• Title/Summary/Keyword: Medical Engineering

Search Result 8,937, Processing Time 0.042 seconds

Study on low-level laser therapy device according to the obesity development (비만치료기 개발에 따른 저준위레이저에 관한 연구)

  • Lee, Sang-sik;Kim, Jun-tae;Jeong, Jin-hyoung;Kim, Nam-Sun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.1
    • /
    • pp.82-89
    • /
    • 2016
  • And by entering into an aging society with economic growth "beautiful and healthy desire to live', aesthetics industry as promote interest in 'Anti-aging' is emerging as a promising business increased significantly the skin care market. However, the management of the hospital or the temporal order to receive professional care providers, spatial, and cost constraints caused many companies to solve this problem began to approach the Home Care Area. Global trends in personal skin care market has been activated, the domestic has been activated at low cost, private market due to the recession. We have performed this test in order to develop a skin care device for home in order to compensate for this point.In this paper, we develop a low-level laser to create a personal skin care products and sought to incorporate them into the skin cosmetic.Expand the pores by using the low-level laser to the skin by to the dermal layer of the skin was penetrated aim experiment the ampoule, and by a comparison of the medical low-level laser reliability and determine the effectiveness or absence of the performance and efforts to commercialize.

Identification of Voice for Listeners who Feel Favor Using Voice Analysis (음성 분석을 이용한 청자가 호감을 느끼는 목소리에 대한 규명)

  • Choi, Ji Hyun;Cho, Dong Uk;Jeong, Yeon Man
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.1
    • /
    • pp.122-131
    • /
    • 2016
  • In the smart societies, such as the current unlike in the past, the voice that listeners will feel favor is changing through the development of ICT technologies and infrastructure. In other words, in the past, loud, intensive and fast voice is a favorite but now a new social and cultural situation that is changing them with ICT technologies. Now, this becomes one of the important things that we clarify 'Is it a voice that feels a favor?'. For this, in this paper, we identified what voice that listeners feel favor by applying ICT technologies. Studies were carried out to proceed largely divided into two categories. Firstly, as the quantified data, we extracted the impact on favorable feeling of listeners which related with emotional speech by empirical analysis work. To do this, we performed the experiment for the public. Secondly, we identified what kind of voice which listeners feel a good impression. For this, we identified voice characteristics that there are people who are influential in the real society. Also, we extracted both the voice characteristics of each influential people and common voice characteristics. In addition, we want to overcome the problems of qualitative methods that have originally limitations in objective respects which is significant to the voice analysis. For this, we performed the experiments of the voice analysis by numerical and visual approaches.

Relationship between Oxygen Uptake and Cardiac Output on Maximal Treadmill Exercise in Marathoners by Improved Impedance Cardiography (Treadmill 최대 운동시 Impedance 심장기록법의 개선에 의한 마라톤 선수의 심박출량과 산소소비량과의 관계)

  • Kang, Doo-Hee;Hwang, Soo-Kwan;Yeon, Dong-Soo;Yuh, Seon-Hee;Kim, Deok-Won
    • The Korean Journal of Physiology
    • /
    • v.24 no.2
    • /
    • pp.249-260
    • /
    • 1990
  • Maximal cardiac output and oxygen uptake $(VO_{2max})$ were measured during treadmill exercise for seven top-class marathoners and nine non-athletes using impedance cardiograph developed by one of the authors (DW Kim). Results of this study are summarized as belows. 1) New shoes with sponge and silicon rubber attached to the soles were developed to reduce motion artifact during treadmill exercise. Ensemble everaging techneque with the developed shoes was also used to improve the measurement of stroke volume using impedance cardiography. 2) Maximal cardiac output of the athletes, 14.98 L/min, was significantly higher than that of the non-athletes, 13.46 L/min. As maximal heart rate of the marathoners is lower than that of non-athletes, stroke volume of the former is significantly larger than that of the latter. 3) $VO_{2max}$ of the marathoners, 59.38 ml/kg/min, was higher than that of the non-athletes, 40.22 ml/kg/min. At the anaerobic threshold. $VO_{2max}$ of the former was 62.3% of $VO_{2max}$ and this was significantly higher than that of the non-athletes, 57.2%, This results indicates that the marathoners have higher aerobic capacity than the non-athletes. 4) The marathoners showed larger $VO_2$ than the non-athletes at the same cardiac output, indicating that a-v $O_2$ of the former is higher than that of the latter. 5) Maximal systolic pressure of the marathoners was higher than that of the non-athletes, and so was maximal rate-pressure products. These results indicate that heart oxygen consumption rate $(hVO_2)$ of the marathoner is higher than that of the non-athletes is mainly due to higher stroke volume. And higher oxygen consumption of the marathoners is due to higher stroke volume. And higher oxygen consumption of the marathoners is due to their larger a-v $O_2$. The marathoners show both higher threshold and $VO_{2max}$. Especially, measurement of cardiac output during treadmill exercise by improved impedance cardiography is expected to contribute in study of cardiac function of athletes.

