• 제목/요약/키워드: Mechanical recovery performance

검색결과 255건 처리시간 0.026초

자동차용 배기열 회수 장치의 성능 특성에 관한 연구 (Study on the Performance Characteristics of Exhaust Heat Recovery Device in Automobile)

  • 홍영준;최두석;김종일
    • 한국자동차공학회논문집
    • /
    • 제20권2호
    • /
    • pp.78-84
    • /
    • 2012
  • The purpose of this study is to investigate the performance characteristics of new exhaust heat recovery device for the engine's fast warm-up. In this study, two different interior area designed for prototyping and on the exhaust heat recovery device to evaluate the performance compare the performance characteristics were chosen a better product. A company's product and selected prototype-2 were evaluated and compared the performance. This experiment was conducted under the same conditions. The time from starting to warm-up of engine was measured. As a result, the performance characteristics of the prototype-2 was not higher than that of the A company's product. However, in comparison with base system, prototype-2 of the exhaust heat recovery device discover that the warm-up time was shortened.

마이크로터빈의 열회수 성능시험 (Test of Heat Recovery Performance of a Microturbine)

  • 전무성;이종준;김동섭;장세동
    • 대한기계학회논문집B
    • /
    • 제32권8호
    • /
    • pp.629-635
    • /
    • 2008
  • Recently, microturbines have received attention as a small-scale distributed power generator. Since the exhaust gas carries all of the heat release, the microturbine CHP (combined heat and power) system is relatively compact and easy to maintain. Generating hot water or steam is usual method of heat recovery from the microturbine. In this work, a heat recovery unit producing hot water was installed at the exhaust side of a 30 kW class microturbine and its performance characteristics following microturbine power variation was investigated. Heat recovery performance has been compared for different operating conditions such as constant hot water temperature and constant water flow rate. In particular, the influence of water flow rate and hot water temperature on the recovered heat was analyzed.

해저침적 HNS 회수용 기계장치의 성능요건 기반 개념설계 (Conceptual Design of Mechanical System for Recovery of Seabed-Deposited Hazardous and Noxious Substances Based on Performance Requirements)

  • 황호진
    • 해양환경안전학회지
    • /
    • 제26권6호
    • /
    • pp.689-697
    • /
    • 2020
  • 위험유해물질(HNS, Hazardous and Noxious Substances)은 해상운송 과정에서 다양한 사고에 노출되어 있어 많은 양이 바다에 유출될 우려가 있다. HNS 유출에 따른 해양환경의 손상은 유류 유출에 의한 손상보다도 훨씬 큰 것으로 알려져 있다. 특히 해저로 침강하여 침적되는 HNS는 해저생태계에 돌이키기 어려운 피해를 주게 되므로, 반드시 회수되어야 한다. 해저로부터 HNS를 회수하기 위해서는 해저침적 HNS에 대한 정확한 탐지, 안정화 처리 및 회수를 위한 절차와 장비가 필요하다. 그 중에서도 기계적 회수장치를 개발하기 위해서는 성능지표를 이용하여 성능요건을 선정하고, 이를 토대로 기계적 회수장치에 대한 개념설계가 이루어져야 한다. 따라서 본 연구에서는 해저침적 HNS의 회수 절차에서 요구되는 기계적 회수장치에 대한 개념설계안을 제시하였다. 개념설계안으로 해저침적 HNS를 회수하기 위한 기본 시나리오를 제시하고, 자체적 밀폐 성능을 가지는 흡인 기초를 활용하는 방안을 채택하였다. 기계적 회수장치는 흡인 기초, 오염 방지, 펌프 시스템, 제어 시스템, 모니터링 장비, 위치정보 장비, 이송 장비, 탱크로 구성된다. 이러한 개념설계안은 기계적 회수장치의 부품 및 형상을 결정하는 기본설계에 반영되어 활용될 것으로 기대된다.

동시냉난방 히트펌프의 냉매 충전량과 운전모드 변화에 따른 성능특성에 관한 연구 (The Performance of a Simultaneous Heat and Cooling Heat Pump at Various Charging Conditions)

  • 송인식;최종민;주영주;정현준;강훈;김용찬
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.492-499
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

Maneuvering Target Tracking Using Error Monitoring

  • Fang, Tae-Hyun;Park, Jae-Weon;Hong, Keum-Shik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.329-334
    • /
    • 1998
  • This work is concerned with the problem of tracking a maneuvering target. In this paper, an error monitoring and recovery method of perception net is utilized to improve tracking performance for a highly maneuvering tar-get. Many researches have been performed in tracking a maneuvering target. The conventional Interacting Multiple Model (IMM) filter is well known as a suboptimal hybrid filter that has been shown to be one of the most cost-effective hybrid state estimation scheme. The subfilters of IMM can be considered as fusing its initial value with new measurements. This approach is also shown in this paper. Perception net based error monitoring and recovery technique, which is a kind of geometric data fusion, makes it possible to monitor errors and to calibrate possible biases involved in sensed data and extracted features. Both detecting a maneuvering target and compensating the estimated state can be achieved by employing the properly implemented error monitoring and recovery technique. The IMM filter which employing the error monitoring and recovery technique shows good tracking performance for a highly maneuvering target as well as it reduces maximum values of estimation errors when maneuvering starts and finishes. The effectiveness of the pro-posed method is validated through simulation by comparing it with the conventional IMM algorithm.

