• Title/Summary/Keyword: Mechanical indicator

Search Result 165, Processing Time 0.023 seconds

A Study on the Configuration of BOP and Implementation of BMS Function for VRFB (VRFB를 위한 BOP 구성 및 BMS 기능구현에 관한 연구)

  • Choi, Jung-Sik;Oh, Seung-Yeol;Chung, Dong-Hwa;Park, Byung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.74-83
    • /
    • 2014
  • This paper proposes a study on the configuration of balancing of plant(BOP) and implementation of battery management system(BMS) functions for vanadium redox flow battery(VRFB) and propose a method consists of sensor and required design specifications BOP system configuration. And it proposes an method of the functions implementation and control algorithm of the BMS for flow battery. Functions of BMS include temperature control, the charge and discharge control, flow control, level control, state of charge(SOC) estimation and a battery protection through the sensor signal of BOP. Functions of BMS is implemented by the sensor signal, so it is recognized as a very important factor measurement accuracy of the data. Therefore, measuring a mechanical signal(flow rate, temperature, level) through the BOP test model, and the measuring an electrical signal(cell voltage, stack voltage and stack current) through the VRFB charge-discharge system and analyzes the precision of data in this paper. Also it shows a good charge-discharge test results by the SOC estimation algorithm of VRFB. Proposed BOP configuration and BMS functions implementation can be used as a reference indicator for VRFB system design.

Monitoring of Strength Gain in Concrete Using Smart PZT Transducers

  • Qureshi, Adeel Riaz;Shin, Sung-Woo;Yun, Chung-Bang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.6
    • /
    • pp.501-508
    • /
    • 2007
  • This paper presents the feasibility of using electromechanical impedance based active sensing technique for nondestructive strength gain monitoring of early-age concrete by employing piezoelectric lead-zirconate-titanate (PZT) patches on concrete surface. The strength development of early age concrete is actively monitored by performing a series of experiments on concrete specimens under moist curing condition. The electrical admittance signatures are acquired for five different curing ages and compared with each other. The resonant frequency shifts of PZT patches with increasing days is observed which is on account of additional stiffening due to strength gain of concrete during curing and level of stiffening being related to strength obtained from compression tests on companion cylinder specimens. The proposed approach is found to be suitable for monitoring the development of compressive strength in early-age concrete. It is also observed in this study that root mean square deviation (RMSD) in admittance signatures of the PZT patches can also be used as an indicator of concrete strength development.

Development of Experimental Device for Analysis of Hydraulic Oil Characteristics with Dielectric Constant Sensors (유전상수 센서를 이용한 유압 작동유의 분석을 위한 실험장비 개발)

  • Hong, Sung-Ho
    • Tribology and Lubricants
    • /
    • v.37 no.2
    • /
    • pp.41-47
    • /
    • 2021
  • An experimental device was developed for analysis of hydraulic oil characteristics with dielectric constant sensors. Online analysis is the most effective method of the three methods used for analyzing lubricant oils. This is because it can monitor the machine condition effectively using oil sensors in real time without requiring excellent analysis skill and eliminates human errors. Determining the oil quality usually requires complex laboratory equipment for measuring factors such as density, viscosity, base number, acid number, water content, additive, and wear debris. However, the electric constant is another indicator of oil quality that can be measured on-site. The electric constant is the ratio of the capacitance of a capacitor using that material as a dielectric, compared with a similar capacitor that has a vacuum as its dielectric. The electric constant affects the factors such as the base oil, additive, temperature, electric field frequency, water content, and contaminants. In this study, the tendency of the electric constant is investigated with a variation of temperature, water content, and dust weight. The experimental device can control working temperature and mix the contaminants with oil. A machine condition monitoring program developed to analyze hydraulic oil is described. This program provides graph and digital values with variation of time. Moreover, it includes an alarm system for when the oil condition is bad.

