• 제목/요약/키워드: Medical examiners

검색결과 50건 처리시간 0.029초

조영제를 사용하는 환자의 부작용: 특성과 관리에 관한 연구 (Studies of the side effects on using the contrast media: It's characteristic and management)

  • 선종률;유세종
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.427-431
    • /
    • 2014
  • The purpose of this study is to monitor the current adverse reactions in administering CT contrast agents at general hospitals and also to suggest the practical guidelines to minimize the risk and to show the successful patient management. At four Dajeon city general hospitals, the contrast agents were administered in 646,828 cases and the overall prevalence of adverse reactions was 4,110 cases from January 2010 to December 2013. However, we excluded the two hospitals' 3,658 cases because the patients' data was inadequate. Consequently, the case surveys on the rest of 452 cases have been studied and submitted. After comparing the patients with a control group, we evaluated that the key factors of the adverse reactions were the gender and age difference of the patients, the examination period, the examination method, the quantity and administrating speed of the contrast agents. Even though the four general hospitals have their own management systems on adverse reactions, but their systems were not satisfying. To improve the quality of the management systems and to investigate further cases, some hospital administration procedures on the subject should be systemized and general hospitals should follow the recommended procedures. Moreover, the existing three-year-term evaluation should not only judge the adverse reaction management but also conclude some details on the sub criteria of the evaluation. The details on the sub criteria include the contrast agent characters, the quantity and administrating speed of the drug, the incidents' occurred time, an anamnesis; a case history, the medical history of the patients and the reaction occurring body parts, and the examination title. The details of the medical examiners are also added to the sub criteria.

Reliability of rehabilitative ultrasound imaging for measuring the gluteus maximus muscle at rest and during contraction

  • Jeong, Ju-Ri;Lee, Su-Jin;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제6권1호
    • /
    • pp.7-13
    • /
    • 2017
  • Objective: The aim of this study was to investigate the inter-rater and intra-rater reliability of rehabilitative ultrasound imaging (RUSI) for measurement of muscle thickness with changes in angles of the gluteus maximus (GM) at rest and during contraction. Design: Cross-sectional study. Methods: Twenty-two healthy men volunteered for this study. GM muscle images were obtained in the resting position and during prone hip extension with knee flexion at hip abduction angles of $0^{\circ}$ and $30^{\circ}$, respectively. Two examiners randomly measured the thickness of the GM twice in three different positions. The first position was a comfortable prone position. The second position was prone hip extension with knee flexion (PHEKF) to $90^{\circ}$. The third position was achieved by hanging a 1-kg weight on the ankle of the lifted leg during PHEKF with the angle of the lifted leg the same as the second position. Intra-class correlation coefficients (ICCs), standard error measurements, and minimal detectable changes were used to estimate reliability. Results: The intra-rater reliability ICCs (95% confidence interval) of the GM were >0.870, indicating good reliability. Inter-rater reliability ICCs ranged from 0.668 to 0.913. The reliability of measurements of muscle thickness at each position was similar to the reliability of the angle change. Differences in muscle thickness and ratios for each position with $0^{\circ}$ and $30^{\circ}$ of hip abduction were not statistically significant. Conclusions: In the present study, the intra-rater reliability of muscle thickness measurements of the GM was good, and the inter-rater reliability was moderate to good. Reliable RUSI measurements of wide and large muscles, such as the GM muscle at rest and during contraction, are feasible. Further investigation is required to establish the reproducibility of the protocols presented in this study.

Cone-beam computed tomography characterization of the intraosseous vascular canal in the lateral wall of the maxillary antrum

  • Shetty, Shishir Ram;Al Bayatti, Saad Wahby;Marei, Hesham;Shetty, Raghavendra;Abdelmagyd, Hossam Abdelatty;Luke, Alexander Maniangat
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권1호
    • /
    • pp.34-39
    • /
    • 2021
  • Objectives: The purpose of the study was to assess the occurrence, location, and dimensions of the intraosseous vascular canal in the lateral wall of the maxillary antrum using cone-beam computed tomography (CBCT). Materials and Methods: In this retrospective study, we examined 400 CBCT scans from our archive of patients who had earlier reported to a dental teaching hospital in the United Arab Emirates. The prevalence, location, and dimensions of the lateral antral intraosseous canal (LAIC) in the maxillary antrum were evaluated by 2 examiners using standardised methods. A third examiner was consulted in cases of disagreement. Results: The prevalence of LAIC was 62.3% (249 maxillary antra) among the study population. The mean distance between the most inferior point of the alveolar bone and the inferior border of the LAIC in the posterior maxillary region was 19.83±3.12 mm. There was a significant difference (P=0.05) between the maxillary molar and premolar regions in mean distance from the most inferior point of the alveolar bone and the inferior border of the LAIC. There was no statistically significant difference in mean distance between the most inferior point of the alveolar bone and the inferior border of the LAIC between dentulous and edentulous areas (P=0.1). The G3-intrasinusal type canal less than 1mm in diameter was the most common type of LAIC. Conclusion: This study established the approximate location of the LAIC in a United Arab Emirates cohort, which will assist the oral surgeon in selecting the appropriate site for sinus lift procedures with reduced risk of surgical hemorrhage.

