• Title/Summary/Keyword: Media Exposure

Search Result 493, Processing Time 0.025 seconds

Effect of Exposure to Body Image in Media and Bullet Screen on Weight Loss Intention - Focused on Bilibili, a Video Sharing Website of China (미디어 노출 신체이미지와 탄막 이용이 다이어트 의도에 미치는 영향 -중국 비리비리(Bilibili) 동영상 사이트를 중심으로)

  • Liang, Shuang;Cho, Hee Jung;Lee, Hye Eun
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.10
    • /
    • pp.268-283
    • /
    • 2020
  • The purpose of this study was to examine the effect of exposure to body image in media and bullet screen on weight loss intention by specifically focusing on Bilibili, a video sharing website of China. For the study, a 3 (Social viewing: no bullet screen vs. complimentary bullet screen vs. critical bullet screen) x 2 (Body image in media: ideal vs. realistic) between-subjects factorial design was conducted. A total of 310 Chinese women in their 20s were recruited to participate in an experimental survey. The main results showed that viewing the ideal body image with the complimentary bullet screen and realistic body image with the critical bullet screen strengthened the participants' intention on weight loss. Finally, the interaction effect of social viewing and the types of bullet screen were examined. The higher weight-loss intention was revealed when social viewing was conducted with the complimentary bullet screen of the ideal image. The results of this study can enhance the understanding of the bullet screen as a type of social viewing and its effect on user behavior intention.

Fake News in Social Media: Bad Algorithms or Biased Users?

  • Zimmer, Franziska;Scheibe, Katrin;Stock, Mechtild;Stock, Wolfgang G.
    • Journal of Information Science Theory and Practice
    • /
    • v.7 no.2
    • /
    • pp.40-53
    • /
    • 2019
  • Although fake news has been present in human history at any time, nowadays, with social media, deceptive information has a stronger effect on society than before. This article answers two research questions, namely (1) Is the dissemination of fake news supported by machines through the automatic construction of filter bubbles, and (2) Are echo chambers of fake news manmade, and if yes, what are the information behavior patterns of those individuals reacting to fake news? We discuss the role of filter bubbles by analyzing social media's ranking and results' presentation algorithms. To understand the roles of individuals in the process of making and cultivating echo chambers, we empirically study the effects of fake news on the information behavior of the audience, while working with a case study, applying quantitative and qualitative content analysis of online comments and replies (on a blog and on Reddit). Indeed, we found hints on filter bubbles; however, they are fed by the users' information behavior and only amplify users' behavioral patterns. Reading fake news and eventually drafting a comment or a reply may be the result of users' selective exposure to information leading to a confirmation bias; i.e. users prefer news (including fake news) fitting their pre-existing opinions. However, it is not possible to explain all information behavior patterns following fake news with the theory of selective exposure, but with a variety of further individual cognitive structures, such as non-argumentative or off-topic behavior, denial, moral outrage, meta-comments, insults, satire, and creation of a new rumor.

Screen time, mealtime media use, and dietary behaviors in Korean preschoolers : a cross-sectional study

  • Young-Hee Han;Saerom Shin;Eun Yeol Woo;Hye-Kyung Park;Taisun Hyun
    • Korean Journal of Community Nutrition
    • /
    • v.28 no.3
    • /
    • pp.206-219
    • /
    • 2023
  • Objectives: Screen time refers to the time spent using screen media, such as televisions, smartphones, computers, or tablets. Excessive exposure to screen media has been reported to negatively impact young children's health and development, including overweight, short sleep duration, and language delays. This study examined the association of screen time and mealtime media use with dietary behaviors among preschool children. Methods: A cross-sectional survey was conducted on parents of children aged three to five years using the online questionnaires of the Nutrition Quotient for Preschoolers (NQ-P) and the Dietary Screening Test (DST). Data from 261 children's parents were analyzed. Results: Of the 261 children, 96.9% used screen media, 55.6% used screen media for two hours or more daily, and 30.7% were exposed to screen media during meals. The NQ-P scores were significantly lower in the children with longer screen time and mealtime media use. Children who used screen media for two hours or more and those exposed to screen media during meals consumed kimchi less frequently and confectionery and sugar-sweetened beverages more frequently than children who used less than two hours and were not exposed to screen media during meals. In addition, they were more likely to be picky about food, refuse to eat, and less likely to feed themselves than children with shorter screen time and no mealtime media use. Conclusions: This study reported an association between unhealthy dietary behaviors, feeding difficulties, and screen time and mealtime media use among preschool children. Further research should explore effective strategies for reducing children's screen time.