  • PDF

핀 형상에 따른 폐열회수용 핀-튜브 열교환기의 성능분석 (Performance Analysis of Fin-Tube Heat Exchangers with Various Fin Shapes for Waste Gas Heat Recovery)

  • 맹재훈;구병수;전용두;이금배
    • 설비공학논문집
    • /
    • 제23권9호
    • /
    • pp.627-632
    • /
    • 2011
  • As an innovative effort to secure economically viable heat recovery system, various fin shapes for industrial fin-tube heat exchangers have been studied for better performance. In this study, the waste gas heat recovery from four different fin shapes was experimentally performed for heat transfer rate and pressure drop. According to the tested results, the twist and wavy shape fins of rectangular type show the superior performance in terms of Goodness factor and jH/f factor ratio, whereas the circular spiral fin shows the inferior values. Experimental results shows good comparison with the numerical results with a slight discrepancy of 5%, which is quite resonable.

간접식 증발냉각장치의 성능예측과 에너지절약에 관한 연구 (Study on Performance Prediction and Energy Saving of Indirect Evaporative Cooling System)

  • 유성연;김태호;김명호
    • 대한기계학회논문집B
    • /
    • 제39권9호
    • /
    • pp.743-749
    • /
    • 2015
  • 본 연구의 목적은 간접식 증발냉각 장치의 성능을 예측하고, 장치를 공기조화기의 배기열 회수에 적용하였을 경우의 에너지 절약효과를 분석하는 것이다. 플라스틱 열교환기를 사용한 간접식 증발냉각장치의 성능 상관식을 여러가지 조건에서 얻어진 실험 데이터로부터 구하였으며, 이 상관식을 이용하여 환기와 외기의 조건을 변화시켜가면서 장치의 성능변화를 예측하였다. 또한 간접식 증발냉각장치의 배기열 회수에 의한 에너지 절약효과를 우리나라 몇개 도시의 표준기상데이터를 사용하여 분석하였다. 여름철 배기열 회수를 위한 현열냉각장치의 사용율은 평균 44.3%이며 증발냉각장치의 사용율은 96.7% 이다. 증발냉각장치의 배기열 회수에 의한 에너지 절약은 현열냉각장치에 비해서 훨씬 높으며, 서울의 경우 약 3.89 배로 나타났다.

증발냉각을 이용한 배기열 회수장치의 성능에 관한 연구 (Performance of Heat Recovery System using Evaporative Cooling)

  • 유성연;김태호;김명호
    • 대한기계학회논문집B
    • /
    • 제39권1호
    • /
    • pp.37-43
    • /
    • 2015
  • 현열 뿐만 아니라 잠열을 이용하는 증발냉각은 배기열 회수에 매우 유용하게 사용될 수 있다. 본 연구의 목적은 증발냉각을 이용한 배기열 회수장치의 성능을 실험적으로 규명하는 것이다. 성능실험장치는 플라스틱 열교환기, 물 분무 노즐, 공기유동용 홴, 물 순환용 펌프, 수조, 온도 습도 유량 측정 센서 등으로 구성되었다. 증발이 없는 현열 회수에서의 유용도와 증발을 수반하는 전열 회수에서의 유용도를 여러가지 작동조건에서 측정하여 비교하였다. 현열냉각과 증발냉각의 유용도는 공기의 유량이 증가함에 따라 감소하고, 대향류에서의 유용도가 평행류에서의 유용도 보다 휠씬 높다. 증발냉각의 경우 물 유량이 증가함에 따라 유용도는 증가하고, 평행류가 대향류보다 물 유량에 더 민감함을 알 수 있다.

Study on Performance Evaluation of Oscillating Heat Pipe Heat Exchanger for Low Temperature Waste Heat Recovery

  • Bui, Ngoc-Hung;Kim, Ju-Won;Jang, In-Seung;Kang, Jeong-Kil;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권2호
    • /
    • pp.73-81
    • /
    • 2003
  • The performance of heat exchanger using oscillating heat pipe (OHP) for low temperature waste heat recovery was evaluated. OHP used in this study was made from low finned copper tubes connected by many turns to become the closed loop of serpentine structure. The OHP heat exchanger was formed into shell and tube type. R-22 and R-141b were used as the working fluids of OHP with a fill ratio of 40 vol.%. Water was used as the working fluid of shell side. As the experimental parameters, the inlet temperature difference between heating and cooling water and the mass velocity of water were changed. The mass velocity of water was changed from 30 kg/$m^2$s to 92 kg/$m^2$s. The experimental results showed that the heat recovery rate linearly increased as the mass velocity and the inlet temperature difference of water increased. Finally, the performance of OHP heat exchanger was evaluated by $\varepsilon$-NTU method. It was found that the effectiveness would be 80% if NTU were about 1.5.

삼중압 열회수 증기발생기와 중기터빈 시스템의 열설계 해석 (Thermal Design Analysis of Triple-Pressure Heat Recovery Steam Generator and Steam Turbine Systems)

  • 김동섭;이봉렬;노승탁;신흥태;전용준
    • 대한기계학회논문집B
    • /
    • 제26권3호
    • /
    • pp.507-514
    • /
    • 2002
  • A computation routine, capable of performing thermal design analysis of the triple-pressure bottoming system (heat recovery steam generator and steam turbine) of combined cycle power plants, is developed. It is based on thermal analysis of the heat recovery steam generator and estimation of its size and steam turbine power. It can be applied to various parametric analyses including optimized design calculation. This paper presents analysis results for the effects on the design performance of heat exchanger arrangements at intermediate and high temperature parts as well as steam pressures. Also examined is the effect of steam sources for deaeration on design performance.