Direction of Tissue Contraction after Microwave Ablation: A Comparative Experimental Study in Ex Vivo Bovine Liver

  • Junhyok Lee;Hyunchul Rhim;Min Woo Lee;Tae Wook Kang;Kyoung Doo Song;Jeong Kyong Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.42-51
    • /
    • 2022
  • Objective: This study aimed to investigate the direction of tissue contraction after microwave ablation in ex vivo bovine liver models. Materials and Methods: Ablation procedures were conducted in a total of 90 sites in ex vivo bovine liver models, including the surface (n = 60) and parenchyma (n = 30), to examine the direction of contraction of the tissue in the peripheral and central regions from the microwave antenna. Three commercially available 2.45-GHz microwave systems (Emprint, Neuwave, and Surblate) were used. For surface ablation, the lengths of two overlapped square markers were measured after 2.5- and 5-minutes ablations (n = 10 ablations for each system for each ablation time). For parenchyma ablation, seven predetermined distances between the markers were measured on the cutting plane after 5- and 10-minutes ablations (n = 5 ablations for each system for each ablation time). The contraction in the radial and longitudinal directions and the sphericity index (SI) of the ablation zones were compared between the three systems using analysis of variance. Results: In the surface ablation experiment, the mean longitudinal contraction ratio and SI from a 5-minutes ablation using the Emprint, Neuwave, and Surblate systems were 28.92% and 1.04, 20.10% and 0.53, and 24.90% and 0.45, respectively (p < 0.001). A positive correlation between longitudinal contraction and SI was noted, and a similar radial contraction was observed. In the parenchyma ablation experiment, the mean longitudinal contraction ratio and SI from a 10-minutes ablation using the three pieces of equipment were 38.60% and 1.06, 32.45% and 0.61, and 28.50% and 0.50, respectively (p < 0.001). There was a significant difference in the longitudinal contraction properties, whereas there was no significant difference in the radial contraction properties. Conclusion: The degree of longitudinal contraction showed significant differences depending on the microwave ablation equipment, which may affect the SI of the ablation zone.

Terahertz Imaging Technology and Applications (테라헤르츠 이미징 기술 및 그 응용 분야)

  • Kim, M.G.;Lee, E.S.;Park, D.W.;Choi, D.H.;Lee, I.M.;Shin, J.H.;Kim, Y.H.;Kim, J.S.;Cho, J.C.;Kim, Y.H.;Kwak, D.Y.;Park, K.H.
    • Electronics and Telecommunications Trends
    • /
    • v.36 no.3
    • /
    • pp.97-105
    • /
    • 2021
  • The terahertz wave (THz wave) is a band between infrared and microwaves and is defined as an electromagnetic wave having a frequency of 0.1 to 10 THz band. THz waves have the property of transmitting nonpolar materials, which the visible light cannot be transmitted, such as ceramics, plastics, and paper; and the photon energy is low, such as several meV. For this reason, non-destructive testing equipment based on THz imaging technology can be applied to the industrial field. Recently, THz imaging technology was applied in wide industrial fields, such as automobiles, batteries, food, medical, and security, and being actively studied. In this paper, we describe the research trends of terahertz imaging technology and experimental results. Furthermore, we summarize the recent commercialized terahertz camera. Finally, we present the research results in the field of the human security scanner system.

Digital X-Ray Technology and Applications (디지털 엑스선 기술과 응용)

  • Jeong, J.W.;Kang, J.T.;Kim, J.W.;Park, S.;Lee, M.L.;Song, Y.H.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.5
    • /
    • pp.1-13
    • /
    • 2019
  • In modern times, X-ray imaging has become a necessary tool for early diagnosis, quality control, nondestructive testing, and security screening. X-ray imaging equipment generally comprises an X-ray generator and an image sensor. Most commercially available X-ray generators employ filament-thermionic electron-based X-ray tubes, thus demonstrating typical analog behavior, such as slow response and large stray X-rays. Furthermore, digital X-ray sources, which have been studied extensively using field electron emitters manufactured from nanometer-scale materials, provide fast and accurately controlled ultra-shot X-rays. This could usher in a new era of X-ray imaging in medical diagnosis and nondestructive inspections. Specifically, digital X-ray sources, with reduced X-ray dose, can significantly improve the temporal and spatial resolution of fluoroscopy and computed tomography. Recently, digital X-ray tube technologies based on carbon nanotubes, developed by Electronics and Telecommunications Research Institute, have been transferred to several companies and commercialized for dental imaging for the first time.

