• 제목/요약/키워드: Medical radioactive isotope

검색결과 34건 처리시간 0.022초

Evaluation of exposure to ionizing radiation of medical staff performing procedures with glucose labeled with radioactive fluorine - 18F-FDG

  • Michal Biegala;Marcin Brodecki;Teresa Jakubowska;Joanna Domienik-Andrzejewska
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.335-339
    • /
    • 2024
  • Employees of nuclear medicine facilities performing medical procedures with the use of open radioactive sources require continuous detailed control of exposure to ionizing radiation. Thermoluminescent (TL) detectors placed in dosimeters: for the whole body, for lenses, ring and wrist dosimeters were used to assess exposure. The highest whole-body exposure of (1.70 ± 1.09) µSv/GBq was recorded in nurses administering radiopharmaceutical to patients. The highest exposure to lenses and fingers was recorded for employees of the quality control zone and it was (8.08 ± 2.84) µSv/GBq and a maximum of (1261.46 ± 338.93) µSv/GBq, respectively. Workers in the production zone received the highest doses on their hands, i.e. (175.67 ± 13.25) µSv/GBq. The measurements performed showed that the analyzed workers may be classified as exposure category A. Wrist dosimeters are not recommended for use in isotope laboratories due to underestimation of ionizing radiation doses. Appropriately selected shields, which significantly reduce the dose received by employees, must be used in isotope laboratories. Periodic measurements confirmed that the appropriate optimization of exposure reduces the radiation doses received by employees.

14C-아세트아미노펜 비임상시험을 통한 생체시료 분석용 가속질량분석기의 검증 (Non-clinical Trials using 14C-Acetaminophen to Validate Biomedical Accelerator Mass Spectrometry System)

  • 송진호;심재훈;박정배;여창수;배수현;최민선;권미혜;김경민
    • 방사선산업학회지
    • /
    • 제17권2호
    • /
    • pp.127-134
    • /
    • 2023
  • Pharmacokinetic (PK) data provide pivotal information in drug development, and they are usually first studied in the preclinical stage using various animals. However, quite often, animal PK data may not match with human PK, especially in metabolites. Thus, most regulatory agencies in the world make it mandatory to obtain metabolite information using 14C radiolabeled drug in human for small molecule drug candidates. However, such studies are expensive and time consuming and they are usually done at the end of Phase II trials using ~3.7 MBq of 14C labeled drug in a limited number of human subjects. Introduction of accelerator mass spectrometry (AMS) in this kind of study has revolutionized it. Since AMS can measure 14C level as close as natural abundance, it can quantify the amounts of 14C labeled drugs and their metabolites produced in human body that consumes less than the amount of 0.0037 MBq of 14C labeled drug, a very safe level of radioactive dose in human. Therefore, it is now possible to conduct human 14C studies safely in early clinical trials without spending hefty amount of money and time. Korea Radioisotope Center for Pharmaceuticals(KRICP) at Korea Institute of Biological and Medical Sciences(KIRAMS) has established an AMS facility in 2018, housing a 0.5MV AMS manufactured at the US National Electrostatics Corps (NEC). The AMS instrument has been validated using various standard samples that have been prepared at Lawrence Livermore National Laboratory in the US, a worldly reputable provider of AMS standards. In this paper, we present a mass balance study for acetaminophen in rats using AMS and prove that the study results are equivalent with those of literature, which shows the AMS facilities at KRICP has successfully installed and be ready to be used in the various PK studies using 14C labelled compounds for new drug development.

방사선 피폭역을 달리하여 분리한 세균의 방사선감수성 비교 (Comparison of Radiosensitivity of Bacteria Isolated from Given Radiation Exposure History)

  • 김기수;민봉희;이강순
    • 미생물학회지
    • /
    • 제12권2호
    • /
    • pp.67-76
    • /
    • 1974
  • This experiment was carried out to identify and to compare the radiosensitivities of bacteriz isolated from the sources of different radiation exposure histories. Among 10 strains isolated in this investigation, 4 strains of bacteria, Bacillus firmus, Bacillus brevis, Baciilus subtilis and Bacillus sphaericus were isolated from high and low radioactive sites simulaneously. Bacterial strains isolated from radioactive sources such as reactor and isotope production rooms were more resistant to irradiation than the microganisms from medical products and laboratories, however, there was no significance in radiosensitivity in the same species of bacteriz, even if they were isolated from different radiation exposure histories.