PZT Impedance-based Damage Detection for Civil Infrastructures (토목 구조물의 PZT Impedance 기반 손상추정기법)

  • S. H. Park;Y. Roh;C. B. Yun;J. H. Yi
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.373-380
    • /
    • 2004
  • This paper presents the feasibility of an impedance-based damage detection technique using piezoelectric (PZT) transducers for civil infrastructures such as steel bridges. The impedance-based damage detection method is based on monitoring the changes in the electrical impedance. Those changes in the electrical impedance are due to the electro-mechanical coupling property of the piezoelectric material and structure. An effective integrated structural health monitoring system must include a statistical process of damage detection that is automated and real time assessment of damage in the structure. Once measured, damage sensitive features from this impedance change can be statistically quantified for various damage cases. The results of the experimental study on three kinds of structural members show that cracks or loosened bolts/nuts near the PZT sensors may be effectively detected by monitoring the shifts of the resonant frequencies. The root mean square (RMS) deviations of impedance functions between before and after damages were also considered as a damage indicator. The subsequent statistical methods using the impedance signature of the PZT sensors were investigated.

  • PDF

Evaluation Indicators for Learning Company Participating Work-Study Parallel Program (일학습병행 학습기업 평가지표)

  • Dong-Wook Kim;Hwan Young Choi
    • Journal of Practical Engineering Education
    • /
    • v.15 no.1
    • /
    • pp.223-232
    • /
    • 2023
  • The Work-Study parallel program has been promoted as a key policy to resolve the mismatch between industrial sites and school education and realize a competency-centered society, and as of December 2022, 16,664 companies participated in the training. Learning companies play a very important role as education and training supply organizations that conduct field training. In this study, for the evaluation of learning companies participating in work-study program, the authors derive important factors that determine the quality of on-site education and training by analyzing the cognitive structure of experts in charge of the company and present evaluation indicators for learning enterprises. Therefore, it is intended to lay the foundation for promoting the quality of work-study parallel program.

Gravity Compensation Techniques for Enhancing Optical Performance in Satellite Multi-band Optical Sensor (위성용 다중대역광학센서의 광학 성능 향상을 위한 자중보상기법)

  • Do-hee Yoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.127-139
    • /
    • 2024
  • This paper discusses a gravity compensation technique designed to reduce wavefront error caused by gravity during the assembly and alignment of satellite multi-band optical sensor. For this study, the wavefront error caused by gravity was analyzed for the opto-mechanical structure of multi-band optical sensor. Wavefront error, an indicator of optical performance, was computed by using the displacements of optics calculated through structural analysis and optical sensitivity calculated through optical analysis. Since the calculated wavefront error caused by gravity exceeded the allocated budget, the gravity compensation technique was required. This compensation technique reduces wavefront error effectively by applying the compensation load to the appropriate position of the housing tube. This method successfully meets the wavefront error budget for all bands. In the future, a gravity compensation equipment applying this technique will be manufactured and used for assembly and alignment of multi-band optical sensor.

Analgesic effect of acupuncture applied to $SI_6$ in a rat model of neuropathic pain (흰쥐의 신경병증성(神經病症性) 통증(痛症) 모델에서 양로(養老) 자침(刺鍼)의 진통효과(鎭痛效果))

  • Koo, Sung-Tae;Yang, Yoon-Jung;Kim, San;Yoo, In-Sik;Lim, Kyu-Sang
    • Korean Journal of Acupuncture
    • /
    • v.21 no.3
    • /
    • pp.59-76
    • /
    • 2004
  • Objectives : The usage of acupuncture has gained popularity for certain chronic pain conditions. However, the efficacy of acupuncture in various diseases has not been fully established and the underlying mechanism is not clearly understood. In the present study, the effect of electroacupuncture (EA) applied to yangno$(SI_6)$ on the neuropathic pain was examined. Methods : A common source of persistent pain in human is a neuropathic pain. Neuropathic pain was induced by tight ligation of L5 spinal nerve. When rats developed pain behaviors, EA was applied for 30 min. under enflurane anesthesia with repeated train stimuli at the intensity of 10X of muscle twitch threshold. The foot withdraw latency of the hind limb was measured for an indicator of pain level after each manipulation. Results : EA increased the mechanical threshold of the foot in the rat model of neuropathic pain significantly for the duration of 1 hr. suggesting a partial alleviation of pain. EA applied to SI6 point produced a significant improvement of mechanical sensitivity of the foot lasting for at least 1 h. However, $ST_{36}$ point did not produce any significant increase of mechanical sensitivity. The improvement of mechanical threshold was interpreted as an analgesic effect. The analgesic effort was specific to the acupuncture point since the analgesic effect on the neuropathic pain model could not be mimicked by EA applied to a point, $ST_{36}$. In addition, this analgesic effect of EA is mediated by a adrenergic mechanism of descending control of spinal cord from the brain. Conclusions : The data suggest that EA produces a potent analgesic effect on the neuropathic pain model in the rat; and 2) that EA-induced analgesia is mediated by a adrenergic mechanism of descending control in a point specific manner.

