Usability Evaluation of Foot Pedal Switch in X-ray Radiography System (진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가)

  • Kwon, Hyeokjin;Jung, Hongmoon;Jung, Jaeeun;Jung, Kyunghwan;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • A foot pedal switch in the diagnosis x-ray radiography system has been researched to improve radiologic technologist works and patient satisfaction. The switch has been installed in the diagnosis x-ray radiography system used in domestic clinics. Quantitative evaluation has been conducted by measuring the exposure dose reproducibility test, tube voltage, mAs, and percentage average error. Qualitative evaluation has been conducted by analysis of the radiologic technologists questionnaire. In the quantitative evaluation for the use of the foot pedal switch, the coefficient of variation was less than 0.05 in the exposure dose reproducibility test. In the mAs test, percentage average error of ${\pm}20%$ was measured. There was no problem raised since it meets the all inspection standards of the diagnosis x-ray generator. In the qualitative evaluation, most of the opinions are that it has a clinical value for the foot pedal switch in the diagnosis x-ray radiography system. Therefore, developing the foot pedal switch for the diagnosis x-ray radiography system can improve effectively the rapidity and accuracy of the radiologic technologist work. In addition, it is effective in decreasing the x-ray exposure of patients and increasing satisfaction for the medical service due to reduction of retaking x-ray.

A New Histone Deacetylase Inhibitor, MHY4381, Induces Apoptosis via Generation of Reactive Oxygen Species in Human Prostate Cancer Cells

  • Richa, Sachan;Dey, Prasanta;Park, Chaeun;Yang, Jungho;Son, Ji Yeon;Park, Jae Hyeon;Lee, Su Hyun;Ahn, Mee-Young;Kim, In Su;Moon, Hyung Ryong;Kim, Hyung Sik
    • Biomolecules & Therapeutics
    • /
    • v.28 no.2
    • /
    • pp.184-194
    • /
    • 2020
  • Histone deacetylase (HDAC) inhibitors represent a novel class of anticancer agents, which can be used to inhibit cell proliferation and induce apoptosis in several types of cancer cells. In this study, we investigated the anticancer activity of MHY4381, a newly synthesized HDAC inhibitor, against human prostate cancer cell lines and compared its efficacy with that of suberoylanilide hydroxamic acid (SAHA), a well-known HDAC inhibitor. We assessed cell viability, apoptosis, cell cycle regulation, and other biological effects in the prostate cancer cells. We also evaluated a possible mechanism of MHY4381 on the apoptotic cell death pathway. The IC50 value of MHY4381 was lower in DU145 cells (IC50=0.31 µM) than in LNCaP (IC50=0.85 µM) and PC-3 cells (IC50=5.23 µM). In addition, the IC50 values of MHY4381 measured in this assay were significantly lower than those of SAHA against prostate cancer cell lines. MHY4381 increased the levels of acetylated histones H3 and H4 and reduced the expression of HDAC proteins in the prostate cancer cell lines. MHY4381 increased G2/M phase arrest in DU145 cells, and G1 arrest in LNCaP cells. It also activated reactive oxygen species (ROS) generation, which induced apoptosis in the DU145 and LNCaP cells by increasing the ratio of Bax/Bcl-2 and releasing cytochrome c into the cytoplasm. Our results indicated that MHY4381 preferentially results in antitumor effects in DU145 and LNCaP cells via mitochondria-mediated apoptosis and ROS-facilitated cell death pathway, and therefore can be used as a promising prostate cancer therapeutic.

STAT3 is Activated in a Subset of Benign and Malignant Chondroid Tumors (양성 및 악성 연골 종양에서의 STAT3 활성화)

  • Park, Hye-Rim;Park, Yong-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.15 no.2
    • /
    • pp.130-137
    • /
    • 2009
  • Purpose: STAT3 is an oncogene that regulates critical cellular processes, and its constitutive activation has been demonstrated to correlate with biological and clinical features in many types of human malignancy. Materials and Methods: In this study, STAT3 activation was assessed in variable benign and malignant chondroid tumors in bone by immunohistochemistry using a monoclonal antibody specific for $tyrosine^{705}$-phosphorylated STAT3 ($pSTAT3^{tyr705}$). Results: Among conventional chondrosarcomas (n=17), three cases(50%) of grade III chondrosarcomas were pSTAT3-positive. All grade I and II chondrosarcomas were pSTAT3-negative. This pSTAT3 positivity according to the histologic grade was statistically significant (p=0.0432). Two cases(50%) of clear cell chondrosarcomas were pSTAT3-positive. Six cases (50%) among 12 benign chondroid tumors(6 enchondromas, 3 chondroblastomas, and 3 chondromyxoid fibromas) were also $pSTAT3^{tyr705}$-positive. Conclusion: In conclusion, STAT3 activation is associated with higher tumor grade in conventional chondrosarcomas. Our results suggest that STAT3 is activated in a subset of benign and malignant chondroid tumors, and may support the extension of the cancer stem cell hypothesis to include tumors of cartilaginous lineage.