  • PDF

Development of 1.0 Tesla Compact MRI System (1.0 Tesla 자기 공명 진단 장치의 개발)

  • Lee, H.K.;Oh, C.H.;Ahn, C.B.;Chang, Y.H.;Shin, D.W.;Lee, K.N.;Jang, K.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.129-134
    • /
    • 1996
  • 1차 년도 G-7 개발 과제로 수행된 자기 공명 진단 장치 (Magnetic Resonance Imaging System)의 개발 내용을 간략히 소개하였다. 성공적인 IT Compact 자기 공명 진단 장치의 완성을 위해 일차적으로 (1)RF (고주파), Gradient(경사 자계), Spectrometer 등의 Hard-ware 관련 MRI 핵심부분, (2) RF, Gradient, Spectrometer, Magnet 등의 각 Sub-system을 연결, 조합, 조정하여 하나의 체계적인 시스템으로 통합하고 운영하는 과정(System Integration), (3)사용자와 시스템을 연결하는 User Interface, Data Base Management, Real time 운영 SW 등과 (4)임상에 적용하여 구체적인 성능과 효용성을 확인하는 기술 등에 대하여 집중 연구하였다. 개발 방법은 (1)지난 16년간 국내에 축적 된 연구 개발 인력들을 최대한 활용하고 (2)연구 개발을 국제화 시켜 필요한 경우 부분별로 개발 인력을 해외에서 보완하고 (3)소수 정예 전문 인력 주의와 요소 기술 또는 중요 부품을 경쟁성 검토 후 필요 시 Out-sourcing 활용으로 최저의 비용으로 개발 기간을 최소화 하는 데 두었다. 개발된 1.0Tesla자기 공명 영상 장치는 미국 물리 학회에서 규격화한 Phantom및 임상 적용을 통하여 서울대 의대 연구 팀과 지속적으로 성능을 평가해 왔다. 개발된 시스템의 해상도는 $256{\times}256$ head 영상에서 1mm 이 하의 해상도를 가짐을 resolution phantom 을 통하여 확인할 수 있었고, $512{\times}512$ 영상에서 는 약 0.5 mm 의 물체를 분리 해냄으로써 외제 시스템들 보다 우수하게 평가 되었다. 차폐 경사코일의 Eddy current영향은2%이내로 촬영 시 영향은 거의 무시할 수 있었다. 또한, 개발된 영상 기법들, 즉 Multislice/Multi Echo, Oblique angle imaging, 64 Echo train을 갖는 고속 촬영 기술들이 자기 공명 장치에 장착되어 임상 적용에 문제가 없도록 하였다. 또한 20mT/m/Amp의 강력한 능동 차폐 경사 자계 코일(Active Shield Gradient Coil)을 기본 사양으로 하고, 수신단을 최대 6개로 확장토록 하여 2차년도의 초고속 촬영 기법(EPI) 및 Phased Array 코일 촬영이 가능토록 하였다. 1차 년도 개발 과제 수행 결과와 향후 개발 과제를 바탕으로 최종 목표인 국제 경쟁력이 있는 자기 공명 진단 장치 즉 기능과 영상의 질은 선진국 제품과 동일하거나 우수하되, 저가격을 구현한 상용화 제품이 완성되어, 첨단 의료기기로서 산업 구조 고도화에 기여하고 수입대체 뿐만 아니 라 수출을 통한 국익 창출과 국가의 기술을 통한 위상 제고에 기여되길 기대한다.

  • PDF

Role of Rab11 on Membrane Trafficking of Rat Vanilloid Receptor, TRPV1 (바닐로이드 수용체 TRPV1의 막수송과정에서의 Rab11의 역할)

