• Title/Summary/Keyword: Medical Device Design

Search Result 262, Processing Time 0.026 seconds

Design and Implementation of a Cardiac Arrest Supporting System Using Wearable Device (웨어러블 기기를 사용한 심정지 환자 지원 시스템의 설계 및 구현)

  • Jang, Jin-Soo;Lee, Seo-Joon;Lee, Kwang-In;Lee, Tae-Ro
    • Journal of Digital Convergence
    • /
    • v.15 no.1
    • /
    • pp.227-238
    • /
    • 2017
  • Cardiac arrest is a serious intensive emergency disease that causes death within less than several minutes by depriving the body and brain of blood supply. Survival rate of cardiac arrest patients outside of hospitals is especially low. This is because pedestrians usually do not perceive the patient as a sick person, also, even if they do so, they have no medical knowledge to properly react to such emergency. The purpose of this study is to propose a solution that uses widely spread smart phones to alert pedestrians of the cardiac arrest patient, prevents cardiac arrest, and provides first-aid measures. By applying the proposed solution, cardiac arrest can be prevented in advance, pedestrians can be alerted to keep the golden time(4 minutes), and first witness can quickly proceed with CPR, ultimately enhancing the survival rate of the cardiac arrest patient.

Design and Implementation of IEEE 11073/HL7 Translation Gateway Based on U-Healthcare Application Service for M2M (M2M을 위한 U-헬스케어 응용 서비스 기반 IEEE 11073/HL7 변환 게이트웨이 설계 및 구현)

  • Chun, Seung-Man;Nah, Jae-Wook;Park, Jong-Tae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.3B
    • /
    • pp.275-286
    • /
    • 2011
  • As the 21st century paradigm of healthcare service changes from post-therapeutic treatment to disease prevention and management in advance, the M2M-based u-healthcare application service is increasingly important. M2M-based u-healthcare application service uses mobile handsets equipped with sensors to measure vital information, and the medical staff in remote locations can manage the health of the patient or the public in real time. In this paper, IEEE/HL7 translation gateway, utilizing the gateway based on M2M u-healthcare application service structure, which is based on international standards, has been designed and implemented. Specifically, the gateway between ISO/IEEE 11073 standards and ANSI HL7 has been developed. The former defines the protocol for the exchange of information between the agent device and the manger devices for measuring and handling biological signal, and the latter defines the application layer protocol for the exchange of various healthcare information systems. Finally, in order to demonstrate the functionality of the proposed architecture, the M2M-based U-healthcare application service based on IEEE/HL7 translation gateway, utilizing the gateway, has been developed which can measure, collect and process a variety of vital signs such as ECG or SpO2.

CPLD-based Controller for Bi-directional Communication in a Capsule Endoscope (캡슐형 무선 내시경의 양방향 통신을 위한 CPLD 기반의 제어기 설계 및 구현)

  • Lee Jyung Hyun;Moon Yeon Kwan;Park Hee Joon;Won Chul Ho;Lee Seung Ha;Choi Hyun Chul;Cho Jin Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.447-453
    • /
    • 2004
  • In the case of a capsule that can acquire and transmit images from the intestines, the size of the module and the battery capacity in the capsule are subject to restriction. The capsule must be swallowable and the battery must maintain the stable power during the capsule travels in the gastrointestinal tract. Therefore, it is important to control the endoscope using bi-directional wireless communication. In this study, encoder and decoder CPLD modules for bi-directional capsule endoscopes were designed and implemented. The designed controller for capsule endoscope can transmit the images of GI-track from inside to outside of the body and the capsules can be controlled by external controller simultaneously. The designed and implemented controller was verified by an in-vivo animal experiments. From these experiments, it was verified that the CPLD module for bi-directional capsule endoscope satisfied the design specifications.

