• Title/Summary/Keyword: Medical Display Device

Search Result 53, Processing Time 0.023 seconds

Development of Oriental-Western Fusion Patient Monitor by Using the Clip-type Pulsimeter Equipped with a Hall Sensor, the Electrocardiograph, and the Photoplethysmograph (홀센서 집게형 맥진기와 심전도-용적맥파계를 이용한 한양방 융합용 환자감시장치 개발연구)

  • Lee, Dae-Hui;Hong, Yu-Sik;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.4
    • /
    • pp.135-143
    • /
    • 2013
  • The clip-type pulsimeter equipped with a Hall sensor has a permanent magnet attached in the "Chwan" position to the center of a radial artery. The clip-type pulsimeter is composed of a hardware system measuring voltage signals. These electrical bio-signals display pulse rate, non-invasive blood pressure, respiratory rate, pulse wave velocity (PWV), and spatial pulse wave velocity (SPWV) simultaneously measured by using the radial artery pulsimeter, the electrocardiograph (ECG), and the photoplethysmograph (PPG). The findings of this research may be useful for developing a oriental-western biomedical signal storage device, that is, the new and fusion patient monitor, for a U-health-care system.

Design of the Blood Pressure Measurement System Using the Inflatable Oscillometric Method (가압식 오실로메트릭 방법을 사용한 혈압측정 시스템의 설계)

  • 노동곤;이윤선;지정호;박성빈;이계형;김해관
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.281-286
    • /
    • 2003
  • Blood Pressure is one of the most fundamental Parameters which reflects physical conditions medically and the blood pressure measurement system using oscillometric method is a Non-Invasive Blood Pressure measurement device by measuring arterial Pressure through a cuff. In this paper. we designed a inflatable wrist blood pressure system which measures blood Pressure during the stepping inflation in the wrist cuff. The hardware system consists of a main power unit, a bladder in cuff unit, signal detection units, signal Processing units. a wireless data transmission unit, and a data display unit. We evaluated the reliability of this system by comparing and analyzing systolic. diastolic blood Pressure, and heart rate with other commercial blood Pressure measurement devices. Characteristic ratio values used to determine systolic and diastolic blood Pressure using MAA(Maximum Amplitude Algorithm) were 0.436 and 0.671 respectively.

Design a Portable Biomedical Signal Measuring System for U-Health (U-Health를 위한 휴대형 생체신호 측정 시스템 설계)

  • Lee, Han-Wook;Kim, Sung-Hoo;Jeong, Won-Geun;Lee, Ju-Won;Jang, Doo-Bong;Lee, Gun-Ki
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.2
    • /
    • pp.51-56
    • /
    • 2008
  • U-Health is abbreviated from ubiquitous Health. Its final aim is "to improve the quality of life. To realize it, it is needed to generalize IT infrastructure such as the development of information-technology and construction of network. It is guaranteed to get medical care benefits unconsciously every time and everywhere based on this system. In this study, the environment of unconscious measurement was set up through ultra-violet instead of the existing Probe to wear with finger to follow this. TFT-LCD was included into module for display. U-Healthcare focused on the minimization and portable characteristic through the designed Zigbee communication module. Handled healthcare device was developed based on the U-Healthcare.

  • PDF

A Low-noise Multichannel Magnetocardiogram System for the Diagnosis of Heart Electric Activity

  • Lee, Yong-Ho;Kim, Ki-Woong;Kim, Jin-Mok;Kwon, Hyuk-Chan;Yu, Kwon-Kyu;Kim, In-Seon;Park, Yong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.154-163
    • /
    • 2006
  • A 64-channel magnetocardiogram (MCG) system using low-noise superconducting quantum interference device (SQUID) planar gradiometers was developed for the measurements of cardiac magnetic fields generated by the heart electric activity. Owing to high flux-to-voltage transfers of double relaxation oscillation SQUID (DROS) sensors, the flux-locked loop electronics for SQUID operation could be made simpler than that of conventional DC SQUIDs, and the SQUID control was done automatically through a fiber-optic cable. The pickup coils are first-order planar gradiometers with a baseline of 4 em. The insert has 64 planar gradiometers as the sensing channels and were arranged to measure MCG field components tangential to the chest surface. When the 64-channel insert was in operation everyday, the average boil-off rate of the dewar was 3.6 Lid. The noise spectrum of the SQUID planar gradiometer system was about 5 fT$_{rms}$/$\checkmark$Hz at 100 Hz, operated inside a moderately shielded room. The MCG measurements were done at a sampling rate of 500 Hz or 1 kHz, and realtime display of MCG traces and heart rate were displayed. After the acquisition, magnetic field mapping and current mapping could be done. From the magnetic and current information, parameters for the diagnosis of myocardial ischemia were evaluated to be compared with other diagnostic methods.

