Measurement of Bremsstrahlung Radiation with Electron Beam Energy

  • Srivastava, R.P.;Chaurasia, P.P.;Prasiko, G.;Jha, A.K.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.235-236
    • /
    • 2002
  • A Klystron powered dual photon energy electron linear accelerator 2300 C/D from Varian Associates has been installed in our center. From the radiological safety view as well as treatment planning, the output (contamination) of Bremsstrahlung Radiation with electron beam energy determined accurately. It has been found 0.5% to 4.7% with increasing the electron beam energy which is the clinically not much significant in the treatment of the malignant diseases with the treatment of electron beam.

  • PDF

병원에서의 환자, 의료진의 전자파 노출 실태 조사 (Research of operators and patients exposed to electromagnetic field in the hospital)

  • 지효철;홍현기;김성우;이주형;김덕원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.70-72
    • /
    • 2007
  • In this study, electromagnetic fields emitted from the various environment in the hospital were measured. Measurement spot was patients' head. To monitor how much magnetic fields are emitting from operation room, monitoring device was attached to 19 anesthesiologist and monitoring lasted 8 hours. We also took a measurement from various medical devices. Devices include ESWL, PET, MRI, CT, Gamma knife, X-ray, Angiogram, Echocardiogram, Upper GI and Linear Accelerator. Electromagnetic fields were measured from 10 spots from each of 5 patient waiting room. As a results, there were no places showing risk of high exposure. All the measurement values were below the reference levels for general public exposure to time varying electric and magnetic fields which is issued by ICNIRP.

  • PDF

TM31010 계열의 공동이온전리함과 TG-51을 이용한 선형가속기광자선의 5년간 출력선량 평가 (Evaluation of the Output Dose of a Linear Accelerator Photon Beams by Using the Ionization Chamber TM31010 Series through TG-51 Protocol to Postal Monitoring Output of RPC for 5 Years)

  • 최태진;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제22권2호
    • /
    • pp.92-98
    • /
    • 2011
  • 방사선의 출력선량계수는 모든 선량계획과 치료선량결정에 영향을 주게 되므로, 정확한 선량평가가 강조되고 있다. 저자들은 물흡수선량을 결정하는 선량프로토콜을 종전의 TG-21에서 TG-51로 전환하여 2007년부터 새로운 버전과 새로운 공동전리함으로 선량을 평가하기 위해 SSDL의 $N_k$$N_{dw}{^{Co-60}}$로 변환하여 적용하였다, 평가된 물흡수선량계수는 치료선량결정과 RPC의 선량모니터링을 통해 비교되었으며, 선량평가는 2% 이내를 보였지만 불안정성을 확인하게 되었으며, 선량평가과정을 후향적으로 모니터하였다. 점검결과 새 전리함의 교정계수가 -2.8% 낮은 것을 확인하고 PSDL의 물흡수선량교정계수를 구하여 출력선량계수를 구하였으며, 선량평가 결과 2010년부터 안정되었고 지속적으로 1% 이내의 오차를 나타내었다.

광중성자 발생으로 인한 전립샘암 환자의 유전적 위험과 발암의 확률에 관한 연구 (A Study on the Genetic Risk and Carcinogenesis Probability of Prostate Cancer Patients Due to Photoneutron Generation)

  • 이주아
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.473-479
    • /
    • 2023
  • 본 연구에서는 고 에너지를 이용한 전립샘암의 방사선 치료 시 발생되는 광중성자의 선량을 광자극발광선량계를 사용하여 측정하였다. 이에 따른 복부에 발생되는 유효선량에 의한 유전적 위험확률을 연구하고자 하였다. 15 MV 에너지 발생이 가능한 의료용 선형가속기 True Beam STx(Varian Medical Systems, USA)와 방사선 치료 계획 시스템(Eclipse, Varian Medical System, USA)을 사용하였다. 선형가속기 Couch 위에 인체팬텀을 설치하고, 광중성자 선량의 측정은 Albedo Neutron Optical Stimulation Luminescence Neutron Detector(Landauer Inc., IL, USA)를 사용하였다. VMAT과 3C-CRT 의 복부에서 광중성자 선량값은 VMAT이 3D-CRT에 비하여 2배 이상 높은 52.8 mSv 였다. 전립샘암의 방사선 치료 시, 광중성자 선량으로 인한 복부에 발생되는 유효선량에 의한 유전적 위험확률은 VMAT는 1,000명 당 3.2명, 3D-CRT는 1.4명이 발생률임을 산출하였다. 전립샘암의 방사선 치료 시 발생할 수 있는 큰 부작용이 있는 복부를 연구함으로써 전립샘암 환자들의 삶의 질과 확률적 영향을 연구하는데에 의미 있는 연구로 활용되어지길 기대한다.