Classification of submitted nuclear medicine dissertation and directional consideration (핵의학 투고 논문 분류 및 방향성 고찰)

  • Ho-Yeon, Cho;Yeong-Ran, Woo;Kang-Rok, Seo;Gun-Chul, Hong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2022
  • Purpose Since 1985, the Korean society of nuclear medicine technology (KSNMT) has been engaged in academic activities related to nuclear medicine imaging. From 2017 to 2021, the papers published in the journal were classified by the specific fields to examine the trends in the research and the direction of nuclear medicine in comparison with the papers submitted to the Korean Society of Nuclear Medicine (KSNM) during the same period. Materials and Methods From 2017 to 2021, papers submitted to KSNMT and KSNM were classified and databaseization using the Excel program by submission type, examination equipment, and examination field. Through this data, the number of papers published in journals by year, the number of papers submitted by detailed fields, and key words by era were analyzed and compared. Results The papers included by journal was 57 KSNMT and 280 KSNM. The major large classification of equipment, PET, Planar and SPECT was 26.3%, 21.1%, 19.3% in the KSNMT, KSNM was 49.6%, 6.4%, and 9.3%, with 66.7% and 65.3%, respectively. the major medium classification of equipment, industrial safety, urogenital system, nervous system, and quality control accounted for 54.4% of the total papers of the total ratio in the KSNMT, while the medium classification of oncology, endocrine system, urogenital system, therapy, and nervous system accounted for 61.1% of KSNM. In the major small classification of image acquisition, improvement effect, and exposure management accounted for 70.2% in KSNMT, while the items of image acquisition, report, and improvement effect accounted for 60.7% in KSNM. The major keywords except for equipment-related keywords such as PET/CT, PET/MR, and SPECT were SUV, Planar Image, and Respiration Gating Method in KSNMT and Ga68, Thyroid, and Lymphoma in the KSNM. Conclusion When checking the last 5 years of submissions, we can see that KSNMT is mainly concerned with image acquisition using existing radiotracers, while KSNM has focused on new radiotracers such as 68Ga, 177Lu, etc., and new medical technologies of theranostic. It has been confirmed that more PET-related papers than other examination equipment will account for a greater number of papers, and it is believed that future submissions will also account for a higher proportion of PET-related papers than other equipment.

Evaluation of the Usefulness of Ancillary Devices for Patients with Acute Lumbar Pain During Magnetic Resonance Imaging (자기공명영상검사 시 급성 요추 통증 환자를 위한 보조기구의 유용성 평가)

  • Park, Hee-Wang;Lee, Moo-Sik;Kim, Yong-Kwon;Bae, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.193-199
    • /
    • 2018
  • The purpose of this study was to evaluate the convenience and image quality of patients with acute lumbar pain patients at a general hospital in Daejeon using ancillary devices for postural changes and correction. The results of the study are summarized as follows. First, the Turbo S pin Echo technique(TS E) using ancillary equipment has the highest image evaluation rating with an average score of 4.440, which is highly valuable on a diagnosis. Second, the average score for patient the questionnaire 'When using ancillary equipment, I feel that my body is calibrated to side without bias.' was shown as 4.440, which is very useful for the correction of the patient's body when using ancillary equipment. Finally, Breath Hold technique(BH) is very effective in shortening test time of acute lumbar pain patients, because it can reduce test time 86.4% faster than Turbo Spin Echo technique(TSE). The results of the study showed that the use of ancillary equipment to perform the test through the side lying postures helped to reduce the pain and control the patient's breathing, and the diagnostic value of the image was high.

A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index (Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구)

  • Kim, Jae-In;Lee, Yang-Sub;Jang, Dong-Soo;Jung, Min-Cheol;Bae, Seung-Ho;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

Analyzing Preprocessing for Correcting Lighting Effects in Hyperspectral Images (초분광영상의 조명효과 보정 전처리기법 분석)

  • Yeong-Sun Song
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.785-792
    • /
    • 2023
  • Because hyperspectral imaging provides detailed spectral information across a broad range of wavelengths, it can be utilized in numerous applications, including environmental monitoring, food quality inspection, medical diagnosis, material identification, art authentication, and crime scene analysis. However, hyperspectral images often contain various types of distortions due to the environmental conditions during image acquisition, which necessitates the proper removal of these distortions through a data preprocessing process. In this study, a preprocessing method was investigated to effectively correct the distortion caused by artificial light sources used in indoor hyperspectral imaging. For this purpose, a halogen-tungsten artificial light source was installed indoors, and hyperspectral images were acquired. The acquired images were then corrected for distortion using a preprocessing that does not require complex auxiliary equipment. After the corrections were made, the results were analyzed. According to the analysis, a statistical transformation technique using mean and standard deviation with reference to a reference signal was found to be the most effective in correcting distortions caused by artificial light sources.

