU/ml, which was lower than that of the standard approach. After quantification, the experimental results showed a good linear relationship with the concentration of S. mutans, thereby confirming the effectiveness and accuracy of the custom-made integrated LAMP microfluidic system for the detection of S. mutans. The microfluidic system described herein may represent a promising simple detection method for the specific and rapid testing of individuals at risk of caries.

Clinical Feasibility of Video-assisted Thoracic Surgery for Thoracic Trauma (흉부외상 치료에서의 비디오 흉강경 수술의 유용성)

  • Kang, Do-Kyun;Kim, Hyeong-Ryul;Kim, Yong-Hee;Kim, Dong-Kwan;Park, Seung-Il
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.170-174
    • /
    • 2010
  • Purpose: As techniques and instruments for video-assisted thoracic surgery (VATS) have been evolving, attempts to perform VATS for chest trauma have been increasing. Several studies have demonstrated the feasibility and safety of VATS for thoracic trauma. We reviewed our experience to evaluate the clinical feasibility and safety of VATS for thoracic trauma. Methods: Fifty-two patients underwent thoracic surgery for chest trauma in Asan Medical Center from January 1990 to December 2009. VATS was performed in 21 patients who showed stable vital signs. We reviewed retrospectively the medical records of those patients to investigate the results of VATS for thoracic trauma. Results: Thoracic exploration for chest trauma was performed in 52 patients. There were 46 males (88.5%) and 6 females (11.5%). The median age was 46.0 years (range: 11~81 years). There were 39 blunt and 13 penetrating traumas. A standard posterolateral thoracotomy was performed in 31 patients, and VATS was tried in 21 patients. We performed successful VATS in 13 patients; 11 males (84.5%) and 2 females (15.5%) with a median age of 46.0 years (range: 24~75 years). The indication of VATS was persistent intrathoracic hemorrhage in 10 patients and clotted hemothorax in 3 patients. There were no complications, but there were two mortalities due to multiple organ failure after massive transfusion. In 8 patients, VATS was converted to a standard posterolateral thoracotomy for several reasons. The reason was inadequate visualization for bleeding control or evacuation of the hematoma in 5 patients. In 3 patients, VATS was performed to evaluate diaphragmatic injury. After the diaphragmatic injury had been confirmed, a standard posterolateral thoracotomy was performed to repair the diaphragm. Conclusion: VATS should be safe and efficient method for diagnostic evaluation and surgical management of stable patients with thoracic trauma.

Study on a Methodology for Developing Shanghanlun Ontology (상한론(傷寒論)온톨로지 구축 방법론 연구)

  • Jung, Tae-Young;Kim, Hee-Yeol;Park, Jong-Hyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.5
    • /
    • pp.765-772
    • /
    • 2011
  • Knowledge which is represented by formal logic are widely used in many domains such like artificial intelligence, information retrieval, e-commerce and so on. And for medical field, medical documentary records retrieval, information systems in hospitals, medical data sharing, remote treatment and expert systems need knowledge representation technology. To retrieve information intellectually and provide advanced information services, systematically controlled mechanism is needed to represent and share knowledge. Importantly, medical expert's knowledge should be represented in a form that is understandable to computers and also to humans to be applied to the medical information system supporting decision making. And it should have a suitable and efficient structure for its own purposes including reasoning, extendability of knowledge, management of data, accuracy of expressions, diversity, and so on. we call it ontology which can be processed with machines. We can use the ontology to represent traditional medicine knowledge in structured and systematic way with visualization, then also it can also be used education materials. Hence, the authors developed an Shanghanlun ontology by way of showing an example, so that we suggested a methodology for ontology development and also a model to structure the traditional medical knowledge. And this result can be used for student to learn Shanghanlun by graphical representation of it's knowledge. We analyzed the text of Shanghanlun to construct relational database including it's original text, symptoms and herb formulars. And then we classified the terms following some criterion, confirmed the structure of the ontology to describe semantic relations between the terms, especially we developed the ontology considering visual representation. The ontology developed in this study provides database showing fomulas, herbs, symptoms, the name of diseases and the text written in Shanghanlun. It's easy to retrieve contents by their semantic relations so that it is convenient to search knowledge of Shanghanlun and to learn it. It can display the related concepts by searching terms and provides expanded information with a simple click. It has some limitations such as standardization problems, short coverage of pattern(證), and error in chinese characters input. But we believe this research can be used for basic foundation to make traditional medicine more structural and systematic, to develop application softwares, and also to applied it in Shanghanlun educations.

Daily localization of partial breast irradiation patients with three-dimensional ultrasound imaging

  • Sayan, Mutlay;Vergalasova, Irina;Hard, Daphne;Wrigth, Heather;Archambault, Jessica;Gagne, Havaleh;Nelson, Carl;Heimann, Ruth
    • Radiation Oncology Journal
    • /
    • v.37 no.4
    • /
    • pp.259-264
    • /
    • 2019
  • Purpose: Accurate localization of the lumpectomy cavity during accelerated partial breast radiation (APBR) is essential for daily setup to ensure the prescribed dose encompasses the target and avoids unnecessary irradiation to surrounding normal tissues. Three-dimensional ultrasound (3D-US) allows direct visualization of the lumpectomy cavity without additional radiation exposure. The purpose of this study was to evaluate the feasibility of 3D-US in daily target localization for APBR. Materials and methods: Forty-seven patients with stage I breast cancer who underwent breast conserving surgery were treated with a 2-week course of APBR. Patients with visible lumpectomy cavities on high quality 3D-US images were included in this analysis. Prior to each treatment, X-ray and 3D-US images were acquired and compared to images from simulation to confirm accurate position and determine shifts. Volume change of the lumpectomy cavity was determined daily with 3D-US. Results: A total of 118 images of each modality from 12 eligible patients were analyzed. The average change in cavity volume was 7.8% (range, -24.1% to 14.4%) on 3D-US from simulation to the end-of-treatment. Based on 3D-US, significantly larger shifts were necessary compared to portal films in all three dimensions: anterior/posterior (p = 7E-11), left/right (p = 0.002), and superior/inferior (p = 0.004). Conclusion: Given that the lumpectomy cavity is not directly visible via X-ray images, accurate positioning may not be fully achieved by X-ray images. Therefore, when the lumpectomy cavity is visible on US, 3D-US can be considered as an alternative to X-ray imaging during daily positioning for selected patients treated with APBR, thus avoiding additional exposure to ionizing radiation.