• Title/Summary/Keyword: Medical Imaging Equipment

Search Result 144, Processing Time 0.024 seconds

Modified Spatial Division Average Filter for AWGN Noise Reduction (AWGN 잡음 제거를 위한 변형된 공간분할 평균필터)

  • Park, Hwa-Jung;Kwon, Mi-Rae;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.227-229
    • /
    • 2021
  • The modern society is advancing from the analog era to the digital imaging era, and in line with the trend of this era, various imaging devices such as exploration robots, medical equipment, and CCTV are helping our daily life a lot. However, noises caused by various causes in digital images not only cause image deterioration, but also deteriorate and deteriorate image quality. A typical noise is AWGN, and types of filters to remove it include an average filter, a median filter, and an alpha-trimmed average filter, but these filters have a disadvantage in that they show somewhat inadequate noise reduction performance in the high frequency region. Therefore, in this paper, a modified spatial division average filter based on standard deviation is proposed to effectively reduce AWGN existing in the high frequency region of the image.

  • PDF

Imaging Characteristics of Computed Radiography Systems (CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가)

  • Jung, Ji-Young;Park, Hye-Suk;Cho, Hyo-Min;Lee, Chang-Lae;Nam, So-Ra;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.63-72
    • /
    • 2008
  • With recent advancement of the medical imaging systems and picture archiving and communication system (PACS), installation of digital radiography has been accelerated over past few years. Moreover, Computed Radiography (CR) which was well established for the foundation of digital x-ray imaging systems at low cost was widely used for clinical applications. This study analyzes imaging characteristics for two systems with different pixel sizes through the Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE). In addition, influence of radiation dose to the imaging characteristics was also measured by quantitative assessment. A standard beam quality RQA5 based on an international electro-technical commission (IEC) standard was used to perform the x-ray imaging studies. For the results, the spatial resolution based on MTF at 10% for Agfa CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.9 cycles/mm and 2.8 cycles/mm, respectively. The spatial resolution based on MTF at 10% for Fuji CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.4 cycles/mm and 3.2 cycles/mm, respectively. There was difference in the spatial resolution for $14{\times}17$ inches, although radiation dose does not effect to the MTF. The NPS of the Agfa CR system shows similar results for different pixel size between $100{\mu}m$ for $8{\times}10$ inch I.P and $150{\mu}m$ for $14{\times}17$ inch I.P. For both systems, the results show better NPS for increased radiation dose due to increasing number of photons. DQE of the Agfa CR system for $8{\times}10$ inch I.P and $14{\times}17$ inch I.P resulted in 11% and 8.8% at 1.5 cycles/mm, respectively. Both systems show that the higher level of radiation dose would lead to the worse DQE efficiency. Measuring DQE for multiple factors of imaging characteristics plays very important role in determining efficiency of equipment and reducing radiation dose for the patients. In conclusion, the results of this study could be used as a baseline to optimize imaging systems and their imaging characteristics by measuring MTF, NPS, and DQE for different level of radiation dose.

  • PDF

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment (진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구)

  • Heo, Yeji;Kim, Kyotae;Noh, Sicheul;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.105-110
    • /
    • 2014
  • Diagnostic radiation equipment diagnosis and treatment of disease of recent plays a central role, but this is based on the assumption of an appropriate balance of benefits and risks of diagnostic. If balance is not maintained has the potential to give an adverse effect on the health of the public. In the case of an overseas, the importance of (QA) quality assurance of medical equipment is growing, but evaluation criteria of quality assurance has not been clearly presented in domestic. Therefore, the modernization of medical equipment from the point at which the degree of cycle-by-cycle management system of foreign national to be suitable for diagnostic radiation generator entry and quality control standards by introducing a tailoring is necessary. In this study the most frequently used diagnostic radiation generator X-ray imaging apparatus of the general three-year periodic inspections at any time between the periodic inspection items and quality control methods and standards for the establishment of the United States, Canada and abroad, and international electronic literature search Technical Committee (International Electro-technical Commission, IEC) were compared with the provisions of item. Based on the national quality control items when opening frequent inspection items and standards presented as a basis for setting up study.