중앙성육아종의 방사선치료 (Radiation Therapy (RT) of Midline Granuloma)

  • 권형철;오윤경;길학준;윤세철;박용휘
    • Radiation Oncology Journal
    • /
    • 제4권2호
    • /
    • pp.135-139
    • /
    • 1986
  • 중앙성육아종 환자 7예에 대하여 가톨릭의대 강남성모병원 방사선치료실에서는 1983년 3월 부터 1986년 6월까지, 사이에 외부방사선치료를 시행하였다. 임상증상으로서, 모든 환자에서 침습부위에 궤사를 동반한 부비동염 증세를 보였고, 1예에선 대장(결장)병변도 나타냈다. 방사선치료는 6MV선형가속기를 사용하여 비강 및 부비동 부위를 포함하는 상기도 부위에 $2\~3$문 조사를 실시하여, 총선량 $4,000\~5,000cGy/5\~6$주를 조사하였다. 방사선치료 반응으로서 방사선치료 종료 후 $1.5\~20$개월 추적관찰 한 결과 완전 및 부분관해가 각각 3예, 대장부위에 병변을 보였던 1예에선 병이 진행되고 있음이 관찰되었다.

  • PDF

콤팩트 전자 선형가속기 시작품의 출력측정에 관한 연구 (Measurement of Electron Beam Output for the Prototype Compact Linac)

  • 김성우;강상구;이동주;임희진;이만우;이준규;이무진;양광모;노태익;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.1-5
    • /
    • 2015
  • 의료용 및 산업용으로 활용하기 위한 C-밴드형 콤팩트 선형가속기의 개발이 동남권원자력의학원에서 진행되고 있다. 본 논문에서는 선형가속기 시작품에서 발생한 전자빔의 출력 측정 결과를 보고하고자 한다. 출력 측정은 물흡수선량에 대해 교정된 Exradin-A10 마커스형 평행평판형 전리함을 사용하여 물속 기준 깊이에서 IAEA TRS-398 프로토콜에 따라 흡수선량율을 결정하는 과정으로 진행되었다. 전자선 에너지가 낮은 점으로 인하여 선질지표($R_{50}$)은 필름 측정법을 써서 근사적으로 결정하였다. 결과로서 단위 펄스 진동수당의 선형가속기 전자빔의 출력은 $17.0cGy/(min{\cdot}Hz$로 나타났다. 본 연구의 결과는 개발 중인 전자가속기의 성능 평가 자료로 활용될 것이다.

Determination of Initial Beam Parameters of Varian 2100 CD Linac for Various Therapeutic Electrons Using PRIMO

  • Maskani, Reza;Tahmasebibirgani, Mohammad Javad;Hoseini-Ghahfarokhi, Mojtaba;Fatahiasl, Jafar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권17호
    • /
    • pp.7795-7801
    • /
    • 2015
  • The aim of the present research was to establish primary characteristics of electron beams for a Varian 2100C/D linear accelerator with recently developed PRIMO Monte Carlo software and to verify relations between electron energy and dose distribution. To maintain conformity of simulated and measured dose curves within 1%/1mm, mean energy, Full Width at Half Maximum (FWHM) of energy and focal spot FWHM of initial beam were changed iteratively. Mean and most probable energies were extracted from validated phase spaces and compared with related empirical equation results. To explain the importance of correct estimation of primary energy on a clinical case, computed tomography images of a thorax phantom were imported in PRIMO. Dose distributions and dose volume histogram (DVH) curves were compared between validated and artificial cases with overestimated energy. Initial mean energies were obtained of 6.68, 9.73, 13.2 and 16.4 MeV for 6, 9, 12 and 15 nominal energies, respectively. Energy FWHM reduced with increase in energy. Three mm focal spot FWHM for 9 MeV and 4 mm for other energies made proper matches of simulated and measured profiles. In addition, the maximum difference of calculated mean electrons energy at the phantom surface with empirical equation was 2.2 percent. Finally, clear differences in DVH curves of validated and artificial energy were observed as heterogeneity indexes were 0.15 for 7.21 MeV and 0.25 for 6.68 MeV. The Monte Carlo model presented in PRIMO for Varian 2100 CD was precisely validated. IAEA polynomial equations estimated mean energy more accurately than a known linear one. Small displacement of R50 changed DVH curves and homogeneity indexes. PRIMO is a user-friendly software which has suitable capabilities to calculate dose distribution in water phantoms or computerized tomographic volumes accurately.

Maker Seed Phantom을 이용한 표적위치의 정확성 평가 (Evaluation of Targeting Using Marker Seed Phantom)

  • 장은성;정봉재;임인철;강수만
    • 한국방사선학회논문지
    • /
    • 제5권2호
    • /
    • pp.67-72
    • /
    • 2011
  • 선형가속기에 설치된 OBI (On-Board $Imager^{TM}$ Varian Medical Systems. USA)의 정도관리는 일간 및 주간으로 하고 있으며 이때 기하학적인 정확성은 매우 중요하게 된다. 본 실험에서 4개월간 선형가속기의 OBI 장치 정도관리용 팬톰을 사용하여 일간과 주간으로 선형가속기의 기계적인 중심점(isocenter)과 가시화된 레이저의 중심점의 일치정도 및 OBI 장치 및 레이저의 중심점을 비교하여 데이터화함으로써 OBI 장치의 기계적 정확성과 정도관리용 팬톰을 사용하여 일간, 주간으로 선형가속기 환자위치 및 레이저의 등 중심점을 체크하여 데이터화함으로써 사후관리 및 환자치료 성적을 높일 수 있다고 사료된다.