  • Um, Ki-Bum;Lee, Soon-Youl
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3096-3102
    • /
    • 2011
  • Vanilloid receptor, TRPV1 (transient receptor potential vanilloid 1) is a non-selective cation channel that responds to a variety of pain-eliciting material including capsaicin, pH, heat. Although, membrane trafficking of TRPV1 was not much known so far, TRPV1 was reported to interact with FIP3 (family of Rab11 interacting protein 3). FIP3 was identified as one of Rab11 interacting proteins that is recently reported important in membrane trafficking of several channel proteins directly or indirectly. Therefore, in this study, we examined the role of Rab11 in the membrane trafficking of TRPV1 using cell biological and biochemical techniques. Rab11 was found really colocalized with TRPV1 based on the result of confocal microscopy. However, GST-pulldown assay, one of biochemical technique, found that Rab11 did not interact with TRPV1. Although Rab11 does not interact with TRPV1 directly, we hypothesized that Rab11 is indeed involved in the membrane trafficking of TRPV1. In order to examine further the role of Rab11 in the membrane trafficking of TRPV1, the expression of TRPV1 on the membrane was examined when the expression of Rab11 was decreased down to about 50% by siRNA technique and found decreased significantly. From this result, we can conclude that Rab11 is involved in the membrane trafficking of TRPV1 in a way of including FIP3.

Health and Environmental Risk Assessment of Pollutants in Pohang (포항지역 오염물질 보건.환경 위해성 평가 -미세먼지의 발생특성 및 농도분포를 중심으로-)

  • Jung, Jong-Hyeon;Choi, Won-Joon;Leem, Heon-Ho;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2719-2726
    • /
    • 2010
  • The purpose of this study was to investigate the scientific basic grounds for the assessment of health and environmental diseases resulting from air pollutants in Pohang. For this study, we investigated pollutants, weather characteristics and concentration distribution of fine particles ($PM_10$) yearly and each season, using data from Air Quality Monitoring Stations. The properties of concentration distribution and seasonal fluctuation of $PM_10$ were studied qualitatively and quantitatively using CALPUFF, air dispersion model. The average concentration of $PM_10$ for each season was spring($75.7{\mu}g/m^3$)>summer($56.8{\mu}g/m^3$)>winter($53.6{\mu}g/m^3$)>fall( $52.7{\mu}g/m^3$). In the case of spring, high concentrations appear due to the Asian dust frequently occurring. The contributions of $PM_10$ classified by the types of pollution source in Pohang were point source 62%>mobile source 33%>area source 5%. An important point is that 97% of emissions were produced from the iron manufacture in steel industry. Therefore, it is necessary to control the emission sources of pollutants and to construct an observation system at Pohang steel industrial complex from now on. It’s time to control the risk factors for health and environmental disease to protect the health of resident in Pohang and its neighboring areas.

Trend of Research and Industry-Related Analysis in Data Quality Using Time Series Network Analysis (시계열 네트워크분석을 통한 데이터품질 연구경향 및 산업연관 분석)

  • Jang, Kyoung-Ae;Lee, Kwang-Suk;Kim, Woo-Je
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.6
    • /
    • pp.295-306
    • /
    • 2016
  • The purpose of this paper is both to analyze research trends and to predict industrial flows using the meta-data from the previous studies on data quality. There have been many attempts to analyze the research trends in various fields till lately. However, analysis of previous studies on data quality has produced poor results because of its vast scope and data. Therefore, in this paper, we used a text mining, social network analysis for time series network analysis to analyze the vast scope and data of data quality collected from a Web of Science index database of papers published in the international data quality-field journals for 10 years. The analysis results are as follows: Decreases in Mathematical & Computational Biology, Chemistry, Health Care Sciences & Services, Biochemistry & Molecular Biology, Biochemistry & Molecular Biology, and Medical Information Science. Increases, on the contrary, in Environmental Sciences, Water Resources, Geology, and Instruments & Instrumentation. In addition, the social network analysis results show that the subjects which have the high centrality are analysis, algorithm, and network, and also, image, model, sensor, and optimization are increasing subjects in the data quality field. Furthermore, the industrial connection analysis result on data quality shows that there is high correlation between technique, industry, health, infrastructure, and customer service. And it predicted that the Environmental Sciences, Biotechnology, and Health Industry will be continuously developed. This paper will be useful for people, not only who are in the data quality industry field, but also the researchers who analyze research patterns and find out the industry connection on data quality.

The Effect of Direct Functional Magnetic Stimulation of the Lesion on Functional Motor Recovery in Spinal Cord Injured Rat (척수손상 흰 쥐의 운동기능 회복에 미치는 손상부위 직접자극을 통한 기능적 자기자극치료 효과)

