• Title/Summary/Keyword: Medical Device Management

Search Result 306, Processing Time 0.033 seconds

Medical Staff's Awareness of Infected Patient Transfer Robots: Using SERVQUAL and AHP (감염환자 이송 로봇에 대한 의료종사자의 인식: SERVQUAL과 AHP를 활용하여)

  • Choi, Hyunchul;Seo, Seul-Ki;Kwon, Jae-Yong;Park, Sangchan;Chang, Hyejung
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.3
    • /
    • pp.381-401
    • /
    • 2023
  • Purpose: The purpose of this study was to understand the perception of medical staff to propose an infected patient transport robot as a means of responding to infectious diseases. Methods: The data collected through the survey was analyzed through AHP analysis. The measurement tools used in this study were derived through the SERVQUAL model and Focus Group Interview(FGI), and consisted of four detailed questions for each of five classes: tangible, reliability, responsiveness, assurance, and empathy. Results: As a result of the study, there are concerns about risk factors that may occur in areas where medical staff intervention is minimized. Above all, we confirmed the consensus that safety should be the top priority during the process of robots to transport patients. In particular, highlighted were the resolution of device errors that may occur during the process for transporting patients and easy provision of the first aid. Additionally, the ability to monitor patients and suppress infection factors turned out to be important, which was directly related to the simplification of the role of medical staff and work efficiency. Conclusion: As one of the means of effectively controlling infectious diseases in a pandemic situation, a robot to transport the infected patient was considered. However, in order to commercialize this, specific verification of the safety of medical staff and patients is needed, and empirical data on providing the first aid, patient monitoring, and infection factor suppression should be presented.

Analysis on Failure Statistics of Cyclotron Component (사이클로트론 구성부품별 고장통계분석)

  • Cho, June-Ho;Jung, Jae-Eun;Jung, Hong-Moon;Won, Do-Yeon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.61-67
    • /
    • 2014
  • The demand of cyclotron for PET (positron emission tomography) has rapidly grown as the more use of PET or PET-CT equipment requires the increased amount of radioactive isotopes for clinical positron emission. While research on failure statistics of medical equipment used in medical centers has continued to be done, the analysis and study on failure statistics of cyclotron have rarely been conducted. However, the growing demand shows the urgency of systematical management guideline and countermeasures for device failure to minimize any supply delay of radiopharmaceuticals occurred by such failure and complains from waiting patients for PET-CT diagnosis. Therefore, this study aims to analyze the failure report from Minitrace equipped in cyclotron which is owned by the department of nuclear medicine at Yeungnam University Medical Center and draws on the data to build effective management system for cyclotron.

  • PDF

Smart Device based ECG Sensing IoT Applications (스마트 디바이스 기반 ECG 감지 IoT 응용 서비스에 관한 연구)

  • Mariappan, Vinayagam;Lee, Seungyoun;Lee, Junghoon;Lee, Juyoung;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.3
    • /
    • pp.18-23
    • /
    • 2016
  • Internet of things (IoT) is revolutionizing in the patient-Centered medical monitoring and management by authorizing the Smartphone application and data analysis with medical centers. The network connectivity is basic requirement to collect the observed human beings' health information from Smartphone to monitor the health from IoT medical devices in personal healthcare. The IoT environment built in Smartphone is very effective and does not demand infrastructure. This paper presents the smart phone deployed personal IoT architecture for Non-Invasive ECG Capturing. The adaptable IoT medical device cum Gateway is used for personal healthcare with big data storage on cloud configuration. In this approach, the Smartphone camera based imaging technique used to extract the personal ECG waveform and forward it to the cloud based big data storage connectivity using IoT architecture. Elaborated algorithm allows for efficient ECG registration directly from face image captured from Smartphone or Tablet camera. The profound technique may have an exceptional value in monitoring personal healthcare after adequate enhancements are introduced.

Comparative Study on the Facilities for the Elderle Care (노인케어시설의 정책개발을 위한 국제비교연구)

  • 김기훈
    • Health Policy and Management
    • /
    • v.8 no.1
    • /
    • pp.203-230
    • /
    • 1998
  • This purposes of this study is to develope policies on the facilities for the elderly care in Korea. Methodology of this study adopts comparative analysis on the facilities for the elderly care in 6 countries which have experienced various problems on the elderly. These 6 countries are Japan, Sweden, America, Australian, England and Germany. Major issues for comparative analysis are the standard of care facilities, residence condition, finance of facilities establishment and expense, operating system, management, and the law and administrative structure about the facilities for the elderly care. The elderly people need various kinds of welfare services such as medical care facilities, nursing home facilities, home care facilities etc.. Thus the public policies for the aging population nations are compose of income maintenance program, health and medical care services and social welfare services. The policies of facilities for elderly care are very important since these policies include the characteristics of income maintenance, me\ulcorner미 care program and welfare program. This study willsupply basic data for the development of facilities for the elderly care in Korea, especially conceming the system and institutional device of the facilities.

