Measurement of Linear Energy Spectra for 135 MeV/u Carbon Beams in HIMAC Using Prototype TEPC (프로토 타입 조직등가비례계수기의 중입자가속기연구소의 135 MeV/u 탄소 이온에 대한 선형에너지 스펙트럼 측정)

  • Nam, Uk-Won;Lee, Jaejin;Pyo, Jeonghyun;Park, Won-Kee;Moon, Bong-Kon;Lim, Chang Hwy;Moon, Myung Kook;Kitamure, Hisashi;Kobayashi, Shingo;Kim, Sunghwan
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.197-201
    • /
    • 2014
  • TEPC (Tissue Equivalent Proportional Counter) was usually used for high LET radiation dosimetry. We developed a prototype TEPC for micro-dosimetry in the range of $0.2{\sim}300 keV/{\mu}m$. And, the simulated site diameter of the TEPC is $2{\mu}m$, of similar size to a cell nucleus. For purposes of characterization the response for high LET radiation of the TEPC has been investigated under 135MeV/u Carbon ions in HIMAC (Heavy Ion Medical Accelerator). We determined the gas multiplication factor and measured the lineal energy spectrum [yd(y)] of 135 MeV/u Carbon ions. The value of the gas multiplication factor was 315 at 700 V bias voltage. As a result of the experiment, we could more understand the performance of the TEPC for high LET (Linear Energy Transfer) radiation. And the procedure of high LET radiation dosimetry using TEPC is established.

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

Therapeutic Effect of Combined Radiotherapy and Hyperthermia in Primary Hepatocellular Carcinoma (원발성 간암의 방사선치료및 온열요법의 병용치료 효과)

  • Kang Ki Mun;Choi Ihl Bohng;Kay Chul Seung;Choi Byung Ok;Chung Su Mi;Kim In Ah;Han Sung Tae;Sun Hee Sik;Chung Kyu Won;Shinn Keyong Sub
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.191-199
    • /
    • 1994
  • Purpose : This study was undertaken to show the clinical results of combined radiotherapy and hyperthermia in primary hepatoma Materials and Methods : Between December 1989 and March 1993, 50 patients with hepatomas were treated by combined radiotherapy and hyperthermia. Among them, we analyzed retrospectively 33 patients who received the complete course of treatment. The ages of the patients ranged from 36 to 75(mean age: 55.5 years). Twenty-six patients ($78.8\%$) were men, and 7 ($21.2\%$ were women. According to Child's classification, nine patients ($27.3{\%}$) were A group, 9 ($27.3\%$) were B group, 15 ($45.4\%$) were C group. Radiation therapy was done by a 6 MV and 15 MV linear accelerator. Patients were treated with daily fractions of 150-180 cCy to doses of 2550 cGy -4950 cGy (median : 3000 cGy). Local hyperthermia was done by 8 MHZ RF capacitive heating device (Cancermia. Green Cross Co., Korea), 50-60 min/session, 1-2 sessions/wk, and 8.5 sessions (median number)/patient. We analyzed the prognostic factors including age, sex, tumor type, Child's classification, $\alpha$-fetoprotein, liver cirrhosis, ascites, portal vein invasion, esophageal varix, number of hyperthermia, chemotherapy, total bilirubin level, Karnofsky perfomance status. Results : The overall 1-year survival was $24.2\%$, with a mean survival of 10months. Of 33 patients, tumor regression (PR+MR) was seen in $30.4\%$, no response was seen in $52.2\%,\;17.4\%$ patient was progressed. In patients who had tumor regression, the overall 1-year survival was $42.1\%$ with a mean survival of 14 months. Factors influencing the survival were sex (p=0.05), tumor type (p=0.0248), Child's classification (p=0.0001), liver cirrhosis (p=0.0108), ascites (p=0.0009), and Karnofsky perfomance status (p=0.0028). Complications developed in 28 patients, including 18 hot pain,5 fat necrosis, 3 transient fever, 2 nausea and vomiting. Conclusion : In this study, the results suggests that combined radiotherauy and hyperthermia may improve the survival rate of hepatoma.

