• Title/Summary/Keyword: Medical Simulator

Search Result 170, Processing Time 0.024 seconds

A Study on Intelligent Trajectory Control for Prosthetic Arm by Pattern Recognition & Force Estimation Using EMG Signals (근전도신호의 패턴인식 및 힘추정을 통한 의수의 지능적 궤적제어에 관한 연구)

  • 장영건;홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.455-464
    • /
    • 1994
  • The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMG signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements.

  • PDF

Implementation of Digital Laser Doppler Flowmetry using DSP (DSP를 이용한 디지털 레이저 도플러 혈류계의 구현)

  • 고한우;김종원
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.6
    • /
    • pp.531-537
    • /
    • 1999
  • 본 연구에서는 FFT와 파라메트릭 방법에 의한 혈류 추정방법을 연구하고 디지털 신호처리 프로세서를 이용하여 레이저 도플러 혈률계를 구현하였다. 레이저 도플러 혈류계는 피부의 모세혈류의 흐름을 측정할수 있는 장비로서 다양한 분야에 활용이 가능하다. 구현된시스템은 TI사의 TMS320C32 DSP를 사용하였으며, 전력 스펙트럼의 모멘트값을 이용하여 혈류를 추정하였다. 혈류 추정 값은 매 0.5초마다 그래픽 사용자 인터페이스를 통해서 표시하도록 하였다. 시스템의 성능을 평가하기 위해서 혈류 시뮬레이터에 흐르는 혈류를 계단함수, 삼각함수, 사인함수로 제어하여 그 결과를 비교하였으며 인체 부위에 따른 혈류를 측정하였다. 실험결과 구현된시스템의 혈류 추정성 및 재현성이 보장되고있음을 확인할수 있었다.

  • PDF

Design of an Electrical Pulse Generator for the Multi-parameter Neuromuscular Stimulation System (다변수 근신경 자극 시스템을 위한 전기자극 펄스 발생기의 설계)

  • Ko, K.R.;Kim, H.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.165-166
    • /
    • 1998
  • A multi-parameter neuro muscular electrical simulator (NMES) system was developed to be used to find the optimal parameter condition in obtaining maximum muscle power and minimal fatigue. Since the performance of NMES is mainly determined by the characteristic of its output-stage circuit, we implemented 3 different circuits and compared output characteristics of them. Three amplifier circuits are; 1) a resonant switching converter, 2) a linear amplifier with a transformer, and 3) a step-up DC/DC converter with a high-voltage linear amplifier. Experimental results showed that the step up DC/DC converter with a high-voltage linear amplifier has the best performance.

  • PDF

Postural Balance Rehabilitation using Virtual Reality Technology (가상현실기술을 이용한 자세균형재활훈련에 관한 연구)

  • Lee, J.S.;Jeong, J.S.;Kim, D.W.;Kim, N.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.256-259
    • /
    • 1996
  • In this paper, we proposed a new system for postural balance rehabilitation training. We used the cycle simulator using virtual reality technology as the sensory integration device. Our results showed that this system was effective postural balance rehabilitation training device and might be useful as the clinical equipment.

  • PDF

Development of Non-contact Home Monitoring System for Infant Respiration to Prevent SIDS (영아 돌연사 방지를 위한 비접촉 방식의 가정용 영아 호흡 감시 시스템 개발)

  • Heo, Il-Kang;Myoung, Hyoun-Seok;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.2
    • /
    • pp.48-53
    • /
    • 2015
  • Sudden infant death syndrome(SIDS) continues to be general cause of infant death. Also, apnea is supposed to be one of the main risk factor of SIDS. Therefore, Infant's respiratory monitoring and real-time apnea detection is very important to prevent SIDS. In this study, we proposed a non-contact home monitoring system for infant's respiration using Doppler radar in order to prevent SIDS. The respiration data were acquired from a commercialized baby simulator(Simbaby$^{TM}$) using a Doppler radar. To evaluate a performance of the proposed system, the simulator was placed in a supine and prone position and the chest belt was used simultaneously as a reference signal. As a result, correlation coefficients between respiration rates of Doppler radar and the chest belt in each position were 0.95(p < 0.001) and 0.98(p < 0.001), respectively. The averages of difference were $-0.29{\pm}5.21(mean{\pm}1.96{\cdot}$ standard deviation) in supine and $-0.12{\pm}3.05$ in prone from Bland-Altman analysis. The results indicated an excellent performance in detecting apnea with a sensitivity of 100% and a positive predictive value of 100% in each posture respectively. These results demonstrated that a proposed Doppler radar system is suitable for non-contact respiratory monitoring in order to prevent SIDS of infant.