A Study on Enacting the Radiologic Technologist Act for the Civil Right to Health in Korea (건강권과 방사선사법 제정에 관한 고찰)

  • Lim, Chang-Seon
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.313-320
    • /
    • 2007
  • There are the Medical Radiation Health and Safety Act(the Patient Radiation Health and Safety Act, the Radiologic Technologist Act), the Medical Laboratory Technologist Act, the Physical Therapy Practice Act, and the Dental Hygienist Act, etc in America. However, Korea has only one Act for a medical radiologic technologist(including radiation therapy technologist, nuclear medicine technologist), medical laboratory technologist, physical therapist, occupational therapy examiner, dental hygienist, and so on. It is the Medical Technologist Act. Therefore, the Medical Radiation Health and Safety Act for a radiologic technologist(including radiation therapy technologist, nuclear medicine technologist) has to be enacted independently in Korea. It is the purpose of this Act to provide for the appropriate certification of persons using radioactive materials, equipment emitting ionizing radiation on humans or performing medical imaging for diagnostic and therapeutic purposes. In Korea, the radiologic technologist is a "fusion technologist" who is a person other than a licensed practitioner as a radiographer, radiation therapist, nuclear medicine technologist, computed tomography technologist, magnetic resonance technologist, mammographer, sonographer, medical dosimetrist, quality management technologist, etc. This Act will have some provisions related to the definitions, reserved title, scope of practice, specialized technologist, application for licensure, radiologic technology council, renewal, continuing education, the radiation control advisory commission, etc. This Act will ensure that quality radiation therapy treatments are delivered and that quality diagnostic information is presented for interpretation, which will lead to accurate diagnosis, treatment and cure. Accurate diagnosis can be provided only when a personnel is properly educated in technique, equipment operation and radiation safety. In the end, this Act will protect the civil right to health. By regulating the personnel responsible for performing those procedures, this Act will mean improved care for patients-higher quality images, improved accuracy, and less exposure to radiation.

  • PDF

Clinical Application of SPECT and PET in CerebroVascular Disease (뇌혈관질환에서 SPECT와 PET의 임상적 응용)

  • Ra, Young-Shin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.1
    • /
    • pp.1-12
    • /
    • 2003
  • Single photon emission computed tomography(SPECT) and positron emission tomography(PET) are modern imaging techniques that allow for both qualitative and quantitative assessment of hemodynamic changes in cerebrovascular diseases. SPECT has been becoming an indispensable method to investigate regional cerebral blood flow because equipment and isotope are easily available in most general hospitals. Acetazolamide stress SPECT has also been proved to be useful to evaluate the cerebrovascular reserve of occlusive cerebrovascular diseases and to select surgical candidate. PET has gained wide spread clinical use in the evaluation of the hemodynamic and metabolic consequences of extracranial or intracranial arterial obstructive disease despite its complexity and limited availability. PET has been established as an invaluable tool in the pathophysilogy investigation of acute ischemic stroke. The potentials, limitations, and clinical applications of SPECT and PET in various cerebrovascular diseases will be discussed in this article with reviews of literatures.

A Study on the Setting of Examination Limits for Radiographers in Medical Institutions (의료기관 내 방사선사의 검사 한도 설정에 관한 연구)

  • Jeong-Ho Kim;Gap-Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.401-410
    • /
    • 2023
  • A radiographer is a job in charge of diagnostic imaging equipment, and must contribute to the promotion of public health by suggesting an appropriate level of work. To this end, we intend to present an appropriate level of work through evaluation of human harm according to work, statistical evaluation through questionnaires, and domestic and international trends. In the case of human harm evaluation, considering radiation exposure, 42.6%, shield work, 69.7%, and in the case of magnetic resonance imaging, the maximum length of stay in the examination room should be adjusted to 15 minutes and not exceed 30 times. According to the survey statistics, it was confirmed that the physical and mental burden increased due to the high workload and difficulty compared to working hours. Based on domestic and international trends, it is necessary to adjust the examination standards for domestic radiographers to 36.8% to promote national health through qualitative improvement of radiological examinations. something to do.