  • PDF

Effects of Soil Hardness on the Root Distribution of Pinus rigida Mill. Planted in Association with Sodding Works on the Denuded Land (사방시공지(砂防施工地)에 있어서 리기다소나무의 수근(樹根)의 분포(分布)에 미치는 토양견밀도(土壤堅密度)의 영향(影響))

  • Cho, Hi Doo
    • Journal of Korean Society of Forest Science
    • /
    • v.56 no.1
    • /
    • pp.66-76
    • /
    • 1982
  • Soil harness represents such physical properties as porosity, amount of water, bulk density and soil texture. It is very important to know the mechanical properties of soil as well as the chemical in order to research the fundamental phenomena in the growth and the distribution of tree roots. The writer intended to grip soil hardness by soil layer and also to grasp the root distribution and the correlation between soil hardness and the root distribution of Pinus riguda Mill. planted on the denuded hillside with sooding works by soil layer on soil profile. The site investigated is situated at Peongchang-ri 13, Kocksung county, Chon-nam Province. The area is consisted of 3.63 ha having on elevation of 167.5-207.5 m. Soil texture is sandy loam and parant rock in granite. Average slope of the area is $17^{\circ}-30^{\circ}$. Soil moisture condition is dry. Main exposure of the area is NW or SW. The total number of plots investigated was 24 plots. It divided into two groups by direction each 12 plots in NW and SW and divided into three groups by the position of mountain plots in foot of mountain, in hillside, and in summit of mountain, respectively. Each sampling tree was selected as specimen by purposive sampling and soil profile was made at the downward distance of 50cm form the sampling tree at each plot. Soil hardness, soil layer surveying, root distribution of the tree and vegetation were measured and investigated at the each plot. The soil hardness measured by the Yamanaka Soil Hardness Tester in mm unit. the results are as follows: 1) Soil hardness increases gradually in conformity with the increment of soil depth. The average soil indicator hardness by soil layer are as follows: 14.6mm in I - soil layer (0-10cm in depth from soil surface), 16.2mm in II - soil layer (10-20cm), 17.2 in III - soil layer (20-30cm), 18.3mm in IV - soil layer(30-40cm), 19.8mm in V - soil layer (4.50mm). 2) The tree roots (less than 20mm in diameter) distribute more in the surface layer than in the subsoil layer and decrease gradually according to the increment of soil depth. The ratio of the root distribution can be illustrated by comparing with each of five soil layers from surface to subsoil layer as follows: I - soil layer; 31%, II - soil layer; 26%, III - soil layer; 18%, IV - soil layer; 12%, V - soil layer; 13%, 3) Soil hardness and tree root distribution (less than 20mm in diameter) of Pinus rigida Mill. correlate negatively each other; the more soil hardness increases, the most root distribution decreases. The correlation coefficients between soil hardness and distribution of tree roots by soil layer are as follows: I - soil layer; -0.3675 (at the 10% significance level), II - soil layer; -0.5299 (at the 1% significance level), III - soil layer; -0.5573 (at the 2% significance level), IV - soil layer; -0.6922 (at the 5% significance level), V - soil layer; -0.7325 (at the 2% significance level). 4) the most suitable range of soil hardness for the growth of Pinus rigida Mill is the range of 12-14.9mm in soil indicator hardness. In this range of soil indicator hardness, the root distribution of this tree amounts to 41.8% in spite of 33% in soil harness and under the 20.9mm of soil indicator hardness, the distribution amounts to 93.2% in spite of 82% in soil hardness. Judging from above facts, the roots of Pinus rigida can easily grow within the soil condition of 20.9mm in soil indicator hardness. 5) The soil layers are classified by their depths from the surface soil.