Comparison of Machine Learning Classification Models for the Development of Simulators for General X-ray Examination Education (일반엑스선검사 교육용 시뮬레이터 개발을 위한 기계학습 분류모델 비교)

  • Lee, In-Ja;Park, Chae-Yeon;Lee, Jun-Ho
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.111-116
    • /
    • 2022
  • In this study, the applicability of machine learning for the development of a simulator for general X-ray examination education is evaluated. To this end, k-nearest neighbor(kNN), support vector machine(SVM) and neural network(NN) classification models are analyzed to present the most suitable model by analyzing the results. Image data was obtained by taking 100 photos each corresponding to Posterior anterior(PA), Posterior anterior oblique(Obl), Lateral(Lat), Fan lateral(Fan lat). 70% of the acquired 400 image data were used as training sets for learning machine learning models and 30% were used as test sets for evaluation. and prediction model was constructed for right-handed PA, Obl, Lat, Fan lat image classification. Based on the data set, after constructing the classification model using the kNN, SVM, and NN models, each model was compared through an error matrix. As a result of the evaluation, the accuracy of kNN was 0.967 area under curve(AUC) was 0.993, and the accuracy of SVM was 0.992 AUC was 1.000. The accuracy of NN was 0.992 and AUC was 0.999, which was slightly lower in kNN, but all three models recorded high accuracy and AUC. In this study, right-handed PA, Obl, Lat, Fan lat images were classified and predicted using the machine learning classification models, kNN, SVM, and NN models. The prediction showed that SVM and NN were the same at 0.992, and AUC was similar at 1.000 and 0.999, indicating that both models showed high predictive power and were applicable to educational simulators.

A Development of an Acupoints Education Table using 3D Technology and Augmented Reality (경혈 교육을 위한 3D 및 증강현실 기술을 활용한 한의학 통합교육 테이블 개발)

  • Yang, SeungJeong;Ryu, ChangJu;Kim, SangCheol;Kim, JaeSouk
    • Korean Journal of Acupuncture
    • /
    • v.38 no.4
    • /
    • pp.267-274
    • /
    • 2021
  • Objectives : Acupoints education is important in that it can determine the clinical competency of Korean Medicine Doctors (KMDs). Accordingly, we aimed to develop a practical simulator for acupoints education, acupoints training, acupoints practice, and acupoints evaluation. Methods : Korean Medicine (KM) SMART Table can be divided into hardware, server and components, and is organically linked. We develop KM SMART Table that combines the hardware of a human-sized table with a UHD display capable of multi-touch in two cases and software that can teach acupoints. We make Augmented Reality (AR) contents linked with KM SMART Table contents and develop applications that can use contents using mobile devices. By developing an AR image tracking module to react with KM SMART Table, it enables acupoint learning according to the mobile device platform and human anatomy. Results : The current system is a prototype where some 3D technology has been implemented, but the AR function will be produced later. New learning using 3D and AR will be required during acupoints education and acupoints practice. It will be used a lot in OSCE (Objective Structured Clinical Examination) practices for strengthening the competency of KMDs, and it will be of great help not only in KM education as a unique simulator of KM, but also in the practice of acupuncture and chuna for musculoskeletal diseases. Conclusions : The KM SMART Table is a technology that combines 3D and AR to learn acupoints, and to conduct acupoints OSCE practice, and we suggest that it can be usefully used for educational evaluation.

