• Title/Summary/Keyword: Medical Device Design

Search Result 262, Processing Time 0.03 seconds

Deburring Characteristics of Frame Hole in Fishing Trackle Reel (휘싱 트래클 릴 프레임홀 면의 디버링특성)

  • 김정두
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.203-208
    • /
    • 1998
  • Materials of the Frame hole in fishing trackle reel is made up a number large and small holes. Thus, it is difficult to effective machining. Abrasive flow machining(AFM) is useful to polish a internal or external surface of the 3-dimensional shape parts, which are used in many fields such as aerospace, automative, semi-conductor, and medical component industries. The machining process is that two hydraulic cylinders, which are located face to face, enforce abrasive media to the passage between workpiece and tooling parts alternately, and then the abrasives include in the media pass the passage and polish the surface of workpiece. The media which is made of polymer and abrasives plays the role of the tool for deburring or polishing complex shap workpiece by its viscoelastic characteristics. In this study, the abrasive media for abrasive flow machining was made by mixing viscielastic polymer with alunina and silicon carbide abrasive. Also, we present AFM device design and preliminary results of an investigation in to some aspects of the AFM process performance in fishing trackle reel.

  • PDF

Magnetic and Thermal Evaluation of a Magnetic Tunneling Junction Current Sensor Package

  • Rhod, Eduardo;Peter, Celso;Hasenkamp, Willyan;Grion, Agner
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.49-55
    • /
    • 2016
  • Nowadays there are magnetic sensors in a wide variety of equipment such as computers, cars, airplanes, medical and industrial instruments. In many of these applications the magnetic sensors offer safe and non-invasive means of detection and are more reliable than other technologies. The electric current in a conductor generates a magnetic field detected by this type of sensor. This work aims to define a package dedicated to an electrical current sensor using a MTJ (Magnetic Tunnel Junction) as a sensing device. Four different proposals of packaging, three variations of the chip on board (CoB) package type and one variation of the thin small outline package (TSOP) were analyzed by COMSOL modeling software by simulating a brad range of current injection. The results obtained from the thermal and magnetic analysis has proven to be very important for package improvements, specially for heat dissipation performance.

Design and Implementation of Medical Education Application System using Table-type Virtual Reality Device (테이블형 가상현실 장치를 이용한 의료교육용 응용 시스템의 설계 및 구현)

  • Choi, Yoo-Joo;Kim, Min-Jeong;Chung, Hae-Ra;Kim, Myoung-Hee
    • Annual Conference of KIPS
    • /
    • 2000.10a
    • /
    • pp.727-730
    • /
    • 2000
  • 본 논문에서는 보다 인간중심의 사용자 인터페이스를 제공하는 테이블형 가상현실 장치와 이에 적합한 직관적 상호작용 형태를 소개하고, 이러한 상호작용 기법을 이용한 의료교육용 응용시스템을 설계, 구현하였다. 본 교육 시스템은 테이블형 가상현실 장치를 사용함으로써 다수의 참여자에 대한 공동 교육을 용이하게 하고, 인터랙션 장치간 케이블 연결을 최소화한 비디오 기반 트랙킹을 통해 자유로운 사용자 인터랙션을 제공하였다. 또한, 해드 트랙킹을 기반으로 하여 주 관찰자의 시점으로 변화하는 동적, 입체 영상 가시화에 의한 증진된 몰입감을 제공함으로써, 교육의 효과를 높이도록 하였다.

  • PDF

Design of Vibrating Transducer for Implantable Middle Ear Hearing Aid (이식형 중이 청각보조기를 위한 진동 트랜스듀서의 설계)

  • 박형욱
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.535-544
    • /
    • 1996
  • In this paper, we analyzed the coil-magnet type vibrating transducer for the implantable middle ear hearing aid which is appropriate for patient's hearing level, and an experimental transducer system is designed For the objective and quantitative analysis of the transducer, a theoretical equivalent model containing coil, magneto and inner ear is developed To perform effective evaluation of the transducer, a transforming ratio Tr is introduced and its range that is suitable for practical implantable middle ear hearing device is foun4 The result of applying physical parameters of ear system to the proposed analytical model shows that frequency response of the coil magrlet type vibrator is predominantly governed by resistive impedance of the coil rather than inertia effect of the magnet and the inner parameters. In addition, we realized an experimental middle ear hearing aid system to show the theoretical validity of designed system and this will provide the basis of the development for actually implantable system.

  • PDF

A Measuring System for the Joint Rotations and the Myoelectric Signals of Human Arm Movements (팔운동의 관절 회전및 근전신호 측정 시스템)

  • Son, Jae-Hyun;Lee, Kwang-Suk;Hong, Sung-Woo;Ji, Seong-Hyon;Nam, Moon-Hyon
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.113-123
    • /
    • 1993
  • The aim of this study is to design a electrogoniometer for the measurement of three dimensional human elbow joint rotations. Using this device and visual monitor, we measured the angle of elbow joint rotations during the goal-directed movements. And we extracted myoelectric signals(MES) to verify the inter-relationship of elbow joint activities and constructed a system for the analysis of the spectrum for MES. The data obtained from this system will be used for the controller signal of prosthetic arm.