Convergence study of mechanical properties and biocompatability of Ti Gr4 surface coated with HA using plasma spray for ossoeintegration (골융합 촉진을 위한 Ti Gr4의 HA 코팅에 대한 물리적 특성과 생체안정성에 대한 융합적 연구)

  • Hwang, Gab-Woon
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.145-151
    • /
    • 2021
  • This study aimed to investigate the efficient conduct of HA coating on Ti Gr4 for the practical use of medical device. Ti Gr4 alloy specimens measuring 𝜱 25mm × 1mm were sprayed with hydroxyapatite using thermal spray according to ASTM F1185-88. The surface was evaluated at #120, #400, #1,000 sandpaper and barrel finishing. Each coating properties was analyzed using SEM, UTS 20,000psi cap. and in vitro cytotoxicity. Surface morphology consists of well molten particles with very little resolidified or unmolten areas. The average Ca/P ratio is 1.74 which is in good agreement with theoretical value of 1.67. The average roughness Ra is very representative of roughness of specimen. The coatings are dense and well adhered to the substrate. The average bond strength was 61.74 MPa with a standard deviation of 4.06 which indicates fairly reliable results for ASTM 633 type tests. Variations in results from jig design, epoxy used, crosshead speeds etc. in vitro cytotoxicity result had a Grade 3. The results of the study are expected to be helpful in osseointegration and plasma-spray HA coated Ti Gr4 are more satisfactory in HA coating thickness elevation which is preferable to any other system.

Preliminary Study on Usual Cold or Heat as a Risk Factor for Hypertension in an University Faculty (일개 대학 교직원 집단에서 고혈압의 위험요인으로서의 평소 한열 예비 연구)

  • Jung, Kyung Sik;Kim, Yun Young;Baek, Young Hwa;Jang, Eunsu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.33 no.4
    • /
    • pp.226-232
    • /
    • 2019
  • This study was aimed to reveal that the usual cold or heat state was associated with hypertension and could be a risk. We emailed educational personnel in D university to join this study and 182 subjects participated in from March to December in 2016. The usual cold or heat diagnosis was conducted by two experts who had over 10 years expertise. The blood pressure was measured from the subjected after 10 minute rest with Jawon medical device. The hypertension was diagnosed by the guide of the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. The frequency analysis was used in general characteristics, Pearson's Correlation Coefficient analysis was conducted in among continuous variables, and chi-square test was also used between hypertension and cold or heat group. Logistic regression was analyzed to generate the odds ratios (ORs) and 95% confidence interval (CI) for hypertension. The cold score was suggested to have negative association with Body mass Index (BMI, -.374, p<.001), systolic blood pressure (-.333, p<.001), and diastolic pressure (-.261, p<.001). The heat score was analyzed to have positive association with Body mass Index (.413, p<.001), systolic blood pressure (.249, p<.001), and diastolic pressure (.156, p<.001). The distribution of the cold group (35.1%) and non-cold group (64.9%) in hypertension was significantly different (p=0.18). The distribution of the heat group (62.2%) and non-heat group (37.8%) was significantly different (p=0.27). The usual cold was associated with decreased ORs (ORs 0.405, 95% CI=0.191-0.857), and usual heat was associated with increased ORs (ORs 2.327, 95% CI=1.108-4.888). However, after adjusting body mass index, sex, and smoking, the association was not significantly different. It is possible that usual cold or heat associate with hypertension. Further study is needed to show that usual heat may be a independent risk factor for hypertension through follow up design.

The 33-mode Dielectric and Piezoelectric Properties of PIN-PMN-PT Single Crystal under Stress and Electric Field (압축하중 및 전계 인가에 따른 PIN-PMN-PT 단결정의 33-모드 유전 및 압전특성)