A Development of an Acupoints Education Table using 3D Technology and Augmented Reality (경혈 교육을 위한 3D 및 증강현실 기술을 활용한 한의학 통합교육 테이블 개발)

  • Yang, SeungJeong;Ryu, ChangJu;Kim, SangCheol;Kim, JaeSouk
    • Korean Journal of Acupuncture
    • /
    • v.38 no.4
    • /
    • pp.267-274
    • /
    • 2021
  • Objectives : Acupoints education is important in that it can determine the clinical competency of Korean Medicine Doctors (KMDs). Accordingly, we aimed to develop a practical simulator for acupoints education, acupoints training, acupoints practice, and acupoints evaluation. Methods : Korean Medicine (KM) SMART Table can be divided into hardware, server and components, and is organically linked. We develop KM SMART Table that combines the hardware of a human-sized table with a UHD display capable of multi-touch in two cases and software that can teach acupoints. We make Augmented Reality (AR) contents linked with KM SMART Table contents and develop applications that can use contents using mobile devices. By developing an AR image tracking module to react with KM SMART Table, it enables acupoint learning according to the mobile device platform and human anatomy. Results : The current system is a prototype where some 3D technology has been implemented, but the AR function will be produced later. New learning using 3D and AR will be required during acupoints education and acupoints practice. It will be used a lot in OSCE (Objective Structured Clinical Examination) practices for strengthening the competency of KMDs, and it will be of great help not only in KM education as a unique simulator of KM, but also in the practice of acupuncture and chuna for musculoskeletal diseases. Conclusions : The KM SMART Table is a technology that combines 3D and AR to learn acupoints, and to conduct acupoints OSCE practice, and we suggest that it can be usefully used for educational evaluation.

u-EMS : An Emergency Medical Service based on Ubiquitous Sensor Network using Bio-Sensors (u-EMS : 바이오 센서 네트워크 기반의 응급 구조 시스템)

  • Kim, Hong-Kyu;Moon, Seung-Jin
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.13 no.7
    • /
    • pp.433-441
    • /
    • 2007
  • The bio-Sensors, which are sensing the vital signs of human bodies, are largely used by the medical equipment. Recently, the sensor network technology, which composes of the sensor interface for small-seize hardware, processor, the wireless communication module and battery in small sized hardware, has been extended to the area of bio-senor network systems due to the advances of the MEMS technology. In this paper we have suggested a design and implementation of a health care information system(called u-EMS) using a bio-sensor network technology that is a combination of the bio-sensor and the sensor network technology. In proposed system, we have used the following vital body sensors such as EKG sensor, the blood pressure sensor, the heart rate sensor, the pulse oximeter sensor and the glucose sensor. We have collected various vital sign data through the sensor network module and processed the data to implement a health care measurement system. Such measured data can be displayed by the wireless terminal(PDA, Cell phone) and the digital-frame display device. Finally, we have conducted a series of tests which considered both patient's vital sign and context-awared information in order to improve the effectiveness of the u-EMS.

Image Enhancement and Clinical Evaluation in Digital Chest Radiography (디지털 방사선 흉부영상의 영상개선과 임상평가)

  • Kim, Sung-Hyun;Suh, Tae-Suk;Choe, Bo-Young;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.143-149
    • /
    • 2008
  • The aim of this study is to suggest the method for image enhancement of digital chest radiograph and evaluate clinically the quality of the resultant image. A nonlinear iterative filter was developed in order to reduce quantum noise preserving edge. Dynamic range was adjusted and adaptive image enhancement was performed based on the property of anatomic region and the degree of compatibility with neighboring pixels. The lung fields were enhanced appropriately to visualize effectively vascular tissue, bronchus and lung tissue with the desired mediastinum enhancement. Clinic evaluation was performed by three radiologists with at least 8 years experience. The anatomic regions of 11 in PA and 9 in Lateral were observed carefully in each 100 radiographs according to ITU (International Telecommunication Union) recommendation 500 protocol. The result showed the mean 3.4 between good and adequate. This means that the clinical utility of the image quality is enough. In this study, image enhancement was carried out considering image display device and human perceptual system to prevent the loss of useful anatomic information. In order to increase the diagnostic accuracy in digital radiograph, the continuous study on image enhancement is needed.