  • PDF

Implementation of a portable pulse oximeter for SpO2 using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대용 산소포화도 측정 시스템 구현)

  • Lee, Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.678-681
    • /
    • 2003
  • In this paper, we aims to develop a microcontroll er-based portable pulse oximeter using Compact Flash Interface. First, portable pulse oxineter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of SpO$_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patients condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO$_2$ modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact flash interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

The Evaluation of Patients' Radiation Dose During TACE of Interventional Radiology (TACE의 중재적 시술시 환자의 피폭선량 평가)

  • Lee, Seung-Youl;Lim, Hyun-Soo;Han, Man-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.209-214
    • /
    • 2011
  • Goal of this study was to measure effective radiation dose of highly exposed patients who were treated by TACE, interventional radiology from June to September 2010. The effective radiation dose was approximately measured by weighted DAP (dose area product) with the ionization chamber which is inserted in angiography equiment (Philips Allura Xper FD 20). Radiation dose was measured by TLD which was attached to patients' thyroid and genital gland. The average of ED (effective dose) was 18.43${\pm}$6.63 mSv per person and the average of radiation dose of thyroid and genital gland was 0.37 mSv, 0.77 mSv, respectively. The mean radiation dose of operators who wear the protector was 0.07 mSv for thyroid, and 0.01 mSv for genital gland, respectively. All staffs involved in TACE treatment, have to keep them aware and use the appropriate protectors to reduce the radiation dose of patient.

The Study About Attenuation of Scatter Ray According to Distance Inverse Square Law at General Projection (일반촬영 시 거리역자승법칙에 따른 산란선 감약에 관한 연구)

  • Jeon, Min-Cheol;Lim, Hyun-Soo;Han, Man-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.183-188
    • /
    • 2011
  • We studied the optimal location where the radiation dose of radiological technologists is minimally measured. The measured scatter dose has been compared with the distance inverse square law. We measured the primary X-ray with different tube conditions (60, 70, 81 and 90 kVp) and distances (60, 120 and 180 cm). The scatter ray has been measured with various locations (42.5, 52.4 and 62.4 cm for front and back side, 0 to 60 cm with 10 cm interval for left and right side). The results of this study showed that the dose of primary X-ray was attenuated to 20.52 (27.20%), 28.58 (25.20%), 38.82 (26.32%) and 48.20 mR (26.27%) for each tube voltages at 120 cm. In addition, The dose were 7.06 (8.91%), 9.90 (8.73%), 13.64 (9.25%) and 16.60 mR (9.05%) at 180 cm. As for the scatter in front and back side, the attenuated dose were 0.15 mR (23.09%) and 0.15 mR (22.08%) at 120 cm, and 0.07 mR (10.43%) and 0.06 mR (8.83%) at 180 cm. Scatter was decreased in third quadrant. Therefore, it is recommended that radiological technologists should keep long distance from the object.

Synthesis and characterization of sulfonated poly(arylene biphenylsulfone ether) copolymers containing hydroquinone moiety for polymer electrolyte membrane (고분자 전해질 멤브레인용 하이드로퀴논 부분이 포함된 설폰화된 폴리(아릴렌 비페닐설폰 에테르) 공중합체의 합성과 특성평가)

  • Yoo, Dong-Jin
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.121-127
    • /
    • 2010
  • In present work, sulfonated poly(arylene biphenyklsulfone ether) copolymers containing hydroquinone moiety were successfully synthesized using 4,4'-bis[(4-chlorophenyl)sulfonyl]-1,1'-biphenyl(BCPSBP), hydroquinone sulfonic acid potassium salt(sHQ), 4,4'-sulfonyldiphenol and evaluated their characteristics. Three kinds of polymer electrolyte membranes, PBPSEH-HQ00, PBPSEH-HQ10 and PBPSEH-HQ30 were prepared by using mole fraction of sulfonated hydroquinone(sHQ). The structure of the fabricated polymers was analyzed using NMR, IR and GPC. The Mw(weight-average molecular weights) of the polymers were in the range of 62,000-213,000 g $mol^{-1}$, and the molecular weight distribution (Mw/Mn) varied from 1.66-4.04. The thermal analysis of the copolymers was carried out by TGA and DSC. The temperature of Td5% and Td10% was decreased with the mole fraction of sHQ but Tg was increased with the mole fraction. The water uptake, IEC and ion conductivity were increased with increasing the ionic cluster of the polymers. The proton conductivity equal to 9.4 mS $cm^{-1}$ was measured for the PBPSEH-HQ30 membrane at $90^{\circ}C$ and 100% relative humidity. From the observed results it is clear that the prepared hydrocarbon membrane can be considered as suitable polymer electrolyte membrane for the application of PEMFC.