  • PDF

The Usefulness Assessment of Verifying Daily Output by Using CHECKMATE$^{TM}$ (CHECKMATE$^{TM}$를 이용한 일일 출력 검증의 유용성 평가)

  • Cho, Han-Sang;Nam, Sang-Soo;Park, Hae-Jin;Kim, Mi-Hwa;Park, An-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Purpose: In this study, we tried to check the usefulness of two Linear Accelerators, Clinac IX and 21EX (Varian, Palo Alto, CA), which are equipped in Ajou Medical Center. From 2008 to 2010, we evaluated the error range of Absolute Dose based on the daily output, which was measured by CHECKMATE$^{TM}$ (Sun Nuclear, Melbourne, FL). Materials and Methods: For Daily Q.A, photon beams of two linear accelerators, 21EX and IX (6 MV and 10 MV, respectively) were measured daily by using CHECKMATE$^{TM}$ just before the treatment began, while the absolute dose was measured biweekly by using water phantom. We analyzed the data of measured values from the daily Q.A and the absolute dose from 2008 to 2010 for 21EX, and from 2009 to 2010 for IX. We utilized Excel 2007 (Microsoft, USA) to evaluate Average, Standard deviation and Confidence level of the data. Furthermore, in order to check the measured values of CHECKMATE$^{TM}$ and the significance of absolute dose, each error value was compared and analyzed. Results: During the observation period, the output of two equipment's absolute dose increased in process of time and in both 6 MV and 10 MV, there was a similar increasing trend. In addition, the error rate of the measured value of CHECKMATE$^{TM}$ and the value of absolute dose were under 0.34, which means that there is a similarity relationship between the two measured values. After checking that the measured value of CHECKMATE$^{TM}$ increased, We measured the absolute dose to adjust that. When the error range was close to 2~3%, the number of changing the output was four for 21EX and three for IX. Conclusion: As a result of measuring and analyzing the daily output changes for two years by using CHECKMATE$^{TM}$, we could find that there is a significance between the output which we should obey during Q.A, and the measured value of absolute dose within the error tolerance of 2~3%. Thus, the use of CHECKMATE$^{TM}$ can be positively considered for more efficient and reliable daily output verification of linear accelerator. It can also be a good standard for other medical centers to understand the trends of linear accelerator and to refer to for the correction of each output.

  • PDF

Development of a Method to Measure the Radiation Isocenter Size of Linear Accelerators and Quantitative Analysis of the Radiation Isocenter Size for Clinac 21EX Linear Accelerator (선형가속기 방사선 중심점의 크기 측정 방법 개발과 Clinac 21EX 선형가속기의 방사선 중심점 크기 분석)

  • Jeon, Ho-Sang;Nam, Ji-Ho;Park, Dahl;Kim, Yong-Ho;Kim, Won-Taek;Kim, Dong-Won;Ki, Yong-Kan;Kim, Dong-Hyun
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.131-139
    • /
    • 2011
  • A method to get a size of the radiation isocenter of linear accelerators using star-shot images was presented and a computer program was developed to automate the method. Accuracy of the method was verified. The developed program was used to measure sizes of the radiation isocenters for a Clinac 21EX (Varian, USA) using data of quality assurance (QA) performed from June 2008 to December 2010. To calculated the size of radiation isocenter, positions of two points on each central ray of the star-shot image were found and the equation of the central ray was determined using the positions of two points. Using the equations of central rays the radius of the minimum circle intersecting all the central rays, which is one half of the size of radiation isocenter, was calculated. The program measured x-intercepts and y-intercepts of the central rays within errors of 0.084 mm and sizes of radiation isocenters within 0.053 mm. All the errors were less than the spatial resolution of star-shot images 0.085 mm. The radiation isocenter sizes of Clinac 21EX were $0.33{\pm}0.27mm$, $0.71{\pm}0.36mm$, $0.50{\pm}0.16mm$ for collimator, gantry and couch respectively. During the measurement period all the measured sizes were less than 2.0 mm and within tolerance. The developed program could calculate the size of radiation isocenters and it would be helpful to routine QA.

Analysis on the Calculated Dose in the Lung Radiation Surgery Planning Using TomoTherpay (토모테라피를 이용한 폐종양 방사선수술 계획 시 선량 분석)

  • Song, Ju-Young;Jung, Jae-Uk;Yoon, Mee-Sun;Ahn, Sung-Ja;Chung, Woong-Ki;Nah, Byung-Sik;Nam, Taek-Keun
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.178-183
    • /
    • 2011
  • The applicability and feasibility of TomoTherapy in the lung radiation surgery was analyzed by comparison of the calculated dose distribution in TomoTherapy planning with the results of conventional IMRS (intensity modulated radiation surgery) using LINAC (linear accelerator). The acquired CT (computed tomograph) images of total 10 patients whose tumors' motion were less than 5 mm were used in the radiation surgery planning and the same prescribed dose and the same dose constraints were used between TomoTherapy and LINAC. The results of TomoTherapy planning fulfilled the dose requirement in GTV (gross tumor volume) and OAR (organ at risk) in the same with the conventional IMRS using LINAC. TomoTherapy was superior in the view point of low dose in the normal lung tissue and conventional LINAC was superior in the dose homogeneity in GTV. The calculated time for treatment beam delivery was long more than two times in TomoTherapy compared with the conventional LINAC. Based on the results in this study, TomoTherapy can be evaluated as an effective way of lung radiation surgery for the patients whose tumor motion is little when the optimal planning is produced considering patient's condition and suitability of dose distribution.