  • PDF

Medicare's Reimbursement for Innovative Technologies: Focusing on Artificial Intelligence Medical Devices (미국의 혁신의료기술 지불보상제도: 인공지능 의료기기를 중심으로)

  • Lee, Boram;Yim, Jaejun;Yang, Jangmi
    • Health Policy and Management
    • /
    • v.32 no.2
    • /
    • pp.125-136
    • /
    • 2022
  • The costliness index (CI) is an index that is used in various ways to improve the quality of medical care and the management of appropriate treatment in medical institutions. However, the current calculation method for CI has a limitation in reflecting the actual medical cost of the patient unit because the outpatient and inpatient costs are evaluated separately. It is desirable to calculate the CI by integrating the medical cost into the episode unit. We developed an episode-based CI method using the episode classification system of the Centers for Medicare and Medicaid Services to the National Inpatient Sample data in Korea, which can integrate the admission and ambulatory care cost to episode unit. Additionally, we compared our new method with the previous method. In some episodes, the correlation between previous and episode-based CI was low, and the proportion of outpatient treatment costs in total cost and readmission rates are high. As a result of regression analysis, it is possible that the level of total medical costs of the patient unit in low volume medical institute and rural area has been underestimated. High proportion of outpatient treatment cost in total medical cost means that some medical institutions may have provided medical services in the ambulatory care that are ancillary to inpatient treatment. In addition, a high readmission rate indicates insufficient treatment service for inpatients, which means that previous CI may not accurately reflect actual patient-based treatment costs. Therefore, an integrated patient-unit classification system which can be used as a more effective CI indicator is needed.

Design of Interworking Technology for Heterogeneous Medical Device Networks in Smart Healthcare Environments (스마트 의료 환경에서 이기종 네트워크 간 연동 기술 설계)

  • Kim, Minjin;Lee, Seunghan;Kim, Jaesoo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.4
    • /
    • pp.25-31
    • /
    • 2015
  • Smart healthcare environments which merge medical and IT technology are getting ready for the third generation centering EHR from current second generation. As a basic technology for the introduction and activation of EHR systems it requires heterogeneous network interworking techniques between various wired and wireless medical devices. Interworking technology for heterogeneous network among various medical devices is needed to introduce EHR system. The heterogeneous network interworking technology is needed for construction of a reliable data system to convert each of unstructured data into structured data. Therefore, in this paper, we identify the domestic and international trends of smart medical field and analyze the characteristics of wired and wireless communication technology that is used in a heterogeneous network. and also suggest requirements needed for interworking technology and provide interworking technology based on them. we expect that proposed method which is designed for smart healthcare environments would provide a basic architecture needed for third smart medical technology generation.

The Development of Safety and Essential Performance Criteria for Lower Extremity Robotic Assisted Gait Training System (하지 로봇재활의료기기의 안전성 및 필수성능 평가 기준 개발)

  • Yong Wan Kang;Ji Yean Kwon
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.190-203
    • /
    • 2023
  • The purpose of this study is to provide basic data to ensure the safety and essential performance of a Lower Extremity robotic assisted gait training system and to provide advanced technology and technical basis to the industry handling the system. Based on IEC 60601-1:2012/AMD2:2020 (Medical Electrical Equipment - General requirements for basic safety and essential performance of medical electrical equipment), IEC 62366-1:2015/AMD1:2020 (Medical devices - Part 1: Application of usability engineering to medical devices) and EN ISO 14971:2019 (Medical devices - Application of risk management to medical devices), the requirements for ensuring the safety and essential performance of the Lower Extremity robotic assisted gait training system were derived. Through the Delphi survey method and scenario analysis, which reflects the opinions and knowledge of experts in the fields of development, testing and review of technical documents, and quality assurance of medical devices, validity and reliability were conducted and obtained results with adequate content validity ratio (CVR; 0.7≤) and excellent reliability (Cronbach's α; 0.9≤). As a result, it was confirmed that the reliability and validity of the risk management process to ensure the safety and essential performance of the Lower Extremity robotic assisted gait training system are required a model can be established to provide measures to reduce risks according to the level of risk exposure caused by usage.