  • PDF

Optical System Design for Real-Time 3-Dimension Ophthalmoscope (실시간 3차원 검안경의 광학설계)

  • Lee, Soak-Hee;Yang, Yun-Sik;Choe, Oh-Mok;Sim, Sang-Hyun;Doo, Ha-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.35-39
    • /
    • 2003
  • The display technology on the retina is the key role in inspecting the condition of the patients. 2-dimensional retina image is widely used in the eye examination as of today. Recently, 3-dimensional retina image ones have been introduced to this area, but the quality of the image is not fully satisfied to the operator. For the purpose of developing 3-D retina imaging instrument, the optimization of a 3-D retina imaging system using Code-V tool was investigated in this thesis. He-Ne laser having the wavelength 632.8 nm was used to make a power source to detect the retina. Several lenses and mirrors installed on sledge which were developed to perform focus control on 3-D device were designed to make a beam focusing and direct line. Polygon scanner having 24 mirror facets and galvanometer making tilting movement were utilized to make a 2-D laser plane. Also, design of eye ball had been fulfilled to see the focus of the 2-D plane. Reflected ray from retina detected on the sensor array with the same path. All cognitive components were optimized for aberration correction in order to focus on retina. Results of optimization were compared to those of initial designed optics system. On the basis of above results, the result of third aberration has been corrected to stable values to the optical system. MTF evaluating the resolution of an image has been closely correlated to the diffraction limit and PSF indicating the strength distribution of an image has shown the SR value as 0.9998 having high performance. The possibility of new and powerful 3-D retina image instrument was verified by simulating each component of the instrument by Code-V.

  • PDF

Improvement of Endoscopic Image using De-Interlacing Technique (De-Interlace 기법을 이용한 내시경 영상의 화질 개선)

  • 신동익;조민수;허수진
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.469-476
    • /
    • 1998
  • In the case of acquisition and displaying medical Images such as ultrasonography and endoscopy on VGA monitor of PC system, image degradation of tear-drop appears through scan conversion. In this study, we compare several methods which can solve this degradation and implement the hardware system that resolves this problem in real-time with PC. It is possible to represent high quality image display and real-time processing and acquisition with specific de-interlacing device and PCI bridge on our hardware system. Image quality is improved remarkably on our hardware system. It is implemented as PC-based system, so acquiring, saving images and describing text comment on those images and PACS networking can be easily implemented.metabolism. All images were spatially normalized to MNI standard PET template and smoothed with 16mm FWHM Gaussian kernel using SPM96. Mean count in cerebral region was normalized. The VOls for 34 cerebral regions were previously defined on the standard template and 17 different counts of mirrored regions to hemispheric midline were extracted from spatially normalized images. A three-layer feed-forward error back-propagation neural network classifier with 7 input nodes and 3 output nodes was used. The network was trained to interpret metabolic patterns and produce identical diagnoses with those of expert viewers. The performance of the neural network was optimized by testing with 5~40 nodes in hidden layer. Randomly selected 40 images from each group were used to train the network and the remainders were used to test the learned network. The optimized neural network gave a maximum agreement rate of 80.3% with expert viewers. It used 20 hidden nodes and was trained for 1508 epochs. Also, neural network gave agreement rates of 75~80% with 10 or 30 nodes in hidden layer. We conclude that artificial neural network performed as well as human experts and could be potentially useful as clinical decision support tool for the localization of epileptogenic zones.

  • PDF

Quality Assurance of Volumetric Modulated Arc Therapy for Elekta Synergy (Elekta Synergy 선형가속기를 이용한 입체적세기조절회전방사선치료(VMAT) 정도관리)

  • Shim, Su-Jung;Shim, Jang-Bo;Lee, Sang-Hoon;Min, Chul-Kee;Cho, Kwang-Hwan;Shin, Dong-Oh;Choi, Jin-Ho;Park, Sung-Ill;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.33-41
    • /
    • 2012
  • For applying the quality assurance (QA) of volumetric modulated arc therapy (VMAT) introduced in Eulji Hospital, we classify it into three different QA steps, treatment planning QA, pretreatment delivering QA, and treatment verifying QA. These steps are based on the existing intensity modulated radiation therapy (IMRT) QA that is currently used in our hospital. In each QA step, the evaluated items that are from QA program are configured and documented. In this study, QA program is not only applied to actual patient treatment, but also evaluated to establish a reference of clinical acceptance in pretreatment delivering QA. As a result, the confidence limits (CLs) in the measurements for the high-dose and low-dose regions are similar to the conventional IMRT level, and the clinical acceptance references in our hospital are determined to be 3 to 5% for the high-dose and the low-dose regions, respectively. Due to the characteristics of VMAT, evaluation of the intensity map was carried out using an ArcCheck device that was able to measure the intensity map in all directions, $360^{\circ}$. With a couple of dosimetric devices, the gamma index was evaluated and analyzed. The results were similar to the result of individual intensity maps in IMRT. Mapcheck, which is a 2-dimensional (2D) array device, was used to display the isodose distributions and gave very excellent local CL results. Thus, in our hospital, the acceptance references used in practical clinical application for the intensity maps of $360^{\circ}$ directions and the coronal isodose distributions were determined to be 93% and 95%, respectively. To reduce arbitrary uncertainties and system errors, we had to evaluate the local CLs by using a phantom and to cooperate with multiple organizations to participate in this evaluation. In addition, we had to evaluate the local CLs by dividing them into different sections about the patient treatment points in practical clinics.