Estimation of Multi-Route Exposure and Aggregated Risk Assessment for Cadmium and Lead (카드뮴과 납의 다경로 노출량 추정 및 통합 위해성 평가)

  • Yu, Changwoo;Kwon, Hoonjeong
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.6
    • /
    • pp.587-601
    • /
    • 2020
  • Exposure to hazardous substances occurs through multiple pathways. Aggregated risk assessment, which includes all potential exposure pathways to a single toxicant, is necessary to prevent exposure to harmful substances. We aimed to estimate cadmium and lead exposure through various media, such as food, water, air, smoking, cosmetics, and female hygiene products. This study covered 10,733 subjects from the Seventh Korea National Health and Nutrition Examination Survey(2016, 2017). Dietary exposure was estimated using 24-hour recall data. For water and inhalational exposure, regional variations were considered. Water was classified as tap, bottled, and public water. Inhalational exposure was estimated using the '2014 Time Use Survey' based on daily lifestyle and social status. The frequency and volume of cosmetic usage were randomly approximated by sex and age. Post-menarcheal and premenopausal women were assumed to use feminine hygiene products. Non-carcinogenic aggregated risks were estimated using the Aggregate Risk Index from EPAs and the Total Exposure Hazard Index from Korean government guidelines. For carcinogenic risk assessment, excessive cancer risk was estimated. Ingestion, especially food, was the major route for both cadmium and lead exposure. Smoking was also associated with high cadmium exposure. Exposure to lead from cosmetics was remarkable but not critical. In aggregate risk assessments, median cadmium and lead exposure did not exceed the reference value. Sex, age, smoking status, and income affected exposure levels, unlike to regional variations.

The Development of Exposure Assessment Tools for Risk Assessment of Volatile Organic Compounds (VOCs의 위해성 평가를 위한 노출분석 방법 연구)

  • Jo, Seong-Joon;Shin, Dong-Chun;Chung, Yong;Lee, Duck-Hee;Breysse, Patrick N.
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.2
    • /
    • pp.147-160
    • /
    • 2002
  • Volatile organic compounds (VOCs) are an important public health issue in Korea and many important questions remain to be addressed with respect to assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in their analytic determination Valid Personal exposure assessment methods are needed to evaluate exposure frequency, duration and intensity, as well as their relationship to personal exposure characteristics. Biological monitoring is also important since it may contribute significantly in risk assessment by allowing the estimation of effective absorbed doses. This study was on ducted to establish the environmental measurement, personal dosimetry and biological monitoring methods for VOCs. These methods are needed to compare blood, urinary and exhalation breath VOC levels and to provide tools for risk assessment of VOC exposure. Passive monitors (badge type) and a active samplers (trap) for the VOCs collection were used for air sampling. Methods development included determining the minimum detectable amounts of VOCs in each media, as well as evaluating collection methods and developing analytical procedures. Method reliability was assessed by determining breakthrough volumes and comparing results between laboratories and with other methods. A total capacity of trap used in this study was 60ι. Although variable by compound, the average breakthrough was 20%. Also, there was no loss of compounds in trap even if keep for 45 day in -7$0^{\circ}C$. The recovery of active and passive methods was 69% ~ 126% and method detection limit was 0.24 $\mu\textrm{g}$/trap and 0.07 $\mu\textrm{g}$/badge. There was no statistical difference (P > 0.05) between active and passive methods.

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.