  • Lim, Jae Gwang;Park, Jae Hwan;Lee, Jeongho;Lee, Sang Goo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.91-96
    • /
    • 2020
  • The 33-mode dielectric and piezoelectric properties of Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 piezoelectric single crystals were measured under large electric field and compressive stress. The phase transition from the low temperature rhombohedral to the high temperature tetragonal structure was observed in the range of 110~140℃, and the Curie temperature changing to the cubic structure was about 165℃. The polarization change according to the compressive stress and electric field was measured. Relative dielectric constant was calculated from the slope of the polarization curve applied to the electric field, and the calculated relative dielectric constant increased as the applied stress increased, and the relative dielectric constant decreased as the applied electric field increased. The strain according to the compressive stress and electric field change was measured, the piezoelectric constant was calculated from the slope of the curve, and the phase transition according to the application of pressure was confirmed. In the case of practical application as an underwater or medical ultrasonic actuator, it is necessary to properly design the magnitude of the compressive stress applied to the device and the DC bias in order to maintain linear driving.

A Study on the Analysis of Virus Barrier Materials in a Chest X-ray Laboratory to Respiratory and Droplet Infections Only Patients (호흡기 및 비말감염 환자 전용 흉부 X-선 검사실의 바이러스 차단제 분석에 관한 연구)

  • Kim, Hyeon-Ju;Lee, Jun-Ho;Choi, Kwan-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.169-175
    • /
    • 2022
  • In this study, envisioned a laboratory equipped with virus blocking equipment for chest X-ray examinations of respiratory or droplet-transmitted virus-infected patients, and the material with the least deterioration in X-ray output and image quality among the proven blocking materials that block viruses in the design process. and experimented to find the thickness. As a result, when 1 cm of acrylic was applied, the X-ray output was reduced by only about 3.27 % compared to the absence of the barrier material, the SNR was 40.7 and CNR was 30.9, which was the best. The SSIM index result was analyzed as 0.891, which was analyzed to be implemented as the most similar image compared to the original image. The barrier material applied in the research method was objective in that it used a product approved by the Ministry of Food and Drug Safety. the results of this study are expected to provide useful information when installing X-ray examination facilities for the diagnosis and treatment of respiratory-related virus-infected patients in the future.

A Study of Health Condion and Shift Service of the Nurse in (종합병원 간호사의 교대근무와 건강상태에 관한 연구)

  • Kim, Soon-Ok
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.1
    • /
    • pp.119-133
    • /
    • 1997
  • Continuing shift service of clinical nurses can be not only the cause of occupational dissatisfaction by being connected with the change of circadian rhythm and the burden of duties to be applicable to such changes. But also of inviting the lowering of nursing quality by being affected to the resignation of the nurses as the threat to the health of the nurses. This study has selected 500 nurses at random under non-probability sampling who have been serving by shift in 7 general hospitals which have over 400 sickbeds for the purpose of cross-sectional survey design from Sep. 7 through 20, 1996. Standardized modification of the CMI has been used which was designed for Koreans with Cornell Medical Index developed by Broadman and his fellow workers as the study device. The structure of the device was composed of 35 questions on physical appeal(Chronbach's ${\alpha}=8507$) and 22 questions of mental appeal(Cronbach's ${\alpha}=.8166$ totalling 57 questions. The collected data has been computerrized by using SPSS. General character, present symptom, perceived symptom and others are sought by practical number and percentage, and the health condition comparison followed by general characters was conducted by t-test and ANOVA. The post test was by Duncan's test by the level of p<.05. 1) The items of the answer that they have the physical symptom presently by 50% or over of the nurses were as "Do you often have spells of severe dizziness", "Are your eyes often red or inflamed", "Does press or pain in the head often make like miserable", "Are your ankles often badly swollen", "Do pains in the back make it hard for you to keep up with your work". 2) The items of the answer by over 50% of the nurses as the mental symptom at present were "do you fell bad when criticized?", "Do you get angry when everything is against your will?", "do you get angry when ordered to do this and that?", "do you feel uneasy by such a trifle thing?", "do you tremble or are you freightened by sudden sound?". The mental and physical symptoms which have appeared presently in connection with the shift service have been agreed with each other. But the physical condition has been worse than the mental one. 3) In the physical health conditions followed by demosociological character, there were the significant differences by sex, religion and place of residence(p<.05), and in the mental health conditions, there were the significant differences by age, marital status, residence place and the required time for attending hospital(p<.05). 4) There was significant difference by the degree of satisfaction about the duty in both the physical and mental health conditions. In short, the higher the degree of duty satisfaction, the better the health conditions. 5) There were the significant difference according to the times of night duty and whether they take the drug or not or the kinds of the drugs in the physical health conditions related with the characters of night shift. Mental health conditions in the night shift case showed significant differences according to their taking drug or not or the kinds of the drugs(p<.05). I can confirm that the nurses have been affected continuously by the shift service mentally and physically. The maintenance of the physical and mental health of the nurses and its promotion are very important problem to guarantee the quality nursing in the performance of the nursing service continuously and effectively, so the hospital should make every effort to improve the duty conditions by finding out the causes affecting to their health. In the nursing management viewpoint, I think that elevating the satisfaction degree about the duty would be a great help to the promotion of physical and mental health conditions. But what is most important is that the nurses themselves should take care of themselves in maintaining the good conditions in their service in the hospital.