차아염소산나트륨 처리와 멸균법이 근관 치료용 파일의 부식에 미치는 영향에 관한 연구 (THE EFFECT OF NAOCL TREATMENT AND STERILIZATION PROCEDURES ON THE CORROSION OF ENDODONTIC FILES)

  • 양원경;라윤식;이영규;손호현;김미리
    • Restorative Dentistry and Endodontics
    • /
    • 제30권2호
    • /
    • pp.121-127
    • /
    • 2005
  • 근관 치료시 많이 사용되고 있는 $K-flex^{(R)}$ S-S 파일 (Maillefer, USA)과 $Profile^{(R)}$ Ni-Ti 파일 (Maillefer, USA), $K-3^{(R)}$ Ni-Ti파일 (SybronEndo, USA)의 부식 정도를 보기 위하여 총 360개의 20번 file을 1) 멸균소독 방법 (고압가열멸균소독, E-O gas 소독) ,2) 근관세척 액 ($5,25\%$ 차아염소산나트륨, 생리식염수) ,3) 멸균소독 횟수 (1, 5, 10회 ) 에 따라 36개 실험군으로 나누었다. 각각의 파일을 각 군별로 처리한 뒤, 세 명의 검사자가 광학 현미경 하에서 25배의 배율로 검사하여 0; 부식 없음, 1; 경도의 부식, 2; 중등도의 부식, 3; 심한 부식으로 점수화 하였다. 심한 부식을 보이는 파일의 표면은 SEM으로 관찰하였고 Kruskal-Wallis test (p < 0.05)를 이용하여 통계 분석 처리하여 차아염소산나트륨 접촉 여부와 멸균소독 방법의 차이에 의한 부식 정도를 평가하였다. 그 결과 고압가열멸균소독을 10회 시행한 파일은 통계적으로 유의한 차이를 보여 부식 정도가 심하였고, 1회나 5회 고압가열멸균소독을 시행한 파일과 E-O 가스로 소독한 파일들은 부식의 정도가 경미하여 통계적으로 유의하지 않았다. 차아염소산나트륨 접촉 여부와 제조사 혹은 파일 재료에 따른 유의성 있는 차이는 없었다

MTA와 4-META/MMA & TBB레진 혼합 재료의 치근단 미세누출에 관한 연구 (APICAL MICROLEAKAGE OF MTA WITH 4-META/MMA & TBB RESIN AS A ROOT-END FILLING MATERIAL)

  • 김진철;김미리;고현정;양원경
    • Restorative Dentistry and Endodontics
    • /
    • 제34권4호
    • /
    • pp.371-376
    • /
    • 2009
  • 이 연구에서는 Mineral Trioxide Aggregate (MTA)와 4-methacryloxyethyl trimellitate anhydride (4-META) / methyl methacrylate (MMA) & tri-n-butylborane (TBB) 레진을 혼합하여 치근단 역충전 재료로 사용하였을 때의 미세누출을 MTA, 포틀랜드 시멘트와 비교하였다. 발치된 사람 치아의 근관형성 및 충전 후 치근단 절제와 역충전 와동을 형성하였다. MTA, Portland cement, MTA와 4-META/MMA & TBB레진을 혼합한 각각의 재료로 치근단을 역충전한 후 methylene blue dye에 72시간 동안 침적하여 염료가 침투한 길이를 10배 현미경 하에서 측정하였다. MTA와 4-META/MMA & TBB 레진 혼합 충전 군에서는 포틀랜드 시멘트나 MTA 충전군보다 통계적으로 유의하게 적은 미세 누출을 보였으며, 포틀랜드 시멘트와 MTA 충전군의 미세 누출 정도는 통계적으로 차이가 없었다. 이 실험의 결과로 보아 MTA와 4-META/MMA & TBB레진 혼합 재료는 치근단 역충전시 포틀랜드 시멘트나 MTA에 비해 낮은 초기 미세누출을 보여, 치근단 봉쇄 효과가 우수한 것으로 사료된다.