Development and Application of a Chemical Ranking and Scoring System for the Management of Endocrine Disrupting Chemicals (환경성 내분비계장애물질(EDCs)의 우선관리순위 결정법 개발 및 적용)

  • Lim, Miyoung;Park, Ji Young;Ji, Kyunghee;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.1
    • /
    • pp.76-89
    • /
    • 2018
  • Background: Exposure to endocrine disrupting chemicals (EDCs) has been considered one of the main causes of a range of endocrine diseases in modern society. An EDC priority list considering exposure, toxicity, and societal concern should be established for EDC management. Methods: The chemical ranking and scoring (CRS) system for EDCs was based on exposure, toxicity,and societal concern. The exposure score system was based on usage, circulation volume, bioaccumulation, and detection in consumer products. The toxicity score system was based on carcinogenicity and reproductive and developmental toxicity. The societal concern score system was based on domestic or international regulations and mass media reports. Results: A total of 165 EDCs were considered in the CRS system. The top-five priority EDCs were Bis(2-ethylhexyl) phthalate (DEHP), Benzene, Bisphenol A, Dibutyl phthalate (DBP) and Trichloroethylene. Phthalates, bisphenols and parabens were identified as priority chemical groups. Conclusion: We developed a CRS system for EDCs to identify priority EDCs for management. This will be a foundation to provide an EDC management plan based on scientific decision-making.

A Study on the Reduction of Patient's Exposure Dose according to the Arrival Time of Contrast Media in Abdominal CT Scan using Bolus Tracking Technique (Bolus tracking 기법을 이용한 복부 CT 검사 시 조영제 도달시간에 따른 환자 피폭선량 감소에 관한 연구)

  • Lee, Seung yong;Han, Dong kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • The purpose of this study is to find out the factors that affect the patient's exposure dose during the abdominal CT scan using the bolus tracking technique, and reducing the radiation exposure to the patient during the abdominal CT scan using the bolus tracking technique by adjusting the delay time according to the corresponding factor. The experiment was divided into two parts, and the first experiment was conducted with 300 patients There were 188 males and 112 females, and their average age was 58±12.18(19~85). In the second experiment, 150 subjects (100 males and 50 females) who were undergoing their follow-up examination among the first experiment subjects, and the difference in dose before and after was compared by applying the delay time according to the influencing factor. As a result of the first experiment, there was a relationship between the arrival time of the contrast media and the heart rate, and it was found that the arrival time decreased as the heart rate increased for both men and women. As a result of the second experiment, the average dose of CTDIvol and DLP before/after applying the delay time according to the heart rate decreased 4.98 mGy and 5.33 mGy·cm in the male group, and 3.54 mGy and 3.88 mGy·cm in the female group. By applying proper delay time according to the patient's heart rate during abdominal CT scan with the bolus tracking technique, the radiation exposure dose of the patient can be reduced.

A study on the relationship between selective exposure, opinion change, and political participation in a digital news distribution environment (개인과 미디어의 선택성이 강화된 디지털 뉴스 유통 환경에서 선택적 노출과 의견변화, 정치참여의 관계 연구)

  • Jihee Shin;Seungchan Yang
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.391-406
    • /
    • 2024
  • The current distribution of digital news has the potential to produce politically biased information for users as a result of individual choices and media selection based on those choices. Consequently, this research explored the factors affecting individual news selection and the effects of opinion changes and political participation that can occur when news tailored to users' partisan preferences is recommended. The phenomenon of selective exposure has been shown to be stronger when individuals utilize more limited information processing, experience higher discussion efficacy among groups with similar political beliefs. Furthermore, When a selective exposure group was randomly provided with a one-way message news that matched their partisan leanings, it was found that opinion consolidation, opinion-reinforcing information processing, and online political participation. On the other hand, when they were randomly presented with two-way messaging news in which the media balanced two competing partisan positions, they were found to be more likely to understand the other side's views and arguments, and more willing to adjust their existing opinions. We are confirmed that the balanced use of various opinions is very important in deliberative democratic process.

A Study on Characteristic of Photoelectric Absorption with Diagnostic X-ray Contrast Media (X-선 진단용 조영제의 광전흡수 특성에 관한 연구)

  • Kim, Young-Keun;Han, Jae-Jin;Lee, Kyung-Sup
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.46-51
    • /
    • 1998
  • The absorption coefficient of contrast media was measured in region of diagnostic radiology. Relative values of absorption coefficient was found the largest peak in the range of $60{\sim}70\;kVp$ for barium sulfate and 60 kVp for iodine. Increasing the thickness of contrast media and patient, the values of absorption coefficient was rising. In the Radiograph, desired $70{\sim}80\;kVp$ in the gastrointestinal digestion tract with barium sulfate and the vascular tract is before and behind 65 kVp of exposure.

  • PDF