  • PDF

체내대사를 이용한 핵의학적 검사의 선량률 저감에 관한 연구 (Study in vivo metabolism using nuclear medical examination of the dose rate reduction)

  • 강용길;나수경;홍진웅;이귀원;김낙상
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.75-81
    • /
    • 2012
  • The purpose of this study was administered to the body for examination and treatment, high-energy radioactive isotope(F-18, I-131) in vitro discharge experiments. Increasing exposed dose of radiation to health professionals is caused by the increase of PET/CT use and a radioactive isotope. Therefore, the high-energy isotope F-18 and I-131 after administration about using Metabolite excretion was studied. As a results of this study, patients had plenty of fluids for testing and treatment alone administered radiopharmaceuticals can be more than twice as fast excretion induced emissions. Also was able to get a better image space to reduce the dose rate.

  • PDF

Evaluation of 18F Radioactive Concentration in Exhaust at Cyclotron Facility at Chosun University

  • Jeong, Cheol-ki;Jang, Han;Lee, Goung-jin
    • 방사선산업학회지
    • /
    • 제10권1호
    • /
    • pp.37-41
    • /
    • 2016
  • The recent prevalence of PET examinations in Korea has led to an increase in the number of cyclotrons. The medical isotope $^{18}F$ produced in most cyclotron facilities currently operating in Korea is emitted into the environment during the production of [$^{18}F$]FDG, a cancerdiagnosis reagent. The amount of [$^{18}F$]FDG synthesized determines the radioactive concentration of $^{18}F$ in the exhaust. At some facilities, this amount temporarily exceeds the emission limit. In this study, we evaluated the $^{18}F$ radioactivity concentration in the exhaust from the cyclotron facility at Chosun University. The $^{18}F$ radioactivity concentration was measured using an air sampler and a HPGe semiconductor detector. The measurements showed that the radioactive concentration of $^{18}F$ in the exhaust at the cyclotron facility at Chosun University was the highest during [$^{18}F$]FDG synthesis but remained under the legal limit of $2,000Bq\;m^{-3}$.

MCNPX 코드를 이용한 의료용 방사성동위원소 생산을 위한 가속기 시설의 방사선차폐 및 선량 계산 (Shielding Calculations of Accelerator Facility for Medical Isotope Production using MCNPX Code)

  • 서규석;김찬형
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.210-214
    • /
    • 2004
  • PET에 사용되는 조영제는 생산과정 중에 다량의 중성자가 발생한다. 발생된 중성자는 주로 콘크리트 구조물로 차폐를 하게 되며 가속기 시설의 차폐 평가는 구조물 외부로 방출되는 방사선의 선량을 측정하게 된다. 즉 콘크리트를 통과하면서 에너지를 잃은 중성자와 콘크리트를 이루는 물질과 중성자간의 상호작용으로 생성되는 광자의 선량을 측정하여 선량을 평가하게 된다. MCNPX 코드2)를 이용하여 가속기 시설의 콘크리트 구조물 외부로 방출되는 중성자 선량과 광자선량을 계산한 결과, 원자력법에서 정한 법정 제한 선량에 훨씬 못 미치는 것을 알 수 있었다.

  • PDF

핵의학과 혈액검사실의 안전 관리 활동에 대한 고찰 (Study on Safety Management Activity of Blood Test Room of Nuclear Medicine Department)