  • Cho, Yun-Woo;Kim, Su-Jeong;Park, Hea-Woon;Seo, Jeong-Min;Hwang, Se-Jin;Jang, Sung-Ho;Lee, Dong-Gyu;Ahn, Sang-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.53-58
    • /
    • 2011
  • Purpose: The purpose of this study was to determine the effect of direct functional magnetic stimulation (FMS) of affected spinal cord on motor recovery following spinal cord injury in rats. Methods: After a contusion injury at the spinal level T9 using an NYU Impactor, functional magnetic stimulation was delivered by a magnetic stimulator through a round prototype coil (7 cm in diameter). Stimulation parameters were set as follows: repetition rate = 50 Hz (stimulus intensity 100% = 0.18 T), stimulation time = 20 min. Functional magnetic stimulation was administered twice a day, 5 days per week for 8 weeks starting 4 days after spinal cord injury. Functional magnetic stimulationwas delivered directly to the affected spinal cord. Outcomes of locomotor performance were assessed by the Basso Beattie Bresnahan (BBB) locomotor rating scale and by an inclined plane test weekly for 8 weeks. Results: In the BBB test, hindlimb motor function in the Functional magnetic stimulation group improved significantly more compared to the control group at 3, 4, 6, 7, and 8 weeks (p<0.05). In the inclined plane test, the angle of the plane in the functional magnetic stimulation group increased significantly more compared to the control group at 4, 5, 7, and 8 weeks (p<0.05). Conclusion: Our results demonstrate that direct Functional magnetic stimulation of the lesional site may have beneficial effects on motor improvement after spinal cord injury.

First Successful Dynamic Cardiomyoplasty in Korea (심근 성형술 1례 보고)

  • ;;;;;;;;Igor Dubrovski, Ph.D.
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.393-397
    • /
    • 1998
  • A 25-year-old man with viral cardiomyopathy and chronic active hepatitis successfully underwent dynamic cardiomyoplasty for the first time in Korea on July 30, 1996. The patient had been intermittently dyspneic for 5 years and was admitted to our center twice because of heart failure. For the past 2 years, he was NYHA functional class III status with a left ventricular ejection fraction(LVEF) of around 30%. The patient was born with scoliosis and showed a short stature. The liver function showed elevated liver enzymes, and hepatitis B antigen was positive. The liver biopsy revealed chronic active hepatitis. The preoperative echocardiogram showed decreased left ventricular function with grade II mitral and grade II tricuspid regurgitation with dilated left and right atrium. Recently his symptoms worsened and we decided to perform a dynamic cardiomyoplasty. The left latissmus dorsi muscle(LDM) was mobilized and tested with lead placement on his right lateral decubitus position. The patient was positioned into supine and, after median sternotomy, the heart was wrapped with the mobilized muscle. The Russian made cardiomyostimulator(EKS-445) and leads (Myocardial PEMB for heart and PEMP-1 for LDM) were used. The total operation time was 8 hours and there were no perioperative episodes. Postoperatively the LDM had been trained for a 10 week period and currently the stimulation ratio is maintained at 1:4. The postoperative LVEF did not increase with the value of 30-35%. However, the patient feels better postoperatively with slightly increased activity.

  • PDF

Histologic Changes of the Immunologically Untreated Xenogenic Valved Conduit (면역학적 처리 없는 이종 심장 판막 도관의 조직학적 변화에 관한 연구)

  • Sung, Ki-Ick;Seo, Jeong-Wook;Kim, Won-Gon
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.1-7
    • /
    • 2007
  • Backgound: It has been shown that the endothelium of cardiac valves and adjacent great vessels have a reduced immune reaction compared to other vessels. We investigated the clinical feasibility of using immunologically untreated xenogenic valves, in a pig-to-goat pulmonary valve conduit implantation model. Material and Method: Porcine pulmonary valve conduits were prepared without specific immunologic treatment and implanted into the right ventricular outflow tract of goats while undergoing cardiopulmonary bypass. Two goats each were assigned to the following observation time intervals: one day, one week, three months, six months and twelve months. Echo-cardiographic examinations were performed prior to sacrifice of the goat to evaluate pulmonary valve function. After the xenograft specimens were retrieved, histological changes were evaluated microscopically. Result: Ten of the twelve animals survived the predetermined observation time intervals. Aneurysmal dilatations, of the anterior wall of the implanted pulmonary artery, were observed at each of three and twelve month-survival animals. A variable degree of pulmonary valve regurgitation was observed on echocardiography. However, valve stenosis, thrombotic occlusion and vegetation were not seen. Microscopically, the nuclei of the donor tissue disappeared as a result of pyknosis and karyolysis; however the three components of the implanted xenografts (the pulmonary artery, the valve and the infundibulum) were gradually replaced by host cells over time, while maintaining their structural integrity. Conclusion: Immunologically untreated xenogenic pulmonary valve conduits were replaced by host cells with few observed clinical problems in a pig to goat pulmonary valve implantation model. Therefore, they might be an alternative bioprosthesis option.