AC Servo System Design of Digital Radiography Equipment (디지털 방사선 검사장치(DR)의 AC 서보 시스템 설계)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.3
    • /
    • pp.133-138
    • /
    • 2022
  • Digital radiation inspection equipment is a medical device that deals with human life and requires stability and high reliability. However, this system is currently the most advanced technology and the domestic market is almost occupied by European products including Japan. Therefore, research and development are needed not only to replace domestic medical devices, which are largely dependent on expensive imported products, but also to develop more economical and user-oriented products that are easy to operate and produce devices that lead to accurate diagnosis. In particular, among the digital X-ray systems, the motor driving technology and the mechatronics technology related to the development of mechanical devices have matured to some extent in Korea. In this paper, selection of AC servomotor for digital radiation inspection suitable for imaging purpose, and application of conversion device and control method to check performance and improve problems.

Should Korean Medicine doctors use modern diagnostic medical devices? Survey result of public perspectives (국민인식을 기초로 한의사의 현대 진단의료기기 사용 법제화 필요성에 대한 제언 : 설문조사를 중심으로)

  • Juchul Kim;Byoungcheun Hwang;Manki Hwang;Seungmin Kathy Lee;EunHee Yi;Jungtae Leem
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.94-105
    • /
    • 2022
  • Objectives: This study investigated public opinion on the use of modern diagnostic medical devices by Korean Medicine doctors. Methods: A questionnaire looking into perceptions on the use of modern medical devices was developed. It was distributed by a third party and data was collected. Results were analyzed through frequency analysis, chi-square analysis (χ2-test), frequency and cross analysis using R program. The measurement variable in the study was the respondent's perspectives and expectations on the use of modern diagnostic medical devices by Korean Medicine doctors. The maximum significance level was 0.05. Results: There were a total of 3,000 responses and 80.8% of the respondents replied that there is a need for government-level discussion on endowing rights to Korean Medicine doctors as supervisors for safety management of radiation generating devices. Also, 83.3% of the respondents agreed the use of ultrasound imaging equipment in Korean Medicine clinics should be legalized. Conclusions: According to this study, respondents strongly support the use of modern diagnostic medical devices by Korean Medicine doctors. This is the first study to investigate public opinion in this area and it provides a significant insight into the public needs and desires for a wider scope of practice for Korean Medicine in the healthcare system.

A Study on Production and Its Usefulness of AAPM TG18 Guiding Instrument for Diagnostic Monitor QC (영상의학 검사 판독용 모니터 정도관리 Guiding Instrument 제작과 유용성 고찰)

  • Son, Gi-Gyeong;Sung, Dong-Wook;Jeong, Jae-Ho;Kang, Hui-Doo;Ryu, Kyung-Nam
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2008
  • Diagnostic display monitor QA according to AAPM TG18 is usually performed by PACS administrator, product manager and reading doctor, and for acceptance testing and periodic quality control evaluation, a combination of visual and quantitative tests can be used, as outlined in sections 5 and 6 of 'assessment of display performance for medical imaging systems'. Although many display tests can be performed visually, a more objective and quantitative evaluation of display performance requires special test tools. The required instruments vary in their complexity and cost, depending on the context of the evaluation(research, acceptance testing, or quality control) and how thorough the evaluation needs to be. Objective and reliable assessment of many display characteristics can be performed with relatively inexpensive equipment, So, we made 'AAPM TG18 guiding instrument' to ues variable purpose of the evaluation of 'geometrical distortions(quantitative"', 'veiling glare(visual)' and 'sensor calibration'. The spatial measurements for the quantitative evaluation of geometric distortions, and the measurement of the veling-glare ring response function which provides information regarding the spatial extent of the luminance spread, can be performed using the TG18 guiding instrument can be used to sensor calibration to standardize the basic rate of 0% luminance when periodic calibration.

  • PDF