  • 심성재;신영균;문형호;유선희;조시만
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.104-110
    • /
    • 2011
  • Purpose: 최근 의료기관에 대한 객관적인 평가방법은 의료기관 인증제도를 시행하여 의료서비스에 대한 수요자의 신뢰성을 높이고 있다. 또한 핵의학 검사실과 진단검사의학 검사실도 국제적인 여러 종류의 인증제도를 채택하면서 검사실내의 안전관리에 관한 사항이 중요시 되고 있다. 핵의학과 혈액검사실에서도 검체에 의한 감염 및 방사성 동위원소시약을 비롯한 여러 유해환경에 노출되어 있으므로 직원 및 환자의 안전관리 영역에 많은 관심이 요구된다. 이에 본원 핵의학과 혈액검사실에서 실시하고 있는 직원 및 환자의 안전관리 활동에 대해 논해 보고자 한다. Material & Method: 본원 핵의학과 혈액검사실에서는 안전관리 책임자에 의해 전반적인 안전관리 사항이 제시되고 검사실 모든 직원이 이를 업무에 적용하고 있다. 정해진 규정에 따라 안전관리 교육을 정기적으로 실시하고 있으며, 검사 업무 중에는 개인 보호구 착용 및 손 위생을 시행하여 감염을 예방하고 있다. 또한 기술적 안전지침과 정전으로 발생되는 사고지침을 통해 유사시에 대비하고 있다. 감염관리 지침을 통해 감염 예방 및 감염 시 대비 요령을 숙지하고 방사성 동위원소 관리, 시약 사용에 대한 안전관리 및 유해화학 물질에 대한 안전 지침을 업무에 적용하고 있다. Result: 핵의학과 혈액검사실에서는 안전관리 규정을 업무에 적용하고 있다. 손 위생을 실시해야 하는 상황에서 손 씻기를 시행하여 직원 및 환자 간 감염을 예방하고 있으며, 검체에 의한 감염을 예방하고자 개인 보호구 착용을 하고 있다. 혈액검사실 내에서 사용하고 있는 시약에서 유해물질로 분류된 시약은 쉽게 알아 볼 수 있도록 분리하여 보관하며 방사성 폐기물 및 일반 의료 폐기물도 효율적으로 안전한 관리를 하고 있다. 이와 같은 많은 안전관리 활동을 통해 직원들은 안전관리 의식이 향상 되었으며 환자들은 여러 위험으로부터 보호되고 있다. Conclusion: 핵의학과 혈액검사실 직원은 안전관리에 대한 규정을 충분히 숙지하고 업무에 적용해야 한다. 더 나은 안전관리에 대한 제안이 나오면 검토하여 적용하고 직원 및 환자의 안전관리에 대한 질적 향상을 높여야 할 것으로 사료된다.

  • PDF

방사성물질을 이용한 치료의 안전관리 고찰 (Radiation Safety Consideration Regarding the Treatment which uses the Radioactive Substance)

  • 임청환;김승철;이귀원
    • 한국콘텐츠학회논문지
    • /
    • 제8권11호
    • /
    • pp.217-224
    • /
    • 2008
  • 방사성 물질 중 동위원소를 이용한 치료는 1964년부터 현재까지 꾸준히 증가하는 추세이다. 그에 따른 안전관리도 강화 되었다. 그러나 현재 규정과 제도가 오히려 치료행위에 악영향을 주거나 이를 회피하기 위한 수단으로 임상에서 치료병동을 개설하지 아니하고 소량의 방사능으로 치료를 하고 있으며, 치료병동이 있다 하더라도 그 시설을 감당하지 못하고 많은 입원환자를 유치하지 못함으로 인하여 환자가 치료를 받기위해 상당기간 동안 대기하여야 한다. 최근 원자력의학원에서 기존 병실을 포함한 약 10개 병실을 보유하게 되어 대기 상태가 해소된 듯 보여 지지만 현재 국내에서 약 28개 병원에서만 총 57개의 방사성 동위원소 병실을 사용 하고 있어 아직 까지도 상당기간 치료를 위하여 대기하고 있는 실정이다. 따라서 환자는 호르몬 조절시간이 장기화 되고 치료병실이 없는 의료기관에서는 최대 방사능 30mCi로 수차례에 걸쳐 시행하게 된다. 이는 환자, 가족, 지인 등에게 수회에 걸쳐 피폭을 주는 결과를 발생시킬 것이다. 또한 의료인 및 보건의료인이 환자 및 보호자에게 피폭에 대한 고지의무를 다한다 하더라도 환자를 비롯한 가족에게는 상당한 심적 부담감을 줄 수 있을 것이다. 그러므로 현재 3차 진료에 해당하는 병원 및 의료기관에서는 치료병실을 설치해야하는 필수 조건으로 의무화 하는 등 방사성동위원소 치료에 따른 시설 강화와 제도 개선의 노력이 있어야 할 것이다.

Ir-192 방사성소선원에 의한 뇌종양의 치료계획 (Ir-192 Brachytherapy Planning of Brain Tumor)

  • 최태진;박정호;김옥배;서수지
    • Radiation Oncology Journal
    • /
    • 제6권2호
    • /
    • pp.277-281
    • /
    • 1988
  • Although widely used in external beam treatment planning, computed tomography scans are infrequent in incranial tumors by implanting of Radioactive isotope. This incranial brachytherapy has only become possible by using CT scans and stereotaxic operation methods. The coincidence of single source and tumor axes in brachytherapy is very important to determine the therapeutic dosages. Eventhough using the CT scan, according to spatial location of tumor tying, the section of tumor will be seen enlargement, cause the tumor will be cut off with slight angle to its axes. Correct analysis of tumor size from source is required for rotated axes in analytical geometry.

  • PDF