  • PDF

Continuum Mechanism with increased force and Optimal Design Method for Manually Controlled Endoscopic Surgical Instrument (수동 조작 내시경 수술 도구를 위한 힘이 증가된 연속체 메커니즘 및 이의 최적 형상 설계)

  • Lee, Hoyul;Jung, Euisung;Jeong, Yoosoo;Park, Young-Sang;Song, Chanho;Son, Jaebum
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.2
    • /
    • pp.164-171
    • /
    • 2021
  • This paper proposes a continuum mechanism for manually controlled endoscopic surgical instruments. The wire-driven mechanism is typically adapted for endoscopic surgical tools because motors cannot be embedded to the joints due to the size limitation. However, the conventional wire-driven mechanism has inherent problems caused by redundancy, such as deflection and low precision. It does not have operating force and manipulability for surgery. Therefore, a method to increase the force of the continuum mechanism using a multi-wire with simple mechanical structure is proposed. Moreover, for intuitive operation, a hand-controller mechanism that can manipulate the length of the wire without complex process is proposed. Finally, we show that the proposed mechanism and methods are applicable to endoscopic surgical tools through simple experiments.

Short Review on Quartz Crystal Microbalance Sensors for Physical, Chemical, and Biological Applications

  • Il Ryu, Jang;Hoe Joon, Kim
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.389-396
    • /
    • 2022
  • Quartz crystal microbalance (QCM) based sensors are used for various applications owing to advantages such as excellent accuracy and precision, rapid response, and tiny footprint. Traditional applications of QCM-based sensors include biological sensing and thin-film thickness monitoring. Recently, QCMs have been used as functional material for novel physical and chemical detections, and with improved device design. QCM-based sensors are garnering considerable attention in particulate matter sensing and electric nose application. This review covers the challenges and solutions in physical, chemical, and biological sensing applications. First, various physical sensing applications are introduced. Secondly, the toxic gas and chemical detection studies are outlined, focusing on introducing a coating method for uniform sensing film and sensing materials for a minimal damping effect. Lastly, the biological and medical sensing applications, which use the monomolecularly decorating method for biomolecule recognition and a brief description of the overall measuring system, are also discussed.

Study on Timing Failures in Cyber-Physical Systems

  • Kong, Joon-Ik
    • International journal of advanced smart convergence
    • /
    • v.11 no.3
    • /
    • pp.56-63
    • /
    • 2022
  • Cyber-physical systems (CPSs) can solve real problems by utilizing closely connected resources in the cyber world. Most problems arise because the physical world is uncertain and unpredictable. To address this uncertainty, information pouring from numerous devices must be collected in real-time, and each interconnected device must share the information. At this time, CPS must meet timing-related techniques and strict timing constraints that can deliver accurate information within predefined deadlines in order to interact closely beyond simply connecting the cyber and physical worlds. Timing errors in safety-critical systems, such as automobiles, aviation, and medical systems, can lead to catastrophic disasters. In this paper, we classify timing problems into two types: real-time delay and synchronization problems. The results of this study can be used in the entire process of CPS system design, implementation, operation, verification, and maintenance. As a result, it can contribute to securing the safety and reliability of CPS.

A Robot End-effector for Biopsy Procedure Automation with Spring-Triggered Biopsy Gun Mechanism (스프링 격발형 생검총 구조를 가진 생검 시술 자동화 로봇 말단장치)

  • Won, Jong-Seok;Moon, Youngjin;Park, Sang Hoon;Choi, Jaesoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.590-596
    • /
    • 2016
  • Biopsy is a typical needle type intervention procedure performed under radiographic image equipment such as computed tomography (CT) and cone-beam CT. This minimal invasive procedure is a simple and effective way for identifying cancerous condition of a suspicious tissue but radiation exposure for the patients and interventional radiologists is a critical problem. In order to overcome such trouble and improve accuracy in targeting of the needle, there have been various attempts using robot technology. Those devices and systems, however, are not for full procedure automation in biopsy without consideration for tissue sampling task. A robotic end-effector of a master-slave tele-operated needle type intervention robot system has been proposed to perform entire biopsy procedure by the authors. However, motorized sampling adopted in the device has different cutting speed from that of biopsy guns used in the conventional way. This paper presents the design of a novel robotic mechanism and protocol for the automation of biopsy procedure using spring-triggered biopsy gun mechanism. An experimental prototype has been successfully fabricated and shown its feasibility of the automated biopsy sequence.