Design and Implementation of Medical Information System using QR Code (QR 코드를 이용한 의료정보 시스템 설계 및 구현)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • The new medical device technologies for bio-signal information and medical information which developed in various forms have been increasing. Information gathering techniques and the increasing of the bio-signal information device are being used as the main information of the medical service in everyday life. Hence, there is increasing in utilization of the various bio-signals, but it has a problem that does not account for security reasons. Furthermore, the medical image information and bio-signal of the patient in medical field is generated by the individual device, that make the situation cannot be managed and integrated. In order to solve that problem, in this paper we integrated the QR code signal associated with the medial image information including the finding of the doctor and the bio-signal information. bio-signal. System implementation environment for medical imaging devices and bio-signal acquisition was configured through bio-signal measurement, smart device and PC. For the ROI extraction of bio-signal and the receiving of image information that transfer from the medical equipment or bio-signal measurement, .NET Framework was used to operate the QR server module on Window Server 2008 operating system. The main function of the QR server module is to parse the DICOM file generated from the medical imaging device and extract the identified ROI information to store and manage in the database. Additionally, EMR, patient health information such as OCS, extracted ROI information needed for basic information and emergency situation is managed by QR code. QR code and ROI management and the bio-signal information file also store and manage depending on the size of receiving the bio-singnal information case with a PID (patient identification) to be used by the bio-signal device. If the receiving of information is not less than the maximum size to be converted into a QR code, the QR code and the URL information can access the bio-signal information through the server. Likewise, .Net Framework is installed to provide the information in the form of the QR code, so the client can check and find the relevant information through PC and android-based smart device. Finally, the existing medical imaging information, bio-signal information and the health information of the patient are integrated over the result of executing the application service in order to provide a medical information service which is suitable in medical field.

Development of Motion Recognition and Real-time Positioning Technology for Radiotherapy Patients Using Depth Camera and YOLOAddSeg Algorithm (뎁스카메라와 YOLOAddSeg 알고리즘을 이용한 방사선치료환자 미세동작인식 및 실시간 위치보정기술 개발)

  • Ki Yong Park;Gyu Ha Ryu
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.125-138
    • /
    • 2023
  • The development of AI systems for radiation therapy is important to improve the accuracy, effectiveness, and safety of cancer treatment. The current system has the disadvantage of monitoring patients using CCTV, which can cause errors and mistakes in the treatment process, which can lead to misalignment of radiation. Developed the PMRP system, an AI automation system that uses depth cameras to measure patient's fine movements, segment patient's body into parts, align Z values of depth cameras with Z values, and transmit measured feedback to positioning devices in real time, monitoring errors and treatments. The need for such a system began because the CCTV visual monitoring system could not detect fine movements, Z-direction movements, and body part movements, hindering improvement of radiation therapy performance and increasing the risk of side effects in normal tissues. This study could provide the development of a field of radiotherapy that lags in many parts of the world, along with the economic and social importance of developing an independent platform for radiotherapy devices. This study verified its effectiveness and efficiency with data through phantom experiments, and future studies aim to help improve treatment performance by improving the posture correction mechanism and correcting left and right up and down movements in real time.

Setting Priority Criteria for Classification of Self-Testing In Vitro Diagnostic Medical Devices Using Analytic Hierarchy Process Technique (Analytic Hierarchy Process 기법을 활용한 개인용 체외진단의료기기 분류기준에 대한 우선순위 연구)

  • Seol-Ihn Kim;Do-Yun Pyeon;Yong-Ik Jeong;Jahyun Cho;Gaya Noh;Green Bae;Hye-Young Kwon
    • Health Policy and Management
    • /
    • v.33 no.2
    • /
    • pp.173-184
    • /
    • 2023
  • Background: The coronavirus disease 2019 pandemic has been challenging the healthcare service, i.e., the vitalization of the point of care accompanying self-testing in vitro diagnostic medical devices (IVDs). This study aims to suggest priority criteria to classify self-testing IVDs using the analytic hierarchy process technique. Methods: Two dimensions of the characteristics embedded in the IVDs and the diseases to be diagnosed with self-testing IVDs were parallelly considered and independently investigated. In addition, three expert panels consisting of laboratory medical doctors (n=11), clinicians (n=10), and citizens (n=11) who have an interest in the selection of self-testing IVDs were asked to answer to questionnaires. Priorities were derived and compared among each expert panel. Results: First of all, ease of specimen collection (0.241), urgency of the situation (0.224), and simplicity of device operation (0.214) were found to be the most important criteria in light of the functional characteristics of self-testing IVDs. Medical doctors valued the ease of specimen collection, but the citizen's panel valued self-management of the disease more. Second, considering the characteristics of the diseases, the priority criteria were shown in the order of prevalence of diseases (0.421), fatality of disease (0.378), and disease with stigma (0.201). Third, medical doctors responded that self-testing IVDs were more than twice as suitable for non-communicable diseases as compared to communicable diseases (0.688 vs. 0.312), but the citizen's group responded that self-testing IVDs were slightly more suitable for infectious diseases (0.511 vs. 0.489). Conclusion: Our findings suggested that self-testing IVDs could be primarily classified as the items for diagnosis of non-communicable diseases for the purpose of self-management with easy specimen collection and simple operation of devices, taking into account the urgency of the situation as well as prevalence and fatality of the disease.