The reliability of dual rehabilitative ultrasound imaging measurements for muscle co-activation

  • Hahn, Joohee;Ha, Hyun-Geun;Lee, Hwang-Jae;Lim, Seungyeop;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제6권3호
    • /
    • pp.152-157
    • /
    • 2017
  • Objective: The aim of this study was to determine the intra-rater and inter-rater reliability of the dual rehabilitative ultrasound imaging (D-RUSI) when simultaneously measuring muscle thickness changes at rest and during co-contraction of the biceps brachii (BB) and triceps brachii (TB). Design: Cross-sectional study. Methods: This study included 36 healthy participants (23 men, 13 women). The participants sat on a chair in a comfortable position with a cushion placed under their elbow to maintain a 90-degree elbow flexion angle. The muscle thickness of the biceps brachii and triceps brachii was measured twice using the D-RUSI by two examiners during resting and co-contraction states. One week later, the same procedure was performed once again. Results: The intra-class correlation coefficients (ICCs) for intra-rater reliability ranged from 0.887 to 0.989 and the confidence interval was within an acceptable range of 0.778 to 0.994. The standard error of measurement (SEM) values ranged from 0.303 to 0.866 and the minimal detectable change (MDC) values ranged from 0.84 to 2.40. The ICCs for inter-rater reliability ranged from 0.758 to 0.925. The SEM values ranged from 0.702 to 1.486 and the MDC values ranged from 1.95 to 4.12. Conclusions: The use of the D-RUSI of the BB muscle had a very good intra-rater reliability and very good inter-rater reliability at the resting state, and a, good inter-rater reliability at the co-activation state. ICC values showed very good intra-reliability and inter-reliability for the TB muscle. the D-RUSI is a useful tool for simultaneously measuring the thickness of two muscles when the BB is an agonist and the TB is an antagonist during co-activation of the upper arm.

針의 巨刺法에 對한 實證的 硏究 -眼球의 Blind spot 變化에 對하여- (The practical study of contralateral therapeutic theory in acupuncture approach -about the change in the blind spot mapping pre and post acupuncture-)

  • 우영민;남영
    • 한방안이비인후피부과학회지
    • /
    • 제13권2호
    • /
    • pp.200-210
    • /
    • 2000
  • objective to ascertain whether the concept of the therapeutic side is associated with changes in the blind sport mapping that represents the brain function. design Physiological blind spot maps were used as an integer of brain activity before and after acupuncture needling on the meridian point Hapkok(合谷) and Techung(太衝) in the unilateral side decided by double-blind controlled study(20 subjects). setting outpatient clinic participants: adult volunteers intervention twenty subjects were divided into two comparative groups and underwent specific acupuncture therapy on the unilateral side. Blinded examiners obtained reproducible pre and post-acupuncture cortical maps, which were subjected to statistical analysis. main outcome measures Brain activity was demonstrated by reproducible circumferential measurements of cortical hemispheric blind spot maps before and after acupuncture on the unilateral side. in case of acupuncture needling on the ipsilateral side of an enlarged side of bilnd spot, there were reduction of blind spot in 7 cases of 10 subjects, and enlargement in 3 cases. in case of acupuncture needling on the contralateral side of the enlarged side of blind spot, there were enlargement of blind spot in 6 cases of 10 subjects, and reduction in 4 cases. results the significant changes in the blind spots before and after acupuncture were observed Acupuncture needlings on the ipsilateral or contralateral side of an enlarged cortical map were associated with the concept of the therapeutic side traditionally accepted in the oriental medical society. Acupuncture needling on the ipsilateral side of an enlarged blind spot map is associated with the reduction of map, and increaed contralateral cortical activity. Acupuncture needling on the side opposite an enlarged blind spot map is associated with the enlargement of map, and decreased cortical activity. conclusion Reproducible maps of cortical responses can be used to measure the neurological consequences of acupuncture needling. Acupuncture can affect the somatic sensory informations that reach to the contralateral thalamus, and so affect thalamic integration. we found that acupuncture therapy may be associated with an increase or a decrease in brain function depending on the side of acupuncture needling. thus, the traditional concept of the contralateral therapeutic theory in acupuncture approach has the clinical significance in the view of brain function.