  • PDF

A Study on the Culture of Incense in the Period of T'ang (당대 향문화 연구)

  • Chun Hea-Sook;Lee Ae-Ryun
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.7 no.3
    • /
    • pp.113-127
    • /
    • 2005
  • From the ancient times, incense was used for various usages including a means of beauty expression with flavor, a medicine for disease treatment and a device for religious event or ritual. The period of T'ang was the times when cultural and material exchanges with foreign countries were very actively made under the political openness of the Chinese nation. Here the exchanges were made mainly through inland trade, called Silk Road(絲綢之路) and marine trade routes, Incense Road(香料之路). This indicates that incense was one of the main items actively traded at that time. In addition, literatures of the T'ang period show that in the Chinese nation, a wide range of classes from the imperial family to the public used incense for many different purposes. This suggests that the culture of incense was deeply prevailed and very socially significant in T'ang. This study investigated social factors that promoted the incense culture of T'ang and the applications and types of incense widely used in the period of T'ang. First, influential religions and the openness of sex culture were main social factors that made incense culture flourish in the period of T'ang. Above all, two main religions of the Chinese nation, Buddhism and Taoism became secularized under political protection by the imperial family. As Buddhism was popularized, the Buddhist ritual of incense burning made a contribution to making public incense culture. Providing its doctrines of eternal youth and eternal life, Taoism necessarily used incense to form a Taoistic climate. The flourishment of the foresaid religion in T'ang added more fuel to that of incense culture in the Chinese nation. The openness of sex culture brought about the Inauguration of the empress, improvement in female position and free relationships between man and woman. It was accelerated by sexology as a method of eternal youth provided by Taoism. The opened culture also developed the culture of kibang where female entertainers called kinyeo consumed lots of incense for decoration and sexual desire stimulation. These open climates of T'ang society made a great contribution to making incense culture, especially for decoration, prevailed throughout the Chinese nation. Second, types of incense prevailed and widely used in the period of T'ang included olive incense, germander(廣藿香), olibnum(乳香), myrrh Resinoid(沒藥), jia Xiang(甲香), clove(丁香) and Shen xian(沈香), all of which were imported from foreign nations and had various applications. Specifically, olive incense, germander(廣藿香), olibnum(乳香) and myrrh Resinoid(沒藥) were used for religious purposes while, jia Xiang(甲香), clove(丁香) and Shen xian(沈香) for the purposes of religion and decoration. In conclusion, a number of social factors including political, religious and medical purposes and the openness of sex culture set fundamentals on which the culture of incense was extensively developed and established as a social trend in T'ang. In the Chinese nation, incense culture was not just an option for taste, but a part of life style social members needed to know. People of T'ang not only enjoyed incense mainly for purposes of religion, pleasure and make-up, but also had the wisdom to know various effects of incense, curiosity about such new things and the will to imitate and pursue alien culture, resultantly flourishing incense culture. Thus the culture of incense represented many social aspects of T'ang.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF