• 제목/요약/키워드: Medical Image Segmentation

검색결과 256건 처리시간 0.028초

Evaluation of Hippocampal Volume Based on Various Inversion Time in Normal Adults by Manual Tracing and Automated Segmentation Methods

  • Kim, Ju Ho;Choi, Dae Seob;Kim, Seong-hu;Shin, Hwa Seon;Seo, Hyemin;Choi, Ho Cheol;Son, Seungnam;Tae, Woo Suk;Kim, Sam Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권2호
    • /
    • pp.67-75
    • /
    • 2015
  • Purpose: To investigate the value of image post-processing software (FreeSurfer, IBASPM [individual brain atlases using statistical parametric mapping software]) and inversion time (TI) in volumetric analyses of the hippocampus and to identify differences in comparison with manual tracing. Materials and Methods: Brain images from 12 normal adults were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) with a slice thickness of 1.3 mm and TI of 800, 900, 1000, and 1100 ms. Hippocampal volumes were measured using FreeSurfer, IBASPM and manual tracing. Statistical differences were examined using correlation analyses accounting for spatial interpretations percent volume overlap and percent volume difference. Results: FreeSurfer revealed a maximum percent volume overlap and maximum percent volume difference at TI = 800 ms ($77.1{\pm}2.9%$) and TI = 1100 ms ($13.1{\pm}2.1%$), respectively. The respective values for IBASPM were TI = 1100 ms ($55.3{\pm}9.1%$) and TI = 800 ms ($43.1{\pm}10.7%$). FreeSurfer presented a higher correlation than IBASPM but it was not statistically significant. Conclusion: FreeSurfer performed better in volumetric determination than IBASPM. Given the subjective nature of manual tracing, automated image acquisition and analysis image is accurate and preferable.

식도염 진단을 위한 영상 판별분석 (Image Discriminal Analysis for Detecting a Esophagitis)

  • 서광욱;이창우;김웅;이소연;이대원
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.545-550
    • /
    • 2004
  • 디지털 내시경 영상에서 식도염 등의 이상부위를 검출하기 위하여 임상 영상의 색상과 텍스쳐 인자에 대한 정보를 얻은 후 판별분석에 의해 영상의 이상부위론 인식하 수 있는 영상처리 알고리즘을 개발하였다. 이 알고리즘을 개발하기 위하여 여러 가지 영상처리 인자들 중에서 어떠한 인자들이 정상과 이상 부위를 구별할 수 있는 중요한 특징 인자가 되는지를 구명하였다. 이 특징 인자들을 이용하여 식도염의 중요한 진단기준이라 할 수 있는 미란 및 궤양에 대한 검출을 수행하였다. 이를 검증하기 위하여 20개의 영상 이미지를 사용하였으며 판별분석의 알고리즘을 사용할 때 보정단계와 검증단계의 성공률은 각각 92.8%와 92.4%를 나타내었다.

영역 분할을 이용한 변형된 스위칭 필터에 관한 연구 (A Study on Modified Switching Filter Using Region Segmentation)

  • 권세익;김남호
    • 한국통신학회논문지
    • /
    • 제41권10호
    • /
    • pp.1284-1289
    • /
    • 2016
  • 최근, 디지털 영상처리는 방송, 통신, 컴퓨터 그래픽, 의학 분야 등에서 많이 응용되고 있으며, 일반적으로 영상 데이터는 전송하는 과정에서 잡음이 발생한다. 영상에 첨가되는 잡음에는 다양한 종류가 있으며, salt and pepper 잡음, AWGN, 복합잡음이 대표적이다. 따라서 본 논문에서는 영상에 첨가된 복합잡음의 영향을 완화하기 위하여 훼손된 영상을 네 개의 영역으로 세분화하고 각 화소들의 잡음 종류를 추정하여 salt and pepper 잡음과 AWGN으로 나누어 처리하는 스위칭 필터를 제안하였다. 국부 마스크의 중심화소가 salt and pepper 잡음에 훼손된 경우, 세분화된 영역의 히스토그램 확률 가중치 마스크를 이용하여 처리하였으며, AWGN으로 훼손된 경우, 세분화된 영역의 분산을 이용하여 각 영역의 분산에 따라 가중치를 다르게 적용하여 가중치 필터를 제안하였다. 그리고 제안한 필터의 성능 평가를 위해 PSNR을 이용하여 기존의 방법들과 비교하였다.

수술 동영상의 비식별화를 위한 개인식별정보 자동 검출 시스템 설계 및 구현 (Design and Implementation of Automated Detection System of Personal Identification Information for Surgical Video De-Identification)

  • 조영탁;안기옥
    • 융합보안논문지
    • /
    • 제19권5호
    • /
    • pp.75-84
    • /
    • 2019
  • 최근 의료정보기술 분야에서 비디오는 풍부한 임상정보를 포함하는 특징으로 인하여 새로운 서비스 창출 및 연구개발을 위한 중요한 데이터로서 그 가치를 새롭게 평가받고 있다. 그러나 임상정보는 개인정보를 포함하고 있어, 생명윤리 혹은 연구 윤리에 대한 고려가 필요하다. 따라서 비디오 또한 의료영상으로서 비식별화가 요구되지만 기존 방법은 주로 정형데이터와 정지영상에 특화되어 기존의 방법을 그대로 적용하기 어려운 문제가 있다. 본 논문에서는 개인정보 비식별화 처리 시스템과의 연동을 고려하여 비디오 내에서 개인식별정보를 검출하는 자동화 시스템을 제안한다. 제안 시스템은 장면분할과 체내외 영역 검출의 전처리 후에 텍스트 및 사람검출을 통한 인덱싱과정을 수행한다. 검출된 개인식별 인덱스 정보는 비식별화를 수행하는 외부 시스템 및 시각화를 위한 메타데이터로 제공된다. 제안 시스템의 효용성을 검증하기 위하여 프로토타입을 구현하고 실제 수술비디오를 대상으로 인덱싱 속도를 측정하였다. 그 결과 입력 비디오의 재생시간 대비 2배 이상의 빠른 작업속도를 보였으며, 수술교육콘텐츠 제작 및 학술용 반자동 편집시스템의 사례를 통해 빠른 의사결정을 보조할 수 있음을 확인하였다.

Classification of Leukemia Disease in Peripheral Blood Cell Images Using Convolutional Neural Network

  • Tran, Thanh;Park, Jin-Hyuk;Kwon, Oh-Heum;Moon, Kwang-Seok;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • 한국멀티미디어학회논문지
    • /
    • 제21권10호
    • /
    • pp.1150-1161
    • /
    • 2018
  • Classification is widely used in medical images to categorize patients and non-patients. However, conventional classification requires a complex procedure, including some rigid steps such as pre-processing, segmentation, feature extraction, detection, and classification. In this paper, we propose a novel convolutional neural network (CNN), called LeukemiaNet, to specifically classify two different types of leukemia, including acute lymphoblastic leukemia (ALL) and acute myeloid leukemia (AML), and non-cancerous patients. To extend the limited dataset, a PCA color augmentation process is utilized before images are input into the LeukemiaNet. This augmentation method enhances the accuracy of our proposed CNN architecture from 96.9% to 97.2% for distinguishing ALL, AML, and normal cell images.

영역확장법과 동적외곽선모델을 이용한 해마(hippocampus)의 외곽선 검출 (Contour detection of hippocampus using Dynamic Contour Model and Region Growing)

  • 장동표;김효대;이두수;김선일
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.116-118
    • /
    • 1997
  • In hippocampal morphology Abnormalities, including unilateral or bilateral volume loss, are known to occur in epilepsy, Alzheimer's disease, and in certain amnestic syndromes. To detect such abnormalities in hippocampal morphology, we present a method that combines region growing and dynamic contour model to detect hippocampus from MRI brain data. The segmentation process is performed two steps. First region growing with a seed point is performed in the region of hippocampus and the initial contour of dynamic contour model is obtained. Second, the initial contour is modified on the basis of criteria that integrate energy with contour smoothness and the image gradient along the contour. As a result, this method improves fairly sensitivity to the choice of the initial seed point, which is often seen by conventional contour model. The power and practicality of this method have been tested on two brain datasets. Thus, we have developed an effective algorithm to extract hippocampus from MRI brain data.

  • PDF

다해상도 변형 모델을 이용한 3차원 경계분할 (Three-dimensional Boundary Segmentation using Multiresolution Deformable Model)

  • 박주영;김명희
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2000년도 봄 학술발표논문집 Vol.27 No.1 (B)
    • /
    • pp.592-594
    • /
    • 2000
  • 변형모델(deformable model)은 볼륨의료영상(volumetric medical image)으로부터 복잡한 인체기관의 3차원적 경계를 분할해내기 위해 효과적인 방법을 제공한다. 그러나, 기존 변형모델은 초기와 의존성, 오목한 경계(concavity) 분할의 비적합성, 그리고 모델내 요소간 자체교차(self-intersection)의 제한점을 가지고 있었다. 본 연구에서는 이러한 제한점을 극복하고, 오목한 구조를 포함하는 복잡한 인체기관의 경계를 분할하기에 적합한 새로운 변형모델을 제안하였다. 제안한 변형모델은 볼륨영상 피라미드(pyramid)를 기반으로 다해상도(multiresolution)의 모델 정제화(refinement)를 수행한다. 다해상도 모델 정제화는 전역적 시셈플링(global resampling) 및 지역적 리샘플링(local resampling)를 통하여 저해상도의 모델로부터 점차 고해상도의 모델로 이동하면서 객체의 경계를 계층적으로 분할해가는 방법이다. 다해상도 모델에 의한 계층적 경계 분할은 초기화 조건에의 의존성을 극복할 수 있게할 뿐 아니라, 빠른 속도로 원하는 객체의 경계에 수렴할 수 있게 한다. 또한 지역적 리샘플링은 모델 구성요소의 정규화를 수행함으로써 객체의 오목한 부분을 성공적으로 분할할 수 있게 한다. 그리고, 제안 모델은 기존 변형모델에서 포함하는 내부 힘(internal force)과 외부 힘(external force)외에 자체교차방지 힘(non-self-intersection force)을 추가함으로서 효과적으로 모델내의 자체교차를 방지할 수 있게 하였다.

  • PDF

AWGN 제거를 위한 합성 필터에 관한 연구 (A Study on Composite Filter for AWGN Removal)

  • 권세익;황용연;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.684-686
    • /
    • 2017
  • 현재, 영상처리는 군사, 의료, 산업 등의 넓고 다양한 분야에서 활용되고 있으며, 영상에 첨가된 잡음은 영상의 질을 저하시키다. 따라서, 잡음 제거는 영상 인식, 에지 검출, 영상 분할 등의 영상 처리를 수행하기 전에 필수적인 과정이다. 이러한 영상에 첨가된 잡음을 제거하기 위한 연구가 활발히 진행되고 있으며, 영상에 첨가되는 잡음에는 AWGN(additive white Gaussian noise)이 대표적이다. 본 논문에서는 영상에 첨가된 AWGN을 완화하기 위해, 에지 검출 및 표준편차를 이용한 필터를 합성하여 처리하는 알고리즘을 제안하였다.

  • PDF

Cs-137 점선원을 이용한 감쇠보정기법들에 대한 평가 (Assessment of Attenuation Correction Algorithms With a $^{137}$Cs Point Source)

  • 봉정균;김희중;박해정;권윤영;손혜경;윤미진;이종두;정해조
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.96-99
    • /
    • 2004
  • 본 연구는 전신 GSO PET 스캐너를 사용하여 Cs-137 투과 선원을 이용한 감쇠보정기법들을 평가하는 것이다. 이를 위하여, 4개의 모양이 다른 팬텀들을 사용하여 감쇠보정기법들을 검사하였다. 뇌영상을 위하여 256 mm의 시야가 사용되었고, 약 110MBq의 F-18 선원이 팬텀실험을 위해 사용되었다. 감쇠를 보정하기위해서, 방출선원이 팬텀에 주입된 후, Cs-137점선원의 투과 스캔 데이터가 획득되었다. 방출선원 데이터는 산란보정을 하였고, 4가지 종류의 감쇠보정기법을 이용하여 감쇠보정을 하였다. 재구성된 팬텀 영상들이 비교평가되었고, 임상 뇌영상은 핵의학 의사들이 평가를 하였다. 결과적으로 균일성 평가를 위한 원형팬텀의 영상에서, 측정감쇠보정기법을 이용시 가운데 부분이 떨어져 보였으나, 나머지 감쇠보정 기법들에서는 균일하게 보였다. 임상 뇌 데이터의 경우, 두개골에 대한 감쇠 효과를 볼 수 있었고, 두개골에 대한 감쇠보정이 적용되지 않은 영상에서는 인공산물이 발생하는 것을 보여주었다. 결론적으로, 정량적 뇌영상에 대한 정확도를 높이기 위해서, 두개골에 대한 감쇠보정이 적용된 개선된 감쇠보정 방법이 요구되어진다. 본 연구는 앞으로 Cs-137 점선원을 이용한 감쇠보정기법이 포함된 뇌 PET 영상 장치를 개선하는데 유용할 것으로 사료된다.

  • PDF

Topology Correction for Flattening of Brain Cortex

  • Kwon Min Jeong;Park Hyun Wook
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권2호
    • /
    • pp.73-86
    • /
    • 2005
  • We need to flatten the brain cortex to smooth surface, sphere, or 2D plane in order to view the buried sulci. The rendered 3D surface of the segmented white matter and gray matter does not have the topology of a sphere due to the partial volume effect and segmentation error. A surface without correct topology may lead to incorrect interpretation of local structural relationships and prevent cortical unfolding. Although some algorithms try to correct topology, they require heavy computation and fail to follow the deep and narrow sulci. This paper proposes a method that corrects topology of the rendered surface fast, accurately, and automatically. The proposed method removes fractions beside the main surface, fills cavities in the inside of the main surface, and removes handles in the surface. The proposed method to remove handles has three-step approach. Step 1 performs smoothing operation on the rendered surface. In Step 2, vertices of sphere are gradually deformed to the smoothed surfaces and finally to the boundary of the segmented white matter and gray matter. The Step 2 uses multi-resolutional approach to prevent the deep sulci from geometrical intersection. In Step 3, 3D binary image is constructed from the deformed sphere of Step 2 and 3D surface is regenerated from the 3D binary image to remove intersection that may happen. The experimental results show that the topology is corrected while principle sulci and gyri are preserved and the computation amount is acceptable.