• Title/Summary/Keyword: Medical Display Device

Search Result 53, Processing Time 0.026 seconds

Dynamic Braille Display Using Dielectric Elastomer (고분자유전체를 이용한 동적 점자출력기)

  • 최혁렬;이상원;정광목;이성일;최후곤;전재욱;남재도
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.8
    • /
    • pp.592-599
    • /
    • 2003
  • As one of the Principal modalities of human sensation, tactile feel is prerequisite for building wide variety of applications such as telemanipulation, virtual reality and medical engineering. A dynamic Braille display device based on a polymer actuator is presented. The actuator, often called artificial muscle actuator has advantageous features over the existing methods in terms of intrinsic softness, ease of fabrication, cost-effectiveness and miniaturization. The principles of actuation with dielectric elastomer is introduced, and necessary considerations on the design of a tactile display device are discussed. The design of the device is described in detail including the fabrication process and driving electronics. Also, preliminary results of experiments are given to evaluate its performance.

Quantitative Analysis of Effects for Quality Control on Medical Primary Class LCD Display Devices Based on AAPM TG18 Report (AAPM TG18에 의한 진단용 LCD 디스플레이 장치 정도관리 효과의 정량적 분석)

  • Jung Hai-Jo;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.77-82
    • /
    • 2006
  • The image display is an Important component of PACS and of medical digital imaging chain. Displayed image qualify is affected by the physical characteristics of display device, appropriate clinical settings and calibrations, and ambient lighting conditions. The performance of display systems is continuously degraded over time due to luminance deterioration and changes of clinical setting parameters. A routine QC is recommended because the performance of display systems is continuously degraded over time. Ten flat panel monochrome LCD display devices were included in the evaluation of the QC effect. The effect of QC on primary class LCD medical display devices for selected QC tests was evaluated by comparing the performances, luminance response, luminance dependencies, display resolution and display chromaticity in this study, of before and after the calibration procedures. The effects of the QC are significant to luminance response and luminance spatial dependencies test and the other side, are slight to the display resolution and display chromaticity test. A routine QC of display device is essential for the consistency of medical image display and presentation. The study of the QC effects of display devices will play an important role in practical QC procedures of display devices.

  • PDF

Portable Electrocardiograph and Smart Device-based Heart Health Monitoring and Risk Notification System (휴대용 심전도 측정기와 스마트 기기 기반의 심건강 모니터링 및 위험도 알림 시스템)

  • Cho, Jinsoo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.2
    • /
    • pp.73-78
    • /
    • 2013
  • This paper proposes a portable electrocardiograph and smart device-based heart health monitoring and risk notification system. The proposed system consists of a portable electrocardiograph and a smart device for a system user, and a web-based monitoring system for observers. This system can improve the convenience and efficiency of measurement by using a light-weight portable electrocardiograph and a smart device. In addition, any authorized person such as caregiver or family member who is not related to medical institution can monitor users'heart health in real-time using the web-based monitoring system. Therefore, a user and authorized remote observers can efficiently monitor and manage user's heart health in daily-life even without any medical institution's help, and can preemptively deal with any possible dangerous situations, such as degeneration of a cardiac disorder and sudden cardiac death.

The Telemedicine System based ECG Data using Bio-Signal Meter and Smart Device (생체신호 측정기와 스마트 디바이스를 활용한 심전도 데이터 기반의 원격진료 시스템)

  • Kim, Yi-Seul;Cho, Jinsoo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.3
    • /
    • pp.51-56
    • /
    • 2012
  • In this paper, we propose a telemedicine system based ECG data using a bio-signal meter and a smart device for treating faraway patients. This system is composed of a patch-shaped portable bio-signal meter, patient's smart device application, and doctor's PC software. Using these components, doctors and patients can do telemedicine. First, a patient measures his own ECG signal with a bio-signal meter and send the data to a doctor using a smart device application. Then, the doctor checks the ECG data, and make and send a diagnosis chart to web server. Likewise, doctors and patients can be offered a medical environment without time and space restraints. Applying this system to real medical system can improve the problem of low accessibility and efficiency and also can reduce medical expenses.