A Study of the Basic Design for Smart Clothing based on Measurement of the Respiration (호흡 측정 기능의 스마트 의류를 위한 기초 디자인 연구)

  • Cho, Ha Kyung;Min, Se Dong
    • Science of Emotion and Sensibility
    • /
    • v.15 no.4
    • /
    • pp.415-424
    • /
    • 2012
  • According to introduction of Well-Being lifestyle and ageing society, vital sign monitoring system which can be continued measurement of vital sign has been increased their important in field of the healthcare. Under this trend, Respiration monitoring system has been studied and developed in a various way to apply continued monitoring and non-conscious monitoring system. But, Study of the respiration monitoring system based on consumer needs and usability test is insufficient. In this study, Textile capacitive pressure sensor(TCPS) of belt type was developed and tested it's utility and subjective sensibility. TCPS measures respiration signals and can be derived in real time monitoring. As a result, monitoring respiration using textile capacitive pressure sensor offers a promising possibility of convenient measurement of respiration rate (correlation (r=0.9553, p<0.0001). In the result of usability and wearability test, all of categorizes(perceived change, wearability, movement, facility of management, usefulness) were received favorable evaluation on usability test( mean value : 3.8), and suitable location of TCPS in the clothing is deriven on the abdomen part. According to synthetical results, Basic smart clothing design based on respiration monitoring system is proposed.

  • PDF

A pilot study on measuring the human cortisol using an electronic device (전자소자를 이용한 인간 감성지표 코티졸 검출에 관한 기초연구)

  • Lee, Hee-Jo;Lee, Jung-Hyun;Hwang, Yoo-Sun;Jung, Hyo-Il
    • Science of Emotion and Sensibility
    • /
    • v.14 no.4
    • /
    • pp.531-536
    • /
    • 2011
  • The precise measurement of human emotion is of pivotal importance in the field of emotion science. Based on the perspective of psychoneuroimmunoendocrinology, human emotion is now considered to be measurable by body fluid. The biological molecule cortisol, which is known for the stress hormone, has been widely investigated to help researchers to estimate the stress loaded on human body. Until now, several measurement techniques such as High Performance Liquid Chromatography (HPLC), fluorometric assay, and reverse phase chromatography have been developed. However, since these measurements are expensive, take relatively long time for an operation, and they are not portable, they are not appropriate for POCT (point of care testing). In this paper we demonstrate the performance of a miniaturized-microwave resonant device in the measurement of cortisol. Our method has many advantages in that it requires a small volume of sample, has fast response time, is easy to operate and needs no labeling process. Besides, it will shed a light on the measurement techniques for emotion science.

  • PDF

Design and fabrication of paper microfluidic channel (종이기반 미세유체 채널의 설계 및 제작기술)

  • Lee, Jung-Hyun;Hwang, Yoo-Sun;Jung, Hyo-Il
    • Science of Emotion and Sensibility
    • /
    • v.14 no.4
    • /
    • pp.525-530
    • /
    • 2011
  • Emotion is composed of various feelings such as pleasure, sorrow, comfortability, and so on. The complicated process of the measurement has long been recognized as a major hindrance for the studies of emotion. Previously, individuals' emotion has mainly been measured by means of self-report, interview, EEG (electroencephalogram), ECG (electrocardiogram), EOG (electroculography), and body temperature. With thanks to nano/micro technologies, the possibility in the development of emotion-on-a-chip (EOC) has begun to be proposed. EOC will make it possible to analyze one's psychological status by taking a drop of blood. Discovery of emotional biomarkers in body fluids, understanding of the correlation between those biomarkers and the results from brain science are prerequisites to validate the EOC technology. In this paper, paper microfluidics are introduced as a good candidate for the EOC. As paper microfluidics is cost-effective and easy to use it is expected to be a useful device for the emotion measurement. We present the design and fabrication process for the simple paper-based microfluidic device and discuss the possible application in the field of measuring the human emotion.

  • PDF