6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성 (Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • 한국의학물리학회지:의학물리
    • /
    • 제15권2호
    • /
    • pp.105-111
    • /
    • 2004
  • 본 연구에서는 의료용 선형가속기로부터 발생되는 명목상 가속전압 6 MV선의 검출특성을 확인하기 위하여 유전체 물질을 사용한 평행판 검출기를 제작하였다. 제작한 검출기의 전극은 단면이 크롬으로 코팅되어 있는 FEP유전체 필름(두께: 100 $\mu\textrm{m}$)을 사용하였고 두 전극 사이에 PTFE유전체 필름(두께 : 100 $\mu\textrm{m}$)을 삽입하였다. 측정을 위하여 선원-팬텀 표면간의 거리 100 cm, 그리고 팬텀의 표면으로부터 깊이 5 cm되는 지점에 방사선 유도전하를 획득하기 위한 제작검출기를 놓았다. 방사선 조사시 제작검출기의 유용성을 알아보기 위하여, 영점 변동, 누설 전류, 인가전압에 따른 검출기의 반응, 재현성, 선형성, 조직최대선량비 등을 측정하였다. 측정결과 검출기의 영점 변동 전류 (I$_{Z}$ )는 8.3 pA, 누설 전류(I$_{I}$)는 10 pA 이었다. 제작 검출기는 인가전압에 대한 선형성을 보였으며, 또한 재현성실험에서는 조사된 선량에 대하여 1% 오차 범위 내에서 일치하였다. 검출기의 선량에 대한 선형성은 3% 이내의 오차범위에서 일치하면서 선량율 의존성이 있음을 확인하였다. 조직최대선량비분포에 대한 제작 평행판 검출기와 비교검출기간의 선량오차는 팬텀내의 최대 선량점으로부터 7.5 cm까지 3% 이내에서 일치하였다. 본 연구결과 유전체 필름을 이용한 평행판 검출기는 선량계로서의 기본적인 특성들을 허용 가능한 범위에서 만족스러워 상대선량측정을 위한 검출기로 사용할 수 있음을 확인할 수 있었다.

  • PDF

가상쐐기를 이용한 반대측 유방선량감소 (Contralateral Breast Dose Reduction Using a Virtual Wedge)

  • 여인환;김대용;김태현;신경환;지의규;박원;임도훈;허승재;안용찬
    • Radiation Oncology Journal
    • /
    • 제23권4호
    • /
    • pp.230-235
    • /
    • 2005
  • 목적: Siemens사 선형가속기에 장착된 가상쐐기를 이용하여 반대측 유방에 흡수되는 선량을 기존쐐기와 비교 연구하고자 하였다. 대상 및 방법: 반대측 유방선량을 인체모형에서 이극진공관을 사용하여 측정하였다. 이극진공관을 조사영역의 내측 경계선으로부터 반대쪽 외측방향으로 5.5 cm (1번 위치), 9.5 cm (2번 위치), 14 cm (3번 위치) 떨어진 곳에 위치하였다. 6 MV X-선을 이용하여 50도와 230도에서 $17{\pm}10cm$의 비대칭조사영역을 사용하여 접면 조사를 실시하였다. 첫번째 실험은 4가지의 치료방법을 시도하였다; (i) 개방 내측조사와 30도 기존쐐기를 사용한 외측조사; (ii) 15도 기존쐐기를 사용한 내측 및 외측조사; (iii) 개방 내측조사와 30도 가상쐐기를 사용한 외측조사; (iv) 15도 가상쐐기를 사용한 내측 및 외측조사. 두번째 실험은 개방조사, 15도 및 60도 기존쐐기 및 가상쐐기 모두를 사용하여 내측조사를 시행하였으며, 이때 동일한 모니터단위로 조사하였다. 모든 실험은 3회 반복되었다. 결과: 첫번째 실험은 반대측 유방선량은 1번 위치, 2번 위치, 3번 위치의 순으로 감소한다. 또한 기존쐐기 및 가상쐐기와 무관하게 내측에 쐐기를 사용한 경우($3.25{\pm}1.59%$)보다는 사용하지 않은 경우(2.70{\pm}1.45%$) 선량이 낮았고, 이러한 차이는 가상쐐기($0.10{\pm}0.01%$)보다 기존쐐기($0.99{\pm}0.18%$)의 경우 더 컸다. 가상쐐기의 사용은 같은 기법의 기존쐐기를 사용한 것에 비해 처방선량 대비 $0.12{\sim}1.20%$의 반대측 유방선량을 감소시켰다. 두번째 실험시 1번 위치에서는 개방빔, 가상쐐기, 기존쐐기 순으로 선량이 높았으며, 2, 3번 위치에서는 기존쐐기, 개방빔, 가상쐐기 순으로 선량이 높았다. 결론: Siemens사 선형가속기에 장착된 가상쐐기를 사용할 경우 반대측 유방선량을 줄일 수 있으며, 위치에 따른 선량분포는 Varian사 것과 차이가 있었다.