Haptic Display of A Puncture Task with 4-legged 6 DOF Parallel Haptic Device (6자유도 병렬형 햅틱장치를 이용한 구멍뚫기 작업의 햅틱 디스플레이)

  • 김형욱;서일홍
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.6
    • /
    • pp.1-10
    • /
    • 2004
  • A haptic rendering system is proposed for a puncture task of a virtual vertebra model. To build a mesh model from medical images, Delaunay triangulation is applied and physical models are based on elasticity theory. Also, a redundant actuated 6 DOF parallel type haptic device is designed to display large force and to resolve the singularity problem of parallel type mechanisms. Haptic feeling of puncture task and the performance of the proposed haptic device are tested by two puncture task experiments.

A Sutdy on Organic Emission Device of Chitosan Used (키토산을 이용한 유기 발광 소자에 관한 연구)

  • Jung, Ki-Taek;Kang, Soo-Jung;Kim, Nam-Ki;Roh, Seung-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1062-1065
    • /
    • 2004
  • The importance of display is becoming increasingly important due to the development of information and industry where it leads to diverse and abundant information in today's society. The demand and application range for FPD(Flat Panel Display), specifically represented by LCD(Liquid Crystal Display) and PDP(Plasma Display Panel), have been rapidly growing for its outstanding performance and convenience amongst many other forms of display. The current focus has been on OLED(Organic Light Emitting Diode) in the mobile form, which has just entered into mass production amid the different types of FPD. Many studies are being conducted in regards to device, vacuum evaporation, encapsulation, and drive circuits with the development of device as a matter of the utmost concern. This study develops a new type of light-emitting materials by synthesizing medical polymer organic chitosan and phosphor material CuS. Chitosan itself satisfies the Pool-Frenkel Effect, an I-V specific curve, with a thin film under $20{mu}m$, and demonstrates production possibility for a living body sensors solely with the thin film. Furthermore, it enables production possibility for EML of organic EL device(Emitting Layer) with liquid Green light emitting and Blue light emitting as a result of synthesis with phosphor material.

  • PDF

Design of Continuous Passive Motion Medical Device System with Range of Motion Measurement Function (관절가동범위 측정 기능을 갖는 연속수동운동 의료기기 시스템 설계)

  • Kang Won Lee;Min Soo Park;Do Woo Yu;Oh Yang;Chang Ho Lee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.87-92
    • /
    • 2023
  • As the elderly population increases, the number of patients with various joint diseases, including degenerative arthritis, is steadily increasing. CPM medical devices are needed to effectively treat degenerative arthritis that is common in the elderly population. Domestic CPM medical devices have limited functions and are highly dependent on imports for expensive imported medical devices. To solve this problem, we designed a ROM measurement function using a current sensor that is not present in existing composite joint CPM medical devices. The algorithm was designed using the fact that the force caused by joint stiffness greatly increases the current flowing through the DC motor. In addition, the need for digital healthcare in the medical field is gradually expanding as the proportion of chronically ill patients increases due to the spread of the non-face-to-face economy due to COVID-19 and the aging population. Therefore, this paper aims to improve the performance of CPM medical devices by allowing real-time confirmation of rehabilitation exercise information and operation range measurement results in accordance with digital healthcare trends through a Bluetooth application developed as an Android studio.

  • PDF

Application of spectral image - Present and Promise -

  • Miyake, Yoichi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1158-1159
    • /
    • 2009
  • Tri-stimulus values of CIE-XYZ and RGB values obtained by photographic film, CCD camera or scanner depend on the spectral sensitivity of imaging devices and the spectral radiant distribution of the illumination. It is important to record and reproduce the reflectance spectra of the object for true device independent color reproduction and high accurate recording of the scene. In this paper, a method to record the reflection spectra of the object is introduced and its application to spectral endoscopes is presented.

  • PDF