Evaluation of Dosimetric Leaf Gap (DLG) at Different Depths for Dynamic IMRT (동적 세기조절방사선치료에서 깊이에 따른 DLG변화 분석)

  • Chang, Kyung Hwan;Kwak, Jungwon;Cho, Byungchul;Jeong, Chiyoung;Bae, Jae Beom;Yoon, Sang Min;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.153-159
    • /
    • 2015
  • This study is to evaluate thedosiemtric leaf gap (DLG) at different depths for dynamic intensity-modulated radiation therapy (IMRT) in order to evaluate the absolute dose and dose distribution according to the different positions of tumors and compare the measured and planned the multileaf collimator (MLC) transmission factor (T.F.) and DLG values. We used the 6 MV and 15 MV photon beam from linear accelerator with a Millenium 120 MLC system. After the import the DICOM RT files, we measured the absolute dose at different depths (2 cm, 5 cm, 10 cm, and 15 cm) to calculate the MLC T. F. and DLG. For 6 MV photon beam, the measured both MLC T. F. and DLG were increased with the increase the measured depths. When applying to treatment planning systemas fixed transmission factor with its value measured under the reference condition at depth of 5 cm, although the difference fixed and varied transmission factor is not significant, the dosiemtric effect could be presented according to the depth that the tumor is placed. Therefore, we are planning to investigate the treatment planning system whichthe T. F. and DLG factor according to at the different depths can be applied in the patient-specific treatment plan.

Dose Distributions for Ll NAC Radiosurgery with Dynamically Shaping Fields (선형가속기를 이용한 방사선 수술시 Dynamical Field Shaping에 의한 선량분포)

  • Suh Tae Suk;Yoon Sei Chul;Kim Moon Chan;Jang Hong Seok;PArk Yong Whee;Shinn Kyung Sub;Park Charn Il;Ha Sung Whan;Kang Wee Saing
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.431-437
    • /
    • 1993
  • An important problem in radiosurgery is the utilization of the proper beam parameters, to which dose shape is sensitive. Streotactic radiosurgery techniques for a linear accelerator typically, use circular radiation fields with multiple arcs to produce an spherical radiation distribution. Target volumes are irregular in shape for a certain case, and spherical distributions can irradiate normal tissues to high dose as well as the target region. The current improvement to dose distribution utilizes treating multiple isocenters or weighting various arcs to change treatment volume shape. in this paper another promising study relies upon dynamically shaping the treatment beam to fit the beam's eye view of the target. This conformal irradiation technique was evaluated by means of visual three dimensional dose distribution, dose volume histograms to the target volume and surrounding normal brain. It is shown that using even less arcs than multiple isocenter irradiation technique, the conformal therapy yields comparable dose gradients and superior homogeneity of dose within the target volume.

  • PDF

Total Body Irradiation in Leukemia - Preliminary Report - (방사선 전신조사)

  • Jang Hong Seok;Chung Su Mi;Choi Ihl Bohng;Kim Choon Yul;Bahk Yong Whee;Kim Choon Choo;Kim Dong Jip;Lee Jae Soo
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.247-251
    • /
    • 1988
  • Total body irradiation has been applied to treat acute leukemia and chronic granulocytic leukemia.20 patients with acute leukemia or chronic granulocytic leukemia were treated with total body irradiation using 6 MV linear accelerator before bone marrow transplantation at the Division of Therapeutic Radiology, Department of Radiology, St. Mary's Hospital, Catholic University Medical College from August 1987 to September 1988. Among 20 patients, 8 patients received 6 fractions of 200 cGy (total 1200 cGy),10 patients received a single 850 cGy radiation,1 patient received 4 fractions totalling 850 cGy (200, 200, 200, 250), and 1 patient received 1100 cGy in 2 fractions (850, 250).17 patients received allogenic grafts, 2 patients received autologous grafts, and only one patient received one locus mismatched graft. 13 patients are still alive and 7 patients died. The complications induced by total body irradiation were nausea and vomiting, diarrhea, skin erruption, mucositis, and pneumonitis.

  • PDF