A Digital Twin-based Approach for VANET Simulation in Real Urban Environments

  • Jonghyeon Choe;Youngboo Kim;Sangdae Kim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.8
    • /
    • pp.113-122
    • /
    • 2024
  • In this paper, we conducted a thorough investigation of existing simulators for running simulations of Vehicular Adhoc Networks (VANET) in realistic road environments, such as digital twins. After careful consideration, we chose a simulator that combines OSM (OpenStreetMap), SUMO (Simulation of Urban MObility), and OMNeT++ due to its open-source nature and efficient performance. Using this integrated simulator, we carried out VANET simulations in both simple virtual road environments and realistic road environments. Our findings revealed significant differences in VANET performance between the two types of environments, emphasizing the need to consider realistic road and traffic environments for reliable VANET operation. Furthermore, our simulations demonstrated significant performance variability, with performance degradation observed as vehicle density decreased and dynamic changes in network topology increased. These results underscore the importance of digital twin-based approaches in VANET research, highlighting the need to simulate real-world road and traffic conditions rather than relying on simple virtual road environments.

Characteristic Study of the Pulse Position on CHON, KWAN and CHUCK Using the Ultrasonic Waves (초음파 분석을 이용한 촌관척 위치별 혈관의 특성연구)

  • Lee, Yu-Jung;Lee, Jeon;Lee, Hae-Jung;Ryu, Hyun-Hee;Choi, Eun-Ji;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.111-117
    • /
    • 2007
  • The study aims to measure and analyze the thickness and depth of blood vessel on the pulse diagnosis locations and the blood velocity through the use of ultrasonic waves (LOGIQ5PRO, GE Medical, U.S.) in order to understand the structural difference of pulse diagnosis locations. The subjects included 44 healthy men and women(22.28${\pm}$2.62 age) considered normal in terms of Body Mass Index(BMI). The thickness and depth of the blood vessel and the blood velocity were measured three times on CHON, KWAN and CHUCK to obtain the average value. Results showed there is a statistically significant difference among the variables measured on CHON, KWAN and CHUCK. A difference according to gender was also observed. This explains why an oriental medical doctor can tell the difference in pulses depending on the location of CHON, KWAN and CHUCK. In addition, the difference in pressure between CHON and KWAN was higher than that in pressure between KWAN and CHUCK. The findings explain why oriental medical doctors take pulses by dividing CHON, KWAN and CHUCK in the short length of the three fingers. It can be used to develop a pulse diagnosis device enabling accurate measurement according to the characteristics of blood vessel structure based on where the pulse is taken. Furthermore, the results can be used as basic data for the development of a pulse diagnosis simulator.

  • PDF

Channel Selection Method of Wireless Sensor Network Nodes for avoiding Interference in 2.4Ghz ISM(Industrial, Scientific, Medical) Band (2.4Ghz ISM(Industrial Scientific Medical) 밴드에서 간섭을 회피하기 위한 무선 센서 노드의 채널 선택 방법)

  • Kim, Su Min;Kuem, Dong Hyun;Kim, Kyung Hoon;Oh, Il;Choi, Seung Won
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.4
    • /
    • pp.109-116
    • /
    • 2014
  • In recent, ISM (Industrial Scientific Medical) band that is 2.4GHz band authorized free of charge is being widely used for smart phone, notebook computer, printer and portable multimedia devices. Accordingly, studies have been continuously conducted on the possibility of coexistence among nodes using ISM band. In particular, the interference of IEEE 802.11b based Wi-Fi device using overlapping channel during communication among IEEE 802.15.4 based wireless sensor nodes suitable for low-power, low-speed communication using ISM band causes serious network performance deterioration of wireless sensor networks. This paper examined a method of identifying channel status to avoid interference among wireless communication devices using IEEE 802.11b (Wi-Fi) and other ISM bands during communication among IEEE 802.15.4 based wireless sensor network nodes in ISM band. To identify channels occupied by Wi-Fi traffic, various studies are being conducted that use the RSSI (Received Signal Strength Indicator) value of interference signal obtained through ED (Energy Detection) feature that is one of IEEE 802.15.4 transmitter characteristics. This paper examines an algorithm that identifies the possibility of using more accurate channel by mixing utilization of interference signal and RSSI mean value of interference signal by wireless sensor network nodes. In addition, it verifies such algorithm by using OPNET Network verification simulator.