Quantitative Evaluation of Hepatic Steatosis Using Advanced Imaging Techniques: Focusing on New Quantitative Ultrasound Techniques

  • Junghoan Park;Jeong Min Lee;Gunwoo Lee;Sun Kyung Jeon;Ijin Joo
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.13-29
    • /
    • 2022
  • Nonalcoholic fatty liver disease, characterized by excessive accumulation of fat in the liver, is the most common chronic liver disease worldwide. The current standard for the detection of hepatic steatosis is liver biopsy; however, it is limited by invasiveness and sampling errors. Accordingly, MR spectroscopy and proton density fat fraction obtained with MRI have been accepted as non-invasive modalities for quantifying hepatic steatosis. Recently, various quantitative ultrasonography techniques have been developed and validated for the quantification of hepatic steatosis. These techniques measure various acoustic parameters, including attenuation coefficient, backscatter coefficient and speckle statistics, speed of sound, and shear wave elastography metrics. In this article, we introduce several representative quantitative ultrasonography techniques and their diagnostic value for the detection of hepatic steatosis.

Geometric calibration of a computed laminography system for high-magnification nondestructive test imaging

  • Chae, Seung-Hoon;Son, Kihong;Lee, Sooyeul
    • ETRI Journal
    • /
    • v.44 no.5
    • /
    • pp.816-825
    • /
    • 2022
  • Nondestructive testing, which can monitor a product's interior without disassembly, is becoming increasingly essential for industrial inspection. Computed laminography (CL) is widely used in this application, as it can reconstruct a product, such as a printed circuit board, into a three-dimensional (3D) high-magnification image using X-rays. However, such high-magnification scanning environments can be affected by minute vibrations of the CL device, which can generate motion artifacts in the 3D reconstructed image. Since such vibrations are irregular, geometric corrections must be performed at every scan. In this paper, we propose a geometry calibration method that can correct the geometric information of CL scans based on the image without using geometry calibration phantoms. The proposed method compares the projection and digitally reconstructed radiography images to measure the geometric error. To validate the proposed method, we used both numerical phantom images at various magnifications and images obtained from real industrial CL equipment. The experiment results confirmed that sharpness and contrast-to-noise ratio (CNR) were improved.

Study on the Application of Artificial Intelligence Model for CT Quality Control (CT 정도관리를 위한 인공지능 모델 적용에 관한 연구)

  • Ho Seong Hwang;Dong Hyun Kim;Ho Chul Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.182-189
    • /
    • 2023
  • CT is a medical device that acquires medical images based on Attenuation coefficient of human organs related to X-rays. In addition, using this theory, it can acquire sagittal and coronal planes and 3D images of the human body. Then, CT is essential device for universal diagnostic test. But Exposure of CT scan is so high that it is regulated and managed with special medical equipment. As the special medical equipment, CT must implement quality control. In detail of quality control, Spatial resolution of existing phantom imaging tests, Contrast resolution and clinical image evaluation are qualitative tests. These tests are not objective, so the reliability of the CT undermine trust. Therefore, by applying an artificial intelligence classification model, we wanted to confirm the possibility of quantitative evaluation of the qualitative evaluation part of the phantom test. We used intelligence classification models (VGG19, DenseNet201, EfficientNet B2, inception_resnet_v2, ResNet50V2, and Xception). And the fine-tuning process used for learning was additionally performed. As a result, in all classification models, the accuracy of spatial resolution was 0.9562 or higher, the precision was 0.9535, the recall was 1, the loss value was 0.1774, and the learning time was from a maximum of 14 minutes to a minimum of 8 minutes and 10 seconds. Through the experimental results, it was concluded that the artificial intelligence model can be applied to CT implements quality control in spatial resolution and contrast resolution.