  • PDF

Achievements in the Creativity Education through Freshmen Engineering Design (대학 신입생 공학설계과목을 통한 창의성 교육의 성과)

  • Baek, Yoon-Su;Lee, Jun-Hwan;Kim, Eun-Tai;Oh, Kyong-Joo;Park, Chung-Seon;Chung, Ji-Bum
    • Journal of Engineering Education Research
    • /
    • v.9 no.2
    • /
    • pp.5-20
    • /
    • 2006
  • This study is a part of the research on measuring and developing the creativity of college students, especially of engineering college students. This study was done in the class of imaginative design engineering which was a creativity training program integrated with engineering majors, including idea generation skills, creative problem solving, patent applications, design, manufacturing and marketing. Participants in this program were 75 freshman strudetns in engineering college. The achievements in this program were measured by the figural form of TTCT(Torrance Tests of Creative Thinking), as well as MBTI(Myers-Briggs Type Indicator). The results are as follows. First, TTCT scores of the participants in imaginetive design engineering increased significantly. Second, type indicator scores of MBTI varied significantly, to the directions of extrovert, feeling, and perception. Therefore, according to the results of this study, we can conclude the imaginative design engineering class had significant positive effects on the creativity of the engineering students.

A literature review on expansion of dental hygienists' radiography operations (치과위생사의 방사선 촬영업무의 확대에 대한 문헌적 고찰)

  • Choi, Young-Suk;Kim, Jin-Kyoung;Jang, Jong-Hwa;Park, Yong-Duk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.111-124
    • /
    • 2009
  • This study analyzes through the review of literature and laws the exposure time, clinical frequency, and radiation exposure of intraoral and extraoral radiography as well as of panoramic radiography performed by dental hygienists in dental clinics, compares the dental radiology curriculums of radiological science and dental hygiene departments, and proposes the expansion of dental hygienists' radiography operations. The radiology curriculums were compared between the radiological science and dental hygiene departments of colleges. For new analysis by radiography for dental diagnosis, the exposure time, radiation absorbed dose, effective dose, and number of days of natural radiation were compared by the type of oral radiation films and radiographical techniques proposed by domestic and international studies. The exposure time of panoramic radiography is 15 seconds and it takes about two minutes for completion, whereas the exposure time of the standard radiography is 0.2~0.8 seconds and it takes 10 times longer for completion of the radiography of full mouth than the panoramic radiography. The standard radiography can cause distortions of radiation at severely curved parts of dental arch and palatopharyngeal reflex. However, panoramic radiography can be performed even for lock jaw patients, causes less inconvenience to patients and is much simpler than the standard radiography. The percentage of dental clinics where radiography is performed by dental hygienists was 92.0%, and the percentage of standard film radiography by dental hygienists was 98% whereas the percentage of panoramic radiography by dental hygienists was 92%. For the absorbed dose which is an indicator of radiation exposure, the When the effective dose which is an indicator of the danger of radiation exposure was converted to the number of days of natural radiation, it was 3.3 days for panoramic radiography, but 13.9 days for the full mouth standard radiography by bisecting angle technique which was 4.2 times longer than the panoramic radiography. There were two colleges that had a dental radiology course with two credits in the departments of radiological science. The credits for dental radiology courses in the department of dental hygiene ranged varied by college, ranging from 3 to 8; on average, the theory course was 2.2 credits and the practice course was 2.02 credits. To summarize the above results, the percentage of dental clinics where panoramic radiography is performed by dental hygienists under the guidance of dentists is high. Panoramic radiography has become an essential facility for dental clinics. It is faster than standard film radiography and less dangerous due to low radiation exposure. Panoramic radiography is a simple mechanical job that does not require training of oral radiography by radiotechnologist. Because panoramic radiography is one of major operations which must be performed at all times in dental clinics, it must be designated as intraoral technique rather than extraoral technique, or legalized for inclusion in the scope of operations of dental hygienists.

  • PDF