  • PDF

Reliability and validity of a personal computer based muscle viewer for measuring upper trapezius and transverses abdominis muscle thickness

  • Jeong, Ju-Ri;Han, Ju Hee;Cho, Ji-Eun;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권3호
    • /
    • pp.155-161
    • /
    • 2016
  • Objective: This study aimed to investigate the reliability and validity of a personal computer-based muscle viewer (PC-BMW) compared with that of a portable ultrasound (P-US) for measuring upper trapezius (UT) and transversus abdominis (TrA) muscle thickness at rest and during contraction. Design: Observational inter-rater reliability study. Methods: Fifty-five healthy participants (25 men, 30 women) participated in this study. PC-BMW and P-US were randomly measured at the UT and TrA muscles. Two examiners randomly obtained the images of all participants in 3 test sessions lasting 2 days. Intra-class correlation coefficients (ICCs), standard error of measurement, contraction ratio, and correlation were used to estimate reliability and validity. Pearson's correlation coefficients were used to analyze the relationship between muscle thickness measures taken from PC-BMW and P-US. Results: The intra-rater reliability ICCs of UT and TrA muscle thickness for the PC-BMW were >0.995, indicating excellent reliability. Inter-rater reliability ICCs for the PC-BMW ranged from 0.963 to 0.987. The P-US also exhibited high reliability. A high correlation was found between the measurements of the two muscles in PC-BMW and P-US (p<0.01). Conclusions: PC-BMW provides clear and excellent images, is pocket-sized and less expensive than a conventional ultrasound imaging system. PC-BMW can be utilized variously and has the advantage of rehabilitative ultrasound imaging. More research is needed to evaluate the utility of PC-BMW for rehabilitation.

Can a spontaneous smile invalidate facial identification by photo-anthropometry?

  • Pinto, Paulo Henrique Viana;Rodrigues, Caio Henrique Pinke;Rozatto, Juliana Rodrigues;da Silva, Ana Maria Bettoni Rodrigues;Bruni, Aline Thais;da Silva, Marco Antonio Moreira Rodrigues;da Silva, Ricardo Henrique Alves
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.279-290
    • /
    • 2021
  • Purpose: Using images in the facial image comparison process poses a challenge for forensic experts due to limitations such as the presence of facial expressions. The aims of this study were to analyze how morphometric changes in the face during a spontaneous smile influence the facial image comparison process and to evaluate the reproducibility of measurements obtained by digital stereophotogrammetry in these situations. Materials and Methods: Three examiners used digital stereophotogrammetry to obtain 3-dimensional images of the faces of 10 female participants(aged between 23 and 45 years). Photographs of the participants' faces were captured with their faces at rest (group 1) and with a spontaneous smile (group 2), resulting in a total of 60 3-dimensional images. The digital stereophotogrammetry device obtained the images with a 3.5-ms capture time, which prevented undesirable movements of the participants. Linear measurements between facial landmarks were made, in units of millimeters, and the data were subjected to multivariate and univariate statistical analyses using Pirouette® version 4.5 (InfoMetrix Inc., Woodinville, WA, USA) and Microsoft Excel® (Microsoft Corp., Redmond, WA, USA), respectively. Results: The measurements that most strongly influenced the separation of the groups were related to the labial/buccal region. In general, the data showed low standard deviations, which differed by less than 10% from the measured mean values, demonstrating that the digital stereophotogrammetry technique was reproducible. Conclusion: The impact of spontaneous smiles on the facial image comparison process should be considered, and digital stereophotogrammetry provided good reproducibility.

A Study of Evaluating Eye Movement Based on Ocular Motor Score for Children with Spastic Cerebral Palsy

  • Jeong, Seo-Young;Oh, Tae-Young
    • The Journal of Korean Physical Therapy
    • /
    • 제32권6호
    • /
    • pp.341-347
    • /
    • 2020
  • Purpose: The purpose of this study is to introduce a tool for evaluating eye movement and analyze the reliability of measurement based on 10 cases of evaluating the oculomotor function of children with spastic cerebral palsy Methods: The participants were selected by 6 medical and welfare institutions in Busan as GMFCS grade 1-3 among spastic diplegia and hemiplegia. Seven examiners evaluated 3 children for the evaluation of inter-rater agreement of Ocular Motor Score (OMS) and evaluated the condition of the ocular motor of 10 children using OMS, a re-examination was performed at six weeks after the initial examination. SPSS ver.25.0 was used to calculate the interclass correlation coefficient and Wilcoxon's signed-rank test, Mann Whitney-U test. Results: The inter-rater agreement of OMS was 0.89. Second mean values were decreased compared first examination in motility/ductions/version, saccades and smooth pursuit, but there was no significant difference. Children under 6 years old had a high mean value of saccades in first examination and the motility/ductions/version, fixation, saccades in second examination, but there was no significant difference. Spastic diplegia children's mean values were higher in head posture, fixation in 8 gaze directions than hemiplegia children in both first and second examination, but there were no significant differences. Conclusion: Ocular motor function in 10 children of spastic children who participated in the study and could see that the scores was differed depending on age, type, grade of cerebral palsy. OMS may be available for this purpose.